Technical Specification for Helical Fittings for Overhead Power Lines

Similar documents
Technical Specification for Live Line Tap Connectors

Technical Specification for Galvanised Fabricated Steelwork

Technical Specification for Steel Forged Fittings

Technical Specification for Aluminium Castings, Pole Caps and Pressed Symbols

660 Volts 630 & 800AMP

Technical Specification for LV ABC Fuse Switch Disconnectors

Technical Specification for Low Voltage Aerial Bundled HDPE Insulated Cables

Technical Specification for Insulated Low Voltage Single Core Copper Cable

Technical Specification for 12kV, 24kV and 36kV Disconnector (Isolators)

Technical Specification for Outdoor Porcelain Station Post Insulators

Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable

094: 2000 CEB STANDARD. MEDIUM VOLTAGE PIN INSULATORS & HARDWARE (12kV & 36 kv) CEYLON ELECTRICITY BOARD SRI LANKA

11KV PORCELAIN INSULATORS AND FITTINGS

093 : 2000 CEB STANDARD MEDIUM VOLTAGE PIN POST INSULATORS AND HARDWARE CEYLON ELECTRICITY BOARD SRI LANKA

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

FIJI ELECTRICITY AUTHORITY BIDDING DOCUMENT

SPECIFICATION FOR 11 & 33kV COMPOSITE INSULATORS Part 1: Pin Type

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

TABLE OF CONTENTS. Page FOREWORD INTRODUCTION SCOPE NORMATIVE REFERENCES

RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES

NPS/002/001 Technical Specification for Earthing Materials

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH

NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings

TABLE OF CONTENTS. Page FOREWORD INTRODUCTION SCOPE NORMATIVE REFERENCES

Technical Specification for Low Voltage Regulator

SPECIFICATION FOR STOCKBRIDGE TYPE VIBRATION DAMPERS FOR DISTRIBUTION AND TRANSMISSION OVERHEAD LINES

Suspension clamps. Contents. General Oscillating and trunnion type suspension clamps forged.. 3. Oscillating type suspension clamps cast...

SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS

General Requirements. Technical Specifications for Insulators of Transmission Lines

Specification No. CSC- XXIX/DH/UH/P&D/

MSME Testing Centre, 65/1, G. S. T. Road, Guindy, Chennai, Tamil Nadu. Discipline Electrical Testing Issue Date

10-SDMS-02 SPECIFICATIONS FOR BARE COPPER CONDUCTORS

Conduits. Technical Specification for Conduits and Associated Materials. JTS Version 1

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE

Technical Specification for Substation 11kV and 22kV Single Core Underground Cable

SPECIFICATION FOR DISC INSULATORS (Standard Type)

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 22 kv, SINGLE CORE, 95mm 2 COPPER

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE

APDRP SCHEME, WESCO. Technical Specification for 33KV Air Break Switch PART 1: SCOPE AND CONDITIONS

Technical Specification for. Insulators. Part 1. Insulators for High and Extra-High Voltage Overhead Lines

Technical Specification for Single Core 19/33kV Copper / TR-XLPE Underground Cable

TABLE OF CONTENTS. FOREWORD... Error! Bookmark not defined. INTRODUCTION SCOPE NORMATIVE REFERENCES DRAWING...4

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN

31-SDMS-03 REV. 01 SPECIFICATIONS FOR

TABLE OF CONTENTS INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

33-SDMS-02 SPECIFICATIONS FOR

Technical Specification for 12kV, 24kV AND 36kV Unitised Ganged Airbreak Switches

Specification Technical Requirements for Overhead Conductors up to and including 33 kv

Date: TECHNICAL SPECIFICATION FOR (LT,11KV, 33KV) PORCELAIN PIN INSULATORS

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Substation Insulators (63 kv- 400 kv)

MGVCL/MM/1043/13-14/11 KV Disc Insulators (Porcelain)

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )

Galvanised Fabricated Metalwork

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN

TECHNICAL SPECIFICATION FOR LT PIN/SHACKLE INSULATORS

SPECIFICATION FOR HT PIN (11KV & 22KV) AND 11KV DISC. INSULATORS:

