PERM-A-BARRIER VPS. Product Description. Product Data Sheets. Self-adhering vapor permeable air and water barrier membrane

Similar documents
Perm-A-Barrier VPS (Vapor Permeable Sheet)

PERM-A-BARRIER NPS Detail Membrane

Perm-A-Barrier NPS (Non Permeable Sheet)

BITUTHENE Deck System

PREPRUFE 300R LT & 160R LT

Pre-applied waterproofing membranes that bond integrally to poured concrete for use below slabs or behind basement walls on confined sites

BITUTHENE 3000 and BITUTHENE Low Temperature Below-Grade

PREPRUFE Plus Low Temperature Membranes

PROCOR Composite Waterproofing System

PRODUCT DATA SHEET. Product Description

TL-0012 Use on Oriented Strand Board (OSB) Roof Sheathing Technical Letter

PRODUCT DATA SHEET. Product Description

PREPRUFE 300R Plus & 160R Plus

900HA is a two component, hand-applied seamless liquid waterproofing that is typically foottrafficable

SECTION Self-adhered sheet membrane water resistive air barriers, vapor permeable

Air and Vapor Barrier 3015

BITUTHENE 4000 Membrane

GRACE ICE & WATER SHIELD

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

SECTION SELF-ADHERING SHEET FLASHING

GRACE ICE & WATER SHIELD HT

The membrane is available in 9 in. and 18 in. widths. See the Product Data chart for more information.

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013)

Tensile ASTM D1970 MD = 939 psi / CD = 1252 psi Self Sealability / water penetration resistance around nails. ASTM D1970 Section 7.

A. Section includes fluid applied, vapor permeable membrane air barriers.

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Unique dual-profile drainage composite engineered to replace traditional perimeter drain systems

SECTION FLASHING AND SEALING FRAMING WITH NON-CHEMICAL TERMITE BARRIERS

SECTION FLUID-APPLIED VAPOR PERMEABLE MEMBRANE AIR BARRIER SYSTEM ASSEMBLY (August 2013)

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

SuperiorFlash. masterwall.com PO Box 397 Fortson GA Tech:

WeatherSmart Air Barrier Installation Guide

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

PART 2 - AIR BARRIERS SELF-ADHESIVE

Sealing of construction joints, cold joints and working joints in concrete, where reinjection may be necessary.

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

SECTION TW-60 Self-Adhering Sheet Waterproofing Membrane

Guide Specification for the OSI QUAD Window and Door Flashing System

SRP-AirOutshield UV Issued:

SECTION 07530CP EPDM MEMBRANE ROOFING

UNIFIED FACILITIES GUIDE SPECIFICATION

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

BITUTHENE System 4000 Above- Grade

Product and System Specifications DuPont Flashing Systems

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

SECTION AIR / MOISTURE / VAPOR BARRIERS 1

RETROGUARD RG. Product Data Sheets. Product Description. Features & Benefits. Materials. Delivery & Storage. Replacement fireproofing

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

Henry Blueskin VP160 Air Barrier System Installation Manual

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

SECTION EXTERIOR INSULATION AND FINISH SYSTEMS

A. Source Limitations: Obtain each type of building insulation through one source.

SECTION FLUID-APPLIED WEATHER AND AIR BARRIER SYSTEM FOR VENTILATED CAVITY

Construction Standards PAGE

DIVISION 7 MARFLEX 5000 FLUID APPLIED AIR & VAPOR BARRIER - 3 PART SPEC 07262

SECTION FLUID APPLIED VAPOR PERMEABLE AIR BARRIER MEMBRANE

DUPONT TYVEK COMMERCIAL SOLUTIONS

Section Pre-Applied Sheet Membrane Waterproofing

SECTION SELF-ADHERING SHEET WATERPROOFING CCW-711

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

Eclipse Energy Guard. Product Information & Installation Manual General Installation Requirements

SAFETRACK MTI can be easily applied by hand or by pump. Please contact your GCP representative for details.

NOVAWRAP ASPIRE Q & A

RECOMMENDED DESIGN SPECIFICATION

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

Ultimate Waterproofing Protection For Below Ground Structures

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

Student Services & Classroom Addition

JOHNS MANVILLE CONTINUOUS INSULATION WALL SYSTEM MASTER SPECIFICATION June 2014 CSI FORMAT SECTION FOIL-FACED RIGID INSULATION

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

Note to Specifier: Use this product for coated glass-mat faced polyisocyanurate insulation boards such as Rboard.

