Product Guide Specification

Similar documents
PRODUCT GUIDE SPECIFICATION

Product Guide Specification

DL-200. Specifications

Product Guide Specification

Product Guide Specification

TECHNICAL INFORMATION

DURAMAX Building Products a division of US Polymers Inc. July S Vail Ave Montebello, CA., Toll Free Phone Fax Website

SSL-175. Specifications

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

Product Guide Specification

FORTIFIED Home High Wind. Bronze New Roof Requirements

SECTION METAL ROOF & WALL PANELS

STONE COATED METAL ROOF SHINGLE

SECTION METAL ROOF AND SOFFIT PANELS

SECTION COPPER STANDING SEAM ROOFING

Product Guide Specification

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

SECTION TURBINE VENTILATORS

SECTION ASPHALT SHINGLE ROOFING SYSTEMS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".

CS-100 Guide Specifications

DIVISION 7 THERMAL & MOISTURE PROTECTION

SRP-AirOutshield ROOF Issued:

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR

ZARA & ASSOCIATES, INC. Peter L. Zara 8435 Sunrise Lake Blvd -# Sunrise, Florida Phone

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOF PANELS REPORT HOLDER: ONDULINE NORTH AMERICA, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF TILES REPORT HOLDER: GERARD ROOFING TECHNOLOGIES EVALUATION SUBJECT:

Distributed by: BEST MATERIALS LLC Ph: , Fax:

Product Guide Specification

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

Product Guide Specification

Product Guide Specification

Product Guide Specification

Product Guide Specification

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS

Section STRAIGHT BARREL MISSION ROOFING TILE PART 1 - GENERAL 1.1 SUMMARY

UL Evaluation Report UL ER Issued: May 31, Revised: June 6, UL Category Code: ULEZ. CSI MasterFormat

Installation Guide. Titan Slate. Rev102606

Product Guide Specification

Product Guide Specification

Specifier Note: Coordinate the following Article with Section Protecting Installed Construction.

Gerard Shingle, Granite Ridge, and Guardian Shingle

A. Provide all labor, equipment, and materials fabricate and install the following. 2. Counterflashings over bituminous base flashing.

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

APPLICABLE UNDER SECTIONS: SOLAR ENERGY HEATING EQUIPMENT SOLAR HEATING COLLECTORS METAL WALL PANELS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Product Guide Specification

SECTION METAL ROOF & WALL PANELS

SPECIFICATION GUIDELINE

Product Guide Specification

SECTION / METAL FRAMED SKYLIGHTS

Specifier Note: Revise paragraph below to suit project requirements. Add section numbers per CSI MasterFormat and specifier s practice.

Guide Specification SECTION VEGETATED PROTECTED MEMBRANE ROOFING DRAINAGE MATS

Architectural Roof Products Guide Specifications

DIVISION 7 THERMAL AND MOISTURE PROTECTION

Product Guide Specification

Product Guide Specification

SECTION CONCRETE ROOF TILE

SECTION METAL ROOF PANELS

ENVIROSHINGLE Systems LP Composite Shingle Roofing Section Master Guide Specification Page 1 January 2018

Architectural Roof and Wall Products Guide Specifications

Product Guide Specification

SPECIFICATION GUIDELINE

M.C.A. Superior Clay Roof Tile

SECTION BATTEN SEAM COPPER ROOFING

ENVIROSLATE Systems LP Composite Slate Roofing Section Master Guide Specification Page 1 January 2018

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

SECTION ROOF SPECIALTIES

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

238T Aluminum Standing Seam Metal Roof System (SSMRS)

ROOF ASSEMBLIES CHAPTER 9

3. Roof Expansion Joints between New Building and Existing Building.

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

EVALUATION REPORT Boral Roofing /MonierLifetile 7575 Irvine Center Drive Suite 100 Irvine, CA

Product Guide Specification

SECTION STANDING SEAM METAL ROOFING

SECTION CONCRETE TILE ROOFING. A. American Society for Testing and Materials (ASTM):

Architectural Roof Products Guide Specifications

Drexel Metals Inc. DMC 5V 26 Gauge min. Face-Fastening Metal Roof System over Plywood

EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659

University of New Hampshire Scholars' Repository

Architectural Wall Products Guide Specifications

SECTION ROOF ACCESSORIES

Roofing City of Owatonna BUILDING DEPARTMENT

SECTION CLAY BARREL TILE ROOFING Removals Flashing and Sheet Metal.

