TECHNICAL DATA SHEET SIKAFLEX FLOOR

Similar documents
TECHNICAL DATA SHEET SIKAFLEX PRO-3 SELF LEVELLING

One-part High Performance Sealant for Flooring

PRODUCT DATA SHEET Sikaflex PRO-3 WF

Sikaflex PRO-3 PROVISIONAL PRODUCT DATA SHEET HIGH-PERFORMANCE SEALANT FOR FLOOR JOINTS AND CIVIL ENGINEERING APPLICATIONS DESCRIPTION

Construction. 1-part floor joint sealant. Product Description. Product Data. Tests. Form. Storage

1-part Flexible Sealant for Concrete and Masonry Facades

Construction. 1-part high performance sealant for flooring. Product Description. Environmental Information. Product Data Sheet Edition _1

1-part elastic joint sealant and multipurpose adhesive

1-part high performance sealant for flooring

1-part polyurethane pourable self levelling floor joint sealant

1-part elastic joint sealant and multipurpose adhesive

TECHNICAL DATA SHEET SIKAFLEX 11FC + WHITE CT

Construction. 1-part elastic joint sealant and multipurpose adhesive. Product Description

1-part elastic joint sealant and multipurpose adhesive

TECHNICAL DATA SHEET SIKABOND AT METAL GREY 300CC

PRODUCT DATA SHEET Sikaflex Tank N

1-part Elastic Sealants for Joints Exposed to Chemicals

1-part polyurethane sealant for building joints

Non-sag, ultra low modulus, neutral cure silicone sealant for pavements

1-part elastic joint sealant and multipurpose adhesive

CHARACTERISTICS / ADVANTAGES

PRODUCT DATA SHEET Sikaflex Tank N

CHARACTERISTICS / ADVANTAGES

1-part elastic sealant for joints exposed to chemicals

TECHNICAL DATA SHEET SIKADUR 31 CF NORMAL 6KG

TECHNICAL DATA SHEET SIKADUR 31 RAPID 1.2KG

Product Data Sheet Edition 25/01/2006. Sikasil WS-305. Product Description. Uses. Characteristics / Advantages

TECHNICAL DATA SHEET SIKABOND-52 WOOD FLOOR 600ML (20/BOX)

Product Data Sheet Sikadur -31 CF Normal Product Description Uses ruction Const Characteristics / Advantages

Sikadur -Combiflex CF Adhesive Type N and Type R are thixotropic two part adhesives based on epoxy resins and fillers.

Building Systems. 1-Part Silicone Weatherseal for Structural Glazing. Product Description. Product Data Sheet Edition_1, 2009 Sikasil WS-305 CN

TECHNICAL DATA SHEET SIKABOND-54 WOOD FLOOR 6KG (3pack=18KG)

Construction. Adhesive for bonding Carbon Fibre & Steel reinforcement. Product Description. Tests

Footfall sound dampening system for wood flooring

TECHNICAL DATA SHEET SIKA ANCHORFIX-1 GREY 300ML (6's)

3-part thixotropic epoxy patching mortar

PRODUCT DATA SHEET Sikadur -32 Normal

Product Data Sheet Product n Description Uses tio tru Characteristics / C Advantages Tests Approval / Standards

OLIVÉ C-22 LOW MODULUS NEUTRAL SILICONE PRODUCT DESCRIPTION:

Easy spreadable, solvent free elastic adhesive for wood flooring

Sikaflex -1a. One-Part Polyurethane, elastomeric sealant/adhesive. Product Description. Product Data

TECHNICAL DATA SHEET SIKA RAPID REPAIR MORTAR 25KG

Construction. Easy Clean, solvent & isocyanate free, elastic adhesive for full surface bonding of wood flooring. Product Description.

Construction. Easy Clean, solvent & isocyanate free, elastic adhesive for full surface bonding of wood flooring. Product Description.

Construction. Solvent free elastic adhesive for wood flooring. Product Description

Construction. One component cementitious mortar fibre reinforced for flexible waterproofing. Product Description. Product Data. Form.

