Evaluation of Ultimate Strength of Steel- Concrete Hybrid Girder Using 80-MPa High- Strength Concrete

Similar documents
Experimental Evaluation of Fatigue Performance of Steel Grid Composite Deck Joints

Numerical Analysis of Torsional Behavior of Ultra-High Performance Fiber Reinforced Concrete

Study on structural behavior characteristics of concrete filled steel tube girder bridges

Structural Characteristics of New Composite Girder Bridge Using Rolled Steel H-Section

Parametric Analysis on the Optimal Dimensions of Steel Sleeve in Swaging Type Anchorage for CFRP Tendon

Fatigue Performance of Precast FRP-Concrete Composite Deck with Long Span

NEW COMPOSITE CONSTRUCTION OF HYBRID BEAMS COMBINING STEEL INVERTED T-SECTION AND RC FLANGE

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

Chapter 7. Finite Elements Model and Results

External Post-tensioning of Composite Bridges by a Rating Equation Considering the Increment of a Tendon Force Due to Live Loads

Behavior of RC Beams Strengthened with Externally Post-Tensioning CFRP Strips

Development of Composite Beam for Productivity

Field Load Testing of the First Vehicular Timber Bridge in Korea

Non Linear Analysis of Composite Beam Slab Junction with Shear Connectors using Ansys.16

INFLUENCE OF PRSTRESS LEVEL ON SHEAR BEHAVIOR OF SEGMENTAL CONCRETE BEAMS WITH EXTERNAL TENDONS

REVIEW ON SHEAR SLIP OF SHEAR KEYS IN BRIDGES

CHAPTER 2. Design Formulae for Bending

Crack detection in composite bridges with relative displacement sensors

Design of Double Composite Bridges using High Strength Steel

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

RESILIENT INFRASTRUCTURE June 1 4, 2016

Evaluation of the Shear Strength of Perfobond Rib Connectors in Ultra High Performance Concrete

Load capacity rating of an existing curved steel box girder bridge through field test

COMPOSITE STRUCTURES PREPARED BY : SHAMILAH

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

UHPC Connection of Precast Bridge Deck

Flexural Behaviour of Composite Girders Using FRP and Precast Ultra-High-Strength Fiber-Reinforced Concrete Slabs

Effect of Torsion on Externally Prestressed Segmental Concrete Bridge with Shear Key

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

Behavior of Concrete/Cold Formed Steel Composite Beams: Experimental Development of a Novel Structural System

SEISMIC RETROFIT OF BEAMS IN BUILDINGS FOR FLEXURE USING CONCRETE JACKETING

Behavior of Skew Reinforced and Prestressed Concrete Composite Decks. Hany Ahmed Ahmed Dahish, Ahmed Foad El-ragi and Alaa Aly El-Sayed

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Analytical Study on a Longitudinal Joints of the Slab-Type Modular Bridges Sang-Yoon Lee, Jung-Mi Lee, Hyeong-Yeol Kim, Jae-Joon Song

PERFORMANCE OF AN INNOVATIVE PRE-CAST COLD-FORMED STEEL AS COMPOSITE BEAM WITH SINGLE AND DOUBLE C- CHANNELS

An Experiment on Tension Stiffening Effects of High Strength Concrete

Composite Beams of Cold Formed Steel Section and Concrete Slab

Axial Compression Behavior of a New Type of Prefabricated Concrete Sandwich Wall Panel

Performance of Reinforced Concrete Beams with Implanted Columns

CHAPTER 1 INTRODUCTION

Encased Beam with Variable Upper Steel Flange Position

EVALUATION OF TIME-DEPENDENT BEHAVIOUR OF COMPOSITE CONCRETE SLABS WITH STEEL DECKING (AN EXPERIMENTAL STUDY)

ST7008 PRESTRESSED CONCRETE

Damage assessment of hollow core reinforced and prestressed concrete slabs subjected to blast loading

Appendix M 2010 AASHTO Bridge Committee Agenda Item

LOAD TESTS ON 2-SPAN REINFORCED CONCRETE BEAMS STRENGTHENED WITH FIBRE REINFORCED POLYMER

Steel-concrete Composite Bridges Designing with Eurocodes

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

Lap Splices in Tension Between Headed Reinforcing Bars And Hooked Reinforcing Bars of Reinforced Concrete Beam

