HAMBRO COMPOSITE FLOOR SYSTEM

Similar documents
HAMBRO COMPOSITE FLOOR SYSTEM

D500TM. SPC No ( )

MULTI-RESIDENTIAL BUILDING SOLUTIONS

UL-listed fire ratings 1, 2 and 3 hours Excellent sound ratings STC and IIC Manufactured from recycled steel. 48" to 72" joist spacing, longer spans

The Perfect Choice for Mezzanines in Custom Metal Buildings

Structural Technical Report #2 By Robert Whitaker

Union County Vocational - Technical Schools Scotch Plains, New Jersey

STEEL STRUCTURAL SYSTEMS

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

DIAPHRAGM ACTION AT THE ROOF LEVEL: USE OF STEEL DECK IN LATERAL LOAD RESISTING SYSTEM AND THE ROLE OF DIAPHRAGM. By Pierre Gignac, P.Eng.

AISC Steel & Timber Research for High-Rise Residential Buildings

Prefabricated Light Weight Steel Structures. Systems Guide WALLS, FLOORS, TRUSSES

SECTION COMPOSITE METAL DECKING

ENGINEERS ENGINEERED SOLUTIONS DEEP-DEK COMPOSITE COMPOSITE LONG SPAN FLOOR DECK.

Smarter. Safer. Leaner.

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

Interior Hangers. Application

North Shore at Canton Baltimore, MD Beau Menard Technical Report 1

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION COLD-FORMED METAL FRAMING

SECTION COLD-FORMED METAL FRAMING

TCC Systems. Timber-Concrete Composite TIMBER IMAGINEERING INNOVATIVE TIMBER SOLUTIONS

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

PRESENTATION PLAN A MODEL COMPARISON FLOOR CONSTRUCTION

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

SECTION NON-STRUCTURAL METAL FRAMING

EVALUATION OF JOISTS AND THEIR TYPICAL REINFORCEMENT IN STEEL- FRAMED BUILDINGS: SUGGESTIONS OF JOIST MEMBERS REINFORCEMENT

Danielle Shetler - Structural option Courtyard by Marriott Lancaster, PA

A division of Canam Group

151 First Side. Technical Assignment 2 November 16 th, William J. Buchko. AE 481w Senior Thesis The Pennsylvania State University

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

SECTION COMPOSITE METAL DECKING

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

SECTION NON-STRUCTURAL METAL FRAMING

SECTION STEEL DECKING

3.4.2 DESIGN CONSIDERATIONS

Issue Date: April 2003 Release: I. Product Specifications

Thesis Proposal Structural Redesign / Cost, Schedule and Coordination Analysis / Architectural Impact

Cavity ShAftwall System

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

SECTION NON--STRUCTURAL METAL FRAMING

SECTION COLD-FORMED METAL FRAMING

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

WOOD I-JOIST AWARENESS GUIDE

Structural Technical Report #2 Pro/Con Study of Alternate Floor Systems

OF THREE NEW BUILDINGS BEING CONSTRUCTED TO REPLACE THE EXISTING COMPLEX. THE FLOOR SYSTEM OF GEORGE READ HALL IS A HAMBRO COMPOSITE SYSTEM

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

MASTER GUIDE SPECIFICATION

BEARING METAL STUD FRAMING

Statement of Special Inspections

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

Potential Solutions- Background: Current Designs. Potential Solutions. Goals for Design What are we concerned about?

