SLOPED ROOF. Ajustable sloped flashing from : 2/12 to 7/12 Ventilation area : 50 to 250 ft. 2

Similar documents
Roof e Flat r xhaust trap oof ventilators 4 models for FLAT ROOF

models for INDUSTRIAL AND COMMERCIAL

AIR INTAKE VENTS. Special air intake Models for

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

BASIC VENTILATION REQUIREMENTS

SECTION TURBINE VENTILATORS

TAMKO VENTILATION PRODUCTS

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR

Malarkey s well-designed, competitively-priced Endura products can assist with completing projects ON TIME AND ON BUDGET.

CONTINUOUS VENTILATORS

LANDMARK SERIES. Designer Roofing Shingles. Landmark, shown in Weathered Wood

Effective Date: Jan. 1, 2016 DURAFLO SECTION ROOF VENTS WE KNOW VENTILATION

PRESIDENTIAL SERIES. Luxury Roofing Shingles. Presidential Shake, shown in Autumn Blend

NORTHGATE. Designer Roofing Shingles. NorthGate, shown in Max Def Moire Black

O HAGIN ATTIC VENTILATION PRODUCTS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE MOST RECENT BUILDING CODES FOR ATTIC VENTILATION

RIDGE VENTILATION. Build Better

PRESIDENTIAL SERIES. Luxury Roofing Shingles. Presidential Shake, shown in Autumn Blend

Architectural Roof Products Guide Specifications

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOF PANELS REPORT HOLDER: ONDULINE NORTH AMERICA, INC. EVALUATION SUBJECT:

LANDMARK SERIES DESIGNER ROOFING SHINGLES. Landmark, shown in Silver Birch

Siding and Soffit Installation Guidelines

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

New versatile and effective dry fix solutions for the roofline and above

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

LANDMARK SERIES. Designer Roofing Shingles. Landmark, shown in Weathered Wood

PRESIDENTIAL SERIES. Luxury Roofing Shingles. Presidential Shake, shown in Autumn Blend

VISUM3. One tile creates the visual effect of three

MILLENNIUM METALS, INC TEST REPORT

CertainTeed. Luxury Shingles. Shown in Autumn Blend

SECTION METAL ROOF AND SOFFIT PANELS

Siding and Soffit Installation Guidelines

Architectural Roof Products Guide Specifications

APPLICABLE UNDER SECTIONS: SOLAR ENERGY HEATING EQUIPMENT SOLAR HEATING COLLECTORS METAL WALL PANELS

Architectural Roof and Wall Products Guide Specifications

Architectural Wall Products Guide Specifications

PRESIDENTIAL SERIES. Luxury Roofing Shingles. Presidential Shake, shown in Autumn Blend

CARRIAGE HOUSE. Luxury Roofing Shingles. Carriage House, shown in Georgian Brick

CBUCK Engineering. Wood Deck

RECREATIONAL EAGLE CENTER METAL ROOF ASSESSMENT AND SOLUTION

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

CertainTeed. Luxury Shingles. Shown in Shadow Gray

Deck Armor Brochure. Updated: 1/12.

LANDMARK TL. Luxury Roofing Shingles Triple Laminate. Landmark TL, shown in Shenandoah

SECTION R327.3 STANDARDS OF QUALITY

Presidential Series LUXURY SHINGLES. Shown in Presidential Shake Autumn Blend

Louvers Selection, Design Considerations and Details Written by Matt Trentham, R.L. Craig Company, Inc.

CertainTeed. Luxury Shingles. Shown in Shenandoah

LOG COLLEGE MIDDLE SCHOOL

The better way to build TM. Installation Manual NAILBASE PANELS

CertainTeed. Luxury Shingles. Shown in Autumn Blend

Original Scandinavian rainwater system

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SRP-AirOutshield ROOF Issued:

CertainTeed. Designer and Luxury Shingles. Shown in Landmark Weathered Wood

Our buildings are manufactured entirely in the United States with a 25 year steel mill backed guarantee.