CBUCK Engineering. Evaluation Report MI Off Ridge Vent Ridge Vent Assembly

ROOF ASSEMBLIES CHAPTER 9

Product Guide Specification

Span-Lok hp, Curved Span-Lok, & SpanSeam Guide Specifications

SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.

Architectural Roof and Wall Products Guide Specifications

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Tuscaloosa Police Station

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

Transcription:

Millennium Tiles, LLC March 2011 550 East Centralia Street Elkhron, WI 53121 Phone (262) 723-7778 Fax (262) 723-7629 Website www.millenniumtiles.com E-mail info@millenniumtiles.com Product Guide Specification Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described in The Project Resource Manual CSI Manual of Practice. The section must be carefully reviewed and edited by the Architect to meet the requirements of the project and local building code. Coordinate this section with other specification sections and the Drawings. Delete all Specifier Notes when editing this section. Section numbers and titles are from MasterFormat 1995 Edition, with numbers and titles from MasterFormat 2004 Edition in parentheses. Delete version not required. SECTION 07320 (07 32 19) ZALMAG STEEL ROOF/WALL TILES Specifier Notes: This section covers Millennium Tiles, LLC ZALMAG STEEL roof/wall tiles. Consult Millennium Tiles for assistance in editing this section for the specific application. PART 1 GENERAL 1.1 SECTION INCLUDES A. ZALMAG STEEL tiles. 1.2 RELATED SECTIONS Specifier Notes: Edit the following list of related sections as required for the project. List other sections with work directly related to this section. A. Section 07600 (07 60 00) Flashing and Sheet Metal. B. Section 07700 (07 70 00) Roof Specialties and Accessories (Roof and Wall Specialties and Accessories). C. Section 07920 (07 92 00) Joint Sealants. ZALMAG Roof Tiles 07320 (07 32 19) - 1

1.3 REFERENCES Specifier Notes: List standards referenced in this section, complete with designations and titles. This article does not require compliance with standards, but is merely a listing of those used. A. ASTM A 1046/A 1046M 1Standard Specification for Steel Sheet, Zinc-Aluminum-Magnesium Alloy-Coated by the Hot-Dip Process. B. ASTM D 226 2Standard Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing. C. ASTM E 8 3Standard Test Methods for Tension Testing of Metallic Materials. 1.4 SUBMITTALS A. Comply with Section 01330 (01 33 00) Submittal Procedures. B. Product Data: Submit manufacturer s product data, including surface preparation and installation instructions. C. Samples: Submit manufacturer s samples of ZALMAG steel roof/wall tiles. D. Manufacturer s Certification: Submit manufacturer s certification that materials comply with specified requirements and are suitable for intended application. E. Warranty: Submit manufacturer s standard warranty. 1.5 DELIVERY, STORAGE, AND HANDLING A. Delivery: Deliver materials to site in manufacturer s original, unopened containers and packaging, with labels clearly identifying product name and manufacturer. B. Storage: Store materials in clean, dry area in accordance with manufacturer s instructions. C. Handling: Protect materials during handling and installation to prevent damage. 1.6 WARRANTY A. Warranty Period: 40 years. PART 2 PRODUCTS 2.1 MANUFACTURER A. Millennium Tiles, LLC, 550 East Centralia Street, Elkhorn, WI 53121 Phone 262.723.7778 Fax 262.723.7629 Website www.millenniumtiles.com E-mail info@millenniumtiles.com ZALMAG Roof Tiles 07320 (07 32 19) - 2