Metal Web Floor System

SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series

Pro-Con Structural Study of Alternate Floor Systems

Garage Beam System DAYTONSUPERIOR.COM FORMING. For Post-Tensioned Beam and Slab Parking Structures

EDGEWATER, FLORIDA JUNE 14, 2010

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

Product Specification

DEEP-DEK COMPOSITE A VERSA-FLOOR SYSTEM

STEEL DECK INSTITUTE Industry Standard Terms & Definitions

Campus Square Buildings C & D Lehigh University, Bethlehem, PA

Industry Standard Terms & Definitions Of The Steel Deck Institute

Sound Insulation Quality Thermal Insulation Fire Resistant Hebel PowerFloor

Jonathan R. Torch Technical Report 2 Columbia University. Technical Report 2. Pro-Con Structural Study of Alternate Floor Systems

Building with Insul-Deck Floor & Roof System

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

FrameFast Shoring System

Matthew Kutzler. Structural Option Spring Buildings C and D Campus Square, Lehigh University Bethlehem, PA

HAMBRO COMPOSITE FLOOR SYSTEM. Technical Manual CANADA

ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS

SECTION COLD-FORMED METAL TRUSSES

HAMBRO COMPOSITE FLOOR SYSTEM. Technical Manual CANADA

Exton, PA FUTURE C.1 C.2. as followed: C.2.1 C.2.2 C.2.3. Page 68. Solution. Proposed. Page 69. Sean. of 147. Page 67

TECHNICAL EVALUATION REPORT No. 27/2008/2060

BIG IDEAS BETTER SOLUTIONS. Metwood Patents and Design Certificates

Polycrete Big Block Standard Specification

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

These systems are evaluated on the basis of serviceability issues such as:

Stephan Northrop Structural Option Dr. Linda Hanagan. North Shore Equitable Building Pittsburgh, PA Senior Thesis Proposal

DIVISION 5 METALS SECTION METAL DECKING

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

AREMA 2008 Annual Conference. LOW PROFILE RAILROAD BRIDGE Steve K. Jacobsen, PE NNW, Inc. Rochester, Minnesota

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, UNIFORM EVALUATION SERVICES

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, UNIFORM EVALUATION SERVICES

Insulated Concrete Forms (ICFs)

Soundmaster & Modernfold TECHNICAL DATA

LISTING INFORMATION OF CCI Manufacturing Inc. - HiBAR SPEC ID: CCI Manufacturing Inc Ave. Edmonton, AB T5V 1K5 Canada

Transcription:

HAMBRO COMPOSITE FLOOR SYSTEM

OUR EXPERTISE AT YOUR SERVICE Canam has been offering owners, real estate developers, architects, engineers and contractors an array of construction solutions since 1970. Our products include the Hambro D500 TM and MD2000 composite floor systems, a composite girder and a transfer slab system, all of which can be combined in order to design multi-residential buildings that are both better adapted and more functional. Hambro products can be used on their own or interfaced with other Canam components in order to form the entire building envelope. Canam also offers a full range of complementary services, including virtual design and construction, building information modeling (BIM) and technical drafting. With its BuildMaster approach, Canam has redefined the way buildings are designed and built. BuildMaster applies a safer, faster and more collaborative approach allowing you to shorten your structural erection schedule by 15 to 25%. HAMBRO COMPOSITE FLOOR SYSTEM The Hambro composite steel joist system is primarily designed for residential and multi-residential projects, and is an advanced up-to-date answer for the elevated floor construction challenges. Spans [up to 43 ft. (13,1 m)] and large web openings that enable passage of various mechanical systems such as HVAC, electrical and plumbing components, thus allowing for higher ceilings and large uninterrupted spans. D500 The D500 joist system utilizes reusable plywood forms, to be reused on the multiple stories, and require striping. The speed of installation of this system, mainly used on load-bearing wall construction allows it to be quickly accessible for other trades. It is strongly recommended by builders. MD2000 The MD2000 joist system utilizes steel deck as a permanent form that does not require stripping, allowing it to be quickly available for other trades. This system is ideal for multi-story buildings consisting of conventional structural steel frame (beams and columns) as it enables the concrete pouring of more than one floor at a time. It is highly recommended by steel erectors. BENEFITS Fire resistance The Hambro system complies with UL/ULC/cUL standards. Maximum duct opening Facilitates the integration of mechanical systems. Long spans Hambro joists can span up to 43 ft. (13.1 m) without shoring. Rigidity and strength Enhanced strenght due to composite action between the steel and concrete. Acoustical properties STC up to 57 / IIC up to 30 Versatility Applicable to all types of framing. Economical Requires less concrete and steel reinforcement than conventional slabs, which cuts costs and overall construction time. Service Design assistance, value engineering and fast delivery. Custom design Products are designed according to the specific load requirements of each project. Simplicity Fast and simple to install. 2

