ESTIMATING/TAKE-OFF AND ORDERING GUIDE

Similar documents
1600 WALL SYSTEM 2 ESTIMATING/TAKE-OFF AND ORDERING GUIDE (16 Pages) E.C.# (09/09/13)

PART IDENTIFICATION...

ESTIMATING/TAKE-OFF AND ORDERING GUIDE

SPECIAL NOTES: EXCLUSIONS: THE FOLLOWING ITEMS ARE NOT SUPPLIED - SEE SEPARATE SAMPLES FOR GLASS MAKE UP.

apexfacades.com apexfacades.com. Keystone Pg- 1

TMW 450 TECHNICAL MANUAL

Series Outside glazed curtain wall. Installation instructions

Series Silicone structural glazed. Installation Instructions

Series Silicone structural glazed curtain wall. Installation instructions

Aluminum-Framed Entrances and Storefronts

SWING DOOR SPECIFICATION

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

Flushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide

PINNACLE 600/650 HIGH PERFORMANCE CURTAIN WALL apexfacades.com. apexfacades.com 1.2 Pinnacle Pg- 1. Printed on 12/12/17

SECTION E INDEX CURTAINWALL FRAMING SYSTEMS

INSTALLATION INSTRUCTIONS 2-1/2 x 7-5/16 for 1-5/16 Glass

200 Singleton Drive Waxahachie, Texas T: F:

TMS 114 XT TECHNICAL MANUAL

Installation Instructions

2-1/4" Flush Projected Architectural Thermal Aluminum Windows. Project In TR-2400 (AW-PG80-AP) or Project Out TR-2500 (AW-PG80-AP)

E-Wall System 5800, 5800-I

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

System Curtain Wall Thermally Improved System

TMS 152 / 152T / 152XT TECHNICAL MANUAL

Series x Thermal Triple Set Storefront Framing

SERIES 5600PG PREGLAZABLE CURTAINWALL

SERIES 487 CENTER GLAZED SLIDING DOOR WITH 1-1/2" TRIM

SECTION ALUMINUM ENTRANCES AND STOREFRONTS. A. Section Includes: Aluminum doors and window wall frames.

Architectural Specification Manual

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

TABLE OF CONTENTS: HURRICANE RESISTANCE STOREFRONT SERIES IT600 REVISION D E S C R I P T I O N HURRICANE RESISTANT STOREFRONTS CRL / US ALUMINUM

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

7000 Series Curtain Wall Information Specifications

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL

SECTION B3 SERIES COS451 FRONT GLAZED STACKING SYSTEM

SIGNATURE SERIES UNIT WALL

Specification Section Storefront Systems has been revised. Omit previously issued Storefront section.

FG/FT-451 S T O R E F R O N T. 2 x 4 1/2 THERMAL & NON THERMAL WALL DETAILBOOK TRULITE GLASS & ALUMINUM SOLUTIONS TM

1 3 4 Tie Rod Aluminum Swing Entrance Doors

Project: U.S. Federal Courthouse, Coeur d Alene, ID

RIXSON Heavy Duty Floor Closers

Duracast Pressure Plate Installation Instructions

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

Blast Curtain Wall Installation Analysis

System Thermal Clip Storefront System

PERFORMANCE TEST REPORT. Rendered to: TREMCO INC. SERIES/MODEL: Proglaze ETA - System 3 PRODUCT TYPE: Pre-Engineered Air Barrier Transition Assembly

SECTION C1. SERIES CWW451T THERMALLY BROKEN FRONT GLAZED WINDOW WALL / STOREFRONT SYSTEM 2" X 4 1 /2" for 1" GLAZING ARCHITECTURAL DETAILS

YCW 250 I-Beam Curtain Wall System Installation Manual

SECTION ALUMINUM WINDOWS

Series x Thermal Triple Set Storefront Framing

2018 Special-Lite ALUMINUM FRAMING

Architectural Subframe & Casement Windows

SPECIFICATION For the Supply and Installation of BRITAL SG-2-56-HFF. Two Sided Structurally Glazed Curtain Walling. (Horizontal Structural joints)