ICC-ES Report OR-4, AND MOISTURE DIVISION: SECTION: SECTION: Reissued 11/2017 This. Report Holder:

SECTION ROOF ACCESSORIES

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

NORTHGATE. Designer Roofing Shingles. Shown in Max Def Moire Black

CBUCK Engineering. Evaluation Report MI Off Ridge Vent Ridge Vent Assembly

LANDMARK SERIES. Luxury & Designer Roofing Shingles. Landmark, shown in Weathered Wood

SECTION STRUCTURAL RETROFIT ROOF SUB-FRAMING SYSTEM

DL-200. Specifications

Onduline covers the world. More than 100 countries across the globe

SSL-175. Specifications

Artisan Colors. Shingles. Oakridge. featuring. featuring. Oakridge. Shingles are a component of the Owens Corning Total Protection Roofing System.

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

VISUM3. One tile creates the visual effect of three

CertainTeed. Designer and Luxury Shingles. Shown in Landmark Weathered Wood

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Peel & Seal Self-Stick Roofing Solutions

PLANUM. The essence of a traditional material for today s architectural language

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

Fiber Cement Collection. AlluraUSA.com

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue Oroville, CA Office (530)

SECTION 7307 ASPHALT SHINGLE ROOF UNDERLAYMENT

VP ROOF SYSTEMS SSR ROOF SYSTEM. WEATHERTIGHT PERFORMANCE FOR low-slope ROOF APPLICATIONS

Shown in Landmark Weathered Wood

Peel & Seal Self-Stick Roofing Solutions

RESIDENTIAL ROOFING PRODUCT GUIDE

CERAMIC ROOF SOLUTIONS

Weather Resistant Barrier

A Guardian Roof makes all the difference. The ultimate solution for new or existing conservatories

INNISGLEN CONDOMINIUMS, BELLEVUE, WASHINGTON LIMITED ROOF EXAMINATION EXECUTIVE SUMMARY

Pol-E-Base Modified Bitumen Roof System

Made in Dade... we ve built the world s strongest garage doors since 1998.

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS DAVIS, CALIFORNIA

Sapphire Metal Tile Roofing System

TOTAL PRICE FOB ORIGIN:

Bituminous Building Paper

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

Architectural Roof and Wall Products Guide Specifications

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

Building with Ducts in Conditioned Spaces Conditioned Attics

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

Transcription:

Sloped Roof exhaust roof ventilators trap 6 models for SLOPED ROOF Model VMAX-302-8 Ajustable sloped flashing from : 2/12 to 7/12 Ventilation area : 50 to 250 ft. 2 Model VMAX-302-12 Ajustable sloped flashing from : 2/12 to 15/12 Ventilation area : 400 to 500 ft. 2 Model VMAX-303-12 Ajustable sloped flashing from : 2/12 to 15/12 Ventilation area : 700 to 800 ft. 2 Model VMAX-301-12 Ajustable sloped flashing from : 2/12 to 15/12 Ventilation area : 1000 to 1200 ft. 2 Model VMAX-401-12 Replacement head for any 12 in. round ventilator. Adaptor : Sold seperately for 10 & 14 in. units Ventilation area : 800 to 1000 ft. 2 Model Cathedral System Special order : Custom made to the slope of the roof. An insulated duct is installed on the ridge of the roof, to assure an efficient ventilation between the joists of the roof. Features Unique storm proof deflector Exceptional drawing power Built-in wire mesh screen Adjustable flashing for slopes from 2/12 to 15/12 Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.

Roof exhaust trap Sloped roof ventilators MODEL VMAX-302-8 Description Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as 6 km./hr. (4 mi./hr.). With this combination of technology, wind and pressure differentials, a chimney or, vacuum effect results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space. The model VMAX-302-8 has been designed for slope roof application varying from a 2/12 to 7/12 pitch. This ventilator was designed for the application on smaller roofs such as sunrooms, extensions, etc., where the aesthetics as well as efficiency is important. Has no moving parts, requires no electricity, it is completely silent and maintenance free. Built tough to endure the harshest weather conditions that nature has to offer including hail storms. It sits high enough off the roof deck to allow it to weather through snow accumulations without being covered, thus, finally giving the home owner a peace of mind. Specifications & Features A limited selection of special colours are available at a small premium. Please refer to chart 302-12 for larger dimensions that are available by special order. Model : VMAX-302-8 Deflector : 1 Net Free Evacuation : 64 in. 2 Suggested Ventilation Area : 50 to 250 ft. 2 Adjustable Flashing : 2/12 to 7/12 Storm Proof : Unique precision engineered deflector system Solid : Built of galvanized steel Standard Gauge : & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown, grey Compliances : CSA, CAN-3-A930M82, ASTM-527