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable

NPS/003/015 Technical Specification for 33kV, 66kV and 132kV Post Insulators

NPS/003/033 Technical Specification for Substation Support Structures

11-SDMS-01 REV. 03 ( )

37-SDMS-01 REV. 03 SPECIFICATIONS FOR

P.V.C. INSULATED UNARMOURED COPPER CABLES

SPECIFICATION FOR STAY INSULATORS (PORCELAIN)

MATERIAL STANDARD FOR CABLES AND WIRES

NPS/002/017 Technical Specification for 66 kv and 132 kv Cable Accessories

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

SPECIFICATION FOR HT PIN (11KV & 22KV) AND 11KV DISC. INSULATORS: -

ACCELARATED POWER DEVELOPMENT AND REFORM PROGRAMME. Technical Specification (T.S)

TRANSMISSION NEW PROJECTS DEPARTMENT TRANSMISSION LINES TOWER DESIGN AND SPECIFICATIONS SECTION ATHENS - GREECE SPECIFICATION TR-1

TECHNICAL SPECIFICATION OF ACCESSORIES SUITABLE FOR 7/3.15 mm G.I. EARTH WIRE

Title Cables for Railway Signalling Applications - Traction Return Bonding and Track Connection Cables

Maharashtra State Electricity Distribution Co. Ltd.

MATERIAL SPECIFICATION FOR STEEL REINFORCEMENT FOR CONCRETE

SRI LANKA STANDARD SPECIFICATION FOR THREE-PIN PLUGS, SOCKET-OUTLETS AND SOCKET-OUTLET ADAPTORS

CONSTRUCTION SPECIFICATION FOR EXPANDED METAL ANTI-GLARE SCREEN

Transmission Line General Requirements Including Typical Overhead Line Structures. Document Number: 1-03-FR-09

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF UNDERPASS LUMINAIRES

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION

MATERIAL SPECIFICATION FOR STEEL REINFORCEMENT FOR CONCRETE

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

AS/NZS :2016. High-strength steel fastener assemblies for structural engineering Bolts, nuts and washers AS/NZS :2016

056 : 1997 CEB STANDARD

Maharashtra State Electricity Distribution Co. Ltd.

Maharashtra State Electricity Distribution Co. Ltd.

MATERIAL SPECIFICATION FOR LUMINAIRE RAISING AND LOWERING EQUIPMENT

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

SECTION PARK NON-SEGREGATED BUS SPECIFICATION

DBI-SALA Uni 8 Horizontal Lifeline Cable System

NPS/002/013 Technical Specification for Telephone and Pilot Cable Joints

Specification for Fabrication of Steelwork for Pole Structures

SPECIFICATION FOR ALL ALUMINIUM ALLOY STRANDED CONDUCTOR

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

12-SDMS-01 Rev.02 SPECIFICATIONS FOR

9KV/18KV METAL OXIDE LIGHTNING ARRESTORS WITHOUT GAPS WITH STANDARD NOMINAL DISCHARGE CURRENT 5KA

TECHNICAL SPECIFICATION FOR CONDUCTOR HARDWARE FITTING FOR 11/22/33 kv OVERHEAD POWER LINES

SWER OVERHEAD CONDUCTOR DISTRIBUTION SYSTEM AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

Transcription:

Ergon Energy Corporation Limited Technical Specification for Helical Fittings for Overhead Power Lines ETS01-09-03 Specification ETS01-09-03 Ver 3