YOW 250 T Window System

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

T SERIES WINDOW SPECIFICATIONS

Project: U.S. Federal Courthouse, Coeur d Alene, ID

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

C.R. Laurence Co., Inc. Los Angeles, California

Project: North Charleston City Hall, North Charleston, SC

SERIES 4250/4250T CURTAIN WALL

BID # College Center EXTERIOR DOOR REPLACEMENT SECTION "C" TECHNICAL SPECIFICATIONS OWNER

Project No: Pakenham Branch Library, Pakenham, Ontario Section January, 2017 Page 1 of 7

Ballard Avenue Retail/Office Building For Lease

2000 Skylight. For specific product applications, Consult your Kawneer representative. JANUARY, 2017 EC FEATURES ADMF020EN

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

4-5/8" Offset Projected Architectural Thermal Aluminum Windows. Project In TR-740 (AW-PG80-AP) or Project Out TR-750 (AW-PG80-AP)

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

SECTION STAINLESS STEEL WALL PANELS

WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS

HYBRID Curtain Wall HYBRID. Product Manual Curtain Wall 2008

Wall Assembly - ACM Metal Panel at Steel Stud Framing SCALE: 3" = 1'-0"

Curtain Wall Systems. The Fusion Of Strength And Efficiency. Finally, a curtain wall framing system that equals the thermal performance of glass.

SECTION ALL ULTREX DOUBLE HUNG WINDOW

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

SPECIFICATION For the Supply and Installation of BRITAL UN Four Sided Unitized Structurally Glazed Curtain Walling

SECTION ALUMINUM STORM WINDOWS

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012

SERIES BAL-350 ALUMINUM OUTSWING ENTRANCE DOORS

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

STOREFRONT, CURTAINWALL & ENTRANCES

Building Your Visions

Patent No. 9,045,900 Technical Glass Products Architectural Specification Manual

T series Storefront Framing Flush Glazed Thermally Broken Product Details

Unitised Curtain Wall Beaded

FLUSHLINE ENTRANCES. Features

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PRODUCT SPECIFICATION THE 9500 SERIES FAMILY - SERIES 9502 / 9503 THERMALLY BROKEN ALUMINUM OUTSWING BALCONY DOOR

Guide Specification for Pre-Engineered Skylight System. A. Engineering, design and drafting of the entire skylight system.

Aluminum Storefront Systems SERIES 200, 300 and 500 DOORS GUIDE SPECIFICATIONS

Custom fabrication in two weeks or less, guaranteed.

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

SERIES ET350 STRIP WINDOW SYSTEM

General Window Installation Instructions

DETENTION / SECURITY WINDOWS SECTION 08660

Transcription:

MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL 1 ESTIMATING/TAKE-OFF AND ORDERING GUIDE

2 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 INDEX PAGE PART IDENTIFICATION ------------------------------------------------------------ 3, 4, 5 MATERIAL TAKE-OFF GUIDE --------------------------------------------------- 6 PERIMETER DETAILS -------------------------------------------------------------- 7, 8 ANCHOR CHARTS ------------------------------------------------------------------ 9 INTERMEDIATES -------------------------------------------------------------------- 10 90 INSIDE CORNER ---------------------------------------------------------------- 11 90 OUTSIDE CORNERS -----------------------------------------------------------12, 13 ENTRANCE DETAILS --------------------------------------------------------------- 14, 15 GLASSVENT WINDOWS FOR CURTAIN WALL----------------------------------------------------------------------- 16 WINDOW APPLICATION -----------------------------------------------------------17 MID ANCHOR DETAIL -------------------------------------------------------------- 18 INTERMEDIATES W/ FIBERGLASS PRESSURE PLATE------------------------------------------------------------------- 19 Consult the KawneerDirect website for the latest updates to the estimating/ take-off and ordering guides before beginning work on your project.

MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL PARTS IDENTIFICATION 3 1" FRAMING 1/4" FRAMING Extrusion # Profile Description Extrusion # Profile Description 162003 162004 162001 162002 5-1/4" Lightweight 5-1/4" Heavyweight Lightweight Heavyweight 162091 5-1/4" 162015 162016 162013 162014 5-1/4" Lightweight 5-1/4" Heavyweight Lightweight Heavyweight 162093 5-1/4" 162090 162092 162095 5-1/4" 162097 5-1/4" 162094 162203 162204 5-1/4" 162096 162205 162206 5-1/4"

4 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 PARTS IDENTIFICATION PRESSURE PLATE GLAZING ADAPTERS (1" SYSTEM) Extrusion # 162335 162336 162552 162358 162505 Profile Description Standard dry glazed pressure plate. Pre-punched for pressure plate fasteners. Flush Double Acting Door Adapter pressure plate. For use with 162041 cover. See Entrance Details in this Take-Off Guide. Flush Single Acting Door Adapter pressure plate. For use with 162041 cover. See Entrance Details in this Take-Off Guide. Optional dry glazed pressure plate. For use with 162074 (2-1/2") deep cover. Pre-punched for pressure plate fasteners. 1" System Extrusion # Profile Description 162054 1/8" Infill 162019 1/4" Infill 162055 3/8" Infill 162056 1/2" Infill 162057 5/8" Infill 162506 1/4" System PERIMETERS Extrusion # 162017 162176 163023 163024 Profile Description 1" "F" Perimeter 1/4" "F" Perimeter Jamb Channel 5-1/4" & 6" System Perimeter A Jamb Channel 6-3/4" & 7-1/2" System Perimeter A

MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL PARTS IDENTIFICATION 5 SNAP-ON COVERS OPEN BACK FILLERS Extrusion # Profile Description Extrusion # Profile Description 162006 162073 162074 162239 162041 COVER SLEEVES Part # Profile 162313 3/4" Standard Cover 1-1/4" Optional Cover 2-1/2" Optional Cover 3" Optional Cover Flush Door Adapter Cover Description 3/4" Standard Cover Sleeve 162021 162020 Splice Sleeves 128405 Open Back Filler 5-1/4" & 6" System Open Back Filler 6-3/4" & 7 1/2" System Part # Profile Description 162306 162307 SHEAR BLOCK FASTENERS Horizontal (2 per shear block) Mullion Sleeve 5-1/4" Mullion Sleeve Vertical (2 per shear block) 128394 Typical 162356 162357 162530 1-1/4" Optional Cover Sleeve 2-1/2" Optional Cover Sleeve 3" Optional Cover Sleeve PRE-PUNCHED SHEAR BLOCKS Part # 162377 Intermed. Horiz. 162378 Intermed. Horiz. 162331 Head / Sill 162332 Head / Sill 162384 Head / Sill 162385 Head / Sill Description 5-1/4" & 6" System 6-3/4" & 7-1/2" System 5-1/4" & 6" System Perimeter B C 6-3/4" & 7-1/2" System Perimeter B 5-1/4" & 6" System Perimeter A 6-3/4" & 7-1/2" System Perimeter A C

