Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector

Similar documents
Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution

Emulation of the Agilent 1100 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture

Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety

Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics

Application Note. Abstract. Authors. Introduction. Environmental

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Application Note. Authors. Abstract. Introduction. Pharmaceutical

Analysis of Monoclonal Antibody (mab) Using Agilent 1290 Infinity LC System Coupled to Agilent 6530 Accurate-Mass Quadrupole Time-of-Flight (Q-TOF)

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

Determination of Asarinin in Xixin (Asari Radix Et Rhizoma)

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit

Automated Scouting of Stationary and Mobile Phases Using the Agilent 1290 Infinity II Method Development Solution

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Quantification of Host Cell Protein Impurities Using the Agilent 1290 Infinity II LC Coupled with the 6495B Triple Quadrupole LC/MS System

Automated alternating column regeneration on the Agilent 1290 Infinity LC

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Method Transfer from an Agilent 1200 Series LC to an Agilent 1260 Infinity II LC

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system

Agilent 1290 Infinity Binary LC System with ISET Emulation of a Waters Alliance 2695 LC Applying Concave, Convex, and Linear Gradients

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Minimizing Sample Carryover Using the Multiwash Function of the Agilent 1290 Infinity II Multisampler

Reproducible LC/MS Peptide Separation Using Agilent AdvanceBio Peptide Plus Columns

The Agilent Metabolomics Dynamic MRM Database and Method

Increased Throughput in the Determination of PPCPs in Water Using Optimized MS Cycle Times in a High Sensitivity UHPLC-Triple Quadrupole System

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

High-Throughput LC/MS Purification of Pharmaceutical Impurities

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Performance characteristics of the 1260 Infinity Quaternary LC system

Authors. Introduction. Experimental. Environmental Analysis

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Analysis of Trace Organic Contaminants in Water by Direct Injection Using Agilent 6490 LC/MS/MS with Pos/Neg Switching

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Developing Purification Strategies for the Agilent 1260 Infinity II Preparative LC/MSD System

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

ANALYSIS OF MYCOTOXINS IN FOOD MATRICES

EPA Method 540: Selected Organic Contaminants Using Agilent Plexa Cartridges and the Agilent 6460 Triple Quadrupole LC/MS

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Analysis of Monoclonal Antibody N-glycans by Fluorescence Detection and Robust Mass Selective Detection Using the Agilent LC/MSD XT

Agilent 1290 Infinity Quaternary LC Support of Columns with 2.1 to 4.6 mm ID to 1200 bar

Characterize mab Charge Variants by Cation-Exchange Chromatography

Method Transfer from an Agilent 1260 Infinity LC to an Agilent 1260 Infinity II LC

Screening for Emerging Chemical Contaminants in Water Using LC/Q-TOF and Mass Profiler Professional Software

Improved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD)

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

Separation of Native Monoclonal Antibodies and Identification of Charge Variants:

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Analysis of per/polyfluoroalkyl substances (PFASs) in drinking water using the Agilent Ultivo triple quadrupole LC/MS

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

High Speed, Ultra-High Sensitivity, and Robustness Needed for the Quantitation of Pharmaceuticals in Blood Plasma. Application Note. Authors.

Monitoring of Mammalian Cell Culture Media with HILIC LC/MS

Development and evaluation of Nano-ESI coupled to a triple quadrupole mass spectrometer for quantitative proteomics research

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Determination of Table 3 Compounds by LC/MS/MS Chemours Fluoroproducts Analytical Method Revision date: 4/26/2018

Performance characteristics of the Agilent 1100 Series capillary LC system using diode-array UV and MS for detection. Technical Note.

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Environmental. Agilent 1290 Infinity Binary LC. with ISET and fine-tuning. Agilent 1290 Infinity Binary LC.

