ICD High Performance Coatings. Contractor Manual OPACI-COAT-300 WATER-BASED SILICONE GLASS SPANDREL APPLICATION AND INSTALLATION GUIDE

Similar documents
ICD High Performance Coatings. Contractor Manual

OPACI-COAT Water-base Silicone Glass Coating

OPACI-COAT Water-base Silicone Glass Coating

Section Glass Wall Cladding

Spandrel Glass Types and Recommendations

ARCH 478 OFFICE BUILDING SECTION GLAZING

Section Spandrel Glass

S P A N D R E L SPECIFICATION GUIDE

SSG. Fundamentals of Structural Sealant Glazing. Introduction

ROOF REPLACEMENT AND ALTERATIONS TO WOODSTOCK Barrett Architecture, PC WASTE WATER TREATMENT FACILITY - Woodstock, VT February 28, 2019 SECTION

3M Plastic Primer P591. Color Clear Black Black Clear Black Clear. (Ford Cup) Solids (%) VOC (g/l)

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

Alabama A&M University Laundry Building at Normal Hill Apartments Project No ADDENDUM NUMBER 4

Cleaning Instructions Glass GG

LOG COLLEGE MIDDLE SCHOOL

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Adhesion Promoter/Primer 3M Adhesion Promoter AP596

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

PROJECT NO August 19, 2014 SENATE CHAMBER MEZZANINE RENOVATION MISSOURI STATE CAPITOL BUILDING SECTION JOINT SEALANTS

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

SECTION GLAZING. A. Section Includes: 1. Glass for other sections referencing this Section.

A typical structural glazing system is composed of a number of essential components:

Product Data Sheet Edition 25/01/2006. Sikasil WS-305. Product Description. Uses. Characteristics / Advantages

Extreme Sealing Tape

SECTION DECORATIVE GLASS GLAZING. A. Decorative specialty glass glazing for interior applications, including:

DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING

SECTION 07530CP EPDM MEMBRANE ROOFING

Introduction to Caulks & Sealants. Ensuring Envelope Integrity with Joint Sealants

Repair Maintenance Hangar Phase II August 2010

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

Color Clear Black Black Clear Black. Viscosity seconds seconds Water Thin (DIN Cup) (Ford Cup) Water Thin 50 MPa*s

SECTION GLAZING

Contractors SCS1001. Contractors SCS1000 sealant is available in 4 colors plus. General Glazing: Glass, plastic, channel or stop.

Building Systems. 1-Part Silicone Weatherseal for Structural Glazing. Product Description. Product Data Sheet Edition_1, 2009 Sikasil WS-305 CN

Polyisobutylene (PIB) Primary Sealant

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage:

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage:

B. Mirror glass for toilet rooms is specified in Section "Toilet Accessories."

SECTION GLAZING ADDENDUM 10 APRIL 20, 2011

TECHNICAL BULLETIN TB-1800-XX. Unsupported Edge Conditions of Insulating Glass Units

SEALANTS: THE LOWEST COST, HIGHEST RISK PRODUCTS IN GLAZING CARL TOMPKINS NATIONAL FLAT GLASS SALES MANAGER, SIKA CORPORATION

JE Berkowitz, L.P. (updated ) B. The basis of design is the JEB Invisiwall Wall (Point Supported) by JE Berkowitz, LP. C.

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL

PAYING ATTENTION TO DETAIL by Bob Cusumano

Poly and Anti Graffiti Films Clear exterior films safeguarding plastic substrates from scratches, discoloration and graffiti.

Multi-Institutional Academic Health Science & Research Center Evansville, IN

V60 Architectural Grade Silicone

Single Component 100% Silicone Sealant INSTALLATION INSTRUCTIONS

Technical Bulletin July, 2013

JONES AIRWAYS, LLC CLEVELAND REGIONAL JETPORT SECTION GLAZING

Glass Splashback Guidelines and Recommendations

United Professional Caulking & Restoration, Inc. Joint Surface Preparation and Sealant Application

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

SOTA THERMO 3 SERIES SPECIFICATION FOR PREGLAZED & UNITIZED THERMO 3 CURTAINWALL SYSTEM

Pacific Polymers Elasto-Deck 5000MR Guide Specification

RECOMMENDED DESIGN SPECIFICATION

SPECIFICATION For the Supply and Installation of BRITAL UN Four Sided Unitized Structurally Glazed Curtain Walling

YES SSG TU Vent Window System

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Architectural Series Framing

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

RTV142. Technical Data Sheet

Wabo FireShield Model: FSH

SECTION PENETRATION FIRESTOPPING PART 1- GENERAL PART 2- PRODUCTS 1.1 RELATED DOCUMENTS

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Moisture Requirements Moisture testing must be performed. Patcraft requires the use of the following test methods:

Extreme Sealing Tape 4412N

I C D Industrial Control Development, Inc. Phone: NW Third Court, Suite 100 Fax:

V-70. High Strength Structural Glazing Silicone Adhesive Sealant

3 500-Series Polyurethane Products:

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

Typical Properties Specification Writers: These values are not intended for use in preparing specifications.