6 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 MATERIAL TAKE-OFF SIDE BLOCK VERTICAL SHEAR BLOCK JOINT PLUG OPEN BACK FILLER HORIZONTAL INTERIOR WEATHERING GLAZING COVER THERMAL SEPARATOR EXTERIOR WEATHERING DESCRIPTION PART NUMBER GLAZING PRESSURE PLATE TAKE-OFF GUIDE Vertical (24'-0" S/L) Make Proper Selection Stock Lengths Required Horizontal (24'-0" S/L) Make Proper Selection Stock Lengths Required Open Back Filler (24'-0" S/L) Cover (24'-0" S/L) Glazing Pressure Plate (24'-0" S/L) Make Proper Selection Make Proper Selection 162335 Stock Lengths Required Stock Lengths Required Stock Lengths Required Thermal Separator Interior / Exterior Weathering Pressure Plate Fastener 162310 027850 128406 Vertical/Horizontal Footage 4 x Vertical/Horizontal Footage 1.8 x Thermal Separator Setting Block (1/4" Framing) 027854 2 Per D.L.O. Setting Block (1" Framing) 027853 2 Per D.L.O. Side Block (1/4" Framing) 027856 2 Per D.L.O. Side Block (1" Framing) 027855 2 Per D.L.O. Shear Block See Shear Block Chart 2 Per Horizontal Shear Block to Vertical Fastener 128394 2 Per Shear Block Shear Block to Horizontal Fastener 128405 2 Per Shear Block Joint Plug (1/4" Framing) (Typical) 162322 2 Per Horizontal Joint Plug (1" Framing) (Typical) 162321 2 Per Horizontal Perimeter "A" Joint Plug (1" Framing) (Typical) 162512 2 Per Horizontal Perimeter "A" Joint Plug (1/4" Framing) (Typical) 162514 2 Per Horizontal Perimeter "C" Vertical End Caps 1" 162388 2 Per Vertical Perimeter "C" Vertical End Caps 1/4" 162389 2 Per Vertical Note: For other applications and accessories, reference shop drawings, installation instructions and Kawneer's website at www..

MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL PERIMETER DETAILS 7 A EXTERIOR FRAME PERIMETER Note: Requires Head / Sill Shear Blocks: 162384 6" System 162385 7-1/2" System Head / Sill Joint Plugs: 162512 1" Framing 162514 1/4" Framing Use "F" & "T" Anchors 027857 PERIMETER GASKET SEALANT AND BACK-UP ROD BY OTHERS. 027857 PERIMETER GASKET 162203 162204 SHIM AS REQUIRED BY OTHERS. 162205 162206 SEALANT AND BACK-UP ROD BY OTHERS. B "F" PERIMETER Note: Use a 162017 or 162018 without F or T anchors only if mullion end reactions are less than 350 pounds. Note: Requires Head / Sill Shear Blocks: 162331 6" System 162332 7-1/2" System Use typical joint plugs. 027857 PERIMETER GASKET SHIM AS REQUIRED BY OTHERS. 162094 162095 PER JOB CONDITION SEALANT BY OTHERS. 162017 "F" PERIMETER, 162176 "F" PERIMETER FOR 1/4" SHIM AS REQUIRED BY OTHERS.

8 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 PERIMETER DETAILS C PERIMETER PRESSURE PLATES Note: Requires Head / Sill Shear Blocks: 162331 6" System 162332 7-1/2" System Typical Joint Plugs Use "F" & "T" Anchors 027857 PERIMETER GASKET SEALANT AND BACK-UP ROD BY OTHERS. 162505 PRESSURE PLATE 162094 162095 SHIM AS REQUIRED BY OTHERS. Note: Uses vertical top & bottom end caps 162388 (1") 162389 (1/4") 027857 PERIMETER GASKET SEALANT AND BACK-UP ROD BY OTHERS. 162506 PRESSURE PLATE 162096 162097 SHIM AS REQUIRED BY OTHERS.

MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL ANCHOR CHARTS 9 "F" AND "T" ANCHOR CHARTS MULLION Note: T- anchors must be used if mullion end reactions exceed 350 pounds. If mullion end-reactions are less than 350 pounds, then perimeter anchoring may be used. (See page 4). End Reactions = Module (ft.) x Length (ft.) x Windload (PSF) (Pounds) 2 PART NUMBER 162308 162311 PART NUMBER F - Anchor Chart To be used with 162001, 162002, 162013, 162014 162003, 162004, 162015, 162016 T - Anchor Chart To be used with System 5-1/4" & 6" 6-3/4" & 7-1/2" System 162309 162001, 162002, 162013, 162014 5-1/4" & 6" 162312 FASTENER PREPS 162003, 162004, 162015, 162016 "T" Anchor "F" Anchor 6-3/4" & 7-1/2" "T" ANCHOR ("F" ANCHOR SIMILAR)

