Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

Similar documents
Application Note. Author. Abstract. Pharmaceuticals. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Agilent 1290 Infinity Binary LC System with ISET - Emulation of the Waters Alliance 2695 LC system analyzing b-blockers

Agilent 1290 Infinity Binary LC System with ISET Emulation of a Waters Alliance 2695 LC Applying Concave, Convex, and Linear Gradients

Analytical Instrument Qualification According to USP <1058>: Requirements and Examples for the Agilent 1290 Infinity LC System

Emulation of the Agilent 1100 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Performance characteristics of the 1260 Infinity Quaternary LC system

Analysis of amoxicillin and five impurities on the Agilent 1220 Infinity LC System

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system

Method Transfer from an Agilent 1200 Series LC to an Agilent 1260 Infinity II LC

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

ISET. Agilent 1290 Infinity Binary LC with ISET, emulation of the Waters Alliance 2695 LC system analyzing aromatic acids. Application Note.

Agilent 1290 Infinity Quaternary LC Support of Columns with 2.1 to 4.6 mm ID to 1200 bar

Application Note. Environmental. Agilent 1290 Infinity Binary LC. with ISET and fine-tuning. Agilent 1290 Infinity Binary LC.

easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

Fast Method Development Using the Agilent 1290 Infinity Quaternary LC System with Column Selection Valve

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Comparing gradient transfer of isocratic hold and delay volume addition using the Agilent 1290 Infinity LC with ISET

Peptide Mapping: A Quality by Design (QbD) Approach

Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

Protein Separation with ph Gradients Using Composite Buffer Systems Calculated by the Agilent Buffer Advisor Software

Automated Scouting of Stationary and Mobile Phases Using the Agilent 1290 Infinity II Method Development Solution

Analytical HPLC solutions

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

High-Throughput LC/MS Purification of Pharmaceutical Impurities

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system

10. Validated Normal Phase HPLC Method for the Determination. Fulvestrant is primarily used in the treatment of hormone receptor

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

Qualification of High-Performance Liquid Chromatography Systems

Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

Method Translation in Liquid Chromatography

Application Note. Author. Abstract. Small Molecule Pharmaceuticals & Generics. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Automated alternating column regeneration on the Agilent 1290 Infinity LC

Application Note. Authors. Abstract. Biopharmaceuticals

Automated QbD-Based Method Development and Validation of Oxidative Degraded Atorvastatin

Reversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 300SB-C8 1.

Agilent 1220 Infinity LC. Infinitely more affordable

Simplifying Methods Transfer: Novel Tools for Replicating Your Established Methods on an ACQUITY Arc System

A Simple Rapid and Sensitive Method Development for Quantification of Quetiapine Fumarate in Bulk and Dosage Forms Using RP-HPLC

Agilent 1260 Infinity Purification Systems. Infinitely better purity and recovery

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Improved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD)

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

The Agilent 1260 Infinity BioInert Quaternary Pump. Scope of a low-pressure mixing UHPLC pump with Bio-Inert Capabilities

ultra why micro-lc? product note introducing the ExpressLC -Ultra system: UHPLC with all the advantages of micro-lc

Method Transfer from an Agilent 1260 Infinity LC to an Agilent 1260 Infinity II LC

Determination of Asarinin in Xixin (Asari Radix Et Rhizoma)

DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR ASSAY DETERMINATION OF ISOSULFAN BLUE BY LIQUID CHROMATOGRAPHY

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

Practical Applications of Method Translation Using the Agilent Method Translation Tool. eseminar and Workshop

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

Automated fraction re-analysis does it really make sense? Application. Udo Huber. Abstract

Gold Standard for recovery and purity

Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector

New Advances in UHPLC -Resolution, Speed & Sensitivity

Application Note. Biopharma. Authors. Abstract. James Martosella, Phu Duong Agilent Technologies, Inc Centreville Rd Wilmington, DE 19808

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

Analysis of TCM injections using the Agilent 1290 Infinity LC system

Rapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column

Encompassing Method Development, Small Scale Purification, and Post-Purification Analysis with the Investigator SFC System

Fast Analysis of Environmental Phenols with Agilent Poroshell 120 EC-C18 Columns

Agilent 1290 Infinity LC with ISET under Waters Empower control Emulation of Agilent 1100 Series LC

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Developing Purification Strategies for the Agilent 1260 Infinity II Preparative LC/MSD System

Available Online through (or) IJPBS Volume 2 Issue 3 JULY-SEPT Research Article Pharmaceutical Sciences

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

Impurity Control in the European Pharmacopoeia

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON ARTEMETHER AND LUMEFANTRINE CAPSULES REVISED DRAFT FOR DISCUSSION

Performance characteristics of the Agilent 1100 Series capillary LC system using diode-array UV and MS for detection. Technical Note.