DuPont Tyvek Air Barrier Installation Guidelines. Canadian Version. Version 2

PART 4 - SELF ADHERING WATERPROOFING

ITEM 458 WATERPROOFING FOR STRUCTURES

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

WEIGHT PER PIECE (LBS.)

Advantages. Bituthene Liquid Membrane termination. Hydroduct 220. Bituthene System 4000 Surface Conditioner. Bituthene 4000 Waterproofing Memebrane

VaproFlashing PRODUCT DATA SHEET

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

SECTION FLUID-APPLIED WATERPROOFING

BITUTHENE. Grace Above Grade Waterproofing. Description. Advantages

Jiffy Seal 140/60 Waterproofing System

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

PROCOR DECK SYSTEM 3R Fluid applied waterproofing for inverted roofs, elevated concrete decks and green roofs

application instructions

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

ARCHITECTS & SPECIFIERS : SHINGLES, TILES, & ROOF COVERINGS

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

Dow Corning Silicone Air Barrier System. A more. energy-efficient. shade. green

DuPont Tyvek Wall Underlay Install Guide

D. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for waterproofing.

INSTALLATION MANUAL. ZIP System R12 Sheathing. Contents. 07 ZIP System R12 Sheathing Window Installation 08 ZIP System R12 Sheathing Siding Guidelines

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

Transcription:

PERM-A-BARRIER VPS Self-adhering vapor permeable air and water barrier membrane Product Description GCP Applied Technologies ( GCP ) PERM-A-BARRIER VPS (Vapor Permeable Sheet) membrane is a vapor permeable air and water barrier membrane consisting of a proprietary breathable carrier film with a specially designed adhesive. PERM-A-BARRIER VPS membrane provides superior protection against the damaging effects of air and water ingress on building structures. It creates an effective barrier against air infiltration and exfiltration, which reduces associated energy loss and condensation problems. PERM-A-BARRIER VPS membrane is vapor permeable for use in wall assemblies requiring a breathable characteristic. As a vapor permeable membrane, it permits the diffusion of water vapor that may otherwise condense in the wall structure. PERM-A-BARRIER VPS membrane is impermeable to liquid water, which also allows it to act as a water drainage plain.

Typical Vapor Permeable Air Barrier Application Drawings are for illustration purposes only. Please refer to gcpat.com/construction for specific application details. Advantages Fire Resistant meets NFPA 285 as part of various wall assemblies Air tight protects against air passage and associated energy loss Vapor permeable breathable membrane helps minimize moisture from being trapped in the wall cavity by allowing walls the ability to dry Water resistant resists wind driven rain

Self-adhered self adhesion to primed surfaces eliminates the need for mechanical fasteners Controlled thickness factory made sheet ensures constant, non-variable site application Lightweight allows for easy handling and installation Flexible conforms and bonds tightly to inside and outside corners following exterior building profiles Strong adhesion forms a tenacious bond to prepared construction substrates such as plywood, oriented strand board (OSB), block, masonry and exterior gypsum boards Compatible with GCP PERM-A-BARRIER Flashing Systems System Components Membrane PERM-A-BARRIER VPS membrane for use on above-grade walls at installation temperatures above 40 F (5 C) Ancillary Products (The most current Product Data Sheets and relevant supply information can be found at gcpat.com) PERM-A-BARRIER Primer Plus Water-based vapor permeable primer used to facilitate tenacious adhesion of PERM-A-BARRIER VPS to the substrate. PERM-A-BARRIER Wall Flashing heavy duty, fully-adhered membrane for throughwall flashing detailing PERM-A-BARRIER Detail Membrane flexible, fully-adhered membrane for detail flashing areas BTUTHENE Liquid Membrane two-component, elastomeric liquid and sealant applied detailing compound used for details and terminations BITUTHENE Mastic rubberized asphalt-based mastic and sealant used for details and terminations Limitations of Use Approved uses only include those uses specifically detailed in this Product Data Sheet and other current Product Data Sheets that can be found at gcpat.com PERM-A-BARRIER VPS Membrane is not intended for any other use. Contact GCP Technical Services where any other use is anticipated or intended. PERM-A-BARRIER VPS Membrane must not be applied in areas where it will be permanently exposed to direct sunlight. PERM-A-BARRIER VPS Membrane must be covered within 150 days of installation. Refer to Technical Letter 19, Exposure Guidelines for Perm-A-Barrier Self-Adhered Membranes. Maximum In Service Temperature (as installed) is 160 F (71 C) Safety and Handling Information Users must read and understand the product label and Safety Data Sheet before use. All users should acquaint themselves with this information prior to working with the material. Carefully read detailed precaution statements on the product labels and SDS before use. SDS s can be obtained from our web site at gcpat.com or by contacting GCP toll free at 1-866-333-3SBM (3726). Storage All materials must be protected from rain and physical damage. Pallets of PERM-A-BARRIER VPS product must not be double stacked on the job site. Store off the ground and provide cover on top and all sides, allowing for adequate ventilation. Store membrane where temperatures will not exceed 90 F (32 C) for extended periods. All products must be stored in a dry area away from high heat, flames or sparks. Store only as much material at point of use as is required for each day s work. Installation Details and Technical Letters The most up to date detail drawings and technical letters are available at gcpat.com. For complete application instructions, please refer to the current GCP Applied Technologies Contractor Handbook and Literature on (www.gcpat.com). Documents in hardcopy as well as information found on websites other than www.gcpat.com may be out of date or in error. Before using this product it is important that information be confirmed by accessing www.gcpat.com and reviewing the most recent product information, including without limitation Product Data Sheets and Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations. Please review all materials prior to installation of PERM-A-BARRIER VPS Detail Membrane. For technical assistance with detailing and problem solving please call toll-free at (866) 333-3SBM (3726). Temperature Limitation