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Standard Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications 1

SECTION DETAILS (MECHANICALLY ASSEMBLY)

SECTION GLAZING

OPACI-COAT 300 SPANDREL GLASS. DATA SHEET / Quebec. Version 2.1

SECTION JOINT SEALERS 1.03 THIS SECTION INCLUDES JOINT SEALERS FOR THE FOLLOWING LOCATIONS:

3 700-Series Hybrid Products:

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

.2 Section Waste Management and Disposal.

SECTION EPOXY TERRAZZO TILE WITH RECYCLED GLASS MATRIX

Install & Maintenance Instructions

SECTION GLASS AND GLAZING (WINDOWS)

IS800 Series adhesive sealants utilize a moisture vapor cure system and release acetic acid vapors from the sealant surface as a by-product of cure.

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

Note: Installation and Glazing Manuals are product specific. FOR REVIEW ONLY! FEBRUARY 2012

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

Bovard Studio Inc. Section July 22, 2003 Page 1

SOTA HYBRID-WALL SPECIFICATION FOR PRE-GLAZED & UNITIZED HYBRID-WALL SYSTEM

SECTION GYPSUM BOARD ASSEMBLIES

A. Section Includes: B. Proceed with installation only after unsatisfactory conditions have been corrected.

RTV5249. Technical Data Sheet

SunWave Prismatic Skylights

SECTION / STC 52 METAL SOUND CONTROL DOORS

SECTION GLAZING

SECTION aa STRUCTURAL TAPE GLAZING

Transcription:

ICD High Performance Coatings Contractor Manual OPACI-COAT-300 WATER-BASED SILICONE GLASS SPANDREL APPLICATION AND INSTALLATION GUIDE January 2015 1

Although ICD has made every effort to ensure that the information in this book was correct at press time, ICD does not assume and hereby disclaim any liability to any party for any loss, damage, or disruption caused by errors or omissions, whether such errors or omissions result from negligence, accident, or any other cause. This manual is superseded by ICD s standard product warranty and does not constitute a change in such. www.icdcoatings.com 2

Contents Contractor Manual... 1 Introduction... 4 Importance of a Glazing Manual... 4 Component Testing... 5 How to Use Sealants & Adhesives... 6 Preparing the Spandrel Surface... 7 Wall Cladding Wall Preparation... 8 General Do s & Don ts... 9 Monolithic Spandrel Application... 10 Insulated Glass Unit Spandrel... 11 Wall Cladding Detail <60 in Height... 12 Wall Cladding Detail >60 in Height... 13 Plan Review & Two- Sided Structural Glazing... 14 Most Common Installation Problems... 15 3

Introduction ICD High Performance Coatings manufactures paints and coatings. Historically, we have developed and manufactured coatings for the architectural glass markets, specifically spandrel coatings and interior wall cladding. Today, we are seen as both experts in silicone coating technology and providing coatings solutions where none previously existed. In 1986, we started ICD with the desire to create green and healthy alternatives to glass coatings on the market, which spawned our flagship product OPACI- COAT- 300. Headquartered in Vancouver, Washington, USA, ICD reaches customers and markets globally by working directly with customers, maintaining a representation net- works and strategic manufacturing in other locations. We reach the glass market by providing architects and designers with tools for success, allowing them to specify our products with sound principles. Our products are sold to glass fabrication plants across the globe, which become part of the ICD Approved Factory Fabricator program. We also make other products for glass, as well as metals and plastics, such as polycarbonate. compatibility- testing program, there are too many products that may come in contact with our coating and each other. Possibly coming together to create an undesired effect that may be visible in your finished glazing. As well, the glass industry has created standardized configurations that ensure success throughout your project. This manual is an accumulation of close to thirty years of experience in the glass and glazing industry. These are keys to ensuring not only your success with our products, but with all the others you may be using on your project. Importance of a Glazing Manual The reason this manual is so important is purely due to the many variables that will go into glass glazing. Even with a full component 4