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

OXFORD ENGINEERING COLLEGE (NAAC Accredited with B Grade) Department of Civil Engineering LIST OF QUESTIONS

Long-term Stress of Simply Supported Steel-concrete Composite Beams

SHEAR STRENGTHENING OF RC BRIDGE PIERS BY STEEL JACKETING WITH EXPANSIVE CEMENT MORTAR AS ADHESIVE

MAHALAKSHMI ENGINEERING COLLEGE

An Investigation of the Shear Design of Bolted Shear Key Joint in Partially Filled Steel Composite Decking System

Development of an Efficient Tapered Slip-Form System Applying BIM Technology

Flexural Capacity of the Concrete Beams Reinforced by Steel Truss System

SEISMIC BEHAVIOR OF HYBRID SYSTEM WITH CORRUGATED STEEL SHEAR PANEL AND RC FRAME

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

In-plane testing of precast concrete wall panels with grouted sleeve

SHEAR BEHAVIOR OF RC DEEP BEAMS WITH SOLID CIRCULAR CROSS SECTION UNDER SIMPLY SUPPORTED CONDITION AND ANTI-SYMMETRIC MOMENT

Residual strength of Y-type perfobond rib shear connectors to cyclic load on highway bridge

TEST AND ANALYSIS OF A SHORT-SPAN RAILWAY BRIDGE

Hybrid-steel concrete connections under reversed cyclic loadings

2.0 REVIEW OF LITERATURE. In the last few years, the use of fiber-reinforced plastic (FRP) rebars to replace steel

Development of a New Type of Earthquake Energy-absorption Device

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

GATE SOLVED PAPER - CE

SHEAR AND BUCKLING STRENGTHENING OF STEEL BRIDGE GIRDER USING SMALL-DIAMETER CFRP STRANDS

CHAPTER 4 STRENGTH AND STIFFNESS PREDICTIONS OF COMPOSITE SLABS BY FINITE ELEMENT MODEL

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

Strength of Non-Prismatic Composite Self-Compacting Concrete Steel Girders

STRUCTURAL PERFORMANCE OF STEEL-CONCRETE-STEEL SANDWICH COMPOSITE BEAMS WITH CHANNEL STEEL CONNECTORS

Nonlinear Redundancy Analysis of Truss Bridges

STRUCTURAL CHARACTERISTICS OF CONCRETE-FILLED GLASS FIBER REINFORCED COMPOSITE PILES. Abstract

Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating

DESIGN OF PC BEAM-COLUMN JOINT APPLIED X-BRACED BARS IN THE SEGMENTED STRUCTURAL SYSTEM

BUCKLING ANALYSIS OF PULTRUDED GFRP HOLLOW BOX BEAM

Parametric Study of Continuous Concrete Beam Prestressed with External Tendon

EXPERIMENTAL RESEARCH ON THE MECHANICAL PROPERTIES OF SHEAR CONNECTORS FOR COMPOSITE BEAM BRIDGE

Initial Tests of Kevlar Prestressed Timber Beams

Pile to Slab Bridge Connections

ABC-UTC. Research Progress Report (Feasibility Study) Title: Alternative ABC Connections Utilizing UHPC. March, 2017

STRUCTURAL HEALTH MONITORING OF THE COMPOSITE PLATE GIRDER IN A CANTILEVERED BUILDING

Nonlinear Finite Element Analysis of Composite Cantilever Beam with External Prestressing

Practical Methods for the Analysis of Differential Strain Effects

GFRP REINFORCED GFRC FOR THIN PERMANENT FORMWORK APPLICATIONS

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 1, 2012

Southeast University, Nanjing, Jiangsu , China. *Corresponding author

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

LOAD-BEARING PRECAST CONCRETE SANDWICH WALL PANELS WITH BASALT-FRP REINFORCEMENT AND TIES

THE ANALYTICAL STUDY OF STRENGTHENING THE HORIZONTALLY CURVED STEEL BEAM WITH CFRP LAMINATES

Effect of Loading Level and Span Length on Critical Buckling Load

Development of New PSC Box Girder Bridge with Concrete-filled FRP Struts

PERFORMANCE EVALUATION ON CORE WIRE OF SMART STRAND

FRP STRENGTHENING OF 60 YEAR OLD PRE-STRESSED CONCRETE BRIDGE DECK UNITS

Cyclic Loading Tests Of Steel Dampers Utilizing Flexure-Analogy of Deformation

Transcription:

