Annual sales - $16 Billion

Similar documents
Kawasaki Gas Turbines-Americas Gas Turbines Power Generation Technology & Applications

A TECHNOLOGY FOR TODAY. Atlanta 2010

Hitachi H-25 & H-80 Gas Turbine. Bucharest, Apr.23, 2013

Union College Combined Cooling, Heat and Power Project

Copyright 1984 by ASME COGENERATION - INTERACTIONS OF GAS TURBINE, BOILER AND STEAM TURBINE

The H-25/H-15 Gas Turbine A Product of Hitachi Quality

Cogeneration a.k.a. Combined Heat & Power (CHP) Overview

Optimization of a Cogeneration System in the Automotive Industry

Combined Heat and Power

The H-25/H-15 Gas Turbine A Product of Hitachi Quality

Heat Recovery. Integrated CHP Systems Corp.

Exhaust Heat Recovery Systems

UC Davis - Facilities O&M Cogeneration Plant Bid Package October, 2007

Presented by: Mike Buter Operations Manager

Cogeneration. Thermal Chillers. and. .. ASHRAE National Capital Chapter. Arlington, VA 10/10/2012

NOx CONTROL FOR IGCC FACILITIES STEAM vs. NITROGEN

Gas turbines have been used for electricity generation. Gas turbines are ideal for this application as they can be started and stopped quickly.

Dr. L. Axelsson, Chief Engineer, Development

Installing a New 6 MW CHP System In An Existing District Energy Plant. IDEA 2013 Campus Energy Conference

Gavin Dillingham. USGBC Energy Summit

Challenges in Industrial Waste Heat Recovery. Texas Technology 2006 Showcase Tony Dafft December 6 & 7, 2006

Turbine Inlet Cooling. A Valuable Tool to INCREASE Electric Energy Production

Understand boiler performance characteristics. Use these suggestions when buying, designing or optimizing steam generators

Increasing Energy Efficiency in Breweries with Gas Turbine Cogeneration

8Combined Cooling, Heating and Power Technologies (CHP): An Overview

ALDRON. CHP SOLUTIONS Environmental, Economic & Resiliency Implications NFMT 2015

Capstone Turbine. E-Finity Distributed Generation. The Power to be Independent. Authorized Capstone Distributor

Natural Gas and Gas Turbines: Clean, Efficient and Flexible Energy. Mike Welch, Industry Marketing Manager O&G Siemens Industrial Turbomachinery Ltd.

5.2 MW Solar Mobile Power Unit

Thermal Distribution in District Energy and Cogeneration Systems

Industrial Power. SGT-800 Gas Turbine. Power Generation: (ISO) 47.5 MW(e) / 50.5 MW(e) / energy

WEBINAR #5: Best Practices for Wet Compression. Call In Number: or Access Code: #

Gas Power Systems Energy Efficient CHP Solutions for Commercial and Large-scale Residential Buildings

Air Cooler Industry AC-MS Modular Systems

Combined Heat & Power (CHP) in New Jersey

Equipment Design. Detailed Plant Conceptual Design. Version 9.0

Monitoring Plan for the. Cornell Combined Heat and Power Project (CCHPP) October 2008

Texas Hospital. Central Plant Redesign. Central Utility Plant SECOND PLACE HEALTH CARE FACILITIES, EXISTING 2013 ASHRAE TECHNOLOGY AWARD CASE STUDIES

Bayport Energy Center Thermally Balanced Combined Heat & Power

Packaged AHR (Advanced Heat Recovery) Systems for Engines, Gas Turbines, & Industrial Waste Heat. Tom Pierson

Benefits. Reduced transportation time and cost. Limited on-site inventory. Minimal installation time. Efficient commissioning

Cogen Plant Construction Collaboration in Far East Russian Towns & Villages along with Far East Gas Pipeline by Sojitz/Kawasaki/FEC Russia

Equipment Design. Detailed Plant Conceptual Design. Version 7.0

Gainesville Regional Utilities: Reciprocating Engine CHP

The 34 th Congress of Euroheat & Power

Combined Heat and Power (CHP): Applications of Distributed Power

Gas Turbine Inlet Air Cooling System

Case Study 3. Claudia Meer Managing Director, Energy and Structured Finance Clark Construction Company

Lecture (5) on. Thermal Power Plant Unit Selection. By Dr. Emad M. Saad. Mechanical Engineering Dept. Faculty of Engineering.