THE HAMBRO D500 COMPOSITE SYSTEM IDEAL ON LOAD-BEARING WALLS The Hambro D500 composite floor system can be successfully combined with load-bearing walls made of light gauge steel, wood, concrete block and masonry as well as with structural steel. Ideal for the construction of multi-residential, mixed-use, commercial buildings and single-family homes. Your satisfaction with this versatile product is assured. Minimum width of plywood forms is 1 ft. (305 mm), cut parallel to the grain Concrete slab Wall supporting the joists Flange hanger Joist shoe Reusable 4 ft. x 8 ft. (1,220 mm x 2,440 mm) plywood forms Slots in top chord to support rollbars (chord cut for drawing clarity) Rollbar clips for temporary bottom chord bridging Section A (see below) Interior supports Rollbar (rotated into a locked position in the joist) to support plywood forms Cold-rolled top chord embedded 1½ in. (38 mm) in the concrete slab to achieve composite action Plywood form Rollbar handle Welded wire mesh draped over joists Note: Plywood forms are removed after rotating and removing the rollbars. Section A By combining Hambro steel joists with the poured concrete, the system forms composite T-beams that are integrated in the transversally reinforced continuous slab. The bottom chord acts as a tension member during the concreting process while the web systems, which are made from bent rods, serve to resist vertical shear. The top chord withstands compressive action during the non-composite stage and subsequently functions as a continuous shear connector between the steel and concrete through adhesion and friction. The slab is reinforced with welded wire mesh. The reinforced concrete slab also contributes to the transfer of horizontal loads (wind, seismic activity) and acts to stiffen multi-story buildings. 3

FAST AND ECONOMICAL INSTALLATION 1- Positioning of joists The joists are placed on the walls or beams and positioned in compliance with the drawings issued for construction by Canam. The joist connection methods are also shown on the Canam drawings. 2- Rollbars The rollbars are designed to support the plywood forms and concrete construction load. When rotated and locked into the notches in the top chord, the rollbars lock the joists in place while providing lateral and torsional stability to the joists. Bottom chords are fabricated with clips to accommodate rollbars if temporary bridging is needed during the pouring process. Generally, no permanent bridging or shoring is required unless specifically noted. 3- Plywood forms Together, the plywood and the rollbars form a rigid diaphragm during construction, providing a safe platform for workers. The Hambro system uses standard 4 ft. x 8 ft. x ½ in.* (1,200 mm x 2,400 mm x 13 mm*) plywood sheets. * Subject to change; refer to erection drawings. 4- Sheets of mesh Welded wire mesh serves as the standard catenary for the slab. Standard 8 ft. x 20 ft. (2,400 mm x 6,100 mm) sheets of mesh are easily placed over the top chords of the Hambro joists. The top chord acts as a high chair. 5- Concrete pouring and finishing When pouring and finishing a Hambro slab, it is not necessary to complete the entire deck in a single pour. In the event that the pour is interrupted parallel to the joists, the joint should be midway between the joists, but never less than 6 in. (152 mm) from the top chord in order to ensure composite action. 6- Removal of plywood forms When the concrete attains a cylinder strength of 500 psi (3.5 MPa), the rollbars and plywood forms can be removed. When the concrete attains a cylinder strength of 1,000 psi (7 MPa), the floor is ready but care must be taken not to surpass the admissible loads for the specified capacity. 4

