Examples of Viscosity Measurement With Sine-Wave Vibro Viscometer SV-10 Concerning Typical Lubricants (Viscosities at 40 C and 100 C in Particular)

Similar documents
Tuning Fork Vibro Rheometer

Thermal Conduction and Surface Area

Core Lab: Energy Changes During Melting and Evaporation

Determination of the Molar Mass of a Compound by Freezing Point Depression

MODULE 3 - BEARINGS LECTURE 1- SLIDING CONTACT BEARINGS INTRODUCTION

Figure 1(a) The maximum mass of ice melted (m) for difference mass of liquid X (M) are obtained and recorded in Table 1.

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

39 Acid base titration: Alanine (HA2) (2- aminopropanoic acid) with sodium hydroxide

Lab 12 - Heat Engines and the First Law of Thermodynamics

Heating and Cooling Curves Lab 8 Due Date:

Effect of Heat and Air on Asphalt Materials (Thin-Film Oven Test)

Pre-Lab Exercises Lab 8: Biochemistry

Objective To determine the penetration value of an asphalt cement sample.

Standard Test Method for Effects of Heat and Air on Asphaltic Materials (Thin-Film Oven Test) 1

Versatile Research Heat Exchanger

DENSITY of Solids and Liquids

7. SURFACE TENSION AND DETERMINATION

Experimental Procedure. Lab 402

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

HDPE Flake Wash Test HDPE- S- 02

Paste pipeline transportation for Chambishi Copper Mine

PHYSICAL CHANGE OR CHEMICAL CHANGE?

Air Cooler Industry AC-MS Modular Systems

Experimental techniques

NEW ANALYZER FOR VISCOSITY MEASUREMENT AT REFERENCE TEMPERATURE

6. TEST METHOD FOR TENSILE FATIGUE STRENGTH OF CONTINUOUS FIBER SHEETS (JSCE-E )

Energy, Power, and Transportation Technology 11

Preparation of copper(ii) sulfate from copper(ii) nitrate

LAB 13: HEAT ENGINES AND THE FIRST LAW OF THERMODYNAMICS

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

Instrumental Approach and Improvement of the Low-Temperature Determination of ATF Fluidity Author: Theodore Selby Savant, Inc.

LAB 13: HEAT ENGINES AND THE FIRST LAW OF THERMODYNAMICS

Kinematic Viscosity Viscometer

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Preliminary Studies on In Situ Monitoring of Lactose Crystallization Using Focused Beam Reflectance Measurement

Electromagnetic Casting Technique for Slab Casting

Flow Science Report Validating the Thermal Stress Evolution Model. I. Introduction. II. Experiment Setup

PROBLEM 2: PREDICTING GLASS RIBBON SHAPE IN

Tsunami Countermeasures at Hamaoka Nuclear Power Station -- Design and Construction of Tsunami Protection Wall

New Insights into the Tribological and Kinetic Attributes of Retaining Rings in CMP

Grand Composite Curve Module 04 Lecture 12

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

Vibration isolation pads

AT73.06: Product Design & Development

Test and Analysis of Metallurgical Converter Equipment

Experiment 13: Determination of Molecular Weight by Freezing Point Depression

Episode 608: Latent heat

M-03 HEAT EXCHANGERS

Appendix B. Glossary of Steam Turbine Terms

BME Polymer Lab

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Effect of Vibration on Heat Transfer Enhancement in a Rectangular Channel Heat Exchanger

THE MOLECULAR WEIGHT OF A SOLUTE*

Peerless Pump Company Handbook of Engineering Data

INTERNATIONAL OIML R 69 RECOMMENDATION. Glass capillary viscometers for the measurement of kinematic viscosity - Verification method

Dynamic Design of the Foundation of Reciprocating Machines for Offshore Installations in Persian Gulf

EXPERIMENT 5 Chemistry 110 COMPOSITION OF A MIXTURE

Experimental Study on Seismic Performance of Equipment with Vibration Isolation Devices

will denote mass of suspension before the filtration in an accumulation tank, m F mass of filtrate, m K mass of produced filtration cake, m S

CHAPTER - 1 INTRODUCTION

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium)

ENGINEERING DESIGN GUIDE UNITHERM...