How Combined Heat and Power Saves Money, Reduces Emissions and Improves Energy Security. CHP Overview. Anne Hampson ICF International

Gas vs. Diesel Generator Sets Performance Cost & Application Differences

Enhancing a Business Case for Cogeneration Systems

Arrow Linen: CHP Washes Away Energy Costs of Commercial Laundry

Integrating Standby Power and Steam Turbine Chillers for Better Resiliency at UNC Chapel Hill

Microturbine Energy Solutions in the CHP Industry

Course 0101 Combined Cycle Power Plant Fundamentals

Small Turbine Energy. April 9, 2008

Draft Results Capital Cost and Performance of New Entrant Peaking Unit

CEE NATIONAL MARKET TRANSFORMATION COMBINED HEAT & POWER. Gearoid Foley, Sr. Advisor DOE s Mid-Atlantic CHP TAP April 1, 2014

Turbine Inlet Cooling: An Energy Solution That s Good for the Environment, Rate Payers and Plant Owners

ADVANCED ABSORPTION CHILLER CONVERTS TURBINE EXHAUST TO AIR CONDITIONING

Chapter 4.3: Cogeneration, Turbines (Gas, Steam)

Pre-owned 240 MW Combined Cycle Gas Turbine Power Plant

SOME ENERGY-EFFICIENT TECHNOLOGIES IN JAPAN

November 4, 2010, Rev 1

Exploring a University Based Microgrid

Case Studies in Energy Efficiency and Water Conservation Projects

2. Chilled Water Storage: A 4.4-million gallon chilled water storage tank improves Cornell s ability to meet peak cooling needs.

A. Cornell s district energy systems include the following components:

Alex Alexandrovich, P.E.

CAES2 2 nd Generation Compressed Air Energy Storage Technology Presented at SmartEnergy Canada Toronto, February 15, 2011

Combined Heat and Power

PureComfort Cooling, Heating & Power Solutions

Day 1 Training Session #2 Cogeneration & Power Plant Basics

U.S. Environmental Protection Agency Combined Heat and Power Partnership

Pratt & Whitney. Power Systems MOBILEPAC. Gas Turbine Package. It s in our power.

Development and performance analysis of a hybrid solar gas turbine. Lars-Uno Axelsson and Darsini Kathirgamanathan, OPRA Turbines, the Netherlands

SGT-8000H gas turbine series proven in commercial operations

Technology Characterization: Gas Turbines

Waste Heat Recovery for Pipeline Compressor Stations 2009 Gas/Electric Partnership Houston, TX. Presented By Donna Sterrick

AIR PERMITTING CASE STUDY: HARVARD S CHP EXPANSION

2016 BioCleantech Forum TURBODEN ORC TECHNOLOGY: STATE-OF-THE-ART. Ilaria Peretti. Manager, Sales and Business Development North America

Large Frame Gas Turbines, The Leading Technology of Power Generation Industries

VOCGEN CHP Level One Project Feasibility Financial Summary

IDEA Conference Seattle WA

Integration and Onsite System Aspects of Industrial Post-Combustion CCS

MONITORING AND DATA COLLECTION FOR DISTRIBUTED GENERATION/ COMBINED HEAT AND POWER (DG/CHP) SYSTEMS AT ALLIED FROZEN FOODS BROCKPORT, NEW YORK.

