Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics

Similar documents
Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution

Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety

Minimizing Sample Carryover Using the Multiwash Function of the Agilent 1290 Infinity II Multisampler

Automated Scouting of Stationary and Mobile Phases Using the Agilent 1290 Infinity II Method Development Solution

Emulation of the Agilent 1100 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

High-Throughput LC/MS Purification of Pharmaceutical Impurities

Method Transfer from an Agilent 1200 Series LC to an Agilent 1260 Infinity II LC

Method Transfer from an Agilent 1260 Infinity LC to an Agilent 1260 Infinity II LC

Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

Developing Purification Strategies for the Agilent 1260 Infinity II Preparative LC/MSD System

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Application Note. Abstract. Authors. Introduction. Environmental

Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

Quantification of Host Cell Protein Impurities Using the Agilent 1290 Infinity II LC Coupled with the 6495B Triple Quadrupole LC/MS System

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

Agilent Automated Card Extraction Dried Blood Spot LC/MS System

The Agilent Metabolomics Dynamic MRM Database and Method

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Pharmaceutical LC/MS Solutions from Agilent Technologies

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Application Note. Abstract. Authors. Environmental

Monitoring of Mammalian Cell Culture Media with HILIC LC/MS

LC/MS/MS Determination of PFOS and PFOA in Water and Soil Matrices

Determination of Table 3 Compounds by LC/MS/MS Chemours Fluoroproducts Analytical Method Revision date: 4/26/2018

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Increased Throughput in the Determination of PPCPs in Water Using Optimized MS Cycle Times in a High Sensitivity UHPLC-Triple Quadrupole System

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit

Fast Method Development Using the Agilent 1290 Infinity Quaternary LC System with Column Selection Valve

High Speed, Ultra-High Sensitivity, and Robustness Needed for the Quantitation of Pharmaceuticals in Blood Plasma. Application Note. Authors.

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

Analysis of Monoclonal Antibody (mab) Using Agilent 1290 Infinity LC System Coupled to Agilent 6530 Accurate-Mass Quadrupole Time-of-Flight (Q-TOF)

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

Analysis of Trace Organic Contaminants in Water by Direct Injection Using Agilent 6490 LC/MS/MS with Pos/Neg Switching

Agilent 6430 Triple Quadrupole LC/MS System

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Protein Separation with ph Gradients Using Composite Buffer Systems Calculated by the Agilent Buffer Advisor Software

Improved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD)

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

Characterize mab Charge Variants by Cation-Exchange Chromatography

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

EPA Method 540: Selected Organic Contaminants Using Agilent Plexa Cartridges and the Agilent 6460 Triple Quadrupole LC/MS

Cell Culture Optimization Using an Agilent Bio-Monolith Protein A Column and LC/MS

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

The Agilent StreamSelect LC/MS Solution: Increasing the Throughput of a Triple Quadrupole Mass Spectrometer

Analysis of per/polyfluoroalkyl substances (PFASs) in drinking water using the Agilent Ultivo triple quadrupole LC/MS

Peptide Mapping: A Quality by Design (QbD) Approach

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Automated Online SPE for LC/MS/MS Analysis of Trace Organic Contaminants in Water Using the Agilent 1290 Infinity Flexible Cube Module

Technical Note CYP Inhibition Assays: Versatility in the ADDA High Speed Dual Arm Autosampling System

Reproducible LC/MS Peptide Separation Using Agilent AdvanceBio Peptide Plus Columns

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

ITSP Extraction of Cortisol from Plasma

Determination of Asarinin in Xixin (Asari Radix Et Rhizoma)

Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Separation of Native Monoclonal Antibodies and Identification of Charge Variants:

Automated alternating column regeneration on the Agilent 1290 Infinity LC

for water and beverage analysis

Comparing gradient transfer of isocratic hold and delay volume addition using the Agilent 1290 Infinity LC with ISET

ANALYSIS OF MYCOTOXINS IN FOOD MATRICES

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

Application Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore, India

Agilent 1290 Infinity Binary LC System with ISET - Emulation of the Waters Alliance 2695 LC system analyzing b-blockers

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

Agilent Triple Quadrupole LC/MS Quantitation of Pesticides. Workflow Guide

A Comprehensive Approach for Monoclonal Antibody N-linked Glycan Analysis from Sample Preparation to Data Analysis

Profiling Glycosylation of Monoclonal Antibodies at Three Levels Using the Agilent 6545XT AdvanceBio LC/Q TOF

Application Note. Authors. Abstract. Introduction. Pharmaceutical

Automated QbD-Based Method Development and Validation of Oxidative Degraded Atorvastatin

