Determination of Pesticide Residue in Vegetables Using the AutoMate-Q40. Application Note. Abstract. Introduction

Similar documents
Determination of Pesticide Residue in Apple Juice Using the AutoMate-Q40

Q40. This automated platform will streamline the two part QuEChERS method from the liquid extraction through the cleanup.

Tyler Trent, Applications Sales Specialist; Teledyne Tekmar Page 1

Application Note. Abstract. Introduction. Experimental Instrument Conditions. Evaluation of Prohibited Dyes in Food : By An Automated Extraction

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

Validation Report 19

Multi-Residue Pesticide Analysis in Ginseng Powder: Optimized Cleanup After QuEChERS Extraction for UPLC-MS/MS And GC-MS/MS Analysis

Analysis of the Massachusetts Cannabis Pesticides List Using the SCIEX QTRAP System

MultiQuant Software Version 3.0

Validation Report 16

Extraction and Analysis of Neonicotinoid Pesticides using QuEChERS Approach

Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety

Pesticide Residues in Produce Analyzed by Targeted MRM HR Full- Scan Acquisition and Processing

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

Multiresidue Pesticide Analysis with the Agilent Intuvo 9000 GC and Agilent 7000 Series Mass Spectrometer

Multi-Residue Pesticide Methodologies. Frans Schoutsen

Determination of chemical contaminants in marine fish by GCMS/MS using QuEChERS as an extraction method

Extraction and Dispersive Kits User Guide

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Product Descriptions and Offerings

Analysis of Pesticide Residues in Lettuce Using a Modified QuEChERS Extraction Technique and Single Quadrupole GC/MS

Puzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note

ANALYSIS OF MYCOTOXINS IN FOOD MATRICES

API 3200 LC/MS/MS system

ACCURACY THE FIRST TIME. Reliable testing with performance, productivity and value combined AB SCIEX 3200MD SERIES MASS SPECTROMETERS

Sample Matrix Influence on GC/MS/MS Multiresidue Pesticide Analysis

Improving the Detection Limits for Highly Basic Neuropeptides Using CESI-MS

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit

Product Descriptions and Offerings

A Sub-picogram Quantification Method for Desmopressin in Plasma using the AB SCIEX Triple Quad 6500 System

A Sub-picogram Quantification Method for Desmopressin in Plasma using the SCIEX Triple Quad 6500 System

Application Note: Multi-Residue Pesticides in Fruit and Vegetables (9/16/08)

Improving Chromatographic Performance of Underivatised Anionic Polar Pesticides in Food to Overcome Renowned Analytical Challenges

High Levels of Sensitivity and Robustness for Complex and Demanding Matrices SCIEX TRIPLE QUAD 5500 SYSTEM

MultiQuant Software 2.0 with the SignalFinder Algorithm

Above and beyond the extraordinary

EPA Method 540: Selected Organic Contaminants Using Agilent Plexa Cartridges and the Agilent 6460 Triple Quadrupole LC/MS

Application Note. Abstract. Authors. Introduction. Environmental

Validation Data for the Analysis of Chlorotalonil in Leek Using Mini-Luke Method Followed by GC-QqQ-MS/MS

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment QTRAP 5500

Development and evaluation of Nano-ESI coupled to a triple quadrupole mass spectrometer for quantitative proteomics research

Analysis of Multi-Residue Pesticides in Rice by LC/MS/MS

Additional guidance on: TNsG on Data Requirements, Part A, Chapter 2, Point 4. Analytical Methods for Detection and Identification.

On-line SPE-LC/MS/MS to Detect Organonitrogen and Triazine Pesticides at 10ng/L in Drinking Water

OptiFlow Quant Solution for High-Sensitivity Quantitation

Evaluation by Competent Authorities

SCIEX OS Software One Touch Productivity

Quantitation of cyanotoxins in drinking water according to EPA 544 guidelines

Agilent Sample Preparation Portfolio ACCURATE, REPRODUCIBLE RESULTS RIGHT FROM THE START

ACCURACY THE FIRST TIME. Bring Your Esoteric Assays In-House Routinely SCIEX DIAGNOSTICS MASS SPECTROMETERS