10 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 INTERMEDIATES INTERMEDIATES Note: Requires Intermediate Shear Blocks: 162377 6" System 162378 7-1/2" System Typical Joint Plugs 162335 PRESSURE PLATE 162001 162003 162003 162001 162335 PRESSURE PLATE

MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL 90 INSIDE CORNER 11 90 INSIDE CORNERS 1" System Shown, 1/4" System Similar 0.125" BRAKE 130608 FOAM TAPE 128407 027151 162003 162054 0.125" BRAKE 027857 162335 162006 128406

12 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 90 OUTSIDE CORNERS 90 OUTSIDE CORNERS 1" System Shown, 1/4" System Similar 128407 027151 128406 162335 162006 162054 027857 0.125" BRAKE

MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL 90 OUTSIDE CORNERS 13 90 OUTSIDE CORNERS 1" System Shown, 1/4" System Similar 162255 @ 7-1/2" SYSTEM 162405 162258 @ 7-1/2" SYSTEM 162118 @ 6" SYSTEM 162121 162366 128406 415429 162119

14 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 ENTRANCE DETAIL ENTRANCE DETAILS Entrance Adapters - 1" Framing 162041 162552 2-1/2" TRANSOM BAR Single Acting 162336 2-1/2" Surface mounted closer only. Offset pivots or butt hinges. 069177 162552 2-1/2" 162041 162041 DOOR JAMB Single Acting DOOR JAMB Single Acting

MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL ENTRANCE DETAILS 15 ENTRANCE SUB-FRAME - 1" AND 1/4" FRAMING 1" System Shown, 1/4" System Similar TRANSOM BAR Use with butts, O.S. pivots, or center hung hinges. Use with concealed or surface mounted closer. DOOR JAMB NOTES: Mullion & cover extrusion numbers per job requirements. Details may vary according to hanging and closer combinations used. Typical details shown. Use assembly 450520 in lieu of 450087 if doors are hung offset. 450087 162043 2-1/2" 3/4"

16 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 GLASSVENT WINDOWS FOR CURTAIN WALL HEAD 162082 ADAPTER 027850 027860 127145 FOR PROJECT OUT ONLY 162001 162003 162003 162001 027861 SILL 162001 162003 162082 ADAPTER 027861 027850 JAMB

MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL WINDOW APPLICATION 17 WINDOW APPLICATION 1" FRAMING 162054 ADAPTER 027893 027850 128406 1/4" FRAMING 027893 027852 128406

18 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 MID ANCHOR DETAIL STANDARD INTERMEDIATE DEAD LOAD AND WIND LOAD MID-ANCHOR DETAILS For Alternate Detail Condition Consult Factory. VARIES MULLION 027477 SEPARATOR STEEL ANCHORS DEAD LOAD THRU BOLTS AS REQUIRED 027477 SEPARATOR STEEL ANCHORS 216301 SLIP WASHER WIND LOAD THRU BOLTS AS REQUIRED

MAY, 2017 1600 WALL SYSTEM 1 CURTAIN WALL PRESSURE PLATE 19 INTERMEDIATES W/ FIBERGLASS PRESSURE PLATE Note: Requires Intermediate Shear Blocks: 162377 6" System 162378 7-1/2" System Typical Joint Plugs 128249 162562 FIBERGLASS PRESSURE PLATE NOTE: 162562 REQUIRES 128249-1/4 X 1-1/4" HWHTF AB SCREWS FOR PRESSURE PLATE ATTACHMENT 162001 162003 162003 162001 128249 162562 FIBERGLASS PRESSURE PLATE

20 1600 WALL SYSTEM 1 CURTAIN WALL MAY, 2017 KAWNEER COMPANY, INC. TECHNOLOGY PARK/ATLANTA 555 GUTHRIDGE COURT NORCROSS, GEORGIA 30092