ISSN: 235-328 Evaluation of Ultimate Strength of Steel- Concrete Hybrid Girder Using 8-MPa High- Strength Concrete HeeBeom Park, Jae-Yoon Kang *, Jong Sup Park, Woo Tai Jung PhD, Researcher, Department of Infrastructure Safety Research, Korea Institute of Civil Engineering and Building Technology, Goyang, Gyeonggi, Rep. of Korea PhD, Research Fellow, Department of Infrastructure Safety Research, Korea Institute of Civil Engineering and Building Technology, Goyang, Gyeonggi, Rep. of Korea PhD, Research Fellow, Department of Infrastructure Safety Research, Korea Institute of Civil Engineering and Building Technology, Goyang, Gyeonggi, Rep. of Korea PhD, Senior Researcher, Department of Infrastructure Safety Research, Korea Institute of Civil Engineering and Building Technology, Goyang, Gyeonggi, Rep. of Korea ABSTRACT: The typical composite girder bridge combines the I-shape steel girder and the concrete slab by means shear connectors. In this sectional configuration, the neutral axis is located in the slender steel section which makes the structure vulnerable to local buckling or lateral-torsional buckling when subject to flexure. However, this situation results in the ultimate limit state of the composite girder being determined by the ultimate strength of the steel girder. Accordingly, the steel-concrete (SC) hybrid girder was developed to solve this problem. The SC hybrid girder presents casing blocks made of concrete with compressive strength higher than 8 MPa between the steel girder and the concrete slab and is designed to let the neutral axis be located near the interface between the casing blocks and the steel girder so as to exploit efficiently each of the material properties. The present study examines the ultimate strength performance of such SC hybrid girder featured by two interfaces. To that goal, specimens exhibiting two different shear connection details were designed and fabricated and the flexural behavior was evaluated up to the ultimate limit state. The results show that the SC hybrid girder behaved elastically under the service load and satisfied the serviceability requirement for the allowable deflection. In addition, given that proper design is achieved, the SC hybrid girder secured sufficient structural stability in view of the facts that the slab failed first through compression because of the action of the rebar even under tension generating partial cracking of the casing and that the section yielded at 3.2 to 3.6 times the service load. KEYWORDS: SC hybrid girder, steel girder, concrete slab, two interfaces, shear connection I.INTRODUCTION The composite girder of the bridge is composed of the I-shape steel girder resisting to tension and the concrete slab resisting to compression. These two members are typically connected by means of shear connectors. In the so-formed section, all the parts below the compression flange and below the web neighbouring the compression flange are in the tensile zone which reduces significantly the risk of local buckling and can be regarded as a compact section. However, the adoption of the slender steel girder makes the structure vulnerable to local buckling or lateral-torsional buckling. This situation results in the ultimate state of the composite girder being determined by the ultimate strength of the steel girder. Especially, there are numerous overseas examples of accidents caused by the lateral-torsional buckling during the fabrication of the slab before composition. The steel-concrete (SC) hybrid girder shown in Fig. 1 was developed to solve the problem encountered in the composite girder. In the SC hybrid girder, the I-shape steel girder is first composed at its upper chord to concrete with compressive strength of 6-1 MPa to improve the ultimate strength of the composite girder and its resistance to buckling. This structure achieves efficient and rational arrangement of the materials by allowing concrete to resist to compression in the upper chord and steel to resist to tension in the lower chord. Moreover, the confinement of the slender steel section by the concrete in the compression zone complements the structural vulnerability to local buckling Copyright to IJARSET www.ijarset.com 6297