District Energy Combined Heat and Power as a Resource

MicroGrids and CHP. September 8, 2016

Notice of Intent to Create

VIMS Seawater Research Laboratory

Operational experience of the OP16 gas turbine in small scale CHP installations in Europe

Explanation of JCM Feasibility Study in Thailand & Applicable Low CO2 Emission Technology

Examining Applications Of Offshore Technology To Onshore Gas Compressor Stations For The Profitable Generation Of CO2-Free Power

Senior Thesis Report Spring Appendix - A. HAP Calculations without Enthalpy Wheel Excel Graphs

Optimizing Clean Energy Systems with Thermal Energy Storage and/or Turbine Inlet Cooling

FlexEfficiency* 60 Portfolio

University of Illinois at Chicago

CC Repowering WorkStation. Capital Cost Breakdown ( x $1000) for:

Achieving Significant Carbon Emissions Reductions through New Market-based Incentives

Transcription:

THE TECHNOLOGY AND MARKET ASSESSMENT FORUM Dallas, Texas Mario DeRobertis Eastern Regional Sales Manager Kawasaki Gas Turbines Americas

KAWASAKI CORPORATION Annual sales - $16 Billion Known for: Motorcycles, ATV s, Jet ski s; 10% of sales Kawasaki Concours 14 Motorcycle of the year 2008

KAWASAKI CORPORATION Worlds Fastest jet Ski Ultra 250 250 Hp Turbo charged - fuel injected Too cool!

KAWASAKI CORPORATION Gas Turbines Generators - 12% of KHI sales Largest market share for GT s 10 Mw s an below 8000 Gas turbine engines sold! Most now sold into Combined Heat and Power projects

What is Cogeneration? Internal Combustion engine power plants - efficiency typically 20 to 45% efficient By utilizing the electric power plus the engine exhaust heat to displace other heat sources thermodynamic efficiencies quickly go to 75% - 82% resulting in large energy savings - Reduces fossil fuel consumption, and emissions - all good for a green planet

KAWASAKI PACKAGED POWER PLANTS Base Loaded units GPB06 (600 kw) GPB15 (1.5 Mw) GPB15X (1.5 Mw) GPB15+ (1.7 Mw) GPB30 (3.0 Mw) GPB60 (5.5 5 Mw) GPB70 (7/8.0 Mw) GPB180 (17.9 Mw)

Kawasaki GPB06 GT 600 kw GT Generation set

Kawasaki GPB15 GT Rated @ 1500 kw s Combustor Inlet Gearbox Electric Generator Exhaust Turbine Section

Kawasaki GPB15 GT 1,500 KW Gen Set This unit shown with electrical systems installed on skid normally installed in site buildings: 52G Breaker, MCC, battery back up system, controls, VFD start system In assembly - Kawasaki asaki Shop Houston TX

GPB 15 Engine Cut Away GPB15 1.5 MW GT engine Single silo type combustor Radial type yp compressor

Kawasaki GPB15X GT K-LEAN Catalytic combustion system World s lowest Nox emissions Gas Turbine 2.5 ppm NOx

GPB15X Package Greenest - 1500 kw GT Gen set 1 ppm Nox

GPB 15X with HRSG GPB15X waste heat boiler for Co-generation GT GEN-SET BYPASS STACK STACK Heat Recovery Steam Generator Turbine Exhaust

GPB15 - CHP Applications Exhaust Heat Recovery Steam Generator (HRSG) Ambient Air GPB15X Gas Turbine Generator Demin water In 1390 kw Fuel IN Steam to Process 11,000 lbs/hr Unfired

GPB30 GT Power Plant 3,000 kw s Gas turbine Gen set. Dual turbine inlets Dual Engines Single Generator Gear Box

GPB30 GT Power Plant 3,000 kw s Gas turbine Gen set. Inlet Filter house Dual Lube Oil Dual Engines coolers air cooled

GPB30 GT Power Plant 3,000 kw s Gas turbine Gen set.

3MW Annual CHP Savings. hr/ yr $ Millions USD @ 8000 operation ual Savings Ann 2.6 24 2.4 2.2 2 1.8 16 1.6 1.4 1.2 1 14 13 12 11 10 9 6 7 8 9 10 11 12 13 14 Fuel cost & steam value $/MM Btu

GPB70D GT Engine Assembly 6.5 MW s: 33% Electric Efficiency - 82% overall in CHP

GPB70 GT Engine Rated at 7.0 Mw s Cold end drive This unit for New York City Emergency power; one of two NYC units packaged at our Houston Shop

GPB80 GT Package 7,250 kw s GT Gen Set In cogeneration; plant thermal efficiency is 80% Unfired HRSG provides 36,000 lbs/ hr steam