TECHNICAL DETAILS D500 D500 Clear Span Table Typical Bearing Detail Residential and light commercial applications Slab thickness 3 to 4 in. (75 to 100 mm) DL = 67 to 78 psf (3.2 to 3.7 kpa) Typical load LL = 40 and 50 psf (1.9 and 2.4 kpa) Minimum depth Maximum span 8 in. (200 mm) 20 ft. (6,100 mm) 10 in. (250 mm) 25 ft. (7,600 mm) 12 in. (300 mm) 30 ft. (9,100 mm) 14 in. (350 mm) 35 ft. (10,668 mm) 16 in. (400 mm) 38 ft. (11,582 mm) 18 in. (450 mm) 40 ft. (12,192 mm) 20 in. (500 mm) 43 ft. (13,100 mm) 22 in. (550 mm) 43 ft. (13,100 mm) 24 in. (600 mm) 43 ft. (13,100 mm) Note: Please contact us for any commercial applications where the loads exceed those presented in the table above. 4 in. (100 mm) Top bearing 1 ¾ in. (45 mm) ¼ in. (6 mm) Maximum Duct Openings P Joist depth P D S R in. mm in. mm in. mm in. mm in. mm 8 200 20 508 3 ½ 90 3 ½ 90 6 x 2 ½ 150 x 60 10 250 20 508 5 ½ 140 4 ½ 115 7 x 3 ¼ 180 x 80 12 300 24 610 7 ¼ 185 5 ¾ 145 9 x 4 ¼ 230 x 110 R S D 14 350 24 610 8 ½ 215 6 ¾ 170 9 ½ x 5 ¼ 11 x 4 ¼ 16 400 24 610 9 ½ 240 7 ½ 190 10 ½ x 5 ½ 13 x 4 18 450 24 610 10 ¼ 260 8 ¼ 210 11 x 6 ¼ 12 ½ x 5 20 500 24 610 11 280 9 225 12 x 6 ¼ 13 x 5 ½ 240 x 130 280 x 110 265 x 140 330 x 100 280 x 160 315 x 130 305 x 160 330 x 140 22 550 24 610 12 305 9 3 /8 240 12 x 7 ½ 14 x 5 ½ 305 x 190 355 x 140 24 600 24 610 12 3 /8 315 10 255 13 x 7 14 x 6 330 x 180 355 x 150 Note: The information provided herewith is for general information about Hambro products and is subject to change without notice following updates and improvements. Canam does not accept responsibility for improper use of this information. 5

THE HAMBRO MD2000 COMPOSITE SYSTEM IDEAL ON CONVENTIONAL STRUCTURAL STEEL FRAMING With its all-steel design, the MD2000 composite floor system is a solution to elevated floor construction challenges. It s ideal for buildings having a conventional structural steel (beams and columns) frame and it can also be installed on different structures. It is used for the construction of multi-residential, mixed-use and commercial buildings. Cell closure for steel deck Concrete slab Steel deck Joist shoe Bearing structure supporting the joist Clips for permanent bridging at top and bottom chords, if required Section A (see below) Permanent bridging at top and bottom chords, if required Welded wire mesh draped over joists Cold-rolled chord embedded 1½ in. (38 mm) in the concrete slab to achieve composite action Steel deck Top chord bridging, if required Section A Bottom chord bridging, if required By combining Hambro steel joists with the poured concrete, the system forms composite T-beams that are integrated in the transversally reinforced continuous slab. The bottom chord acts as a tension member during the concreting process while the web systems, which are made from bent rods, serve to resist vertical shear. The top chord withstands compressive action during the non-composite stage and subsequently functions as a continuous shear connector between the steel and concrete through adhesion and friction. The slab is reinforced with welded wire mesh. The reinforced concrete slab also contributes to the transfer of horizontal loads (wind, seismic activity) and acts to stiffen multi-story buildings. 6