ISSN: 235-328 or lateral-torsional buckling in the compression zone before the composition with the slab. The position of the centroid in the upper part of the I-shape steel girder increases the buckling stability and can minimize the cross-section of the top flange with relatively less material need for the member. High Strength Concrete f ck =6~1N/mm 2 Casing Joint Expand Mortar Fig.1: Composite of steel-concrete hybrid girder The strengthening of the compression flange of the SC hybrid girder by high-strength (6-1 MPa) concrete brings relatively better buckling stability and higher torsional resistance compared to the conventional composite girder. For similar centroid, the SC hybrid girder experiences only minimal compressive stress in its compression flange whereas the high-strength concrete part takes charge of large compression. In addition, the SC hybrid girder presents a torsion constant 2 times larger than that of the conventional composite girder, which makes it very resistant to torsion. However, the performance of the SC hybrid girder must be verified experimentally prior to its actual application on site. Especially, the SC hybrid girder featured by the presence of two interfaces shall secure sufficiently perfect composite behaviour until both interfaces reach their ultimate strength. Accordingly, this study evaluates the flexural behaviour of the SC hybrid girder up to the ultimate limit state on specimens designed and fabricated with two different shear connection details. II. STRUCTURE TEST A. Design of Specimens Steel Girder (open web) The specimens were designed in compliance with the Korea Bridge Design Code (limit state design). The design was conducted for the most unfavourable stress case under application of the standard truck load KL-51 on 2 traffic lines. The sections and materials were selected to satisfy the ultimate and service limit states and the shear connection was designed for fatigue including an impact factor of 15%. As shown in Fig. 2, the specimens have a total length of 18.8 m and the slab presents a width of 2 m identical to the beam spacing. This is a compact section with a total depth of 1. m including the slab in which the steel girder is 58 mm high and the casing has dimension of 6 2 mm. In the upper part, the top flange is confined by high-strength concrete that keeps the stress to a low level and its width is set to a size allowing shear connection. The thickness of the web was chosen with respect to the shear strength of the nonstrengthened web. The section of the bottom flange was decided considering that the bottom flange will be subjected to relatively large stress as well as the position of the centroid and the safety against overturning. Stiffeners are disposed at the supports to be L/3 from both ends. The stiffeners were designed for the ultimate load to prevent the occurrence of local buckling during loading. Table 1 lists the properties of the materials used in the fabrication of the specimens. The specimens shall develop sufficient stiffness and strength to let the shear connection achieve satisfactory composite behaviour until the ultimate state of the section. Even if Kang et al. [1,2] conducted various experiments to derive the shear connection condition of the SC hybrid girder, this study considers only the two different shear connection configurations shown in Fig. 3 to fabricate the specimens for the evaluation of the performance of the SC hybrid girder. In Fig. 3(a), the shear studs connect the top flange and the slab by passing through the casing. In Fig. 3(b), the shear studs connect the steel beam and the casing, and the casing and the slab are connected by means of horizontal shear reinforcement as usually done in prestressed concrete beams. For convenience, the specimen with the configuration of Fig. 3(a) is designated as SG (stud-connected) specimen and the one with the configuration of Fig. 3(b) as RG (reinforcement-connected) specimen. Copyright to IJARSET www.ijarset.com 6298

58 2 22 ISSN: 235-328 2, Deck Slab (3 MPa) (2,x22) Casing Block (8 MPa) (6x2) Top Flange(PL-45x14) Web (PL-538x14) (a) Longitudinal section Fig.2: Dimension of specimens (b) Cross-section Bottom Flange(PL-83x42) Table 1: Properties of major materials Member Material properties Remarks Concrete Slab Design strength, f dk Elastic modulus, E dk 3 MPa 27,515 MPa Normal concrete Casing Design strength, f ck 8 MPa Elastic modulus, E ck 37,49 MPa SUPER Concrete 235 MPa t > 4 mm Yield strength, f Steel I-shape sy 215 MPa 4 mm < t 1 mm SM4 girder Tensile strength, f su 4 MPa Elastic modulus, E s 25, MPa Headed Stud Horizontal Shear Rebar Headed Stud Fig.3: Shear connection of specimens B.Fabrication of Specimens The specimens were fabricated by supporting the I-shape steel girder at L/3 from both ends using H 3 3 beams and placing the casings afterwards. In order to make the girder sustain the load, the form was assembled by supporting it with falsework installed over the bottom flange before placing 8 MPa-concrete mixed in factory. Steam curing was performed after 1 day to avoid the very high hydration heat expected immediately after the placing of high-strength concrete. The completed SC hybrid girders were then transported indoor and the slab was fabricated. Here also, the fabrication was conducted to let the composite girder sustain the load of the slab. Fig. 4 depicts the fabrication process of the specimens. Copyright to IJARSET www.ijarset.com 6299