1-part high performance polyurethane sealant for building joints. ISO 11600(Type F Class 25HM/20LM)

Low viscous (easy flowing) elastic adhesive for wood flooring

TECHNICAL DATA SHEET SIKALASTIC-1K

Roofing. Sarnacol Adhesive for Insulation Boards. Product Description. Product Data. Polyurethane-based humidity-hardening one-pack adhesive

Construction. Easy to spread, semi-elastic adhesive for full surface wood floor bonding. Product Description. Product Data. Form.

Construction. 1-part elastic sealant for the internal and external caulking of wooden floors. Product Description. Product Data. Form.

High viscous (thixotropic) elastic adhesive for wood flooring

Construction. Solvent free elastic adhesive for wood flooring. Product Description 1 1/6

PRODUCT DATA SHEET Sikadur 31 CF Normal (formerly Sikadur 731)

Swellable joint sealing profiles

Cementitious Concrete Repair Mortar

2-part water dispersed epoxy coating

Low Viscosity, Solvent Free Elastic Adhesive for Wood Flooring. Solvent free Odourless Recyclable tin pail EMICODE EC 1 PLUS R, very low emission

Construction. High performance joint sealing system. Product Description. System Data Sheet Edition _1. 1 Sikadur Combiflex SG system 1/8

Product Data Sheet Edition 25/01/2006. Sikasil IG-25. Product Description. Uses. Characteristics / Advantages

R4 Fast Setting Cementitious Repair Mortar

Footfall sound dampening system for wood flooring

Protective coating for exposed concrete

Construction. Solvent free elastic adhesive for Wood Flooring. Product Description. Product Data Sheet Edition _1. 1 SikaBond -52 Parquet 1/6

SealArm Tape TPE. Building & Joint Sealants T E C H N I C A L D A T A S H E E T. Uses. Features and Benefits

Fast curing epoxy resins + polyurethane

Non-metallic dry shake floor hardener

R4 Hand Placed / Wet Spray Repair Microconcrete

Product Data Sheet Edition 25/01/2006. Sikasil SG-500. Product Description. Uses. Characteristics / Advantages

R4 Hand Placed / Wet Spray Repair Microconcrete

Construction. Solvent Free Elastic Adhesive for Wood Flooring. Product Description

Construction. Type N and Type R. 2-part epoxy adhesive Part of the Sikadur -Combiflex System. Product Description. Tests

PRODUCT DATA SHEET Sikadur -31 DW

Epoxy resin MIO + polyurethane

Sikaflex -11FC+ Fast Curing One Part Polyurethane Universal Sealant/Adhesive

PRODUCT DATA SHEET Sikalastic -501 Roofseal Plus

DOWSIL 796 Neutral Silicone

PRODUCT DATA SHEET Sikadur -42 HE

According German Standard DIN part 1. Standard range of PVC-P based flexible waterstops for movement (expansion) and construction joint sealing

Two component spray applied roof waterproofing membrane

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

Construction. Type N and Type R. 2-part epoxy adhesive Part of the Sikadur -Combiflex System. Product Description

Construction. Low viscous (easy flowing) elastic adhesive for wood flooring. Product Description. Product Data

SYSTEM DATA SHEET Sikafloor Pronto RB-28

Sikadur -31 DW Rapid (VP)

PRODUCT DATA SHEET Sikalastic Rapid-721

Ultra fast spray applied polyurethane membrane

PVC profile waterstops for joint sealing

Construction. Adhesive for bonding reinforcement. Product Description. Tests. Product Data Sheet Edition 16 December 2014

Spray applied modified polyurea membrane

Construction. 2-part epoxy primer. Product Data

Bonding Primer and Reinforcement Corrosion Protection

2-part, electrostatically conductive epoxy coating

3-component epoxy self-smoothing screed

Construction. Low viscous (easy flowing) elastic adhesive for wood flooring. Product Description. Product Data

Two-component solvent-free polyurethane adhesive used in the construction of SikaRoof MTC Cold Bonding. Twin-pack product

Product Data Sheet Product Description Uses Characteristics / Advantages Tests Approval / Standards Product Data Construction Form