Supporting Information

LC/MS/MS Determination of PFOS and PFOA in Water and Soil Matrices

An analytical instrument manufacturer s perspective;

Thermo Scientific VetDrugs Explorer Collection

Ultra-Sensitive Quantification of Trastuzumab Emtansine in Mouse Plasma using Trap-Elute MicroLC MS Method

The Agilent Metabolomics Dynamic MRM Database and Method

Multiresidue Screening of Agricultural Chemicals in a Food Matrix using Varian SPE and Triple Quadrupole LC-MS/MS

Improving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS

Residual highly polar pesticides in beer Jan Stenzler Application specialist LCMS Product group LCMS Shimadzu Deutschland GmbH

Key Words Pesticides analysis, food safety, TSQ Endura, TraceFinder, MRL, tsrm, residue analysis

- DisQuE Dispersive Sample Preparation

NOTICE OF INTENDED DECISION TO ENTER INTO A SINGLE SOURCE CONTRACT (PUR 7778)

Universal Solution for Monoclonal Antibody Quantification in Biological Fluids Using Trap-Elute MicroLC-MS Method

World-leading LC/MS/MS technology for quantitation and identification API LC/MS/MS System

Jonathan R. Beck and Charles T. Yang; Thermo Fisher Scientific, San Jose, CA

Current and future trends in Pesticide Residue analysis. Jim Garvey

Quantitative analysis of illegal dyes in eggs using LC/MS/MS

EFFECTIVE SPE STRATEGIES FOR LC/MS DETERMINATION OF SUDAN DYES IN CHILI PRODUCTS

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

[ VION IMS QTOF ] BEYOND RESOLUTION

Analysis of Pesticide Residues and Mycotoxins in Cannabis using QuEChERS Extraction, ChloroFiltr dspe Cleanup and LC-MS/MS Detection

Food and Environmental Analysis. A Quicker. and Easier. Sample Preparation Choice.

Determination of Multiclass Pesticides in Dry Herbs Using GC-ECD

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

Liquid Chromatograph Liquid Chromatograph Mass Spectrometer. CL Series. for In Vitro Diagnostic Use

Analysis of Trace Organic Contaminants in Water by Direct Injection Using Agilent 6490 LC/MS/MS with Pos/Neg Switching

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

Pesticide Analysis in Drinking Water with Disk Extraction and Large Volume Injection

Application Note. Abstract. Authors. Environmental

Application Note. Abstract. Authors. Food Safety

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

Increased Throughput in the Determination of PPCPs in Water Using Optimized MS Cycle Times in a High Sensitivity UHPLC-Triple Quadrupole System

The LC-MS/MS Workhorse. SCIEX 4500 Series Mass Spectrometers

Methods for Increased Sample Throughput with Dirty Samples

IMPORTANCE OF CELL CULTURE MEDIA TO THE BIOPHARMACEUTICAL INDUSTRY

Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental

Multiplexing Two Different Food Residue Methods using HILIC and Reversed Phase Chromatography in the Same LC-MS/MS Run

Extraction of Vitamin B7 (Biotin) from Serum Using EVOLUTE

AB SCIEX 4500 SERIES MASS SPECTROMETERS. The new workhorse for LC/MS/MS AB SCIEX 4500 SERIES MASS SPECTROMETERS

Mycotoxins in Food and Feed

Automated Sample Preparation for the Monitoring of Pharmaceutical and Illicit Drugs by LC-MS/MS

The Agilent StreamSelect LC/MS Solution: Increasing the Throughput of a Triple Quadrupole Mass Spectrometer

APPLICATION NOTE. Abstract. Introduction

Implement High Quality, Routine GC-MS/MS Multi-Residue Pesticides Analysis with Ease Paul Silcock & Jason Cole

Tabisam Khan 1, David R. Little 1, Liyu Yang 2, Jiwen Chen 2, Parya Nouri 2, Samy Tadros 2, Patrick J. Rudewicz 2

Automation for Improving the Workflows for LC-MS/MS. Francois Espourteille, Ph.D. Manager, Applications

Transcription:

