Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Similar documents
Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 2 Heiselberg, Per Kvols. Publication date: 2016

A Study on the Variation of Heating & Cooling Load by the Various Shading and Performance of Window in Office Buildings Seok-Hyun Kim 1, Kyung-ju Shin

ADVANCED FAÇADES AND HVAC SYSTEMS: PRELIMINARY RESULTS OF FULL-SCALE MONITORING

Aalborg Universitet Investigation of Different Configurations of a Ventilated Window to Optimize Both Energy Efficiency and Thermal Comfort

A Study on the Variation of Heating and Cooling Load According to the Use of Horizontal Shading and Venetian Blinds in Office Buildings in Korea

An enhancement of the daylighting from side-window using two-section venetian blind

Two-Pipe Chilled Beam System for Both Cooling and Heating of Office Buildings

Heiselberg, Per Kvols; Andresen, Inger; Perino, Marco; van der Aa, Ad

Aalborg Universitet Two-Pipe Chilled Beam System for Both Cooling and Heating of Office Buildings General rights Take down policy

The effect of shading design and control on building cooling demand

Potential of Natural Ventilation in Shopping Centres Diederichsen, Alice; Friis, Kristina; Brohus, Henrik; Tranholm, Gitte T.

An Experimental Study for the Evaluation of the Environmental Performance by the Application of the Automated Venetian Blind

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Effects of Fixed and Motorized Window Louvers on the Daylighting and Thermal Performance of Open-Plan Office Buildings

Dynamic facades, the smart way of meeting the energy requirements Johnsen, Kjeld; Winther, Frederik Vilbrad

additional cooling energy consumption. Because the thermal resistance of windows has always been a weak point, even with vacuum glass or low-e glass,

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 7 Heiselberg, Per Kvols. Publication date: 2016

Analysis of a plus-energy house for improved building and HVAC system design

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

Building Technology Research in Architectural Practice: Lessons Learned from Implementations of Energy-Efficient Advanced Building Technologies

Sensitivity Analysis Applied in Design of Low Energy Office Building Heiselberg, Per Kvols; Brohus, Henrik

HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya

Parametric analysis of the operation of nocturnal radiative cooling panels coupled with in room PCM ceiling panels

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Intelligent Glazed Facades for Fulfilment of Future Energy Regulations Winther, Frederik Vildbrad; Heiselberg, Per Kvols; Jensen, Rasmus Lund

A Study on the Evaluation of Heating and Cooling Energy Efficiency in Residential Buildings for Climatic Zones of Turkey

Automating the Balance of Energy Performance with Occupant Comfort with Smart Fenestrations

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Renovation of a Detached Single-Family House into an Energy Efficient Low Energy House Larsen, Tine Steen; Maagaard, Steffen; Jensen, Rasmus Lund

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Measurements of Energy Performance and Indoor Environmental Quality in 10 Danish Passive Houses Larsen, Tine Steen; Jensen, Rasmus Lund

Analysis of Indoor Luminous Environment and Power Generation by Roll Screen and Venetian Blind with PV Modules

Multi-angled façade system for office building renovation Hannoudi, Loay Akram; Christensen, Jørgen Erik; Lauring, Gert Michael

Aalborg Universitet. Published in: Passive and Low Energy Architecture 2008 Conference, Dublin, 22<sup>nd</sup> to 24<sup>th</sup> October 2008

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

ADAPTIVE LOW-E DOUBLE GLAZING WINDOW

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Assessing the energy performance of modern glass facade systems

Solar Shading System Based on Daylight Directing Glass Lamellas

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

A Study on the Analysis of Indoor Temperature. According to the PCM Temperature Applied to the. Double Skin Facade System for Saving Cooling

HOW CURRENT TRENDS IN THE DESIGN OF FACADES INFLUENCE THE FUNCTIONAL QUALITY OF INTERIOR SPACES

Energy Saving Benefits of Daylighting Combined with Horizontal Exterior Overhangs in Hot-and-Humid Regions

Comsol Multiphysics for building energy simulation (BES) using BESTEST criteria Jacobs, P.M.; van Schijndel, A.W.M.