INVITATION FOR QUOTATION. TEQIP-II/2015/GJ1G02/Shopping/M-CE-04

Phase Diagrams Revised: 1/27/16 PHASE DIAGRAMS. Adapted from Bill Ponder, Collin College & MIT OpenCourseWare INTRODUCTION

Standard Test Methods for Softening Point of Resins Derived from Naval Stores by Ring-and-Ball Apparatus 1

Tianjin Plant-Produced Machining Center NHC Series

A Full-Scale Experimental Study on Seismic Behaviour of Vibration Isolated Mechanical/Electrical Equipment

The rollercoaster car is raised a vertical distance of 35 m to point A by a motor in 45 seconds

Lab 12 - Heat Engines and the First Law of Thermodynamics

Experiment B-38 Monitoring Yeast Growth

Item Units Results Remarks Appearance - Red, transparent Visual Viscosity mpa s C Specific Gravity C. Min 6~12

Analysis on Viscous Flow of VAD Silica Glass During Heat Forming

Effect of Temperature on Cold-Blooded Organisms

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK

FOUR POSSIBLE OPTIONS FOR THE USE OF INSULATION PADS FOR MACHINE INSTALLATION

COMMENTARY ON THE TEST METHOD FOR TENSILE FATIGUE OF CONTINUOUS FIBER REINFORCING MATERIALS (JSCE-E )

Moisture Analyzers ISO 9000 CERTIFIED.

Technical Specifications

Standard Test Procedures Manual

Response Analysis of an RC Cooling Tower Under Seismic and Windstorm Effects D. Makovička

IGCSE Co-ordinated Sciences 0654 Unit 19: Energy transfer

Preliminary studies on in situ monitoring of lactose crystallization using focused beam reflectance measurement

Chem 355 Jasperse DISTILLATION

Innovative, Thermally Conductive Silicone Solutions for LED Lighting

INDUSTRIAL THERMOMETERS

Exploring Design, Technology, & Engineering Chapter 21 Energy-Conversion Technology

Elasticity. Shape of the Demand Curve

Salinity in Seawater

Physical Simulation of a CZ-Process of Semiconductor Single Crystal Growth

Rubber Low Temperature Brittleness Tester TRBT-A10

THW-L2 LIQUIDS PASTES INSULATION. Portable Thermal Conductivity Meter for Measurement of Liquids, Pastes, & Insulation.

1/58 Components of solar systems

Canadian Council of Independent Laboratories Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) AASHTO T315-09

When this process occurs in water, the oxygen consumed is dissolved oxygen.

Evaluating an Ultrasonic Flaw Detector-Based Method to Characterize Solubility of Whey Protein Concentrate

Instruction Manual Updated 6/1/2009 Ver. 2.0

doi: /s z

Application of Isolation Technology in High-voltage Electrical Equipments

Measuring discharge. Climatological and hydrological field work

Potentiometric titration

Transcription:

February 2004 Examples of Viscosity Measurement With Sine-Wave Vibro Viscometer SV-10 Concerning Typical Lubricants (Viscosities at 40 C and 100 C in Particular) Marketing Division, A&D Co., Ltd. Introduction The results of viscosity measurement with the sine-wave vibro viscometer SV-10 concerning four types of lubricants provided from a customer as sample will be described hereinafter. Sample and Instrument 1. Sample Viscosities of four typical lubricants, described below, provided by a customer for determining viscosity were measured. 1: Hydraulic oil, standard type 2: Diesel engine oil, standard type 3: Automatic transmission fluid, luxurious type 4: Gasoline engine oil 2. Instrument The sine-wave vibro viscometer SV-10 (made by A&D Co., Ltd.), which measures viscosity by vibrating its sensor plates immersed in a sample at relatively low frequency (approx. 30Hz) of sine-wave, was used as the measuring instrument of viscosity. Since the instrument produces low frequency and very small amplitude (approx. 0.4mmpp), it does not impair the composition of the sample unlike a rotational viscometer. The instrument can measure viscosity of a sample according to the temperature of the entire sample due to the small thermal capacity of the sensor plate, and it is also possible to perform real-time measurement of the correlation between the viscosity and temperature of the sample. The instrument can measure viscosities ranging from 0.3mPa s to 10000mPa s (10Pa s) with no need to change the sensor plates during the measurement, thus continuous measurement of viscosity is possible from low to high viscosities. Method This viscosity measurement, as shown in Fig.1, was performed while observing the behavior displayed in real-time on the screen of a personal computer connected to the viscometer SV-10 via RS232C interface. The procedure of the viscosity measurement was as follows; after completely washing and drying a 200ml glass beaker, an unopened tank of the sample was rolled over several times slowly enough to agitate the content before approx. 150ml of the sample was poured into the beaker, and then viscosity measurements were performed on a hot stirrer. 1. The height of the sensor unit (head) of SV-10 was adjusted to fix the sensor plates in the prescribed position. 2. The hot stirrer was rotated to stir the sample slowly, preventing it from making viewable ruffles on the liquid surface. 3. The viscosity measurement was started at room temperature and the viscosity was measured for approx. five minutes. 4. The heater of the hot stirrer was turned on and measurement was continued while heating the sample until the temperature of the sample reached approx. 110 C. 5. The hot stirrer was turned off when the temperature of the sample reached approx. 110 C, and the sample was left at room temperature to naturally cool to approx. 30 C while the viscosity continued to be measured. In brief, for each sample of the four lubricants, a continual viscosity measurement was performed following the above procedure 1 to 5 while stirring slowly and continually changing the temperature of the sample from approx. 1/6