Infinitely better. Agilent 1200 Infinity Series. Infinity LC. Infinity LC. Infinity LC. products applications soft ware services

Application Note. Authors. Abstract. Introduction. Pharmaceutical

NISTmAb characterization with a high-performance RP chromatography column

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System

DIDANOSINE ORAL POWDER Final text for addition to The International Pharmacopoeia

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

P. Wadhwani College of Pharmacy, Yavatmal , India. *Corres.author: Cell No

C196-E067A. Prominence UFLCXR. Shimadzu Ultra Fast Liquid Chromatograph

Lakshmana Rao et.al Indian Journal of Research in Pharmacy and Biotechnology ISSN: (Print) ISSN: (Online)

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

Techniques for Reducing the Effects of Sample Solvent on UHPLC Analyses

Molecular Characterization of Biotherapeutics The Agilent 1260 Infi nity Multi-Detector Bio-SEC Solution with Advanced Light Scattering Detection

DACLATASVIR TABLETS (DACLATASVIRI COMPRESSI) Proposal for The International Pharmacopoeia. (May 2018)

Peptide Mapping. Hardware and Column Optimization

Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B

A green HPLC technique with a 100% water mobile phase for detecting imidacloprid and its metabolite 6-chloronicotinic acid

Technical Note. Introduction

Quantitative determination of residual 2-(2-chloroethoxy) ethanol (CEE) in quetiapine fumarate by gas chromatogaraphy

Journal of Pharmaceutical and Bioanalytical Science

Transferring a Method from a Conventional 3.5 µm or 5 µm to an Agilent Poroshell 120 Column to Improve Analytical Speed and Resolution

Ultra High Performance Liquid Chromatograph. Nexera XR C196-E082C

IJSER. (2E)-2-cyano-3-(3,4-dihydroxy-5-nitrophenyl)-N,N-diethylprop-2-enamide [Entacapone] 7

Transcription:

Development, validation, and comparison of an HPLC method to analyze paracetamol and related impurities according to the European Pharmacopoeia (EP) and USP using the Agilent 1120 Compact LC and the Agilent 1200 Series LC system Application Note Pharmaceuticals Author 7 Retention Time Name Detlef Wilhelm ANATOX GmbH & Co. KG 6 VWD: Signal A, 24 nm Standard 2 Fuerstenwalde, Germany mau 4 3 2 1 2.00 - Impurity K 3.613 - Paracetamol.33 - Impurity B 6.633 - Impurity A 13.240 - Impurity H 30.420 - Impurity I 3.13 - Impurity J 0 0 10 1 20 2 30 3 40 4 Minutes Abstract This Application Note compares the results of the development of an accurate and reproducible method to analyze paracetamol and related impurities according to European Pharmacopoeia (EP) and USP regulations 1, using an Agilent 1120 Compact LC and a 1200 Series LC system. The experiments described in this Application Note include the determination of the precision of areas and retention times, as well as chromatographic parameters such as resolution and signal-to-noise ratios. The well-suited Agilent ZORBAX StableBond RP8 column shows good selectivity for this application. The results of these experiments prove that the Agilent 1120 Compact LC is a reliable instrument for routine testing that is able to fulfill the requirements of the European and U.S. regulations and can produce results comparable to those of a standard Agilent 1200 Series LC system.