New Advances in UHPLC -Resolution, Speed & Sensitivity

Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system

Profiling Glycosylation of Monoclonal Antibodies at Three Levels Using the Agilent 6545XT AdvanceBio LC/Q TOF

LC/MS/MS Determination of PFOS and PFOA in Water and Soil Matrices

Application Note. Abstract. Authors. Environmental

Agilent 1290 Infinity LC with ISET under Waters Empower control Emulation of Agilent 1100 Series LC

Agilent 1290 Infinity Binary LC System with ISET - Emulation of the Waters Alliance 2695 LC system analyzing b-blockers

Cell Culture Optimization Using an Agilent Bio-Monolith Protein A Column and LC/MS

Application Note. Author. Abstract. Small Molecule Pharmaceuticals & Generics. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

ISET. Agilent 1290 Infinity Binary LC with ISET, emulation of the Waters Alliance 2695 LC system analyzing aromatic acids. Application Note.

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

Application Note. Author. Abstract. Pharmaceuticals. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Rapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column

Application Note. Biopharma. Authors. Abstract. James Martosella, Phu Duong Agilent Technologies, Inc Centreville Rd Wilmington, DE 19808

10. Validated Normal Phase HPLC Method for the Determination. Fulvestrant is primarily used in the treatment of hormone receptor

Application Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore, India

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Reversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 300SB-C8 1.

Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

Jet Stream Proteomics for Sensitive and Robust Standard Flow LC/MS

Practical Applications of Method Translation Using the Agilent Method Translation Tool. eseminar and Workshop

Fast Analysis of Environmental Phenols with Agilent Poroshell 120 EC-C18 Columns

Comparing gradient transfer of isocratic hold and delay volume addition using the Agilent 1290 Infinity LC with ISET

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

Expand Your Research with Metabolomics and Proteomics. Christine Miller Omics Market Manager ASMS 2017

Antibody Analysis by ESI-TOF LC/MS

A Comprehensive Approach for Monoclonal Antibody N-linked Glycan Analysis from Sample Preparation to Data Analysis

Method Translation in Liquid Chromatography

Fast Method Development Using the Agilent 1290 Infinity Quaternary LC System with Column Selection Valve

AdvanceBio Peptide Mapping

Genotoxicity is the property of a compound

Increasing Throughput and Efficiency with Exactive LC/MS and Triple Quadrupole LC/MS/MS

Analysis of amoxicillin and five impurities on the Agilent 1220 Infinity LC System

Agilent 6400 Series Triple Quad LC/MS System

Supporting Information

Transcription:

Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector Application Note Clinical Research Author Patrick Cronan Agilent Technologies, Inc. Lexington, Massachusetts, USA Introduction Nucleosides (adenosine, cytosine, guanosine, inosine, and uridine) are the structural subunits of nucleic acids. They are the biochemical precursors to nucleotides, and the building blocks of DNA and RNA. Nucleotides are essential to biological cell functions including data storage, energy production, cellular signaling, and coenzyme catalysis. As biological therapies are employed in our health care treatments, quick and easy detection of biological material, including nucleosides, becomes necessary. LC/MS detection of nucleosides can be tricky since many molecules are positional isomers with the same molecular weight and the same m/z value. LC/MS methods tend to use long shallow gradients for accurate separation, as accurately separating the nucleosides on the UHPLC column is essential for correct mass detection. An Agilent 1290 Infinity II high speed UHPLC system was used to develop a sub-10 minute LC method, achieving baseline resolution of 10 nucleosides without ion pair reagents. This, coupled to an Agilent 6100 Series Mass Selective Detector (MSD), enabled accurate characterization of all sample components with a limit of detection (LOD) of < 25 pg/µl.

