Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual

Similar documents
XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Level measurement CleverLevel LBFS Point level detection

Level measurement CleverLevel LBFS Point level detection

Field case for temperature transmitter Model TIF11

Hazardous Location Cable Glands for Non-Armored Cable (Ex d/e/tb)

Magnetic float switch For vertical installation Model FLS for nuclear power plants

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

Diaphragm pressure gauge

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

APPLICATION MANUAL. XD-I, XD-Iwin, XD-ILwin XD-IC, XD-ICwin, XD-ICLwin

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

Certificate of Compliance

Cable junction boxes with intrinsic fire resistance and insulation integrity

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

Data sheet HYGROPHIL H 4230 process hygrometer

Over pressure Switching pressure difference (typical) Lower range Upper range

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Capacitive level meter CLM 36

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

ALUMAX. High Amperage Power Solutions

Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier

Certificate of Compliance

Ex d. Cooling fins. 4 Joule shock resistant borosilicate glass globe Internal connection terminal box. Stainless steel protective guard A.14 ED.

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors

Load cell Pendeo Process and mounting kits

QGO Oxygen Sensor. Building Technologies HVAC Products

MS SE 30AH 500 Equipment options

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

SITRANS P measuring instruments for pressure

EXPLOSION-PROOF CABLE GLAND - Type ICG 623 Manual

Load cells Type: RTB Safety Instructions

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

PROTEC. High temperature. low voltage electrical material

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

Preparation and Installation of the ENVIRO-SEAL I Rupture Disc

Scales: (Inches) Nominal Length Type and Location. Percentage on tube or Direct Reading on external metal scale with blank tube

Presented By. NicolScales.com Contact Us

CAPACITIVE LEVEL METERS CLM 36

ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY IECEx BKI Page 1 of 8

Diaphragm pressure gauge per EN 837-3,

MICROSTAT-M. Page 1/7. Data Sheet Type /2160. Type / /

Turbimax CUS51D. Technical Information

SERIES OVAL GEAR FLOWMETER MOGF

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting

OPTIMASS 7400 Technical Datasheet

HSK-INOX Hygienic-Design

- Zone 1, 2, 21, 22 - Mechanical strength - Reliability over time - Instant, bright illumination

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

Contrans P Transmitter. Integral Orifice Assembly / EN. Measuring section for the measurement of small flow quantities

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits

Supporting bracket. Cooling fins. Internal reflector. Shock-resistant tempered glass. Ex e terminal housing for a quick connection

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)

Industrial flue gas probes. Instruction manual

InTrac Series versatile retractable housings: When process safety is crucial! INGOLD Leading Process Analytics

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Regulating valves REG 6-65, REG-SS 15-40

NivoRadar. Table of contents. Continuous level measuring system NR 3000 Technical information / Instruction manual. Page

HS-429 Vibration Trip Manual

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G

Cable entries and earthings for secondary substations and industrially manufactured technical buildings

ALUBOX Series Junction boxes in IP66 aluminium alloy

Microlectra bv. Capacitive level meter CLM 36

Zirconia Oxygen Analyzer

OPTISENS TUR Quick Guide. The documentation is only complete when used in combination with the relevant documentation for the signal converter.

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

20 A / 32 A / 63 A / 125 A / 200 A

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables

USER S MANUAL release 1.0

ARI-STEVI 440 / 441 (DN15-250) Control valve - straight through With pneumatic and electric actuators

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

Thermocouple for Flue Gas Temperature Measurements,

SPECIFICATIONS FOR Gas-to-Cable termination

TUFFY T3. Side Mounting Level Controls. Worldwide level and flow solutions FEATURES MODELS APPLICATIONS AGENCY APPROVALS

4-Beam-Turbidity Meter ITM-4

15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 24VAC VAC. 1 Single-phase. SRH VAC Zero cross turn-on

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

SITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview

Transcription:

Vibranivo Mononivo Series Series VN 4000 MN 4000 Instruction manual 010516 1

UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de Scope of this instruction manual: Types VN 4020 4030 MN 4020 4030 Approval CE / TR-CU ATEX 1/2D IEC-Ex t IIIC Electronic modules Relais (DPDT) PNP 2