PERM-A-BARRIER VPS membrane may be applied only onto dry substrates and when air and surface temperatures are above 40 F (5 C) PERM-A- BARRIER Primer Plus product is required on all substrates to receive PERM-A-BARRIER VPS membrane For application above 20 F (-6 C) and below 40 F (5 C) contact your GCP representative. Maximum In Service Temperature 160 F (71 C) Surface Preparation Surface must be smooth, clean, dry to the touch and free of voids, spalled areas, loose aggregate, loose nails, sharp protrusions or other matter that might hinder the adhesion or regularity of the wall membrane installation. Clean loose dust or dirt from the surface to which the wall membrane is to be applied by wiping with a clean, dry cloth or brush. OSB and plywood must have moisture content below 12%. Application Apply PERM-A-BARRIER Primer Plus product by air spray, brush or roller application. Allow the product to dry until surface becomes tacky. Drying times may vary depending on temperature and humidity conditions. Refer to PERM-A-BARRIER Primer Plus Product Data Sheet for installation recommendations. Also review technical letters on the GCP website for substrate preparation and application of PERM-A-BARRIER membranes to glass-mat faced gypsum sheathing and for the specific priming requirements on all glass-mat faced sheathing products. Membrane Application Cut membrane into easily handled lengths. For surfaces without pre-existing in place penetrations (masonry anchors, ties etc.) apply membrane horizontally or vertically to properly primed wall substrate, beginning at the base. All subsequent side and end laps must maintain a minimum overlap of 2 in. (51 mm). All horizontal laps must be applied in a shingle/water shedding configuration. For conditions with existing masonry anchors (ties), apply PERM-A-BARRIER VPS membrane horizontally to primed wall, beginning at the base. Each length of the membrane must be installed so that the upper edge runs continuously along the underside of the line of masonry anchors (ties). Subsequent membrane applied above must overlap the sheet below by 2 in. (51 mm) immediately below the line of anchors (ties). The membrane may be cut to an appropriate width such that it fits between the rows of anchors and allows for a min. 2 in. overlap onto the membrane below. It will be necessary to cut the membrane at the location of the anchors projecting from the wall to enable the sheet to be laid in place. End laps that occur in subsequent lengths that follow should maintain a minimum overlap of 2 in. (51 mm). To prevent water from migrating under the membrane, all membrane must be pressed firmly into place with a hand roller or the back of a utility knife as soon as possible, ensuring continuous and intimate contact with the substrate. In certain applications such as on soffits or ceilings, back-nail the membrane along the side lap prior to installing/overlapping the next sheet of membrane. Alternately install a termination bar that spans the soffit to ensure positive contact to the substrate. Apply BITUTHENE Liquid Membrane, BITUTHENE Mastic or compatible sealant to seal around the anchors. Fit the PERM-A-BARRIER VPS product tightly around all penetrations through the membrane and seal using compatible sealant. Continue the membrane into all openings in the wall area, such as windows, doors, etc., and terminate at points that will prevent interior visibility. The installation must be made continuous at all framed openings, such as windows, doors, etc. Flash framed openings with PERM-A-BARRIER Detail Membrane and overlap onto PERM-A-BARRIER VPS product in a shingled water shedding manner. Coordinate installation of the PERM-A-BARRIER VPS product with the roofing trade to ensure continuity with the roofing system at this critical transition area. At the end of each working day, if the wall has been only partially covered, apply a bead of BITUTHENE Liquid Membrane, BITUTHENE Mastic or compatible sealant along the top edge of the membrane at its termination to prevent vertical drainage of precipitation from penetrating the end and undermining the membrane adhesion. Tool the compatible sealant to ensure it is worked into the surface. Inspect the membrane before covering and repair any punctures, damaged areas or inadequately lapped seams. Membrane Protection PERM-A-BARRIER VPS membrane must be protected from damage by other trades or construction materials. All damaged areas must be repaired. Membrane Repairs All punctures, rips, tears or other discontinuities in the membrane must be repaired. Repairs must be made using PERM-A-BARRIER VPS product sized to extend 6 in. (150 mm) in all directions from the perimeter of the affected area. Prior to repair, any loose, unbounded or unsound membrane should be removed. Carefully cut out affected areas, re-prime the base substrate and replace in similar procedure as outlined in the text above. The repair piece must be pressed into place with a hand roller as soon as possible to ensure continuous and intimate contact with the substrate. Apply a bead of compatible sealant