MODELLING THE IMPACT OF GLAZING SELECTION ON DAYLIGHTING PERFORMANCE OF AN OFFICE BUILDING IN SINGAPORE USING ENERGYPLUS

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Assessing the Effect of Window, its Shape and Shading Devices on the Heating and Cooling Energy Consumption (In the Region of Mashhad City)

Parametric Louver Design System Based On Direct Solar Radiation Control Performance

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Simplified methods to evaluate energy use for space cooling in the energy certification

Measured temperature and moisture conditions in the roof attic of a one-and-a-half story house Nielsen, Anker; Morelli, Martin

Computational Fluid Dynamics and Building Energy Performance Simulation Nielsen, Peter Vilhelm; Tryggvason, T.

DYNAMIC FACADE. BUILDING ENERGY EFFICIENCY REHABILITATION.

Characterization and performance evaluation of solar shading devices

Proceedings of the 2014 Winter Simulation Conference A. Tolk, S. Y. Diallo, I. O. Ryzhov, L. Yilmaz, S. Buckley, and J. A. Miller, eds.

EE2E045 A Calculation Method on the Energy Demand of Urban Districts

BEST3 / 3 April 2012 / Mark Perepelitza. enclosure performance research applications in professional practice

Empirical validation data sets for double skin facade models Larsen, Olena Kalyanova; Jensen, Rasmus Lund; Heiselberg, Per Kvols

Evaluation methodology and implementation for natural ventilation control strategies

Thermal comfort assessment of Danish occupants exposed to warm environments and preferred local air movement

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 1 Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

Empirical validation data sets for double skin facade models Larsen, Olena Kalyanova; Jensen, Rasmus Lund; Heiselberg, Per Kvols

Aalborg Universitet. Energy Gaining Windows for Residental Buildings Kragh, Jesper; Laustsen, Jacob Birck; Svendsen, Svend. Publication date: 2008

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Energy Analysis of Using Thermal Mass in a Hot Humid climate

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

Energy consumption simulation of the prototypical building for optimizing the orientation of building model in the simulated environment

Energy Consumption and Indoor Environment Predicted by a Combination of Computational Fluid Dynamics and Building Energy Performance Simulation

Monitoring of Advanced Facades and Environmental Systems

Comparison of Energy and Visual Comfort Performance of Independent and Integrated Lighting and Daylight Controls Strategies

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

DEVELOPMENT AND CONSTRUCTION OF BIOCLIMATIC DOUBLE SKIN ACTIVE FACADE FOR HOT AND HUMID CLIMATE OF UAE

OPENING DESIGN TO IMPROVE THE NATURAL VENTILATION PERFORMANCE OF HIGH-RISE RESIDENTIAL BUILDINGS

Satyen Mukherjee, Dagnachew Birru, Dave Cavalcanti, Eric Shen, Maulin Patel, Yao-Jung Wen, and Sushanta Das, Philips Research North America

Assessment of Energy Performance of Window Technologies for Commercial Buildings

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Simulation based façade control implemented as a responsive building element

Introduction to basics of energy efficient building design

OPTIMIZATION OF WINDOW-WALL RATIO FOR DIFFERENT BUILDING TYPES

IMPACT OF CLIMATE CHANGE

Passive Houses for Arctic Climates

New solar shading system based on daylight directing solar glass lamellas

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

The effect of shading devices on the cooling load of residential buildings in Seoul, South Korea

Analysis of the effect of artificial lighting on heating and cooling energy in commercial buildings

European Timber Windows & Doors

COOLING LOADS AND OCCUPANT COMFORT IN HIGHLY GLAZED BUILDINGS AND THE EFFECTIVE EVALUATION OF WINDOW RETROFITS

Transcription:

Aalborg Universitet CLIMA 2016 - proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols Publication date: 2016 Document Version Publisher's PDF, also known as Version of record Link to publication from Aalborg University Citation for published version (APA): Heiselberg, P. K. (Ed.) (2016). CLIMA 2016 - proceedings of the 12th REHVA World Congress: volume 2. Aalborg: Aalborg University, Department of Civil Engineering. General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.? Users may download and print one copy of any publication from the public portal for the purpose of private study or research.? You may not further distribute the material or use it for any profit-making activity or commercial gain? You may freely distribute the URL identifying the publication in the public portal? Take down policy If you believe that this document breaches copyright please contact us at vbn@aub.aau.dk providing details, and we will remove access to the work immediately and investigate your claim. Downloaded from vbn.aau.dk on: juli 25, 2018