Table of Contents Safety /warning notes Page 4 Fields of application Page 4 Technical Data Page 4 Application Page 11 Installation Page 13 Spare parts Page 18 Electrical connection Page 19 Switching logic Page 21 Maintenance Page 22 ATEX / IEC-Ex Notes Page 23 3

Safety /warning notes Installation, maintenance and commissioning may be accomplished only by qualified technical personnel. For terminal connection of the device, the local regulations or VDE 0100 (Regulations of German electrotechnical Engineers) must be observed. All field wirings must have insulation suitable for at least 250V AC. The temperature rating must be at least 90 C (194 F). In the case of handling by untrained personnel or handling malpractice, the safety of the device cannot be guaranteed. Fields of application Level limit switch for level limit detection in powder and bulk materials. 4

Technical Data C VN 4020 R 1 1/2 NPT 1 1/4 NPT 1 1/2 1.4541 (321) 1.4581 (316) 1.4404 (316L) 125mm (4.92 ) 170mm (6.69 ) 125mm (4.92 ) 300mm (11.78 ) 1.4581 (316L) 170mm (6.69 ) 125mm (4.92 ) C 1 9 2 9-1.. +16bar (-14.5.. +232psi) -1.. +16bar (-14.5.. +232psi) ~ 1,7kg (3.7 lbs) ~ 2,4kg (5.3 lbs) 5

C VN 4030 R 1 1/2 NPT 1 1/4 NPT 1 1/2 1.4541 (321) 1.4571 (316TI) 1.4404 (316L) 125mm (4.92 ) 300mm (11.78 ) L<4.000mm (157.5 ) 125mm (4.92 ) 1.4581 (316L) L<4.000mm (157.5 ) 125mm (4.92 ) C 1 / 2 9-1.. +16bar (-14.5.. +232psi) ~1,7kg (3.7lbs) +1,9kg/m (+4.2 lbs per 39.9 ) (L) 2 9-1.. +16bar (-14.5.. +232psi) ~2,4kg (5.3lbs) +1,9kg/m (+5.5 lbs per 39.9 ) (L) 6

C MN 4020 G 1" G 1 1/4" G 1 1/2 NPT 1" NPT 1 1/4" NPT 1 1/2" 122mm (4.8 ) 160mm (6.3 ) 130mm (5.12 ) 300mm (11.78 ) 1.4301 (304) 1.4541 (321)/ 1.4404 (316L) 160mm (6.3 ) 130mm (5.12 ) C 1 9 2 9-1.. +16bar (-14.5.. +232psi) -1.. +16bar (-14.5.. +232psi) ~ 1,3kg (2.9 lbs) ~ 2,0kg (4.5 lbs) 7

C MN 4030 G 1" G 1 1/4" G 1 1/2 NPT 1" NPT 1 1/4" NPT 1 1/2" 122mm (4.8 ) 300mm (11.78 ) L<4.000mm (157.5 ) 130mm (5.12 ) 1.4301 (304) 1.4541 (321)/ 1.4404 (316L) L<4.000mm (157.5 ) 130mm (5.12 ) C 1 / 2 9 2 9-1.. +16bar (-14.5.. +232psi) ~1,3kg (2.9lbs) +1,3kg/m (+2.9 lbs per 39.9 ) (L) -1.. +16bar (-14.5.. +232psi) ~2,0kg (4.5lbs) +1,3kg/m (+2.9 lbs per 39.9 ) (L) 8

C 1 T amb 60 C (140 F) 40 C (104 F) T process T amb T process -40 C (-40 F) 60 C (140 F) 150 C (302 F) -40 C (-40 F) 2 T amb 60 C (140 F) T process ø 50mm (ø 1.97 ) 180 mm (7.1 ) T amb -40 C (-40 F) 150 C (302 F) T process -40 C (-40 F) 9

Sensitivity VN 4000 >30 g/l B >150 g/l A 1g/l = 0.06 lb/ft³ MN 4000 >20 g/l >80 g/l >150 g/l >300 g/l 1g/l = 0.06 lb/ft³ Bulk material VN 4000: d < 8mm (0.31 ) MN 4000: d < 20mm (0.79 ) 10

Application VN 4020 MN 4020 (1) VN 4020 <600N MN 4020 <400N 200mm (7.87 ) (2) VN 4020 (1) (2) Mech. load of the sensor Protective angle (canopy) in case of high mechanical load 11