Materials and Methods The Nucleosides Test Mix (p/n 47310-U) was purchased from Sigma-Aldrich. All chemicals and solvents were HPLC grade. Table 1 shows sample concentrations based on stock nucleoside concentration by dilution of the test mix to 1:10, 1:50, 1:100, 1:500, 1:1,000, 1:5,000, and 1:10,000. The following configuration was used for the experiments: Agilent 1290 Infinity II Binary Pump with integrated vacuum degasser (G7120A) Agilent 1290 Infinity II Multisampler plumbed with ultra-low dispersion tubing kit (G7167A) Agilent 1290 Infinity II Multicolumn Thermostat (G7116A) Agilent 1290 Infinity II Diode Array Detector with 10 mm max light flow ultra-low dispersion (ULD) cell (G7117A) Agilent 6130 Single Quadrupole MSD with Jet Stream ESI source Agilent ZORBAX Eclipse Plus C18 column 2.1 100 mm, 1.8 µm Instrument conditions HPLC conditions Instrument: Agilent 1290 Infinity II Binary pump, multisampler, multicolumn thermostat, DAD Column: Agilent ZORBAX Eclipse Plus C18 2.1 100, 1.8 µm Column temp.: 50 C Injection volume: 4 µl Mobile phase: A) Water 0.1% formic acid B) 80:20 Water:ACN 0.1% formic acid Flow rate: 0.1 to 0.8 ml/min Gradient: Time (min) %A %B Flow (ml/min) 2.5 100.0 0 0.1 3.5 99.2 0.8 5.0 98.2 1.8 0.8 6.5 96.8 3.2 7.0 0 100 7.5 0 100 7.6 100 0 Stop time: 9 min Post time: 0 min Overall run time: 9.5 min MS conditions Instrument: Agilent Jet Stream 6130 Mass Spectrometer Ion mode: AJS, ESI, positive Gas temp.: 300 C Drying gas flow: 12 L/min Nebulizer gas: 50 psi Capillary voltage: 1,300 V Nozzle voltage: 2,000 V Sheath gas flow: 11 L/min Sheath gas temp.: 250 C Table 1. Nucleoside dilution series concentration. Thiocytidine 2-O-Methylcytidine Guanosine, Inosine, 1-Methyladenosine, 7-Methylguanosine, Pseudouridine, Uridine Cytidine, Ribothymidine 5-Methylcytidine, 3-Methylcytidine Stock standard 10,000 µg/µl 20,000 µg/µl 25,000 µg/µl 50,000 µg/µl 100,000 pg/µl 10x 1,000 pg/µl 2,000 pg/µl 2,500 pg/µl 5,000 pg/µl 10,000 pg/µl 50x 200 pg 400 pg 500 pg 1,000 pg 2,000 pg 100x 100 pg 200 pg 250 pg 500 pg 1,000 pg 500x 20 pg 40 pg 50 pg 100 pg 200 pg 1,000x 10 pg 20 pg 25 pg 50 pg 100 pg 5,000x 2 pg 4 pg 5 pg 10 pg 20 pg 10,000x 1 pg 2 pg 2.5 pg 5 pg 10 pg 2

Results and Discussion The goal of this separation was chromatographic resolution to enable accurate LODs and limits of quantitation (LOQs) of 12 nucleosides in under 10 minutes (Figure 2). After the dilution series was analyzed in triplicate, linear regression lines were plotted. Figure 1 shows the most and least abundant nucleoside. The linear regression plot shows good correlation over four orders of magnitude, with R 2 values of 0.999 at the LOD of each nucleoside. All 12 nucleosides can be detected with extracted ion chromatograms from the Agilent 6130 Single Quadrupole MSD (Figure 2). Ten of 12 nucleosides are chromatographically resolved, demonstrating the advantage of mass spectrometry for difficult-to-resolve compounds. The LODs for 12 nucleosides ranged from < 4 50 pg/µl, and the LOQs ranged from <10 250 pg/µl. All statistics can be found in Table 2. The retention time reproducibility for all 21 injections was < 0.3% RSD (Table 3). AVG Response AVG Response A 400,000 3-Methylcytidine 350,000 300,000 250,000 200,000 150,000 100,000 50,000 R² = 0.9994 0 0 20 40 60 80 100 120 Standard concentration (pg/µl) B 90,000 Uridine 80,000 R² = 0.999 70,000 60,000 50,000 40,000 30,000 20,000 10,000 0 0 50 100 150 200 250 300 Standard concentration (pg/µl) Figure 1. Linear Regression lines for an abundant (3-Methylcytidine, A) and least abundant (Uridine, B) nucleoside at LOD/LOQ. 5-MC, 1-MA Guanosine, Inosine Counts Cytidine PS 3-MC Uridine Thiocytidine Ribothymidine MSD TIC LC DAD 7-MG 2-O-MC 3 4 5 Acquisition time (min) Figure 2. Red: Total ion chromatogram from MS showing the separation of 12 nucleosides. Blue: Diode array detector signal of the chromatographic separation of 10 of the 12 nucleosides in the standard. 3