Introduction The analytical instrumentation for routine analysis of samples with standardized LC methods, especially for quality control testing, have several requirements. Foremost are high reliability, ease of use, and an optimal cost of ownership. This Application Note shows how the Agilent 1120 Compact LC, in comparison with a standard Agilent 1200 Series LC system, works as a highly robust and reliable instrument for standard LC methodology and can be used effectively in a routine environment to efficiently measure pharmaceutical compounds, such as paracetamol and related impurities. According to the EP regulations, paracetamol impurities A, B, F, H, I, J, and K were analyzed on both LC systems, and system suitability and performance tests were executed. Experimental Instrumentation An Agilent 1120 Compact LC system and a standard Agilent 1200 Series LC system with the following configurations were used: Configuration of the 1120 Compact LC Gradient pump and vacuum degasser Auto sampler Column oven Variable wavelength detector Software: EZChrom Elite Compact 3.3 Configuration of the 1200 Series system Quaternary pump and vacuum degasser Standard autosampler Column compartment Diode array detector Software: ChemStation B.04.01 Preparation of samples The reference solution was prepared as follows, in accordance with EP regulations. mg of paracetamol and mg of each impurity were dissolved in methanol and diluted to 20 ml with the same solvent. 1 ml of the solution was diluted to 20 ml with mobile phase. The substances to be checked were paracetamol and impurities K, A, B, H, I, J, and F. Chromatographic conditions Column Agilent ZORBAX StableBond-C8, 4.6 x 20 mm, μm Mobile phase Mix together 37 ml of a 17.9 g/l solution of disodium hydrogen phosphate, 37 ml of a 7.8 g/l solution of sodium dihydrogen phosphate, and 20 ml of methanol containing 6 ml of a 400 g/l solution of tetrabutylammonium hydroxide in methanol Pump settings No gradient (in accordance with EP regulations) Stop time 4 min Flow rate 1. ml/min, isocratic Injection volume 20 μl Column compartment temp. 3 C Detector 1120 LC system 14 μl 1200 Series system 13 μl Peak width 0.1 min ( Hz) Signal 24 nm System suitability and performance test The EP regulations for paracetamol require system suitability testing with a reference solution, as described in Preparation of samples, above. The testing included the following limits: Resolution 4.0 minimum between peaks to impurity K and to paracetamol Signal-to-noise ratio 0 minimum for the peak due to impurity J Relative retentions Impurity K = 0.8 (paracetamol) Impurity F = 3 Impurity J = 7 2

No special regulations for paracetamol come from the USP. However, according to USPC Official 8/1/08, General Chapter <621> (Chromatography, System Suitability, p. 28) if there are no special requirements in the monographs, the data of five replicate injections should have a relative standard deviation of less than 2% for each calculated parameter. From these above-mentioned requirements and to check and compare the chromatographic performance of both LC systems, the following parameters were tested and the limit settings below were fulfilled: Precision of areas must be < 2% RSD Precision of retention times must be < 0.% RSD Resolution must be > 4 for impurity K and Paracetamol Signal-to-noise ratio must be > 0 for impurity J With these limits and settings for testing, the samples in Table 1 were prepared and analyzed. Sample Purpose Number of injections Blank solution Verify baseline stability and identify 2 artifacts Control sample Verify sensitivity and resolution for 6 reference solution Suitability sample Verify precision of areas and retention 10 times for reference solution Table 1 Setup for testing. 3

Results and discussion Figure 1 shows a chromatogram achieved with the 1200 Series system and ChemStation, whereas Figure 2 shows the chromatogram yielded with the 1120 Compact LC and EZChrom Elite Compact. The data for both chromatograms, shown in Tables 2 and 3, are very similar. mau 4 3 2 1 2.499 - Impurity K 3.660 - Paracetamol.44 - Impurity B 6.790 - Impurity A 13.704 - Impurity H 31.41 - Impurity I 37.022 - Impurity J 0 10 1 20 2 30 3 40 min Figure 1 Example chromatogram of paracetamol and impurities with the Agilent 1200 Series system. 7 Retention Time Name 6 VWD: Signal A, 24 nm Standard 2 mau 4 3 2 1 2.00 - Impurity K 3.613 - Paracetamol.33 - Impurity B 6.633 - Impurity A 13.240 - Impurity H 30.420 - Impurity I 3.13 - Impurity J 0 0 10 1 20 2 30 3 40 4 Minutes Figure 2 Example chromatogram of paracetamol and impurities with the Agilent 1120 Compact LC. 4