VN 4030 MN 4030 (2) < 250Nm (1) L α max. L / mm ( ) < 5 4.000 (157.5 ) < 45 1.200 (47.2 ) > 45 600 (23.6 ) < 250Nm (1) α (1) (2) Mech. load of the sensor Sliding sleeve: Tighten straining screws with 20Nm 12

Assembly Fixing Threads Teflon tape or flat gasket 80Nm Fixing Flanges Gasket 13

Fixing EHEDG 100Nm (1) (2) (3) (4) (1) Certified flush welding socket must be used (2) Metal-metal support without any gap (3) Sealing ring (4) Welding (observe hygiene requirements) 14

Alignment (1) (1) VN 4000 (1) Ingress protection IP 66 15

Treatment VN 4000 MN 4000 16

Option: Weather protection cover for Ex only approved for Zone 22 17

Spare parts VN 4000 19...230V 50/60 Hz 19...40V DC 18...50V DC PNP pl408265 pl408266 MN 4000 21...230V 50/60 Hz 22...45V DC 18...50V DC PNP pl405265 pl405266 18

Electrical connection All electronic modules: Over voltage category II Relay DPDT VN 4000 MN 4000 1 2 3 4 5 6 7 8 max. 4mm² (AWG12) (4) (4) (4) (4) max. 10A, HBC, 250V, T/F PE + - AC max. 250V, 8A L N DC max. 30V, 5A (1) (1) VN 4000: 19...230V ±10% (3) 50-60Hz 22VA 19... 40V ±10% (3) DC 2W MN 4000: 21...230V ±10% (3) 50-60Hz 22VA 22... 45V ±10% (3) DC 2W 2225Vrms (2) 2225Vrms (1) (2) (3) Power supply Isolating voltage including 10% from EN 61010 19

PNP VN 4000 MN 4000 max. 4mm² (AWG12) 1 2 3 max. 4A, 250V, T/F max. 0,4A PE + - 18...50V ±10% (1) 0,5A (1) Power supply, including 10% from EN 61010 20

Switching logic VN 4000 MN 4000 FSL FSL FSH FSH FSL FSH 3 4 5 6 7 8 3 4 5 6 7 8 (1) 1 3 1 3 (2) 3 4 5 6 7 8 3 4 5 6 7 8 (1) 1 3 1 3 (2) (1) = Relay DPDT (2) = PNP 21

Maintenance Cleaning VN 4000 MN 4000 22

ATEX II 1/2D + IEC-Ex t IIIC Da/Db Notes Permitted relative pressure -0,2...+0,1bar (-2.9 +1.45psi) Zone borders VN 4020 MN 4020 VN 4030 MN 4030 (1) 2D (2) Db (3) 21 (1) 1D (2) Da (3) 20 (1) Category (2) EPL (IEC-Ex) (3) Zone 23

Ambient temperature T max. Surface temperature 60 C (140 F) 110 C (230 F) 120 C (248 F) 130 C (266 F) 140 C (284 F) 150 C (302 F) VN 4000 MN 4000 115 C (239 F) 120 C (248 F) 130 C (266 F) 140 C (284 F) 150 C (302 F) Installation (1) (2) (1) (2) A pull relief must be provided Connect with equipotential bonding of the plant 24

ATEX / IEC-Ex: Further Remarks For installation and field wiring the respectively valid installation regulations of the respective country must be observed. Commissioning only with closed lid. Do not remove the lid (cover) while circuits are alive. Before opening the lid take care, that no dust deposits or whirlings are present. The installation has to be carried out in a way, that mechanical friction or impact does not cause sparks between the aluminium enclosure and steel. Cable glands: Installation according to the regulations of the country, where the product is installed. Not used entries have to be closed with blanking elements certified for this purpose. Where applicable the factory provided parts must be used. A strain relief must be provided for the field wiring cables, when the device is installed with the factory provided cable glands. The diameter of the field wiring cable must match to the clamping range of the cable clamp. If other than the factory provided parts are used, following must be ensured: The parts must have an approval adequate to the approval of the level sensor (certificate and type of protection). The approved temperature range must be from the min. ambient temperature of the level sensor to the max. ambient temperature of the level sensor increased by 10 Kelvin. The parts must be mounted according to the instructions of the supplier. 25