Application Note Abstract Determination of Pesticide Residue in Vegetables Using the AutoMate-Q40 Page 1 QuEChERS is a Quick-Easy-Cheap-Effective-Rugged-Safe extraction method that has been developed for the determination of pesticide residues in agricultural commodities. While the original unbuffered method was developed for plant matrices, since 2003, two additional buffered methods were created and adapted to many additional matrices such as vegetables. The rise in popularity of the QuEChERS technique and the increase in sample testing have driven the need for automation for this extraction technique. The AutoMate-Q40 streamlines the two part QuEChERS method from the solid/liquid extraction to the dspe cleanup step. The aim of this project is to demonstrate the performance and versatility of the Automate-Q40. An LC- MS/MS was used to determine pesticide residues in vegetables, particularly in tomatoes and green beans. Pesticide residues were extracted from the vegetables using the AutoMate-Q40. Quantification was based on matrix-matched calibration curves with the use of internal standard to ensure method accuracy (Document N Sanco/12495/2011). QC samples were evaluated at levels of 20.0, 40.0 and 80.0 ng/g to ensure precision and accuracy of the AutoMate-Q40. The limit of quantification (LOQ) of this method was determined to be 10.0 ng/g. Introduction Pesticides residue laboratories are required to undertake analyses of an ever increasing number of samples. The analyses typically involve use of multi-residues methods (both GC-MS and LC-MS) to test for over 500 pesticides residues. Due to its ease of use and proven robustness, the QuEChERS extraction has become the method of choice for pesticide multi-residue analyses in wide range of matrices. This study used laboratory spiked samples to validate the performance of the QuEChERS extraction on a fully automated system, for pesticides amenable to analysis by LC-MS/MS. Even though the QuEChERS is a simplified extraction technique, it still requires numerous manual steps including the addition of solvent, extraction salts, centrifugation, shaking, decanting and performing the dspe cleanup 1-3. Teledyne Tekmar has developed the AutoMate-Q40 to automate the QuEChERS extraction method, allowing scientist additional time to focus on other laboratory requirements. This automated platform streamlines the two part QuEChERS method from the homogenate to the final extract. The AutoMate-Q40 will be used to perform an automated QuEChERS extraction of pesticides in green beans and tomatoes. Quantification is based on matrix-matched calibration curves with the use of an internal standard to ensure method accuracy. QC samples were analyzed at known concentrations of 20.0, 40.0, and 80.0 ng/g, precision and accuracy studies were performed to validate the AutoMate-Q40.

Instrument Conditions Page 2 Extraction Parameters Green beans and tomato samples were prepared following AOAC Official Method 2007.01 Pesticide Residues in Foods by Acetonitrile Extraction and Partitioning with Magnesium Sulfate 1. The fresh samples were stored at room temperature. Once homogenize, the samples were stored in the refrigerator. Figure 1 shows the sample preparation and extraction steps that are needed to extract the pesticide residues from vegetables. For this analysis, the AutoMate-Q40 used AOAC QuEChERS buffered extraction salts (Anhydrous MgSO4 and NaOAc). The AutoMate-Q40 also used the AOAC version of MgSO4, and PSA for the dspe cleanup step. (1200mg MgSO4, 400mg PSA) Figure 1 AutoMate-Q40 Extraction Parameters for Green Beans and Tomato Instrumentation and Analytical Conditions A Shimadzu Nexera LC interfaced to an AB Sciex 4500 QTrap, triple-quad mass spectrometer (LC- MS/MS) was used to separate and detect the pesticide residues. A Phenomenex Synergi 4u Fusion RP 80Å column was used to separate the pesticides of interest. Table I and Table II documents the critical LC-MS/MS analysis parameters for chromatographic separation and optimal analyte transitions. Figure 2 shows the scheduled MRM chromatogram for a sample spiked at the 400.0 ng/g level.