advocacy, standard setting, and leadership. One of the best documents to read is the GANA Glass Informational Bulletin DD 02-1111 Assessing the Compatibility of Glazing materials and Components. Click the following link to either download or buy it, worth every bit of those five US Dollars. GANA Glass Informational Bulletin DD 02-1111 Assessing the Compatibility of Glazing materials and Components (http://store.glasswebsite.com/) Component Testing Our Component testing program consists of a thirty day UV exposure test of any of the components you with to have tested, in conjunction with our OPACI- COAT- 300 coating. It is a modified version of the ASTM International C 1087 test standard. The reason we use UV and thirty days is it is a very harsh test that will accelerate a potential chemical or mechanical reaction that may occur months after a building has been completed. We will provide you a report on how well the products performed with each other and if we endorse using that product on the project. If we deem a product is not a good choice, and it is still used, any problems with the installation will be outside our warranty scope. If you are not currently aware of who the Glass Association of North America (GANA) is, you should seek them out. This is an association of our industry that seeks to serve in 5

years of experience in the glass and glazing industry. These are keys to ensuring not only your success with our products but with all the other products you may be using in your project. For a complete and updated list of approved sealants and materials that have been tested in our compatibility program, please see the links below. Please note that compatibility is between the single component and the coating. How to Use Sealants & Adhesives The reason for this manual and other manuals by component manufacturers is due to the many variables that will go into glass glazing. Even with a full component compatibility- testing program, there are too many products that may come into contact with our coating and each other. Possibly coming together to create an undesired effect that may be visible in your finished glazing. The glass and glazing industry has created standardized configurations that ensure success throughout your project. This manual is an accumulation of close to thirty ICD does not claim to guarantee the compatibility of other components, like sealants, to each other and other products used in the glazing. Always seek a compatibility test and report from all suppliers. When applying your adhesives, it is very important to check with the manufacturer to ensure proper use. Generally speaking, the applied blob of sealant should be should be no more than a half- inch in diameter. This results in no more than a one- inch diameter circle of sealant in compression when the glass is pressed to the wall. As well, the applied blobs should not be more or less than eighteen inches (18 ) from each other. This allows for adequate coverage for a proper hold by the sealant as well as enough air space to allow for proper cure of the sealant. 6

Figure 1 shows the most common configuration for applying the adhesive. Starting at ½ when applied, the sealant results in about a one inch circle after the glass has been pressed onto the wall. Please note that it is advised to either seek a recommendation from the manufacturer on how long your adhesive will take to cure before using any perimeter sealants. You should Figure 1 wait twenty- one days to allow for cure and all solvents in the sealant to migrate away from the area. Each sealant and manufacturer will have differing amounts of time for a proper cure, check with them. Approved Materials List on AFF Portal (login required): http//www.icdcoatings.com/aff- portal/ Approved Materials List on Contractor Portal: http://icdcoatings.com/contractor- portal/ If you do not see a component on the list, please contact ICD. Great care is taken at the fabricator level to ensure the glass is clean and free of debris before applying and curing the spandrel coating. Between the fabricator s facility and the job site, debris can again accumulate on the spandrel coating and glass. Debris may increase in quantity the longer the crates of coated glass sit at the job site. Below is a quick procedure for ensuring the spandrel coating is clean for the best possible sealant adhesion. Simple Cloth & IPA Clean Clean, soft, absorbent, lint- free cloths must be used. This method uses two solvent wipes. The solvent isopropyl alcohol, easy enough to find at your corner drug store as rubbing alcohol. 1. Remove any obvious debris visible, especially where the sealant will be applied. 2. Pour or dispense the IPA onto the cloth. A plastic (solvent resistant) squeeze bottle works best as dipping the cloth into the solvent bottle may cause contamination. 3. Wipe the spandrel surface where the sealant is to be applied, with the IPA and cloth. 4. Repeat the steps above. 5. Wait 5-10 minutes for the alcohol to fully flash off the coating. 6. Apply the sealant as recommended by ICD and the manufacturer. Preparing the Spandrel Surface 7

Wall Cladding Wall Preparation When working with wall cladding, it is important to pay attention to the wall the glass is being adhered to. If you have a bare concrete wall and/or wood, the surface must first be primed with a latex primer. Take care to not install the coated glass over cloth, wallpaper or plastic, it must be primed sheet rock. Glass installed over 60 above the floor will require mechanical supports to carry the glass dead load. This is a code issue; your local code rules need to be consulted. As always, ensure you are not suing hydrocarbon- based gaskets, setting blocks, etc. Do not use an EPDM unless it has been approved by ICD. Do not use any neoprene products at all in contact with the glass coating. To be safe, always use the same sealant to attach the coated glass to the wall as you use for sealing of the butt joints. Mixing of sealants may cause an adverse effect. Always seek approval from your sealant manufacturer about the suitability of that sealant as a wall cladding adhesive and that it is approved to be used with a different butt joint sealant if you so desire. 8