along the top edge of the repair piece. Note For complete application instructions and a review of the most recent product information, it is important that you refer to the current GCP Applied Technologies literature on www.gcpat.com. There you will find the currently applicable Product Data Sheets and Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents. Documents in hardcopy as well as information found on other websites should not be relied on, as they may be out of date or in error. If there are any conflicts or if you need more information, please contact GCP Customer service: 1-866-333-3SBM (3726). Supply PRODUCT UNIT OF SALE APPROXIMATE COVERAGE WEIGHT PALLETIZATION PERM-A-BARRIER VPS 1 roll 450 2 (41.8 m2) / roll 38.4 in x 141 (1.0 m x 43 m) 28.7 lbs/roll 25 cartons (25 rolls) / pallet Note: Units of sale for Ancillary products can be found on individual product webpages at gcpat.com Typical Performance Properties TEST TYPICAL VALUE METHOD Color White Air permeance at test pressure of 1.57 psf (75 Pa) < 0.02 L/s/m 2 (0.004cfm/ 2) ASTM E2178 Assembly air permeance at test pressure of 1.57 psf (75 Pa) < 0.2 L/s/m 2 (0.04cfm/ 2) ASTM E2357 Water vapor permeance Minimum 10 perms, Method A, Dry Cup Minimum 10 perms, Method B, Wet Cup ASTM E96 Water resistance Pass ICC - AC38 Peel strength @ minimum temperature Pull adhesion Breaking force > 5 pli to primed exterior gypsum board 4 pli to PERM-A-BARRIER VPS > 2.5 pli to primed CMU > 15 psi to primed exterior gypsum board > 12 psi to primed CMU > 40 lbs, Machine Direction > 35 lbs, Cross Direction ASTM D903 ASTM D4541 ASTM D5034 Low temperature flexibility Pass ASTM D1970 Water penetration resistance around nails Pass ASTM D1970 Surface Burning Characteristics Flame Spread Index, Class A Smoke Developed Index, Class A ASTM E84 Wall assembly fire test Pass as part of various wall assemblies with foam plastic insulation NFPA 285 North America customer service: 1-877-4AD-MIX (1-877-423-6491) We hope the information here will be helpful. It is based on data and knowledge considered to be true and accurate, and is offered for consideration, investigation and verification by the user, but we do not warrant the results to be obtained. Please read all statements, recommendations, and suggestions in conjunction with our conditions of sale, which apply to all goods supplied by us. No statement, recommendation, or suggestion is intended for any use that would infringe any patent, copyright, or other third party right. BITUTHENE and PERM-A-BARRIER are trademarks, which may be registered in the United States and/or other countries, of GCP Applied Technologies Inc. This trademark list has been compiled using available published information as of the publication date and may not accurately reflect current trademark

ownership or status. Copyright 2018 GCP Applied Technologies Inc. All rights reserved. GCP Applied Technologies Inc., 62 Whittemore Avenue, Cambridge, MA 02140 USA. In Canada, GCP Canada Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6. This document is only current as of the last updated date stated below and is valid only for use in the United States. It is important that you always refer to the currently available information at the URL below to provide the most current product information at the time of use. Additional literature such as Contractor Manuals, Technical Bulletins, Detail Drawings and detailing recommendations and other relevant documents are also available on www.gcpat.com. Information found on other websites must not be relied upon, as they may not be up-to-date or applicable to the conditions in your location and we do not accept any responsibility for their content. If there are any conflicts or if you need more information, please contact GCP Customer Service. Last Updated: 2018-06-01 gcpat.com/solutions/products/perm-a-barrier-air-barrier-system/perm-a-barrier-vps-0