Page 3 Table I Critical LC-MS/MS SRM Transitions and Parameters for AB Sciex 4500 QTrap Compounds RT (min) Curtain Gas (CUR) 20 Ion Spray Voltage (IS) 5500 Temperature (TEM) 350 Collision Gas (CAD) Medium Analyte Transitions Precursor Ion (m/z) Quantization product Ion (m/z) DP(V) CE(V) CXP(V) Atrazine 1 6.9 215.97 173.9 11 25 14 Atrazine 2 6.9 215.97 103.9 11 39 14 Azoxystrobin 1 7.6 403.88 372.0 41 21 10 Azoxystrobin 2 7.6 403.88 343.9 41 35 26 Bitertanol 1 8.7 337.95 268.8 16 13 22 Bitertanol 2 8.7 337.95 99.00 16 19 10 Boscalid 1 7.7 344.80 306.7 76 25 10 Boscalid 2 7.7 344.80 139.9 76 23 14 Carbaryl 1 6.3 201.90 144.9 11 13 22 Carbaryl 2 6.3 201.97 126.9 11 39 10 Chlorpyrifos 1 9.6 351.95 96.90 51 43 10 Chlorpyrifos 2 9.6 351.95 199.6 51 27 18 Clofentezine 1 8.8 302.78 137.8 46 21 12 Clofentezine 2 8.8 302.78 101.9 46 51 14 Cyprodinil 1 8.4 225.94 92.9 111 47 8 Cyprodinil 2 8.4 225.94 76.9 111 65 8 Difenoconazole 1 8.9 405.78 250.8 46 33 18 Difenoconazole 2 8.9 405.78 187.9 46 61 14 Pyaclostrobin1 8.7 387.86 193.8 46 17 18 Pyraclostrobin 2 8.7 387.86 162.8 46 33 14 Tebufenozide 1 8.4 353.02 132.9 56 25 14 Tebufenozide 2 8.4 353.02 296.9 56 11 22 TPP 1 8.7 326.91 214.7 91 35 16 TPP 2 8.7 326.91 167.7 91 47 14 Trifloxystrobin 1 9.1 408.91 185.6 56 27 18 Trifloxystrobin 2 9.1 408.91 144.7 56 61 12 Triflumazole 1 9.1 345.88 277.6 20 15 24 Triflumazole 2 9.1 345.88 72.80 20 21 6

Page 4 Table II Shimadzu Nexera LC Parameters Column Dimensions Mobile Phase Synergi 4u Fusion RP 80Å 50 X 2.00 mm A:5mm Ammonium Acetate w/0.5% Acetic in H 2 O B:5mm Ammonium Acetate w/0.5% Acetic in MeOH Time %B 0.10 5% 9.00 90% Gradient 12.00 100% 15.00 100% 15.10 20% 17.00 STOP Flow Rate (ml/min) 0.300 Column Temperature ( C) 40 Figure 2 400.0 ng/g Spike Pesticides in Tomato and Green Beans Experimental Results Automating the QuEChERS extraction, enables fast, easy, reliable and more reproducible extractions. The AutoMate-Q40 offers significant labor savings, while improving the repeatability and consistency of the sample extractions. A precision and accuracy study was performed using the AutoMate-Q40. A 6.0 µg/ml stock pesticide solution was used to fortify the vegetable samples. The AutoMate-Q40 spiked the samples with 50.0, 100.0 and 200.0 µl of the pesticide standard, to produce 20.0, 40.0 and 80.0 µg/l check samples. The AutoMate-Q40 was also used to spike 75.0 µl of the internal standard, Triphenylphosphate, (TPP) in each sample. These QC samples were then quantitated against the corresponding matrix matched calibration curve.