General Do s & Don ts Do use only compatible sealants, gaskets, insulation, etc. Do use only neutral cure silicones as adhesives. Do follow the sealant manufacturer s recommendations for application and cure. Do seek approval from sealant manufacturer for use in your project. Do Not use acid- based materials such as sealants and gaskets. Do Not use mirror mastics as an adhesive. Do Not use double- faced tapes. Do Not use neoprene products, such as setting blocks, where they come in contact with the coating. Do Not use hydrocarbon solvents or materials. Figure 3, example of a label, you may see on the glass as it comes from an AFF. The purpose of this label is to be a quick reminder of the above points. Please note that the web address for the Contractor Guide is incorrect on this version of the label it is: http://www.icdcoatings.com/contract or- guide/ Figure 1 9

Monolithic Spandrel Application 10

Insulated Glass Unit Spandrel *Please note that the #3 surface is not recommended for OPACI- COAT- 300 if a low- e is on the #2 glass surface. Doing so may create a rainbow effect when light strikes the glass from a certain angle. 11

Wall Cladding Detail <60 in Height Please note that the time required to properly allow a sealant to cure may be up to twenty- one days, seeking the proper information from the manufacturer is critically important. 12

Wall Cladding Detail >60 in Height 13

Plan Review & Two- Sided Structural Glazing It is now possible to perform two- sided structural glazing without edge deletion of glass coated with OPACI- COAT- 300. Most sealant manufacturers, such as Dow Corning and Momentive, have completed adhesion testing with their silicone structural adhesives. The tests performed indicate that the sealant has acceptable adhesion to be approved for structural applications in contact with our coating. For example, Dow Corning will approve the use of Dow Corning 995 Silicone Structural Adhesive for use with our product on jobs where project specific adhesion testing has been successfully been completed. Successful testing of compatibility and adhesion must have been completed for our warranty to apply. In accordance with our warranty, the coating must have also been applied by an Approved Factory Fabricator. The glazing contractor would be responsible for component submittal to the sealant manufacturer completing the approval testing. For more information or access to submittal forms, please visit: www.icdcoatings.com/contractor- portal. 14

Most Common Installation Problems Insulation glued directly to the back of the product. A minimum 1 air gap must be kept between the coated back side of the glass and the insulation. Anything less will interfere with the weep system if used in a spandrel application or create water trap areas. Staining or Loss of Sealant Adhesion. This is a very common problem and stems from not seeking adequate approval from sealant manufacturers when mixing two different sealants, such as seen when one is used for the adhesive and the other for a perimeter seal. Most commonly seen in wall cladding. Always seek approval for use from the sealant manufacturer, never assume. Always follow recommended procedures for quantity of sealant, configuration, and adequate cure time before going to another sealant in the same area. Neoprene and hydrocarbon based products may also cause damage to our coating and other s silicone sealants. Sealant/Adhesive visible through the coating, over time. If you can see the ring of the adhesive and it measures a greater number than one inch in diameter, most likely you have applied too much sealant/adhesive, and it is not fully cured. Resulting in a staining at the center of the sealant/adhesive. Stained straight- line edge, usually on two sides where the mechanical fastening is. This is an incompatibility usually associated with neoprene or other incompatible gaskets having been used. Coating Loss of Adhesion, Blotch look, Or Other Staining Before Installation. It is very important to properly store all glass products in accordance with accepted practices. This information can be found on our Contractor Portal as well as through GANA. Job- site storage is of critical importance and leads to one of the most problematic areas where issues are seen. A modern job- site may have many chemicals, including rainwater, which will damage glass products, as well as our coating. 15

#3 surface... 11 acid- based materials... 9 adhesives... 6 air gap... 15 application and cure... 9 Approved Materials List... 7 approved sealants... 6 ASTM... 5 C 1087... 5 clean... 7 compatibility... 6 Component testing... 5 components... 6 Contractor Portal... 15 Do s... 9 Don ts... 9 double- faced tapes... 9 Dow Corning... 14 edge deletion... 14 GANA... 5 GANA Glass Informational Bulletin DD 02-1111 Assessing the Compatibility of Glazing Materials and Components... 5 hydrocarbon... 9 Insulated Glass Unit Spandrel... 11 Insulation... 15 IPA Clean... 7 Loss of Sealant Adhesion... 15 low- e... 11 mirror mastics... 9 Monolithic Spandrel... 10 neoprene... 9 neutral cure silicones... 9 perimeter sealants... 7 Plan Review... 14 Staining... 15 Two- Sided Structural Glazing... 14 Wall Cladding Detail <60... 12 Wall Cladding Detail >60... 13 weep system... 15 16