Conforms to the requirements of ETAG Certificate: European Technical Approval No. ETA-05/0265

Roofing. Sika-Trocal SG 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

Transcription:

TECHNICAL DATA SHEET SIKAFLEX FLOOR A 1-part, moisture curing, elastic joint sealant with high mechanical resistance for flooring. Buy SIKAFLEX FLOOR at https://www.spcsupplies.com//products/sikaflex-floor/ SIKA - SPC SUPPLIES Waterproofing Supplies: https://www.spcsupplies.com/shop/waterproofing/ Admixtures and Building Chemical Supplies: https://www.spcsupplies.com/shop/admixtures-and-building-chemicals/ Flooring and wall finishing Supplies: https://www.spcsupplies.com/shop/flooring-and-wall-finishing/ Adhesives, Sealants and Filler Supplies: https://www.spcsupplies.com/shop/adhesives-sealants-and-fillers/ Wood Preservative Supplies: https://www.spcsupplies.com/shop/wood-preservatives/

Product Data Sheet Edition 24/02/2016 Identification no: 020505010040000001 1-part sealant for flooring Construction Product Description / Uses Characteristics / Advantages Approvals / Standards Specific Ratings Technical Data Colours Packaging Storage Conditions / Shelf-Life is a one part, moisture curing, elastic joint sealant with high mechanical resistance for the following indoor and outdoor applications: Connection joints in floors Joints for crack control in industrial floors Floor joints between pre-cast concrete elements (mainly indoor) Movement capability of 12.5% (ISO 9047) Bubble-free curing Good application properties Very good adhesion to most construction materials Solvent free and odourless Conforms to EN15651-4 PW EXT-INT CC 12.5 E Conforms to ISO 11600 F 12.5 E LEED EQc 4.1 SCAQMD, Rule 1168 BAAQMD, Reg. 8, Rule 51 passes passes passes Grey structured 600 ml foil pack, 20 foil packs per box 12 months from date of production if stored in undamaged original sealed containers, in dry conditions and protected from direct sunlight at temperatures between +5 C and +25 C. 1/4

Technical Data Chemical Base i-cure technology polyurethane Density 1.65 kg/l approx. (CQP 1) 006-4, ISO 1183-1) Sag Flow < 2 mm (20 mm profile, 50 C) (CQP 061-4, ISO 7390) Skin Time 60 minutes approx. 2) (CQP 019-1) Tooling Time 45 minutes approx. 2) (CQP 019-2) Curing Rate 3 mm/24 h approx. 2) (CQP 049-2) Movement Capability ±12.5% (ISO 9047) ±25% (ASTM C719) Shore A Hardness 40 after 28 days approx. 2) (CQP 023-1, ISO 868) Tear propagation resistance 7 N/mm approx. 2) (CQP 045-1, ISO 34) Secant tensile modulus 0.8 N/mm 2 approx. at 60% elongation 2), 3) (CQP 020-1, ISO 8339) Elongation at Break 500% approx. 2) (CQP 036-1, ISO 37) Elastic Recovery >85% 2), 3) (ISO 7389) Application Temperature Service Temperature Resistance +5 C to +40 C, min. 3 C above dew point temperature -40 C to +70 C Resistant to water, seawater, diluted alkalis, cement grout and water dispersed detergent. Not resistant to alcohols, organic acids, concentrated alkalis and concentrated acids, chlorinated (hydro-carbons) fuel. 1) Sika Corporate Quality Procedure 2) 23 C / 50% r.h. 3) conditioning: Method B Application Details Joint Design/ Consumption The joint width must be designed to suit the movement capability of the sealant. In general the joint width should be > 10 mm < 30 mm. A width to depth ratio of approx. 1:0.8 must be maintained For concrete flooring applications where saw cuts joints are required, a minimum sealant joint width and depth of 6mm is recommended and is only applicable for non movement joints. Standard joint widths for joints between concrete elements: with a T* of 40 C Joint distance [m] 2 4 6 8 Min. joint width [mm] 10 15 20 30 Thickness of sealant [mm] 10 12 18 25 with a T* of 80 C Joint distance [m] 2 4 Min. joint width [mm] 15 30 Thickness of sealant [mm] 12 25 * T is considered to be the difference between the highest expected temperature in use (or lowest, check which case leads to higher t) and the application temperature. 2/4