Sloped Roof exhaust roof ventilators trap MODEL VMAX-302-12 Description Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind from all directions and at velocities as low as 6 km./hr. (4 mi./hr.). With this combination of technology, wind and pressure differentials, a chimney effect results in drawing the stale air and moisture out of the attic space, while replacing it with fresh new air that enters through the soffits. The model VMAX-302-12 has been designed for slope roof application and is compatible with most all types of roofing membrane including metal. It has no moving parts, requires no electricity, and is completely silent and maintenance free. Built tough to endure the harshest weather conditions that nature has to offer including hail storms. It sits high enough off the roof deck to allow it to weather through snow accumulations without being covered, thus, finally giving the home owner a peace of mind. Specifications & Features A limited selection of special colours are available at a small premium. Please refer to chart on the following page for larger dimensions that are available by special order. Model : VMAX-302-12 Deflector : 1 Net Free Evacuation : 96 in. 2 Tested Extraction Rate : 134 CFM Suggested Ventilation Area : 400 to 500 ft. 2 Adjustable Flashing : 2/12 to 15/12 Storm Proof : Unique precision engineered deflector system Solid : Built of galvanized steel Standard Gauge : & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown, grey Compliances : CSA, CAN-3-A930M82, ASTM-527

Roof exhaust trap Sloped roof ventilators DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on recommendations for slope roofs for additional information. B CODE# DIMENSIONS A B C D EVACUATION NUMBER OF DEFLECTORS STEEL GAUGE USED 302-8 8 13 5 8 64 IN. 2 1 26 METRIC (mm) 203 330 127 203 0.0412 M. 2 26 C 302-12 12 19.75 5 10.375 96 IN. 2 1 26 305 502 127 263.5 0.062 M. 2 26 302-14 14 6.50 17.5 150 IN. 2 1 D 302-16 356 610 165 445 16 26 6.50 17.50 0.097 M. 2 208 IN. 2 1 406 660 165 445 0.134 M. 2 A 302-18 18 28 6.50 17.50 266 IN. 2 1 457 711 165 445 0.172 M. 2 302-20 20 32 9.50 16 352 IN. 2 1 508 813 1 406 0.227 M. 2 302-22 22 34 9.50 16 408 IN. 2 1 559 864 1 406 0.263 M. 2 302-36 9.50 16 486 IN. 2 1 610 914 1 406 0.314 M. 2 The models #302-14 to #302- are available by special orders only. Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.

Sloped Roof exhaust roof ventilators trap MODEL VMAX-303-12 Description Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind from all directions and at velocities as low as 6 km./hr. (4 mi./hr.). With this combination of technology, wind and pressure differentials, a chimney effect results in drawing the stale air and moisture out of the attic space, while replacing it with fresh new air that enters through the soffits. The model VMAX-303-12 has been designed for slope roof application and is compatible with most all types of roofing membrane including metal. It has no moving parts, requires no electricity, and is completely silent and maintenance free. Built tough to endure the harshest weather conditions that nature has to offer including hail storms. It sits high enough off the roof deck to allow it to weather through snow accumulations without being covered, thus, finally giving the home owner a peace of mind. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX-303-12 Deflectors : 3 Net Free Evacuation : 105 in. 2 Tested Extraction Rate : 266 CFM Suggested Ventilation Area : 700 to 800 ft. 2 Adjustable Flashing : 2/12 to 15/12 Storm Proof : Unique precision engineered deflector system Solid : Built of galvanized steel Standard Gauge : & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown, grey Compliances : CSA, CAN-3-A930M82, ASTM-527