As shown in Figures 1, 2, and 3, the resolution and relative retention meet the EP requirement for both paracetamol and impurity F. The results of the control sample, shown in Table 2, fulfill all criteria. The sensitivity was given for all peaks and resolution was achieved for all relevant compounds of the mixture. Not only for impurity K and paracetamol, but for all other relevant peaks the resolution was greater than 4, showing very good selectivity for the ZORBAX StableBond RP8 material and the good performance of the system. The data for peak symmetry (not shown) for all peaks ranged from 0.88 1.02. mau 17. 1 12. 10 7. 2. 0 3.664 - Paracetamol 2.09 - Impurity K.446 - Impurity B 6.762 - Impurity A 13.617 - Impurity H 10 1 20 2 30 3 40 minutes Figure 3 Chromatogram with all relevant impurities. 31.277 - Impurity I 32.721 - Impurity F 36.689 - Impurity J Retention time (minutes) Resolution Agilent 1200 Agilent 1120 Agilent 1200 Agilent 1120 Compound Series LC system Compact LC Series LC system Compact LC Impurity K 2.498 2.07 Paracetamol 3.69 3.620 7.19 7.03 Impurity B.44.33 9.22 9.04 Impurity A 6.792 6.633.7.1 Impurity H 13.716 13.240 19.2 18.3 Impurity I 31.62 30.387 26.2 24.89 Impurity J 37.066 3.480.47.03 Table 2 Results for control sample: retention times and resolution.

The criterion for the signal-to-noise ratio for impurity J was fulfilled for both systems. With the Agilent 1200 Series system the average value was found to be 61.4 and with the Agilent 1120 Compact LC system, it was 63.9 for the reference solution. Table 3 shows the areas and retention time precision results of the main compound and the impurities of the suitability sample. The reliability and precision of the Agilent 1200 Series and the Agilent 1120 Compact LC system were proven. For all components the criteria for precision of retention times and areas were fulfilled, so that both systems can be used for QC methods. Agilent 1200 Series LC system Agilent 1120 Compact LC Retention RSD RT RSD Area Retention RSD RT RSD Area Compound time (min) n = 2 n = 10 time (min) n = 2 n = 10 Impurity K 2.498 0.127 0.66 2.07 0.177 0.690 Paracetamol 3.69 0.048 0.4 3.620 0.111 0.342 Impurity B.44 0.061 0.263.33 0.13 0.32 Impurity A 6.792 0.14 0.21 6.633 0.206 0.348 Impurity H 13.716 0.22 0.831 13.240 0.311 0.636 Impurity I 31.62 0.278 0.99 30.387 0.371 0.681 Impurity J 37.066 0.324 0.404 3.480 0.386 0.28 Table 3 Suitability sample: precision of retention times and areas. Comparing the results for the suitability sample, it was found that the precision of retention times was nearly the same. Only few deviations were observed. The same was seen with the precision of areas. Both systems provide for the same injector and detector performance, independent of the hardware. 6

Conclusion The Agilent 1120 Compact LC is designed for users who need the highest reliability, ease of use, and lowest cost of ownership for standard LC methodology in a QA/QC environment in medium to small companies. The comparison with the standard 1200 Series LC system shows very similar results for these applications. To prove precise results from a system optimized for everyday productivity and to fulfill regulatory compliance, the experiments in this Application Note included determination of precision of areas and retention times, as well as chromatographic parameters like resolution and signal-to-noise ratios. As shown in Table 2, the resolution of all peaks was found to be greater than 4.0, with a signal-to-noise ratio of more than 60 (> 0 required) with both systems for the relevant compound. The calculated signal-to-noise ratios prove the sensitivity of the system and show that the instrument can be operated according to the requirements in a quality control environment. due to reduced costs per system and improved simplicity of use. In addition to the instrument capabilities, the new version of the EZChrom Elite Compact software allows full control of the Agilent 1120 Compact LC, with a wide range of features for data analysis and reporting of the results. The high performance of the new pump is strongly demonstrated by the good results for the precision of the retention times. Also the high S/N ratios (> 0 for the relevant components with the reference sample) are a result of the low pump pulsation. The high precision of the injector is shown with very similar results for area precision compared to the standard LC system. The results for peak symmetry show the good selectivity and performance of Agilent column technology as well as the very good flow design of the LC systems, with no band broadening or peak distortion. Reference 1. European Pharmacopoeia.0, 2184 The results of Table 3 show that all criteria for the precision of the determination (areas and retention times) are fulfilled. All criteria related to EP and USP requirements are fulfilled, and the determination of paracetamol and its impurities can also be done with the reliable Agilent 1120 Compact LC system. All results explicitly show the applicability of the 1120 Compact LC system for drug testing in QA/QC departments 7

www.agilent.com/chem/1200 Agilent Technologies, Inc., 2010 June 1, 2010 Publication Number 990-3739EN