FAST AND ECONOMICAL INSTALLATION 1- Positioning of joists The joists are placed on the walls or beams and positioned in compliance with the drawings issued for construction by Canam. The joist connection methods are also shown on the Canam drawings. 2- Permanent bridging bolted Permanent bridging are designed to support steel deck, concrete and construction load. When bolted in the top and botton chords, bridgings lock joist in place while providing lateral and torsional stabilities to the joist. Top and bottom chords are fabricated with clips to accommodate bridging, if needed during the puring process. Generally, no shoring is required unless specifically noted. 3- Steel deck Together, the steel deck and bridging form a rigid diaphragm during construction, providing a safe platform for workers. The MD2000 system uses steel deck P-3606 which is delivered in bundle to easier installation. 4- Sheets of mesh Welded wire mesh serves as the standard catenary for the slab. Standard 8 ft. x 20 ft. (2,400 mm x 6,100 mm) sheets of mesh are easily placed over the top chords of the Hambro joists. The top chord acts as a high chair. 5- Concrete pouring and finishing When pouring and finishing a Hambro slab, it is not necessary to complete the entire deck in a single pour. In the event that the pour is interrupted parallel to the joists, the joint should be midway between the joists, but never less than 6 in. (152 mm) from the top chord in order to ensure composite action. 7

TECHNICAL DETAILS MD2000 MD2000 Clear Span Table Typical Bearing Detail Slab thickness above steel deck Typical load Minimum depth Residential and light commercial applications 3 to 4 in. (75 to 100 mm) DL = 67 to 78 psf (3.2 to 3.7 kpa) LL = 40 and 50 psf (1.9 and 2.4 kpa) Maximum span 8 in. (200 mm) 20 ft. (6,100 mm) 10 in. (250 mm) 25 ft. (7,600 mm) 12 in. (300 mm) 30 ft. (9,100 mm) 14 in. (350 mm) 35 ft. (10,668 mm) 16 in. (400 mm) 38 ft. (11,582 mm) 18 in. (450 mm) 40 ft. (12,192 mm) 20 in. (500 mm) 43 ft. (13,100 mm) 22 in. (550 mm) 43 ft. (13,100 mm) 24 in. (600 mm) 43 ft. (13,100 mm) Top bearing 3 ½ in. (89 mm) ¼ in. (6 mm) 4 in. (100 mm) Note: Please contact us for any different loads or applications showed in the table above. Maximum Duct Openings P Joist depth P D S R R S D in. mm in. mm in. mm in. mm in. mm 8 200 20 508 4 100 4 100 6 x 3 150 x 75 10 250 20 508 6 150 5 125 7 x 4 175 x 100 12 300 24 610 8 200 6 150 9 x 5 225 x 125 14 350 24 610 9 225 7 175 9 ½ x 6 240 x 150 16 400 24 610 10 250 8 200 10 ½ x 6 ½ 265 x 165 18 450 24 610 11 280 8 ½ 216 11 x 7 280 x 175 20 500 24 610 11 ½ 292 9 225 12 x 7 310 x 175 22 550 24 610 12 300 9 ½ 240 12 x 8 310 x 200 24 600 24 610 12 ½ 315 10 250 13 x 8 330 x 200 * Valid for bottom chord depth of 1 ½ in. (38 mm) maximum. Note: The information provided herewith is for general information about Hambro products and is subject to change without notice following updates and improvements. Canam does not accept reponsibility for improper use of this information. 8

THE HAMBRO TRANSFER SLAB ALTERNATIVE TO REINFORCED CONCRETE SLABS The Hambro transfer slab is a floor system that transfers the loads of the superstructure located above the slab to the columns and walls beneath it. Designed by Canam, the Hambro transfer slab is composed of Hambro joists and girders that are in composite action with the concrete slab, making it an efficient and economical floor system, both fast and easy to install. This particular system is ideal for use atop underground parking levels and commercial spaces built in the scope of multi-residential or mixed-use projects. The transfer slab can be designed to support the load of multiple floors and also requires less concrete and steel reinforcement than a reinforced concrete slab, thus reducing costs as well as construction time given the absence of shoring. Concrete slab with wire mesh Hambro D500 joist Hambro composite girder LOAD DISTRIBUTION Bearing wall-to-girder Girder-to-girder Girder-to-concrete wall 9