Agilent 1260 Infinity II Prime LC ACHIEVE CONVENIENCE EVERY DAY IN EVERY WAY

Agilent 6400 Series Triple Quadrupole LC/MS. Breakthrough sensitivity now routine for your lab

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

Analysis of Monoclonal Antibody N-glycans by Fluorescence Detection and Robust Mass Selective Detection Using the Agilent LC/MSD XT

A Comprehensive Workflow to Optimize and Execute Protein Aggregate Studies

Agilent 1290 Infinity II LC SET NEW BENCHMARKS IN EFFICIENCY WITH THE NEXT GENERATION OF UHPLC

Introduction. Benefits of the SWATH Acquisition Workflow for Metabolomics Applications

Identifying Monoclonal Antibody Mutation Sites Using the Agilent 1290 Infinity II 2D-LC Solution with Q-TOF LC/MS

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Agilent 1290 Infinity II 2D-LC Solution Biopharmaceutical Polymer Analysis. WCBP Jan 2017 Washington, DC

Clearly Better LC/MS Solutions

Agilent 6000 Series LC/MS Solutions. Confidence in Quantitative and Qualitative Analysis

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS

A Sub-picogram Quantification Method for Desmopressin in Plasma using the AB SCIEX Triple Quad 6500 System

Performance characteristics of the 1260 Infinity Quaternary LC system

Authors. Introduction. Experimental. Environmental Analysis

Agilent 1290 Infinity Binary LC System with ISET Emulation of a Waters Alliance 2695 LC Applying Concave, Convex, and Linear Gradients

Determination of Pesticides in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes. Application Note. Author. Abstract.

Transcription:

Application Note Small Molecule Pharmaceuticals Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics Avoiding Matrix Effects Increasing Detection Sensitivity Authors Jonas Dinser Daiichi-Sankyo Europe GmbH Munich, Germany Sonja Krieger Agilent Technologies, Inc. Abstract This Application Note demonstrates the use of the Agilent InfinityLab 2D-LC Solution coupled with the Agilent 6495 Triple Quadrupole LC/MS for the analysis of drugs and their metabolites in pharmacokinetic studies. 2D LC can eliminate coelution, thereby reducing signal suppression and the risks of cross talk, which can occur in one-dimensional analysis of these complex samples. The second dimension of a 2D-LC/MS/MS analytical method can be used to enhance the signal intensity of mass spectrometric detection by introducing the analytes to the MS source in a more suitable eluent.

Introduction In the past decade, LC/MS/MS has become a well established technology for the analysis of drugs and their metabolites in pharmacokinetic studies. In addition to the clear benefits of this technology, such as high selectivity and analytical sensitivity, peak assignment, or molecular weight information, there are some well-known challenges, for example when analyzing biological samples with complex matrices, such as plasma or cell-culture media. Some of the challenges are, cross-talk due to coelution of isobars or in-source fragmenting metabolites as well as signal suppression due to coeluting matrix components. Signal suppression might be especially problematic in the quantification of analytes with very low concentrations, and can result in insufficient quantitation limits. This Application Note details two examples of how the Agilent InfinityLab 2D-LC Solution coupled with the Agilent 6495 Triple Quadrupole LC/MS can be used in a bio-analytical research environment to overcome the previously mentioned challenges: How two-dimensional separation can eliminate coelution and the risks of cross-talk or signal suppression when dealing with complex analyte mixtures. How a second dimension can be used to enhance the signal intensity of mass spectrometric detection by changing the eluent conditions, thereby introducing the analytes in a more suitable eluent to the MS source, improving quantitation limits significantly. Experimental Equipment The Agilent 129 Infinity II 2D-LC System comprised the following modules: Two Agilent 129 Infinity II High Speed Pumps (G712A) Agilent 129 Infinity II Multisampler (G7167B) with cooler (option #1) Agilent 129 Infinity II Multicolumn Thermostat (G7116B) Agilent 129 Infinity Valve Drive (G117A) with 2-position/4-port-duo valve (2D-LC valve 13 bar: part number 567-4244) Two Agilent 129 Infinity Valve Drives (G117A) with Multiple heart-cutting valves (G4242-64) equipped with 4 µl loops Mass spectrometric (MS) detection was performed using an Agilent 6495 Triple Quadrupole LC/MS equipped with an Agilent Jet Stream ESI source (G1958-65538). Software Agilent OpenLAB CDS ChemStation Edition Rev. C.1.7 SR2 [263] with 2D-LC Software version A.1.3 [25]. Agilent MassHunter Workstation Software LC/MS Data Acquisition, Version B.8., Build 8..823.5 SP1 Agilent MassHunter Workstation Software Quantitative Analysis, Version B.7.1, Build 7.1.524. Chemicals LC/MS grade acetonitrile and methanol were purchased from TH Geyer (Renningen, Germany). Formic acid and ammonium acetate for LC/MS analysis were obtained from Sigma-Aldrich (Steinheim, Germany). Fresh ultrapure water was obtained from an ELGA Pureflex 2 water purification system equipped with a -µm membrane point-of-use cartridge (Veolia Water Technologies Deutschland GmbH, Celle, Germany). Samples and Methods 2D-LC as a Tool to Avoid Signal Suppression and Cross-Talk An in vitro cell suspension-based assay was performed to identify the key enzymes responsible for metabolism of a drug candidate. The drug candidate (a small molecule) and multiple enzyme-specific probe-substrates with corresponding enzyme inhibitors were incubated in a cell suspension. After a defined time period, the samples were collected, and the formation of metabolites was analyzed. To avoid signal suppression or cross-talk, the high abundant substrates and inhibitors were chromatographically separated. The injected solution contained a mixture of the cell supernatant and a solution of stable-isotope-labeled internal standard. See Table 1 for method parameters. 2D-LC to Increase MS Detection Sensitivity by Switching An in vitro cell culture-based assay was performed to evaluate the concentration of parent compound (drug candidate) and its three major metabolites in culture medium and cells. After a predefined incubation time, samples were collected and, before injection, a non stable isotope labeled internal standard was added. See Table 2 for method parameters. 2

