WVU FLOW CYTOMETRY & SINGLE CELL CORE FACILITY

Similar documents
WVU FLOW CYTOMETRY & SINGLE CELL CORE FACILITY

Flowcytometry Dirk Pacholsky

Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting. Shoreline Community College BIOL 288

BASICS OF FLOW CYTOMETRY

Flow Cytometry - The Essentials

High-throughput automation with the Attune NxT Autosampler: consistent results across all wells and across plates

INTRODUCTION TO FLOW CYTOMETRY

11/19/2013. Janine Zankl FACS Core Facility 13. November Cellular Parameters. Cellular Parameters. Monocytes. Granulocytes.

Definitions. What functions does a flow cytometer be able to do? The build of the Flow cytometry and sorting. Flow cytometry

Flow Cytometry SOP: Monocytes from Frozen Cells

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Assistant Product Manager BDBiosciences

ANAT 3231 Cell Biology Lab12 Stem Cell Analysis

seminar

Principles of Immunophenotyping

Anatomy of a flow cytometer

Attune NxT Acoustic Focusing Cytometer The next generation in acoustic cytometry

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Introduction to. BD FACSAria TM Cell Sorter. Flow = Fluid Cyto = Cell Metry = Measurement

Flow Cytometry SOP: 14 color flow for immune activation, senescence, and exhaustion

Detecting human circulating endothelial cells using the Attune Acoustic Focusing Cytometer

Cellometer. for Cell Counting & Analysis. Brewing Yeast Wine Yeast Platelets and Other Small Cells. Image Cytometer

MoxiCyte Viability Kit (#MXA055) User s Guide (Rev )

CRC Flow Cytometry Core Facility Knut och Alice Wallenbergs Stiftelse

Multiplex Fluorescence Assays for Adherence Cells without Trypsinization

FACS Core Facility User Group Meeting. 25. April 2018 Janine Bögli

ALL INFECTOLOGY. and now. Gucker, 1947 Wallace Coulter Coulter Orifice, Kamentsky, 1965 Mack Fulwyler sorter BLOOD:

ALL INFECTOLOGY COMMERCIALLY AVAILABLE DEVICES. and now BLOOD:

Each question may have MULTIPLE correct answers. Select all that are correct.

bulk Great deals! orders! Save on all cytokines and Miltenyi Biotec s EOY12 United Kingdom instrument antibodies! starting kits and separators!

Phagocytosis Assay Kit (IgG PE)

Using Fluorescence Spillover to Advantage

Supplementary Figure 1

Reagent Titration for the ICS Assay

Basic Principles in Flow Cytometry. Flow Cytometry

Cancer inflammation research applications and products

Strategies for Assessment of Immunotoxicology in Preclinical Drug Development

King George's Medical University UP., Lucknow center for advance research

J. Philip McCoy, Jr., Ph.D., H.C.L.D. J. Philip McCoy, Jr., PhD

Gene expression analysis. Biosciences 741: Genomics Fall, 2013 Week 5. Gene expression analysis

Live and Dead Cell Assay

Designing and executing a successful flow cytometry experiment

Flow Cytometry Immune Activation SOP

Cellometer K2. Cellometer K2 Image Cytometer Optimized Analysis of Primary Cells. Image Cytometers. for Cell Counting & Analysis.

Flow cytometry tools for characterization of GMP cell products

Best practices in panel design to optimize the isolation of cells of interest

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

CyTOF 2. Mass Cytometry System

Multicolor flow cytometry analysis of human pluripotent stem cell cultures

Protocol for FACS analysis of HeLa cell transfectants

CyTOF 2 Mass Cytometry System

UCD Flow Cytometry Summer School 2015


DEPArray Technology. Sorting and Recovery of Rare Cells

Protein/Cytokine Array Services

Spherotech, Inc. 1. SPHERO TM Technical Note STN-8 Rev C

High Throughput Suspension Cell and Bead Analysis. Intellicyt ique Screener PLUS

Flexible, Intuitive and Affordable

Evaluation of the CyFlow Cube 6 flow cytometer unit for the assessment of brewing yeast viability and vitality

CORE FACILITY USER FEES FEES FLOW CYTOMETRY CORE FACILITY

The Worlds First Smart Flow Cytometer

UCD Flow Cytometry Summer School Flow Cytometry: Principles & Practice

AMREP FLOW CYTOMETRY CORE FACILITY. Flow Cytometry Data Analysis Workshop Friday 24 th October

LabChip 90 System with DataViewer Software

Measuring gene expression

Antibody Titrations. Institut für HIV Forschung SOP #06-03 (Nov BS) Background. Reagents

BD Accuri C6. Flow cytometry within reach.