CONNECTION DETAILS D500 joist and girder-to-wall connection D500 joist and girder-to-composite column connection D500 joist and girder-to-steel column connection Girder-to-girder connection 10

ACOUSTICAL PROPERTIES STC: The Hambro assemblies have a Sound Transmission Class up to 57*. STC is a rating that assigns a numerical value to the sound insulation provided by a partition separating rooms or areas. The rating is designed to match subjective impressions of the sound insulation provided against the sounds of speech, music, television, office machines and similar sources of airborne noise that are characteristic of offices and dwellings. IIC: The Hambro assemblies have an Impact Insulation Class up to 30*. IIC is a rating designed to measure the impact sound insulation provided by floor/ceiling construction. The IIC of any assembly is strongly affected by and dependent upon the type of floor finish for its resistance to impact noise transmission. * All results are based on laboratory testings with a drywall ceiling. Note: Laboratory tests were performed on a Hambro assembly consisting of a concrete slab, Hambro joists, metal furring channels and a drywall ceiling. Please consult your design team in order to determine the overall requirements of your project and the methods by which they will be achieved. FIRE-RESISTANCE RATING UP TO 3 HOURS Assemblies composed of the Hambro floor system and drywall ceilings were tested by independent laboratories. These assemblies were assigned the following ratings by Underwriters Laboratories Inc. (UL) and by Underwriters Laboratories of Canada (ULC) for gypsum board, suspended ceilings and sprayed protection systems. All references to these published ratings must mention the type of ceiling. See the updates made to these ratings in the ULC/UL fire-resistance directory. UL/ULC/ cul design no. Rating (hour) Slab thickness (in.) (mm) Ceiling Beam rating (hour) 1506 2 2 ½ 65 ½ in. (12.7 mm) gypsum board - 2 3 ½ 90 ½ in. (12.7 mm) gypsum board - 1518 1 ½ 2 ½ 65 ½ in. (12.7 mm) gypsum board 2 2 2 ¼ - 3 70 75 ½ in. (12.7 mm) gypsum board 2 1800 1 1 ½ - 2 2 ½ - 2 ¾ 65 70 76 89 Sprayed 1 G003 2 2 ½ 65 Suspended or panel - G213 2 3 75 Suspended or panel 2 3 4 100 Suspended or panel 3 G227 2 2 ½ 65 Suspended or panel 3 G228 2 3 ¼ 83 Suspended or panel 2 G229 2 3 75 Suspended or panel 2 3 4 100 Suspended or panel 3 G243 1 ½ 2 ¾ 70 Suspended or panel 1 ½ 2 3 ¼ 83 Suspended or panel 2 G401 4 2 ½ 65 Plaster - G524 1 2 2 ½* 65* ½ in. (12.7 mm) gypsum board 2 3 3 ½* 90* ½ in. (12.7 mm) gypsum board 3 G525 3 3 ¼ 83 5 /8 in. (15.9 mm) gypsum board 3 G702 1 2 3 Varies* Varies* Sprayed - G802 1 2 3 Varies* Varies* Sprayed - * Normal and lightweight concrete Furring channels are tie wired to the bottom chord of the Hambro joists. Fire-rated gypsum board completes the assembly, providing an attractive continuous ceiling. 11

BUILD DIFFERENTLY For more than 50 years, Canam has developed a fast, reliable construction method adapting to all your commercial, industrial, institutional or multi-residential projects. Whether you are building structures, floors, walls or steel building envelopes, our construction solutions are simple and straightforward. No surprises. 1-866-466-8769 canam-construction.com/hambro Hambro products are sold in Canada by Canam Group Inc. and in the United States by Canam Steel Corporation or through their respective agents, distributors or representatives in those countries. BuildMaster, Canam and Murox as well as all logos identifying the activities of Canam Group Inc. and its subsidiaries are trademark of Canam Group Inc. and its subsidiaries. Canam Group Inc., 2007-2015 Last modified 10-2015 Printed in Canada