GPB70 /80 GT Annual Savings Kawasaki GPB70D Cogen Annual Savings @ ISO @ 8400 hr/ Annual Savings $ Millions USD yr op peration 5.5 5 45 4.5 4 3.5 3 2.5 2 1.5 1 13 12 11 10 9 8 5 6 7 8 9 10 11 Fuel cost & steam value $/MM Btu w/ 36,000 lbs hr sat steam to process

GPB70D GT Package GT package lift to Roof top NYC April 2008

GPB70D GT Package 7 MW unit - Lift to Roof top NYC 2008 55 tons

GPB180 GT Package Power Plant 18,000 kw s GT Gen Set Uses our L20 GT engine

GPB180D GT Package Unit in combined Heat and Power (CHP) w/ Heat Recovery Steam Generator HRSG By-pass stack Inlet Air filters HRSG / boiler Turbine Gen Set

Kawasaki Mobile CHP Units 3 Mw mobile CHP units w / on board HRSG 2 x GPB15 GT s / trailer 54 ft long

Mobile CHP Units Kawasaki 3 Mw CHP GT Trailer 2 x GT generation units with 2 pressure level l HRSG on trailer Boiler rated to 600 psig has supplementary firing capability Unfired - 22,000 lbs /hr saturated steam available for Co-gen 2xGT s gen sets per trailer

Mobile Units Annual CHP Savings Kawasaki MCU Cogen Annual Savings @ 8000 hr/ Annual Savings $ Millions USD yr op peration 25 2.5 2 1.5 1 05 0.5 0 14 13 12 11 10 9 6 7 8 9 10 11 12 13 14 Fuel cost & steam value $/MM Btu w/ 16,900 lbs hr sat steam to process

Emergency GT units Dual fuel Natural gas & Diesel Kawasaki GPS units - 12 GT models from 400 to 4000 kw s Dual Fuel capable! gas fueled; extended runs Exhaust Silencer Quick Emergency Start: Kawasaki GPS Units at full power in 40 seconds!

Kawasaki Standby Model GENSET ENGINE OUTPUT MODEL MODEL (ISO BASELOAD) GPS250 S1A-03 250 kva GPS500 S1T-03 500 kva GPS750 S2A-01 750 kva GPS1250 M1A-01 1250 kva GPS1500 M1A-03 1500 kva GPS1750 M1A-06 1750 kva GPS2000 M1A-23 2000 kva GPS2500 M1T-01S 2500 kva GPS3000 M1T-03 3000 kva GPS3500 M1T-06 3500 kva GPS4000 M1T-23 4000 kva GPS4500 M1T-23S 4500 kva GPS5000 M1T-33A 5000 kva GPS6000 M1T-33 6000 kva

Emergency GT Units Dual fuel Natural Gas & Diesel

Kawasaki Emergency GT Units Dual fuel Natural Gas & Diesel Light Weight - Roof Mounted GPS Units -

FEDERAL 10% TAX CREDIT On 10/3/08, President Bush signed into law the Emergency Economic Stabilization Act of 2008. authorizing.... the Treasury to spend up to $700 billion to purchase distressed assets,. the law. creates a new 10 percent investment tax credit (ITC) for CHP and waste energy recovery systems. The CHP ITC is a 10 percent tax credit for the first 15 MW of a system up to 50MW. The CHP ITC extends... through December 31, 2016.

State Grants for CHP Other States with significant CHP cogeneration grants Connecticut New York New Jersey North Carolina Texas

LEED Certification KAWASAKI CORPORATION THANKS YOU FOR YOUR PARTICIPATION ARE THERE ANY QUESTIONS YOU WOULD LIKE ANSWERED AT THIS TIME?

KGTA Contacts EAST COST & CANADA MARIO DEROBERTIS - (908) 723-3392 3392 mario.derobertis@kmc-usa.com WEST COAST & LATIN AMERICA (281) 970-3255 Ext. 18 steve.cernik@kmc-usa.com KAWASAKI GAS TURBINES AMERICAS 8829 NORTH SAM HOUSTON PKWY WEST HOUSTON, TEXAS 77064 Phone: 281-970-3255 Fax: 281-970-6465 http://www. kawasakigasturbines.com