Roof exhaust trap Sloped roof ventilators MODEL VMAX-301-12 Description Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations, even withstanding hurricane wind and rain conditions of 175 km./ hr. or 110 mi/hr. Its unique storm proof system prevents infiltrations, while at the same time capturing the wind from all directions and at velocities as low as 6 km./hr. (4 mi./hr.). With this combination of technology, wind and pressure differentials, a chimney effect results in drawing the stale air and moisture out of the attic space, while replacing it with fresh new air that enters through the soffits. The model VMAX-301-12 has been designed for slope roof application and is compatible with most all types of roofing membrane including metal. It has no moving parts, requires no electricity, and is completely silent and maintenance free. Built tough to endure the harshest weather conditions that nature has to offer including hail storms. It sits high enough off the roof deck to allow it to weather through snow accumulations before being covered, thus, finally giving the home owner a peace of mind. Specifications & Features A limited selection of special colours are available at a small premium. Please refer to chart on the following page for larger dimensions that are available by special order. Model : VMAX-301-12 Deflectors: 4 Net Free Evacuation : 144 in. 2 Tested Extraction Rate : 418 CFM Suggested Ventilation Area : 1000 to 1200 ft. 2 Adjustable Flashing : 2/12 to 15/12 Storm Proof : Unique precision engineered deflector system Solid : Built of galvanized steel Standard Gauge : & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown, grey Compliances : CSA, CAN-3-A930M82, ASTM-527, Miami Dade approved, ICC-ES

Sloped Roof exhaust roof ventilators trap DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on recommendations for slope roofs for additional information. CODE# DIMENSIONS A B C D EVACUATION NUMBER OF DEFLECTORS STEEL GAUGE USED B 301-12 12 19.50 11 8.625 144 IN. 2 4 &26 METRIC (mm) 305 495 279 219 0.093 M. 2 &26 301-14 14 21.50 11 16.25 196 IN. 2 4 356 546 279 413 0.126 M. 2 C 301-16 16 23.50 13.25 16.25 256 IN. 2 5 406 597 337 413 0.165 M. 2 301-18 18 25.50 13.25 16.25 3 IN. 2 5 457 648 337 413 0.209 M. 2 A D 301-20 20 27.50 508 699 15.75 16.25 400 413 400 IN. 2 0.258 M. 2 6 301-22 22 29.50 15.75 16.25 484 IN. 2 6 559 749 400 413 0.312 M. 2 301-31.50 18.50 16.25 576 IN. 2 7 610 800 470 413 0.372 M. 2 The models #301-14 to #301- are available by special orders only. Fabrication starts once we receive the order which can then take anywhere between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.

Roof exhaust trap Sloped roof ventilators MODEL VMAX-401-12 Description Unlike the turbine, the Maximum Ventilators are CSA approved and do not require to rotate to prevent water or snow infiltrations. Its unique storm proof system prevents infiltrations while at the same time capturing the wind flow from all directions and at wind velocities as low as 6 km./hr. (4 mi./hr.). With this combination of technology, wind and pressure differentials, a chimney or, vacuum effect results in drawing the stale air and moisture out, thus preventing moisture & heat build-up within the attic space. This ventilator has been designed to replace faulty turbines of 12 in. diameters but can also replace a 10 in. or 14 in. turbines by installing an adaptor that can be ordered separately. No need of removing or replacing the shingles, allows for fast and easy installation. Specifications & Features A limited selection of special colours are available at a small premium. Model : VMAX-401-12 Deflectors : 4 Net Free Evacuation : 113 in. 2 Suggested Ventilation Area : 800 to 1000 ft. 2 Storm Proof : Unique precision engineered deflector system Solid : Built of galvanized steel Standard Gauge : & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown, grey Compliances : CSA, CAN-3-A930M82, ASTM-527