2.2 ZALMAG STEEL ROOF/WALL TILES A. ZALMAG STEEL Roof/Wall Tiles: 1. Description: Individual roof/wall tiles with 4-sided interlocking design, self-aligning tab, and concealed nailing strip with 2 holes. 2. Material: ZALMAG STEEL. a. Coating consists of Zinc, Aluminum, Magnesium and Silicon. 3. Size: a. Large Tiles: 15 inches by 9-5/8 inches. b. Accent Tiles: 7-3/4 inches by 9-1/4 inches. 4. Size Exposed to Weather: a. Large Tiles: 14-1/2 inches by 8-3/8 inches. b. Accent Tiles: 7-1/4 inches by 8-1/8 inches. 5. Weight: a. Large Tiles: 1.05 lbs./sq. ft. b. Accent Tiles: 1.10 lbs./sq. ft. 6. Thickness: 0.017 +/-.002 (26 gauge) 7. Density: 0.284 lbs./cu. in. 8. Temper: Hot Rolled 9. Tensile Strength: 50,000 psi. 10. Yield Strength: 27,600 psi. 11. Elongation: 22% 12. Rockwell Hardness: B 58 13. Thermal Conductivity BTU-in/hr-ft²-ºF: 360BTU-in/hr-ft²- F 14. Ratings: a. Wind: 110 mph. b. Fire: Class A, B, and C. 15. ICBO Approval Number: 4995. Specifier Notes: Specify Size & Type, select one. 16. Tile Size & Type a. Accent tile b. Large tile without shadow cup c. Large tile with shadow cup (indentation) 2.3 ACCESSORIES A. Trim and Flashing: Same material and gauge as ZALMAG tiles. Specifier Notes: Edit the follow list as required. 1. Starter strip. 2. Valley. 3. Hip and ridge cap. 4. End wall. 5. Side wall. 6. Gable end. 7. Outside corner flashing. 8. False starter. ZALMAG Roof Tiles 07320 (07 32 19) - 3

9. J-channel. 10. Continuous ridge. Specifier Notes: Roof vent should be installed for roof needing a ridge vent system. Check with the local building code for roof venting requirements. Roof vent is available from Millennium Tiles. B. Roof Vent: 1. Trim-Line Products part number 58786. 2. Rigid-roll ridge vent, 7 inches wide. C. Underlayment: ASTM D 226, No. 30 asphalt-saturated felt. D. Self-Adhered Membrane Roofing Underlayment. E. Fasteners: Galvanized steel, ring-shank roofing nails. 1. Minimum Length: a. New Construction: 1-1/4 inches. b. Existing Construction: 1-1/2 inches. F. Joint Sealants: Exterior-grade, high-temperature, silicone joint sealant. As specified in Section 07920 (07 92 00). PART 3 EXECUTION 3.1 EXAMINATION A. Examine areas to receive ZALMAG steel roof/wall tiles. B. Notify Architect of conditions that would adversely affect installation. C. Do not begin surface preparation or installation until unacceptable conditions are corrected. D. Ensure minimum roof slope of 3:12. E. Ensure roof deck is solid with a minimum thickness of: 1. Plywood: 1/2 inch. 2. Oriented Strand Board (OSB): 1/2 inch. Specifier Notes: Edit the following paragraph as required. Delete the following paragraph for new construction or if an attic inspection is not required. Determine if a total existing roof tear-off is needed. Consult Millennium Tiles for more information. F. Inspect attic to determine if existing roof deck needs to be replaced. 3.2 SURFACE PREPARATION A. Prepare surfaces in accordance with manufacturer s instructions. B. Existing Roof: Remove curled and loose tiles, bumps, buckles, dirt, debris, and other items which could adversely affect smooth installation of ZALMAG steel roof/wall tiles and interlocking mechanisms that provide watertight characteristics. C. Ensure surfaces to receive ZALMAG steel roof/wall tiles are smooth and even. ZALMAG Roof Tiles 07320 (07 32 19) - 4

3.3 INSTALLATION A. Install ZALMAG steel roof/wall tiles in accordance with manufacturer s instructions. B. Due to slight surface color variation Millennium Tiles, LLC recommends installers pull tiles from Several boxes during the installation process to assure random variation. C. Install roof tiles to achieve wind resistance of 110 mph. D. Install roof/wall tiles to provide watertight installation. E. Use specified fasteners at spacing in accordance with manufacturer s instructions. F. Prevent Electrolysis: 1. Prevent dissimilar metals and corrosive nonmetallic materials from coming into direct contact with ZALMAG steel materials. 2. Do not allow water to flow from dissimilar metals to ZALMAG steel materials. G. Underlayment: Install underlayment in accordance with manufacturer s instructions. H. Self-Adhered Membrane Roofing Underlayment: 1. Install self-adhered underlayment in accordance with manufacturer s instructions. 2. Install self-adhered underlayment at valleys and eaves. I. Install trim and flashing in accordance with manufacturer s instructions. J. Joint Sealants: 1. Install joint sealants as specified in Section 07920 (07 92 00). 2. Install joint sealants at overlapping flashing and exposed fastener heads. 3.4 PROTECTION A. Protect installed ZALMAG steel roof/wall tiles to ensure that, except for normal weathering, tiles will be without damage or deterioration at time of substantial completion. END OF SECTION ZALMAG Roof Tiles 07320 (07 32 19) - 5