Contents 1. Purpose and Scope... 4 2. References... 4 2.1 Applicable Standards... 4 3. Drawings... 5 3.1 Drawings by the Purchaser... 5 4. Service Conditions... 5 5. Design and Construction... 5 5.1 Armour Grip Suspension Units (AGSU)... 5 5.2 Helical Armour Rods and Conductor Repair Rods... 6 5.3 Helical Full Tension Splices and Termination Fittings... 6 5.4 Helical Insulator Ties... 6 5.5 Pre-formed Dead Ends for Service Cables... 7 5.6 Finish... 7 5.7 Markings... 7 5.8 Technical Characteristics... 7 6. Performance and Testing... 8 6.1 Type Tests... 8 6.2 Batch Tests... 8 6.3 Witnessing of Tests... 8 7. Risk Assessment... 8 8. Quality Assurance... 8 8.1 Purchasers Policy... 8 8.2 Documentary Evidence... 8 9. Samples... 9 9.1 Production Samples... 9 9.2 Sample Delivery... 9 2 Specification ETS01-09-03 Ver 3

10. Packaging and Marking... 9 10.1 Packaging... 9 10.2 Packaged Lots... 9 11. Service Performance... 9 12. Reliability... 10 12.1 Service Life... 10 12.2 Evidence in Support of Reliability... 10 13. Training... 10 13.1 Training Material... 10 13.2 Training Audio Visuals... 10 14. Environmental Considerations... 11 15. Information to be Provided... 11 15.1 Specific Technical Requirements... 11 15.2 Checklist of Supporting Documentation... 11 16. Attachment 1 Technical Details... 12 17. Attachment 2 Electrical Type Test Details... 13 18. Attachment 3 Technical Document Checklist... 14 3 Specification ETS01-09-03 Ver 3

1. Purpose and Scope This specification sets out the requirements for the manufacture, supply, testing and delivery of Helical Fittings for use on overhead electricity networks in a totally exposed environment. 2. References 2.1 Applicable Standards The connectors shall be designed, manufactured and tested in accordance with the relevant parts of the following Standards and all amendments issued from time to time except where varied by this specification. STANDARD AS 1110 AS 1111 AS 1154 AS 1214 AS 1275 AS 1444 AS 1531 AS 1746 AS 1789 AS 1222 AS 2738 AS 2837 AS 2848 AS/NZS 2947 TITLE ISO metric precision hexagon bolts and screws ISO metric commercial hexagon bolts and screws Insulator and conductor fittings for overhead power lines Hot-dip galvanized coatings on threaded fasteners Metric screw threads for fasteners Wrought alloy steels - Standard, hardenability (H) series and hardened and tempered to designated mechanical properties Conductors - Bare overhead - Aluminium and aluminium alloy Conductors - Bare overhead - Hard-drawn copper Electroplated coatings - Zinc on iron or steel Steel conductors and stays- Bare overhead Copper and copper alloys - Compositions and designations Wrought alloy steels - Stainless steel bars and semi-finished products Aluminium and aluminium alloys - Compositions and designations Insulators - Porcelain and glass for overhead power lines- Voltages greater than 1000 V ac AS 3607 Conductors - Bare overhead, aluminium and aluminium alloy - Steel reinforced AS 3608 AS 3609 Insulators - Porcelain and glass, pin and shackle type-voltages not exceeding 1000 V ac Insulators - Porcelain stay type-voltages greater than 1000V ac Page 4 of 14 Specification ETS01-09-03 Ver 3

STANDARD AS 4169 AS/NZS 4680 AS/NZS ISO 9001 TITLE Electroplated coatings - Tin and tin alloys Hot-dip galvanised (zinc) coatings on fabricated ferrous articles Quality management systems - Requirements 3. Drawings 3.1 Drawings by the Purchaser There are no drawings attached to this specification. 4. Service Conditions The connectors will be exposed to the following environmental conditions: Temperatures Solar Radiation Level Precipitation 45 o C summer day time -5 o C winter night time 1 000 W/m 2 with high ultraviolet content Tropical summer storms with gust wind speeds above 160 km/h, and an annual rainfall in excess of 1 500mm Humidity Extended periods of relative humidity in excess of 90% Pollution Areas of coastal salt spray and/or industrial pollution with equivalent salt deposit densities in the range 2.0 to 3.0 g/m 2 5. Design and Construction 5.1 Armour Grip Suspension Units (AGSU) The helically formed conductor fittings and the accessories of the AGSU shall meet the requirements of the Section 3 of AS 1154.3 and the following: Suit conductor types as detailed in the tender schedules. The conductors will be fully greased. The armour rod ends shall be appropriately shaped to prevent conductor damage. Neoprene inserts shall be capable of withstanding conductor temperatures of 50C to 900C without permanent loss of essential properties and shall have adequate resistance to ozone, UV radiation, mineral oils and grease and other atmospheric contaminants. Page 5 of 14 Specification ETS01-09-03 Ver 3