Page 5 Table III LC-MS/MS Values for Tomatoes Checks Samples Extracted using AutoMate-Q40 Compound Low Spike 20.0 ng/g Medium Spike 40.0 ng/g High Spike 80.0 ng/g %Recovery %RSD % Recovery %RSD % Recovery %RSD Azoxystrobin 92.2 7.3 99.8 1.7 101.2 7.4 Bitertanol 88.8 7.4 93.6 2.4 90.4 6.2 Boscalid 92.5 8.7 98.4 2.8 94.9 8.1 Carbaryl 94.8 7.8 98.7 2.1 100.6 5.5 Chlorpyrifos 90.8 7.0 91.5 2.6 91.7 6.3 Clofentezine 88.9 8.6 91.8 1.9 93.7 8.6 Cyprodinil 84.6 9.4 89.1 2.2 87.2 6.7 Difenoconazole 88.2 9.2 91.0 3.6 89.6 6.7 Pyraclostrobin 88.3 10.0 94.1 2.0 94.4 7.4 Tebufenozide 90.6 9.4 94.7 1.6 94.1 6.8 Trifloxystrobin 87.1 10.1 95.5 4.4 93.2 7.8 Triflumazole 84.5 9.5 87.9 3.3 87.0 7.6 Table IV LC-MS/MS Values for Green Bean Checks Samples Extracted using AutoMate-Q40 Compound Low Spike 20.0 ng/g Medium Spike 40.0 ng/g High Spike 80.0 ng/g %Recovery %RSD %Recovery %RSD % Recovery %RSD Atrazine 82.7 7.7 88.6 3.4 94.5 1.2 Azoxystrobin 97.5 6.1 105.3 4.1 114.1 2.0 Bitertanol 88.6 7.38 93.5 4.7 100.6 2.4 Boscalid 94.2 6.5 101.6 4.7 109.4 2.2 Carbaryl 84.8 7.2 89.8 4.4 98.5 1.7 Chlorpyrifos 89.3 6.3 92.8 3.1 98.5 3.4 Clofentezine 92.3 6.5 98.2 5.8 106.4 1.2 Cyprodinil 90.5 6.4 94.7 4.0 101.7 2.3 Difenoconazole 89.0 6.7 92.8 4.2 99.8 1.6 Pyraclostrobin 96.4 4.7 102.7 4.1 110.8 2.0 Tebufenozide 96.8 5.2 107.5 5.1 118.0 1.6 Trifloxystrobin 96.5 5.5 101.2 4.0 110.7 2.2 Triflumazole 90.4 4.8 94.0 3.6 100.8 1.1

Page 6 The data from tables III and Table IV documents the AutoMate-Q40 ability to extract pesticide residues from vegetable samples with recoveries ranging from 82.8% to 118.1%. These spike recoveries fall well within the recommended mean values in Document N Sanco/12495/2011 5 which states the mean recoveries must fall within 70% to 120% and a RSD <20%. The AutoMate-Q40, also, demonstrated great precision ranging from 1.7% to 10.1%RSD for the spiked QC samples. Conclusion The AutoMate-Q40 successfully processes vegetable samples for pesticide residue utilizing the QuEChERS method. By automating the liquid handling, addition of salt/buffers, sample mixing, pipetting, and liquid level sensing using patent pending VialVision. Today's scientists are freed from laborintensive extraction methods and exposure to unhealthy chemicals. This creates an extraction process that is faster, more reliable, and easier than the traditional manual based procedure. As seen above in Tables III and IV, excellent precision and accuracy can be achieved without consuming valuable analysts' time. Additionally, the combined pesticide spike recoveries of 95.0%, at an average RSD of 5.17%, exceed the requirement outlined in The Document N Sanco/12495/2011 5, validating the performance of the AutoMate-Q40 to perform the QuEChERS pesticide extraction method for vegetables. References 1. European Committee for Standardization/Technical Committee CEN/TC275 (2008), Foods of plant origin: Determination of pesticide residues using GC-MS and/or LC-MS/MS following acetonitrile extraction/ partitioning and cleanup by dispersive SPE QuEChERS-method. 2. AOCA Official Method 2007.07 Pesticide Residues in Food by Acetonitrile Extraction and Partitioning with Magnesium Sulfate. Gas Chromatography/Mass Spectrometry and Liquid Chromatography/Tandem Mass Spectrometry, First Action 2007 3. Anastassiades M.; QuEChERS a mini-multiresidue method for the analysis of pesticide residues in lowfat products 4.Mastoska, K.; Dorweiler K.; Leotay S.; Pesticide Multiresidue Analysis in Cereal Grains using Modified Quechers Method Combined with Automated direct Sample Introduction GC-TOFMS and UHPLC-MS/MS Techniques 5. Method Validation and Quality Control Procedure for Pesticide Residues Analysis in Food and Feed (Document N SANCO/12495/2011)