Sloped Roof exhaust roof ventilators trap MODEL CATHEDRAL SYSTEM Description Ventilation Maximum designed and engineered a ventilation system in combination with the VMAX-301-12 ventilator that will allow, due to the ventilators exceptional drawing power, to draw fresh air from the soffits up between each rafter (between the insulation and underside of the roof deck) into an assembled weather tight duct system. It will then be extracted out the ventilator, thus, allowing for continuous fresh air flow throughout the attic space and preventing heat and moisture buildup from deteriorating the structural integrity of the building & its components. Another valuable feature to this system is that it has been designed and developed to withstand the harshest weather conditions that Mother Nature could offer including hail & snow accumulations, thus, finally, giving the home owner peace of mind. A limited selection of special colours are available at a small premium. This system is costumed made to your specifications, the slope of the roof (both sides if they are not the same), the length, as well as colour is required for fabrication. Self-tapping screws are included with this system for assembly of parts, however, is the responsibility of the end user to supply the screws to secure to the roof deck. Specifications & Features Model : Cathedral system Storm Proof : Unique precision engineered deflector system Solid : Built of galvanized steel Standard Gauge : & 26 Rodent Proof : Built-in galvanized wire mesh screen Finish : Interior and exterior powder coated polyester baked paint with UV protection Warranty : Limited Lifetime Warranty on all manufacturing defects, 5 years on paint & corrosion Available Colours : Black, brown, grey Compliances : CSA, CAN-3-A930M82, ASTM-527

Roof exhaust trap Sloped roof ventilators DIMENSIONS AND SPECIAL CHARACTERISTICS Please refer to the section on recommendations for slope roofs for additional information. ITEM TYPE A DUCT Made of gauge galvanized steel. The duct is insulated, painted and perforated on its sides so as to facilitate its attachment to roof deck. Each section measures 48 long, but 2 are used to overlap the next section thus leaving 46 per section. N.B. The slope of the roof is required to order this product. VENTILATOR For standard residential buildings, a Maximum ventilator is installed for no more than 20 feet of duct. The distance between the ventilators may need to be reduced for buildings which exceed the size of standard residences. ADAPTOR The adaptor is used to connect the ventilator with the duct. One adaptor is needed per ventilator and the adaptors are all insulated, painted and perforated. END CAPS The caps are used to close off the extremities of the duct and each unit is composed of two pieces. Two caps are usually needed per installation. Fabrication starts once we receive the order which can then take between two (2) to three (3) weeks delivery depending on your location and season. We recommend, so as to not delay your projects, that you place these orders in conjunction with these delays before starting a job. Warning : Before venting an attic space, make sure that the building in question complies with the Building Code Requirements.

Sloped Roof exhaust roof extensions trap The Maximum ventilator EXTENSIONS CODE # DESCRIPTION Gauge EXT-12 metric (mm) EXT-18 EXT- EXT-30 EXT-36 EXT-42 EXT-48 EXT-54 EXT-60 EXT-66 EXT-72 Extension 12 high 305 mm Extension 18 high 457 mm Extension high 610 mm Extension 30 high 762 mm Extension 36 high 914 mm Extension 42 high 1067 mm Extension 48 high 1219 mm Extension 54 high 1372 mm Extension 60 high 15 mm Extension 66 high 1676 mm Extension 72 high 1829 mm 22 22 22 22 Special orders only. Manufacturing delays may vary depending on season. Available Colours : Black, brown and grey. A limited selection of special colours are available at a small premium. Please visit our web site at. Please note that we can manufacture all other dimensions on request. N.B. Support Brackets are available for extensions three (3) feet and higher at a small premium

Roof exhaust trap Sloped roof ridge flashing The Maximum ventilator RIDGE FLASHING Description : This special flashing is installed directly on the ridge of the roof allowing for a perfect balance of ventilation and extra height for the heavy snow regions or forest areas. It allows for a fast and easy installation onto any roofing materials whether it be asphalt shingles or metal roofs. It can be manufactured to fit all dimensions, and can be made of any raw metal of your choice. When ordering this flashing, the slope is required. Manufacturing delays may vary depending on season. Available Colours: Black, brown, or grey. A limited selection of special colours are available at a small premium. Please visit our web site at.