Table 2. LOD and LOQ calculations for all 12 nucleosides present in the standard text mix. Peak 1 Nucleoside S/N LOD (pg/µl) S/N LOQ (pg/µl) Formula MI Mass m/z (1+) 1 Cytidine 5.8 <5 10 <10 C 9 H 13 243.08 244.1 2 Pseudouridine 4.3 <25 26.9 <250 C 9 H 12 N 2 O 6 244.07 245.2 3 3-methylcytidine 8.3 <10 17.7 <20 C 10 257.1 258.2 4 5-methylcytidine 9.2 <10 22.3 <20 C 10 257.1 258.2 5 1-methyladenosine 5.0 <5 25.1 <25 C 11 O 4 281.11 282.2 6 Uridine 3.2 <25 24.1 <250 C 9 H 12 N 2 O 6 244.07 245.2 7 Thiocytidine 7.6 <20 10.2 20 C 9 H 13 O 4 S 259.06 260.1 8 7-methylguanosine 4.6 <25 45.3 <250 C 11 297.11 298.2 9 2-O-methylcytidine 4.4 <4 22.2 <20 C 10 257.1 258.2 10 Inosine 8.7 <25 14.1 <50 C 10 H 12 268.08 269.2 11 Guanosine 7.6 <25 12.2 25 C 10 H 13 283.09 284.2 12 Ribothymidine 6.1 <50 11.4 <100 C 10 H 14 N 2 O 6 258.09 259.1 Table 3. Excellent percent RSDs for the standard test mix on the Agilent 1290 Infinity II demonstrating overall system reproducibility. All values are less than 0.3% RSD. Cytidine PS 3-MC 1-MA 5-MC Uridine Thiocytidine 7-MG 2-O-MC Guanosine Inosine RBT Mean 2.82 2.96 3.14 3.27 3.30 3.52 3.60 3.67 3.79 4.25 4.25 4.56 Std dev 0.0069 0.0085 0.0036 0.0057 0.0031 0.0031 0.0028 0.0044 0.0023 0.0025 0.0025 0.0038 %RSD 0.246 0.289 0.114 0.173 0.093 0.087 0.080 0.121 0.062 0.058 0.058 0.082 PS = Pseudouridine, 3-MC = 3-Methylcytidine, 1-MA = 1-Methyladenosine, 5-MC = 5-Methylcytidine, 7-MG = 7-Methylguanosine, 2-O-MC = 2-O-Methylcytidine, RBT = Ribothymidine 4

Conclusions The Agilent 1290 Infinity II UHPLC system coupled with the Agilent 6130B Single Quadrupole MSD provides an optimal solution to attain low limits of detection for closely eluting nucleosides. The low delay volume and active dampening of the Agilent 1290 Infinity high speed pump enables better resolution with shorter analysis times, leading to improved mass spectral sensitivity. For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. 5

www.agilent.com/chem For Research Use Only. Not for use in diagnostic procedures. This information is subject to change without notice. Agilent Technologies, Inc., 2016 Printed in the USA May 5, 2016 5991-6871EN