Nominal holding tension (withstand slip) of the fittings shall be, 15% of the MCBL of the conductor or 3.5kN, whichever is lower. Be suitable for line deviations up to and including 30 degrees. AGSU housing shall be suitable for attachment to a socket tongue rated 70kN and be supplied complete with a clevis bolt in accordance with superseded AS 1154.2 Reference 16/B, figure 44. The suspension assembly shall have a minimum failing load equivalent to 60% of the conductor MCBL. 5.2 Helical Armour Rods and Conductor Repair Rods The helically formed armour rods and repair rods shall meet the requirements of Section 4 of AS 1154.3 and the following: Suit the conductors as detailed in the tender schedules. The conductors will be fully greased. Be designed to minimise the mechanical stresses in the conductor and protect the conductor from damage due to electrical arcing at the support. The rod ends shall be appropriately shaped to prevent conductor damage. Each rod of the set shall be "centre-marked" in accordance with the colour code specified in clause 1.8 of AS 1154.3 5.3 Helical Full Tension Splices and Termination Fittings The helically formed full tension splices and termination fittings shall meet the requirements of Section 2 of AS 1154.3 and the following: Suit the conductors as detailed in tender schedules. The conductors will be fully greased. The ends of the individual helically formed rods comprising splice/termination fitting shall be appropriately shaped to prevent conductor damage. Be supplied as a unit. Each subset of splices shall be "centre-marked''. Each termination fitting shall have distinct cross-over" marks. The colour coding shall be in accordance with clause 1.8 of AS 1154.3. 5.4 Helical Insulator Ties The helically formed insulator ties shall meet the requirements of Section 3 of AS 1154.3 and the following: Suit conductor/insulator and insulator/conductor with armour rods combinations detailed in the tender schedules. Insulator top ties and side ties will be required. Shall incorporate a neoprene moulding or similar to prevent abrasive wear on conductor/insulator interface. Preference will be given to ties with a neoprene pad moulded onto the tie. Neoprene (or similar material) shall be capable of withstanding conductor temperatures of 50C to 900C without permanent loss of essential properties and shall have adequate resistance to ozone, UV radiation, mineral oils and grease and other atmospheric contaminants. The ends of the individual helically formed rods comprising the fitting shall be appropriately shaped to prevent conductor damage. Shall be able to accommodate line deviations up to 10 0 Page 6 of 14 Specification ETS01-09-03 Ver 3

Shall have a nominal holding tension (withstand slip) of 15% of the MCBL of the conductor or 3.5kN, whichever is lower. Shall have a minimum failing load of 20% MCBL of conductor when tested in accordance with clause 3.2.2.2 of AS 1154.3 The neck diameter of the insulator shall be specified in the item description of the schedule. 5.5 Pre-formed Dead Ends for Service Cables The pre-formed dead ends for service cables shall meet the requirements of Section 5 of AS 1154.3 and the following: Shall be suitable for use with 0.6/1kV PVC insulated hard drawn copper aerial service cables complying with AS 3147and PVC insulated copper neutral screened aerial service cables to AS 3155 as nominated in the tender schedules. Shall be double insulated type comprising of neoprene sleeve and a set of gritted helically formed galvanised steel (or stainless steel) wires to suit the application. The ends of the steel wires shall be appropriately protected to prevent damage to the service cable during or after installation. Nominated holding tensions for the fitting shall comply with Appendix A of AS 1154.3. 5.6 Finish The fittings shall be designed, manufactured and finished so as to avoid sharp radii of curvature, ridges and imperfections that may cause radio interference or harmful corona discharge or employee injury, when installed in accordance with recommended procedure. Materials used in the manufacture of fittings shall be compatible with the conductor with which they will be contact. All ferrous metal parts, except those made of stainless steel shall be hot dipped galvanised in accordance with AS/NZS 4680. 5.7 Markings Each fitting shall be provided with an identification tag marked with the following information: The manufacturer's name or trademark The year of manufacture Ergon Stock Code Manufacturer's part number Conductor type and stranding (if fitting is suitable for more than one conductor all sizes shall be listed on the tag) 5.8 Technical Characteristics Tenderers shall provide detailed drawings for all items tendered. Page 7 of 14 Specification ETS01-09-03 Ver 3