Table 1. Method parameters for 2D-LC to avoid signal suppression. One-dimensional analysis and first dimension of 2D-LC analysis Column C18 column, 2.1 15 mm, sub-2 µm Gradient Temperature 4 C Detection Injection A) Water +.1 % formic acid B) Methanol minutes 15 %B 2 minutes 3 %B 2 minutes 7 %B 23 minutes 95 %B 27 minutes 95 %B 27.5 minutes 15 %B ml/min 1 D Analysis: Agilent 6495 Triple Quadrupole LC/MS 2D-LC Analysis: no detection after 1 D separation Injection volume: 2 µl Sample temperature: 1 C Needle wash: 3 seconds in water/methanol (5/5, v/v) Second dimension Column PFP column, 2.1 5 mm, sub-2 µm Gradient Temperature 4 C Detection 2D-LC mode A) Water + % formic acid B) Methanol + % formic acid. minutes 4 %B.7 minutes 9 %B 2 D gradient stop time:.9 minutes 2 D cycle time: 1.35 minutes ml/min Agilent 6495 Triple Quadrupole LC/MS 2D-LC Heart-cutting Time-based multiple heart-cutting was performed with the heart-cuts (sampling table) set according to the first-dimension retention times. Agilent 6495 Triple Quadrupole LC/MS parameters Polarity: Positive and negative Scan type: Scheduled MRM Drying gas temperature: 14 C Drying gas flow: 15 L/min Nebulizer pressure: 4 psig Sheath gas temperature: 385 C Sheath gas flow: 12 L/min Source voltages and ifunnel RF were optimized individually for each compound using Agilent MassHunter Source Optimizer. Table 2. Method parameters for 2D-LC for increased MS detection sensitivity. One-dimensional analysis Column Hybrid silica C18 column, 2.1 1 mm, sub-2 µm Gradient Temperature 4 C Detection Injection A).1 % Formic acid in water B).1 % Formic acid in acetonitrile. minutes 5 %B.5 minutes 5 %B 4.5 minutes 4 %B 6.5 minutes 9 %B Stop time: 8. minutes Post-time: 1.5 minutes.5 ml/min Agilent 6495 Triple Quadrupole LC/MS Injection volume: 5 µl Sample temperature: 1 C Needle wash: 1 seconds in water/methanol (5/5, v/v) First dimension of 2D-LC analysis Column Hybrid silica C18 column, 2.1 5 mm, sub-2 µm Gradient Temperature 4 C Detection Injection A).1 % Formic acid in water B).1 % Formic acid in acetonitrile. min 15 %B 1.5 min 4 %B 2.1 min 9 %B 2.5 min 9 %B 2.53 min 15 %B.9 ml/min No detection after 1 D separation Injection volume: 1 µl Sample temperature: 1 C Needle wash: 1 seconds in water/methanol (5/5, v/v) Second dimension Column Non-endcapped silica C18 column, 2.1 5 mm, sub-2 µm Gradient Temperature 4 C Detection 2D-LC mode MS Parameters A) 5 mm ammonium acetate and 5 % methanol in water B) Methanol. minutes 4 %B.5 minutes 95 %B 2 D gradient stop time: minutes 2 D cycle time: 1. minute ml/min Agilent 6495 Triple Quadrupole LC/MS 2D-LC Heart-cutting Time-based multiple heart-cutting was performed with the heart-cuts (sampling table) set according to the first-dimension retention times. The smart peak parking functionality was used. Agilent 6495 Triple Quadrupole LC/MS Polarity: positive Scan type: MRM Drying gas temperature: 2 C Drying gas flow: 14 L/min Nebulizer pressure: 2 psig Sheath gas temperature: 4 C Sheath gas flow: 11 L/min Capillary voltage: 3,5 V Nozzle voltage: V High-pressure RF: 9 V Low-pressure RF: 6 V 3