25 C (room temperature) to 110 C and to approx. 30 C (around room temperature) in order to burden the sample with a temperature load on heating, followed by cooling. At the same time, the relative dial setting position of the hot stirrer s revolving speed was not changed during the measurement. The data about the viscosity and temperature of the sample during the measurement was transmitted in real-time to the computer via RS232C, and sampling was made at intervals of five seconds. Sample Hot Stirrer Fig. 1 View of Viscosity Measurement Fig. 2 Viscosity Measuring Unit Result and Review Table 1 shows the viscosities (readings of SV-10) of the four lubricants measured at 40 C and 100 C on heating and cooling. The sine-wave vibro viscometer SV-10, under its measuring principles, produces a relative indication of the measured viscosity (instrument reading) as a product of the specific gravity and the viscosity. Therefore, an absolute viscosity can be obtained by dividing the viscosity shown in Table 1 by the specific gravity of the sample. Additionally, a kinetic viscosity can be obtained by dividing the absolute viscosity, which is calculated as above, by the density (here, the same as the specific gravity) of the sample. Table 1. Viscosities (readings of SV-10) of the four lubricants measured at 40 C and 100 C on heating and cooling SV-10 Viscosity Measurement Values (mpa s) 1: Hydraulic oil, standard type 40 C 100 C Heating Cooling Average Heating Cooling Average 2: Diesel engine oil, standard type 39.2 38.5 38.9 5.56 5.80 5.68 85.1 83.2 84.2 9.32 9.37 9.35 3: Automatic transmission fluid, luxurious type 21.3 21.3 21.3 5.11 5.34 5.23 4: Gasoline engine oil 49.5 48.8 49.2 8.11 8.17 8.14 For each sample, Figures 4 to 7 show the graphs, which were created with the graph function of the communication software WinCT-Viscosity, equipped as standard with SV-10, of the continual behavior of the viscosity and temperature during the measurement. Figs.4a&b show the graphs of the viscosity and temperature of Hydraulic oil, standard type while being stirred slowly as well as heating from 25 C room temperature to 110 C, followed by cooling naturally to 30 C again (around room temperature). Fig.4a, the graph on the left, shows the elapsed time plotted along the horizontal axis and the viscosity (in red) and the temperature (in blue) plotted along the vertical axes on the left and right respectively. The blue curve on the graph shows the process of change in temperature; the process of heating followed by cooling appears in the shape of a mountain. On the other hand, the viscosity (in red) appears in a U-shaped curve, which is in inverse proportion to the temperature curve. Fig.4b, the graph on the right, shows the temperature plotted along the horizontal axis and the viscosity plotted along the vertical axis in order to define the correlation between the viscosity and temperature. As shown in the graph, a nonlinear inverse correlation between 2/6

the viscosity and temperature can be observed. In addition, since the curves on both heating and cooling processes are almost superposed, it is considered an excellent repeatability of viscosity measurement with the sample and SV-10 s measuring system. In the same way, Figs.5a and 5b show the results of Diesel engine oil, standard type, Figs.6a and 6b show those of Automatic transmission fluid, luxurious type), and Figs. 7a and 7b show those of Gasoline engine oil. 3/6

Fig.4a Viscosity Change (in red) in Relation to Temperature Change (in blue) of Hydraulic oil, standard type (Changes With Time) Fig.4b Correlation Between the Temperature and Viscosity of Hydraulic oil, standard type Fig.5a Viscosity Change (in red) in Relation to Temperature Change (in blue) of Diesel engine oil, standard type (Changes With Time) Fig. 5b Correlation Between the Temperature and Viscosity of Diesel engine oil, standard type 4/6

Fig.6a Viscosity Change (in red) in Relation to Temperature Change (in blue) of Automatic Transmission Fluid, Luxurious Type (Changes With Time) Fig.6b Correlation Between the Temperature and Viscosity of Automatic Transmission Fluid, Luxurious Type Fig.7a Viscosity Change (in red) in Relation to Temperature Change (in blue) of Gasoline Engine Oil (Changes With Time) Fig.7b Correlation Between the Temperature and Viscosity of Gasoline Engine Oil 5/6

Conclusion 1. Viscosities of four typical types of lubricants were measured with the viscometer SV-10. 2. The facts that the correlation between the viscosity and temperature of each sample is in a nonlinear inverse correlation on both the heating and cooling processes and that during the processes viscosity at the same temperature shows almost the same value, which is considered an excellent repeatability, were confirmed. 3. Since excellent measurement repeatability is observed as described in 2 above, the viscosities of each sample at representative temperatures 40 C and 100 C are shown in Table 1 as a summary of the results. It is considered that the significant individual differences between the samples can be distinguished by measuring the viscosity of the four lubricants at the above mentioned two points of temperature using the sine-wave vibro viscometer SV-10, although significant difference tests should be repeated a greater number of times with more samples before making such determination. 6/6