6. Performance and Testing 6.1 Type Tests Type test reports carried out in accordance with AS 1154.3 shall be submitted with the tender. Short - time current for the Short -Time Current Test shall be the two second short time current rating of the highest rated conductor associated with the fitting. 6.2 Batch Tests The following batch tests shall be carried out prior to the delivery of fittings. a) Verification of dimensions. b) Mechanical tests as per clauses 2.4.2 and 2.2.1 of AS 1154.3 (for termination fittings and full-tension splices) and Clauses 3.3.2 and 3.2.2 of AS 1154.3 (for AGSUs and insulator ties). c) Galvanising test (if applicable) Each delivery shall be accompanied with a certificate of compliance. The test certificates shall be held by the Supplier and be submitted to the purchaser on request within 24 working hours. 6.3 Witnessing of Tests The Purchaser reserves the right to witness all or any type or batch test and to select the fittings for type of batch testing. The Purchaser also reserves the right to appoint or nominate an Inspecting Engineer to act on its behalf. The Supplier shall provide a minimum of two weeks advance notice to the Purchaser of any intention to carry out this testing. The Purchaser reserves the right to test all equipment in accordance with the specified Australian Standards or the requirements of this specification. 7. Risk Assessment There is no requirement for manufacturer provided safety risk assessments for the items covered in this specification. 8. Quality Assurance 8.1 Purchasers Policy It is the Purchaser s policy to procure goods, equipment and services from sources that demonstrate the ability to supply quality products. 8.2 Documentary Evidence Tenderers are required to submit documentary evidence that the design and manufacture of the fuses offered is in accordance with AS/NZS/ISO 9001. This documentation shall include the Capability Statement associated with the Quality System Certification. Page 8 of 14 Specification ETS01-09-03 Ver 3

Tenderer's attention is drawn to MP000801F100: Management Systems Information Schedule (Form) which forms an integral part of this specification. 9. Samples 9.1 Production Samples When requested, production samples of each item tendered shall be submitted to assist in the evaluation of the tender. 9.2 Sample Delivery Each sample shall be delivered freight free, suitably crated and packaged and labelled with the following information: Name of Supplier and this Contract No. Contract Item Numbers Any supporting data on features or characteristics 10. Packaging and Marking 10.1 Packaging Each fitting shall be supplied separately packed in cartons. Gross weight of the carton shall not exceed 20kg. The cartons should be sufficiently sturdy to allow for storage on shelves by stacking on a pallet. All components of the fittings with more than one component shall be packed in the same carton. 10.2 Packaged Lots Each packaged lot shall be marked with the following information: Manufacturers Name Purchase Order Number Contract No. Ergon Stock Code Item Description Pack Size Pack Weight 11. Service Performance Suppliers shall state: (a) the period of service achieved by the items tendered within Australian service conditions; Page 9 of 14 Specification ETS01-09-03 Ver 3