Results and Discussion 2D-LC as a Tool to Avoid Signal Suppression and Cross-Talk Cell supernatants from in vitro cell suspension-based assays containing a range of metabolites in the presence of enzyme substrates and inhibitors present complex mixtures. Figure 1 shows the LC/MS/MS analysis of a cell supernatant. The highlighted metabolite coelutes with higher concentrated substrates and inhibitors. In this LC/MS/MS analysis, signal suppression of metabolite due to coelution with higher abundant substrates and inhibitors could occur. For structurally related compounds, cross-talk might also be observed. To avoid signal suppression and cross talk, a chromatographic method that allows resolution of metabolites from substrates and inhibitors is required for the analysis of the cell supernatant. Counts 1 5 2.5 2.4 2.3 2.2 2.1 2. 1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1..9.8.7.5.4.1 12.178 56,717 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 21 22 23 24 25 Figure 1. LC/MS/MS analysis of a cell supernatant. 4

To enable the separation of the metabolite from coeluting substrates and inhibitors, multiple heart-cutting (MHC) 2D-LC was used. Metabolite was heart-cut in time-based mode and transferred to a second-dimension ( 2 D) separation with different selectivity. In the 2 D, metabolite was well resolved from the higher-abundant substrates and inhibitors, as shown in Figure 2. The separation of metabolite from higher abundant substrates and inhibitors can avoid signal suppression and cross-talk. The reduction of signal suppression by further separation of the target compound from the sample matrix is also shown in a previous Application Note 1. Time-based MHC 2D-LC was used to transfer 16 target metabolites from the 1 D to the 2 D. This provided further separation from substrates and inhibitors, resulting in an analysis with a total run time of 35 minutes. For one-dimensional separation of the 16 target metabolites from substrates and inhibitors, six different methods with a run time of 25 minutes each were developed (data not shown). In this context, the application of MHC 2D LC enabled significant time and sample savings. Counts 1 5 2. 1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1..9.8.7.5.4.1 1..9.8.7.5.4.1 1 D Figure 2. 2D-LC/MS/MS analysis of a cell supernatant. 12.178 56,717 1 1.8 11. 11.2 11.4 11.6 11.8 12. 12.2 12.4 12.6 12.8 13. 13.2 13.4 13.6 1 5 2. 2 D 1.9 1.8 1.7 1.6 19.551 1.5 589,678 1.4 1.3 1.2 Counts 16.8 17.2 17.6 18. 18.4 18.8 19.2 19.6 2. 2.4 2.8 21.2 21.6 22. 22.4 22.8 5

2D-LC to Increase MS Detection Sensitivity by Switching In an in vitro cell culture-based assay, one parent compound and one metabolite had to be quantified based on external calibration using an internal standard. For two further metabolites, relative quantification had to be performed because analytical standards were not available. Figure 3 shows the analysis using an existing one dimensional LC/MS/MS method. During method optimization, different column and solvent combinations were examined. Figure 4 displays two LC/MS/MS chromatograms obtained during method optimization. In Figure 4A, conditions similar to the existing LC/MS/MS method shown in Figure 3 were used. Under these conditions, all three metabolites ( M3) were separated from each other, from the parent compound, and from the internal standard, but MS detection sensitivity was compromised due to the solvent used. Using ammonium acetate and methanol in the mobile phase, MS detection sensitivity was greatly improved, but separation of metabolites M3, the parent compound, and internal standard was compromised, as shown in Figure 4B. The coelution of metabolites and M3 is especially critical because all three metabolites show the same mass transition, and need to be separated chromatographically. 1 2 1. M3 5.198 19,925.9.8.7 61,533 counts 2.854 61,533 Counts.5.4.1 M2 4.277 14,37 1. 1.4 1.8 2.2 2.6 3. 3.4 3.8 4.2 4.6 5. 5.4 5.8 6.2 6.6 7. 7.4 7.8 Figure 3. LC/MS/MS analysis of one parent compound (brown trace), its three metabolites (-M3, blue trace), and one internal standard (green trace) in a sample from an in vitro cell culture-based assay. 6