All joints must be properly designed and dimensioned in accordance with the relevant standards, before construction. Basis for calculation of the necessary joint width are the technical values of the joint sealant and the adjacent building materials, as well as the exposure of the building, type of construction and its dimensions. Approximate consumption Joint width [mm] 10 15 20 25 30 Joint depth [mm] 10 12 16 20 24 Joint length / 600 ml [m] 6 3.3 1.9 1.2 0.8 Backing: Use closed cell, polyethylene foam backing rods. Flush joint design prevents trip hazards and dirt traps Recessed joint design protects the sealant against mechanical loads Substrate Preparation / Priming generally has strong adhesion without primers/activators to most clean, sound substrates. For optimum adhesion and critical, high performance applications such as multi story building work, high stress bonding joints, extreme weather exposure or water immersion the following procedure shall be followed: Non porous substrates Aluminium, anodised aluminium, stainless steel, galvanised steel, powder coated metals or glazed tiles have to be cleaned and pre-treated with Sika Aktivator-205 by using a clean towel. Before sealing allow a flash-off time >15 min (max.6 hours). Metals like copper, bras, titanium-zinc etc. have to be cleaned and pre-treated with Sika Aktivator-205 by using a clean towel. After a flash-off time >15 minutes, apply Sika Primer-3 N by using a brush and allow a flash-off time >30 minutes (max. 8 hours) before sealing. PVC has to be cleaned and thereafter pre-treated with Sika Primer-215 by using a brush. Before sealing allow a flash-off time > 30 min (max.8 hours). Porous substrates Concrete, aerated concrete and cementitious plasters, mortars, brick, etc. have to be primed with Sika Primer-3 N by using a brush. Before sealing allow a flash-off time >30 minutes (max. 8 hours). For detailed instructions consult the Product Data Sheet for pre-treatments or contact our Technical Service Department. Primers are adhesion promoters. They neither substitute for the correct cleaning of the surface nor improve their strength significantly. Application Method / Tools Cleaning of Tools is supplied ready to use. After suitable substrate preparation, insert backing rod to the required depth and apply primer if necessary. Insert foil pack into sealant gun and extrude Sikaflex Floor into joint making sure that it is in full contact with the sides of the joint and avoid air entrapment. must be tooled firmly against joint sides to ensure good adhesion. Masking tape may be used where exact joint lines or exceptionally neat lines are required. Remove the tape within the skin time. Use a compatible tooling agent (e.g. Sika Tooling Agent N) to smooth the joint surfaces. Do not use solvent containing products! Clean all tools and application equipment with Sika Thinner C immediately after use. Once cured the material can only be removed mechanically. 3/4

Construction Further Documents available Notes on Application / Limitations Value Base Health and Safety Information Legal Notes Safety Data Sheet (SDS) Pre-treatment Chart Sealing & Bonding Method Statement Joint Sealing Method Statement Joint Maintenance, Cleaning and Renovation can be over-painted with most conventional paint systems. The paint must be tested for compatibility by carrying out preliminary trials and the best results are obtained if the sealant is allowed to cure fully first. Please note that nonflexible paint systems may impair the elasticity of the sealant and lead to cracking of the paint film. Colour deviations may occur due to exposure to chemicals, high temperatures, UVradiation. However a change in colour will not adversely influence the technical performance or the durability of the product. Do not use as a glass sealer, on bituminous substrates, natural rubber, EPDM rubber or on building materials which might bleed oils, plasticisers or solvents which could attack the sealant. Do not use to seal swimming pools. Do not expose uncured to alcohol containing products as they may interfere with the curing reaction. All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Safety Data Sheet containing physical, ecological, toxicological and other safety-related data. The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. SIKA LIMITED Head Office Watchmead Welwyn Garden City Hertfordshire AL7 1BQ United Kingdom Phone: +44 1 707 394444 Fax: +44 1 707 329129 www.sika.co.uk 4/4