(b) (c) Australian electricity supply authorities who have a service history of the items tendered; AND Contact names and phone numbers of relevant employees of those supply authorities who can verify the service performance claimed. 12. Reliability 12.1 Service Life Suppliers are required to comment on the reliability of the equipment and the performance of the materials tendered for a service life of 35 years under the specified system and environmental conditions. 12.2 Evidence in Support of Reliability Such comments shall include evidence in support of the reliability and performance claimed including information on Failure Mode and Effect Analysis. 13. Training 13.1 Training Material Training material in the form of drawings, instructions and/or audio visuals (in CD format) are required to be provided for the items accepted under the tender. The Tenderers shall allow the cost of production and delivery of training material in the tendered prices. The training materials should include but not be limited to the following topics: Handling Storage Application (particularly in areas of heavy coastal pollution) Installation Maintenance Environmental performance Electrical performance Mechanical performance Disposal 13.2 Training Audio Visuals The successful Tenderer is required to provide training audio visuals for the Purchaser's staff/contractors in the correct use of all items to be supplied under the contract. Training audio visuals are to be supplied BEFORE the 1st deliveries are made under the contract. The format and content of the audio visuals will be subject to negotiation between the Purchaser and the successful tenderer concerned. It is expected that as a minimum, the Page 10 of 14 Specification ETS01-09-03 Ver 3

audio visuals will detail the correct installation practice for all items covered by the contract. The number of audio visuals required, in CD format, is thirty (30). Permission shall be given to the Purchaser to make additional copies if required. In the production of the audio visuals, the Purchaser will make available suitable staff and equipment to demonstrate the recommended installation techniques. 14. Environmental Considerations Suppliers are required to comment on the environmental soundness of the design and the materials used in the manufacture of the items tendered. In particular, comments should address such issues as recycling and disposal at the end of service life. 15. Information to be Provided 15.1 Specific Technical Requirements The specific technical requirements for the items tendered shall be as stated in Attachments 1 and 2 of this specification. The supplier shall provide all details requested by Attachments 1 and 2 and shall guarantee such data. 15.2 Checklist of Supporting Documentation Attachment 3 details a checklist of supporting technical documentation which is required to be submitted with the tender. Page 11 of 14 Specification ETS01-09-03 Ver 3

16. Attachment 1 Technical Details NOTE: A separate schedule is to be provided for each item tendered except where information common to all items which only needs to be provided once. SPECIFICATION ITEM NO: DESCRIPTION: STOCK CODE: Particulars Units Tenderer s Response Manufacturer's Name & Address Place of Manufacture Manufacturer's Product Catalogue Number Manufacturer's Drawing Number Product Material: Alloy type & Australian Standard Will Batch Test Certificates be supplied? Type Test Report/Certificate No Yes/No Packaging: Pack Size Pack Weight kg SIGNATURE OF TENDERER: Page 12 of 14 Specification ETS01-09-03 Ver 3

17. Attachment 2 Electrical Type Test Details A separate schedule is to be provided for each item tendered except where information common to all items, which only needs to be provided once. This information is NOT required for the support fittings. SPECIFICATION ITEM NO: STOCK CODE: DESCRIPTION: Particulars Units Tenderer s Response Australian/International Standard for Type Tests Resistance tests: (a) Voltage drop across fitting μv (b) Voltage drop across equivalent length of conductor μv (c) Ratio Voltage drop across connector Voltage drop across conductor Heat-cycling tests: Number of Cycles Maximum Temperature of Connector Maximum Temperature of Conductor Initial Resistance Final Resistance Short-time current test: Maximum short circuit current Duration of maximum short circuit current o C o C Ω Ω ka seconds SIGNATURE OF TENDERER: Page 13 of 14 Specification ETS01-09-03 Ver 3

18. Attachment 3 Technical Document Checklist Clause Ref. Particulars Tenderer s Response Have full and comprehensive details been submitted WITH the tender documents associated with each of the following items? 5.8 Detailed drawings Yes/No 6.1 Type Test Reports Yes/No 8.2 Documentary evidence of the Quality System Certification of BOTH the SUPPLIER and the MANUFACTURER (including Capability Statement) Yes/No 11 Service Performance Yes/No 12 Reliability Yes/No 13.1 13.2 Availability of Training Materials Yes/No 14 Environmental Considerations Yes/No 15 Completed Attachment of Technical Details Yes/No NAME OF TENDERER: ADDRESS OF TENDERER: SIGNATURE: FOR AND ON BEHALF OF TENDERER DATE: Page 14 of 14 Specification ETS01-09-03 Ver 3