1 2 1. A 1,275 counts M2 1,275.99.9 Response (%).8.7.5.4 29 counts 29.779 M3 741 42 741 counts Parameter Value Column Hybrid silica C18 column, 2.1 5 mm, sub 2 µm A).1 % Formic acid in water B).1 % Formic acid in acetonitrile.5 ml/min.1 -.1.1.4.5.7.8.9 1. 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2. 2.1 1 2 B 4,259 counts 1..9.8 M2 4,259 1.413 Response (%).7.5.4 31,166 counts +M3 31,166 1.36 Parameter Value Column Non-endcapped silica C18 column, 2.1 5 mm, sub 2 µm A) 5 mm ammonium acetate and 5 % methanol in water B) Methanol.5 ml/min.1 -.1.1.4.5.7.8.9 1. 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2. 2.1 Figure 4. Chromatograms obtained during LC/MS/MS method development. 7

To take advantage of both the separation achieved using formic acid in water and acetonitrile in the mobile phase, as well as the MS detection sensitivity achieved using ammonium acetate and methanol in the mobile phase, the two separations were combined in a 2D-LC setup using multiple heart-cutting. In the 1 D, the flow rate was increased to.9 ml/min to increase analysis speed. Figure 5 shows the final 1 D separation. The five target peaks were transferred to the 2 D using time-based heart-cutting. In the 2 D, a fast gradient was performed with a 2 D cycle time of 1. minute to trap the compounds on the 2 D column and elute them in the 2 D solvent to the MS for increased detection sensitivity. Figure 6 shows the 2 D chromatogram obtained after 2D-LC/MS/MS analysis of a sample from an in vitro cell culture-based assay. Compared to the original 1D LC/MS/MS method with a signal intensity of 61,533 counts for metabolite (Figure 3), the 2D-LC/MS/MS method, with a signal intensity of 191,646 counts for metabolite (Figure 6), enabled an increase in the MS detection sensitivity by a factor of 15, considering the reduction in injection volume from 5 to 1 µl. The total run time of the analysis was reduced from 9.5 to 6.5 minutes for the 2D-LC/MS/MS analysis. Response (%) 1 2 1..9.8.7.5.4.1 -.1 Parameter 996.49 M2 4,51.946 2,145 1.289.1.5.7.9 1.3 1.5 1.7 1.9 2.1 2.3 Value M3 Column Hybrid silica C18 column, 2.1 5 mm, sub-2 µm A).1 % Formic acid in water B).1 % Formic acid in acetonitrile.9 ml/min Figure 5. 1 D chromatogram obtained during 2D-LC/MS/MS method development. 1 2 1..9.8.7 M3 125,452 2.27 191,646 counts 191,646 6.259 Counts (%).5.4 M2 33,11 5.36.1 -.1 1. 1.4 1.8 2.2 2.6 3. 3.4 3.8 4.2 4.6 5. 5.4 5.8 6.2 Figure 6. 2D-LC/MS/MS analysis of one parent compound (brown trace), its three metabolites ( M3, blue trace), and one internal standard (green trace) in a sample from an in vitro cell culture-based assay. 8

Conclusion The application of 2D-LC/MS/MS for the analysis of drugs and their metabolites in pharmacokinetic research studies introduces a second-dimension separation, thereby offering the possibility to eliminate coelution and the risk of cross-talk for these complex samples. This was demonstrated for the analysis of cell supernatants from an in vitro cell suspension-based assay. The superior separation achieved using 2D-LC allowed the analysis of 16 target metabolites within a total run time of 35 minutes, which offered significant time and sample savings compared to the use of six different methods necessary for 1D-LC/MS/MS analysis of the target metabolites. The second dimension of a 2D-LC/MS/MS method was successfully used to enhance the signal intensity of MS detection. In such a setup, conditions enabling separation of the target analytes were used in the first dimension, and conditions beneficial for superior MS detection sensitivity were chosen in the second dimension. The introduction of the analytes in a more suitable eluent to the MS source significantly improved quantitation limits. Reference 1. Vanhoenacker, G.; et al. Two Dimensional LC/MS/MS to Reduce Ion Suppression in the Determination of Cannabinoids in Blood Plasma. For Forensic Use. Agilent Technologies Application Note, publication number 5991 7859EN, 217. 9

www.agilent.com/chem For Research Use Only. Not for use in diagnostic procedures. This information is subject to change without notice. Agilent Technologies, Inc. 218 Printed in the USA, May 1, 218 5991-8839EN