Flow cytometry within reach.

Titration of Fluorochrome-Conjugated Antibodies for Labeling Cell Surface Markers on Live Cells

Welcome to the CORES Flow Cytometry Sorter Facility

COS 597c: Topics in Computational Molecular Biology. DNA arrays. Background

Accelerate Your Antibody Discovery and Cell Line Development Workflows with Cyto-Mine

NovoCyte Flow Cytometer

Cellometer Auto 2000 Cell Viability Counter Optimized Analysis of Primary Cells Cellometer Features of the Cellometer Auto 2000

Overview. General. RNA & Microarrays. Information Systems in the Life Sciences

Identification of red and white blood cells from whole blood samples using the Agilent 2100 bioanalyzer. Application Note

Flow Cytometry. Flow Cytometry Basics Guide

What you need to know before designing a panel

Application Information Bulletin: DuraClone IM Tubes Compensation setup for high content DuraClone reagents

Flow Cytometry For New PhDs

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Application Specialist BDBiosciences

Pulse shape analysis (PulSA) to track protein translocalization in cells by flow

Extracellular vesicle cytometry: Technical challenges and solutions. May 11, 2017 Chris Spring, Research Core Facilities

MST Starting Guide Monolith NT.115

Cell Techniques and Flow Cytometry

Webinar Transcript Best practices in optimizing sample processing for improved flow cytometry

Flow cytometry analysis of transcription factor expression during differentiation of hpsc-derived cardiomyocytes

Multiplex Assay Design

Incorporating New, Bright Fluorochromes into Multicolor Panel Design

SOPVII-7. Panel VII: Treg-FACS-staining

PERFECT-COUNT MICROSPHERES

Cytomics in Action: Cytokine Network Cytometry

Advanced Therapeutic Antibody Discovery with Multiplexed Screening

BR-9516B. SNP genotyping analysis for medium to ultra-high throughput. GENOMELAB TM SNPSTREAM GENOTYPING SERIES

SpectraMax Paradigm Microplate Reader

Institute of Science & Technology in Medicine Control of Substance Hazardous to Health COSHH assessment

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Polaris and Callisto: Advances in Cellular Biology. Jordan Moore Senior Field Applications Specialist

acgh studies using GeneFix collected and purified saliva DNA

Transcription:

WVU FLOW CYTOMETRY & SINGLE CELL CORE FACILITY Newsletter Volume 4, issue 2 January 2018 Helpful Hints for Proper Gating of Flow Cytometry Data Inside this Issue 1-2 Helpful Hints for Proper Gating of Flow Cytometry Data In flow cytometry, gating is the means by which we group cell populations based on similar characteristics. Whether you are new to flow cytometry or an old pro gating can be one of the biggest challenges in analyzing flow cytometry data. Trying to identify cell populations when they are similar in size or have similar expression levels can be difficult. There are some general rules which can make the gating process easier. In this article some useful gating rules and recommendations for analyzing flow cytometry data is discussed. Pre-Assay Recommendations Prior to actually performing the assay, there are several things to consider during the experimental planning phase that will make gating easier during data analysis. 1. Have a clear understanding of the markers that will define the population(s) of interest. Check the literature for information on the population(s) of interest. Make sure to use the most current information when choosing markers to identify the population(s). 2. If working with a mixed cell population make sure you have an idea of their sizes and consider using a live/dead dye to gate out dead cells and debris. Remember, dead and dying cells can pick up antibodies and other dyes non-specifically. 3. Have a good idea of the level of expression of each marker. Also, know if treatment or disease state changes the level of expression of each marker. 4. Determine what the controls should be for the assay. Unstained and single stained controls are always required. Even though the instruments are pretty stable, temperature in the room, the staining process, instrument maintenance and the age of the lasers all can affect the data. 5. Consider using FMO (Fluorescence Minus One) controls especially if using more than 4 fluorochromes. FMO controls are additional controls that aid in the identification and gating cells when there is data spreading due to the multiple fluorochromes. 3 4 Flow Cytometers in the Facility Other Instruments in the Facility 5 Fee Schedule 6 FCS Express 6: Spreadsheets 6 New Users Guide 6 Upcoming Holidays & Events Facility Location: 2160 HSCN Phone: 304-293-6273 email: flowcore@hsc.wvu.edu Hours of operation: 9:30 am to 5:00 pm, M-F After hours access is available for experienced users with prior approval from Dr. Kathy Brundage Contact Dr. Brundage at: kbrundage@hsc.wvu.edu