ISSN: 235-328 C.Layout of Sensors LVDTs (linear variable differential transducers) were installed at the two L/3 sections from both ends, and one LVDT and a wire displacement sensor were installed at the L/2 section to measure the deflection. Steel gages and concrete gages were attached in 3 sections. The relative slip between the steel girder and the casing and between the casing and the slab was measured by means of horizontal displacement sensors installed at both ends. Mold gages were embedded in the supports before the placing of the casing concrete. These mold gages were intended to measure the strain that would develop under the occurrence of slip between the two concretes placed at different times. By embedding the gage at half distance from the surface of the placed concrete, this strain can be obtained by reading the value of the tension generated by the flexure of the gage due to the slip. (a) Assemblage of casing form (b) Placing of 8 MPa-SUPER Concrete (c) Steam curing (d) Assemblage of slab form (e) Arrangement of slab reinforcement (f) Placing of slab concrete (g) Removal of slab form (h) Test setup Fig. 4: Fabrication of SC hybrid girder specimens Copyright to IJARSET www.ijarset.com 63

ISSN: 235-328 D.Structure Test The simply supported specimens were installed to be loaded at mid-span. A frame with width of 25 cm and length of 1.5 m was installed at the loading spot along the width of the slab to receive a 3-ton actuator at its centre. At the start of the test, loading was applied through displacement control at speed of.5 mm/s. Thereafter, from stage 3 of Table 2 and until the end of the test, loading was applied at speed of.75 mm/s. The load was increased by increment of 5 kn beyond 1,5 kn expected to be the yield load of steel. After each loading increment, the load was held and the eventual occurrence of cracking in the casing concrete, local buckling of the compression flange and relative displacement was checked. Table 2: Loading stages Stage Load (kn) Loading speed Content 1 5 Service load.5 mm/s 2 1, 3 1,5 4 1,5 1,6 Hold & check 5 1,6 1,65 Hold & check 6 1,65 1,7.75 mm/s Hold & check 7 1,7 1,75 Hold & check 8 1,75 1,8 Hold & check 9 1,8 End Failure of slab III. TEST RESULTS Both SG and RG specimens developed cracks in the bottom chord of the casing concrete after reaching the yield strain of the steel girder and tension flange. As shown in Fig. 5, both types of specimen broke through compression failure of the slab. Fig. 5: Failure patterns of SC hybrid girder Fig. 6 plots the load-deflection curves measured during the test of the specimens. It appears that the service load of the specimens is 455 kn and lies within their elastic region. The deflection measured under the service live load reached 12 mm, which represents 53% of the deflection criterion L/8 (=22.5 mm)specified in the design code. This indicates that the SC hybrid girder satisfies the serviceability requirement. The nominal strength considering the load combination suggested by the design code is 1,756 kn.both specimens develop strength larger than the theoretical ultimate strength by 8.2% to 8.8%. In Table 3, the yield load of the tension flange computed with respect to the design code is 1,44kN. The yield point cannot be distinguished clearly in Fig. 6 but the strain measurement could verify that yielding occurred around 1,63 Copyright to IJARSET www.ijarset.com 631