Post-Acquisition Recommendations There are several different gating strategies that are commonly used when defining populations of cells. 1. Forward Scatter (FSC) and Side Scatter (SSC) gating This gating strategy uses size and granularity to identify cells. It is usually the first type of gating done and allows for the removal of dead cells/debris. Dead cells/debris tend to have less FSC (smaller) and more SSC then live cells. To ensure complete exclusion of dead cells, a live/dead stain should be used as well. 2. Gating using a single parameter This gating is usually done after the FSC/SSC gating. It allows you to identify cell populations based on how much of a particular protein a cell is expressing. A simple example is shown in the figure at the beginning of this article (graph on left side). 3. Gating using multiple parameters For this gating you will need to use a two dimensional plot. The parameters on the x-axis and y- axis can be a particular protein/fluorochrome, FSC, SSC or a live/dead stain. By dividing the plot into 4 quadrants you can identify 4 populations. These populations would be: 1. Parameter 1 (+) only 2. Parameter 1 (+) and 2 (+) 3. Parameter 1 (-) and 2 (-) 4. Parameter 2(+) only An example of this type of gating is shown at the beginning of this article (graph on right side). 4. Backgating This is one of the most useful strategies to check your gating, particularly when you have a mixture of cell types with different FSC and SSC characteristics. For this strategy, coloring the gated cell populations with different colors on one graph allows you to visualize the gated populations on other graphs with different parameters. 5. Gating based on pulse area This gating strategy is useful to identify and remove doublets/clusters of cells from your analysis. With this gating, the width (W) for one parameter such as FSC is plotted vs the area (A) or height (H) of the same parameter (FSC). The W parameter can be thought of as a measurement of time of flight. Single cells will have similar W values and cluster tightly together while clusters of two or more cells are larger and will take longer to go through the laser sensing area. This means that cells in clumps will have larger W values then single cells. For this strategy, the gate is put around the cluster of single cells thus excluding the ones with larger W values. An example is shown below: Using the gating strategies discussed above will improve your data analysis and help to generate more consistent and reproducible data. If you have any questions or would like to discuss the gating strategies presented in this article please contact the WVU FCSCCF. http://flowcore.wvu.edu 2

Flow Cytometers in the Facility Operator: Facility Staff FACSAria III Cell Sorter Lasers: 488 nm solid state 561 nm solid state 633 nm solid state 407 nm solid state Detection Parameters: Forward Scatter Side Scatter Simultaneous detection Applications: of 13 fluorochromes Cell Sorting (Aseptic) Cell phenotyping Cell Viability FISH, FRET, SPA Operator: User of Facility Staff LSR Fortessa Lasers: 405 nm solid state 488 nm solid state 561 nm solid state 628 nm solid state Detection Parameters: Forward Scatter Side Scatter Simultaneous detection of 12 fluorochromes Applications: Cell phenotyping Cell Viability Cell Cycle analysis FISH, FRET, SPA http://flowcore.wvu.edu 3

AutoMACS Magnetic Bead separator Operator: User Single extracellular marker cell sorting Depletion/negative cell sorting C1 Single Cell Auto Prep System Operator: User or Staff Uses microfluidics, to separate cells into individual compartments, isolate RNA from the single cells, and generate cdna for downstream genomic applications. Downstream applications: RNA seq DNA seq PCR Format: 96 or 384 chambers per chip gentlemacs Octo Dissociator with Heaters Operator: User Dissociation of tissues into single cell suspension for culture or flow cytometry assays Homogenizes tissues for downstream molecular biology applications MSD Multi-Array Platform Operator: User Applications: Detection of cytokines, cell signaling proteins Multiplexed assay design: (1-10 analytes/plate) Detection range: 1 10,000 pg/ml Sample volumes: 25 l or less Assay Time: 4 6 hours depending on analytes being detected Nanosight NS 300 Operator: User or Staff Determines the size and concentration of particles 10 nm to 1 microns in size Equipped with 4 lasers (405 nm, 488 nm, 532 and 642) to detect fluorescently labeled particles Zetasizer Nano Z Operator: User or Staff Measures the zeta potential of particles in a solution using laser Doppler micro-electrophoresis http://flowcore.hsc.wvu.edu 4

Fee Schedule Instrument Operator For WVU & NIOSH Users AutoMACS For Non-WVU Users Facility Staff or User $14.70/h $22.05/h C1 Single Cell Auto Prep System Facility Staff $210/plate $315/plate User No Cost $112.50/plate FACSAria III Analysis: Facility Staff $52.50/h $78.75/h Analysis: User $34.65/h $51/98/h Sorting $77.70/h $116.55/h Sorting Setup $19.43/sort $29.15/sort gentlemacs LSRFortessa Facility Staff or User $10.50/sample $15.75/sample Facility Staff $52.50/h $78.75/h User $34.65/h $51.98/h MSD Sector Imager NanoSight NS300 Facility Staff or User $10.50/h $15.75/h Facility Staff $61.00/h $91.50/h User $42.50/h $63.75/h Zetasizer Nano Z Facility Staff User $25/sample + $52.50/h $25/sample $38/sample + $78.75/h $38/sample + $15/h The facility uses ilab scheduling/billing software from Agilent to manage the use of the facility s instrumentation. If you would like to use the instruments housed in the facility please use the URL shown below to register as a WVU User and to login to reserve an instrument. https://wvu.corefacilities.org/account/login http://flowcore.hsc.wvu.edu 5

FCS Express 6: Spreadsheets In FCS Express 6, Excel style spreadsheets can be inserted into a layout. These spreadsheets function just like typical Excel spreadsheets. These spreadsheets allow you to add statistics directly into them as well as adding statistics from data files in the data list. To insert a spreadsheet into a layout: 1. Go to the Insert tab in the software and select Spreadsheet then New 2. If you click on the spreadsheet to select it, two new tabs appear Spreadsheet-Layout and Spreadsheet Formula 3. Now you are ready to add any statistics and formulas to the spreadsheet 4. To add statistics from data files to the spreadsheet, drag and drop the files either individually or in a group onto the spreadsheet. You do not have to open each file to add the data. 5. Spreadsheets created in FCS Express can be exported in standard Excel formats such as.xls,. cvs,.xml and.txt. Check the De Novo Software website for more details and tutorials. Upcoming Holidays & Events January 15 Martin Luther King s Day Facility Closed January 16 February 13 FCS Express6 Seminar: Clustering with tsne & SPADE FCS Express6 Seminar: Cell Cycle & Proliferation 2:30 pm 4 pm, HSCN 2094 2:30 pm 4 pm HSCN 2094 March 30 Spring Break Holiday Facility Closed Note to users: Please remember to acknowledge the grants that support the WVU Flow Cytometry & Single Cell Core in all your publications. The grant numbers are listed below: MBRCC CoBRE grant: GM103488/RR032138 WVCTS grant: GM104942 WV InBRE grant: GM103434 Fortessa S10 grant: OD016165 New User Guide Hands-on training for FACSCaliber, LSRFortessa, C1 Single Cell Auto Prep System, NanoSight NS300 and Zetasizer Nano Z is mandatory for all new users and must be scheduled by consultation with the facility director. Training will initiate with user s first experiment. Due to the complexity of the instruments and software, facility staff will fully assist with the acquisition of the first dataset and will continue with additional assistance on a needs basis until users are comfortable operating the instrument on their own. Sorting on the FACSAria is by facility staff only. NanoSight NS 300 use Stroke CoBRE grant GM109098 and WVCTS grant GM104942 ZetaSizer NanoZ use Stroke CoBRE grant GM109098 and WVCTS grant GM104942 http://flowcore.hsc.wvu.edu 6