Load (kn) Load (kn) Load (kn) Load (kn) ISSN: 235-328 kn for SG specimen and 1,475 knfor RG specimen. These values are larger than the computed ones by 7% to 16%, and larger than the service load by 3.2 to 3.6 times. In view of these results, the SC hybrid girder appears to secure sufficient structural stability. 25 Maximum Loading 1,9kN 25 Maximum Loading 1,91kN 2 Nominal Strength(Cal.)=1,756kN 2 Nominal Strength(Cal.)=1,756kN 15 Yield Strength(Cal.)=1,44kN 15 Yield Strength(Cal.)=1,44kN 1 1 5 5 Service Load(Cal.)=455kN Service Load(Cal.)=455kN LVDT-C LVDT-C 25 5 75 1 125 15 175 25 5 75 1 125 15 175 Displacement (mm) Displacement (mm) Fig. 6: Measured load-deflection curves Table 3: Test results Item Yield load Maximum load Calculation 1,44 kn 1,756 kn Test result SG 1,63 kn (1.161) 1,9 kn (1.82) RG 1,475 kn (1.51) 1,91 kn (1.88) Fig. 7(a) presents the strain distribution of SG specimen according to the increase of the load. The specimen starts to behave linearly below the service load and experiences steep deformation beyond 1,47µε, the yield strain of the tension flange. The load at that time reaches 1,63 kn.it was verified that the centroid was located in the top flange and moved upward after the yielding of the tension flange. Cracking occurred in the lower chord of the casing around 1,78 kn.the test was interrupted when the strain at the lower chord of the slab reached the ultimate strain. Fig. 7(b) presents the strain distribution of RG specimen according to the increase of the load and resembles that of the SG specimen. The specimen appears to develop linear behaviour even at the service load of 455 kn and the deformation experiences steep increase after the yield strain of the tension flange at 1,475 kn.the centroid was first located in the top flange and started to move gradually toward the tensile side after the yielding of the tension flange. Cracking occurred in the lower chord of the casing around 1,787kN. The test was interrupted when the slab reached the ultimate strain. 25 Maximum Loading 1,9kN 25 Maximum Loading 1,91kN 2 2 15 15 1 1 5 5 UF WB LF UF WB LF CC RC RD CC RC RD -45-3 -15 15 3 45-45 -3-15 15 3 45 Fig. 7: Load-strain curves at center of section Copyright to IJARSET www.ijarset.com 632

Distance from top flange soffit (mm) Distance from top flange soffit (mm) ISSN: 235-328 In Fig. 8, the strain distribution in the central section at each loading stage for the design load, yield load and maximum load shows almost linear patterns which indicate that the steel girder, casing and slab behave monolithically. The neutral axis at maximum load moved by about 25 mm upward from the bottom chord of the top flange. This value differs by 6% compared to that computed by plastic analysis and by 1% compared to that computed by the strain compatibility method. The relative slip reached about.2 mm and indicated that the structure developed performance near to perfect composition. 4 3 2 1-1 -2 5kN(service) -3 1kN -4 162kN(yield) -5 175kN(nominal cal.) -6-3 -2-1 1 2 3 Fig.8: Strain distribution per loading stage 4 3 2 1-1 -2 5kN(service) -3 1kN -4 148kN(yield) -5 175kN(nominal cal.) -6-3 -2-1 1 2 3 IV. CONCLUSIONS The SC hybrid girder is a new type of composite girder that was developed to complement the problems of local buckling and lateral-torsional buckling observed in the conventional composite girder. The two interfaces of the SC hybrid girder should secure perfect composite action until the ultimate strength. Accordingly, two types of SC hybrid girder specimen were designed and fabricated with different shear connection details, and their flexural behaviour was evaluated experimentally up to the ultimate limit state. The following conclusions can be derived from the test results. The SC hybrid girder behaved elastically under the service load and satisfied the serviceability requirement related to the allowable deflection. The measured relative slip was verified to be smaller than.2 mm and indicated that the two types of specimen secured perfect composition. The difference in the shear connection details did not have noticeable effect on the stiffness. Given that perfect composition is achieved, it can be stated that no particular difference would appear in the behavior until the ultimate limit state. Provided that proper design is done, the SC hybrid girder secured sufficient structural stability in view of the facts that the slab failed first through compression because of the action of the rebar even under tension generating partial cracking of the casing and that the section yielded at 3.2 to 3.6 times the service load. ACKNOWLEDGEMENT This research was supported by a grant(13scipa2) from Smart Civil Infrastructure Research Program funded by Ministry of Land, Infrastructure and Transport(MOLIT) of Korea government and Korea Agency for Infrastructure Technology Advancement(KAIA). REFERENCES [1] Jae-Yoon Kang, Jong-Sup Park, Woo-Tai Jung, Evaluation of Flexural Behavior of Steel-Concrete Hybrid Girder Using 8-MPa High-Strength Concrete, International Journal of Advanced Research in Science,, Vol.4, Issue 8, pp.4436-4442, 217 [2] Jae-Yoon Kang, Jong-Sup Park, Woo-Tai Jung, Moon-SeoungKeum, Shear Behavior in Indented Concrete Layers with Different Strengths, Engineering, No.8, pp.423-431. 216 Copyright to IJARSET www.ijarset.com 633