Analysis of The Thermal Load Variations Affected by Window Orientation, Transmitted Solar and Blind Parameters Jeong Eun Son #1, Yeo Beom Yoon #2, Rashmi Manandhar *3, Kwang Ho Lee #4 #1,2 Graduate School, Hanbat National University 125, Dongseo-daero, Yuseong-gu, Daejeon 305-719, Republic of Korea #4 Department of Architectural Engineering, Hanbat National University 125, Dongseo-daero, Yuseong-gu, Daejeon 305-719, Republic of Korea 1 sarahjung92@naver.com 2 withand2@naver.com 4 kwhlee@hanbat.ac.kr * Habitat for Humanity Nepal Office, Dhumbarahi Marg, Kathmandu 44600, Nepal 3 rashmi_manandhar@hotmail.net Abstract Windows are the only part in buildings that can directly penetrate the solar radiation into the space and thus the shading devices are needed to control the solar penetration. Among different blind types in office buildings, optimized control strategies of slat-type blinds are suggested in the existing studies. Although many studies have been done, mostly the study focuses on window that is oriented towards the south. As it is obvious that in a real building windows can be facing any direction, in this study the effect of blinds on heating and cooling loads of a building has been done, when the design of blind is either horizontal or vertical, when it is placed either inside or outside and when the slat angle automatically changes based on either solar energy received on vertical wall or on horizontal surface (roof). Keywords - EnergyPlus; internal blind; external blind; cooling load; heating load; orientation 1. Introduction 1.1 Background and purpose Nowadays, building energy consumption covers 25% of whole energy consumption in Korea [1], and it is growing steadily. So reduction of building energy consumption is very important. But unfortunately many high-rise office buildings in Korea have recently adopted the curtain wall structure, due to aesthetic façade, openness, and light-weight construction [2]. As the curtain wall structure is made with glass, the curtain wall has higher U-value than masonry wall, which in turn increases cooling and heating load in the building [3]. There are many window types in the building with different solar transmission and U-values, but it is not easy that cope with the external environment. Thus, the shading

system should be selected in order to reduce the energy consumption of buildings. Nowadays commonly used shading system is roll-shade blind. But roll-shade blind have the limited ability to control solar radiation, so a blind system with different shape was developed, that is slat blind. The angle of slats can be changed and controlled for different weather; this is the strong point of slat blind [3, 4]. Many studies have been previously done regarding the various blinds for window systems. G. Dutta [5] used TRNSYS to calculate the thermal performance of a building using external fixed horizontal louvers with different slat length and tilts. She found that properly designed louvers on the south window can reduce the cooling load in summer but optimum design depends on site location and weather condition. A. Tzempelikos et al. [6] suggested that to substantially reduce the cooling and lighting energy demand, it is better to take an integrated approach for automatic control of motorized shading in conjunction with controllable electric lighting systems. In case of Korea, Kim et al. [7] concluded on the basis of experimental results that using automated horizontal blinds can reduce cooling energy consumption as compared with motorized horizontal blinds. M.H Oh et al. [8] made a study on a double sided blind with different reflectance and by optimizing the control strategies, they were able to achieve 29.2% total energy saving with 0.1% chances of glare. Y.B. Yoon et al. [9] did a detailed heat balance analysis using EnergyPlus with horizontal blinds both inside and outside and with various glazing materials to find the different parameters that affect the different components of heat balance [3]. Although very detailed study have been carried out for different shading devices, most of the studies focus on horizontal slat type shading devices, like venetian blinds and roller-type blinds and almost all studies are done for windows/walls facing south orientation. As the western sun is known to cause more glare effect, study on the effect of blinds on other orientation is also relevant. Therefore, the objective of this study is to investigate the heating and cooling load variation caused by the change in slat angle of vertical and horizontal blinds when they are not present or placed either inside or outside the window. The most optimal slat angle for lowest cooling and heating load compromise is analyzed based on the amount of solar energy received on vertical and horizontal building surface like wall and roof [3]. 1.2 Research scope Two small-scale mock-up test units were used to obtain real time data for the validation purpose of the simulation model. The detailed validation process has been described in [10]. The validated EnergyPlus simulation model was rotated for the window to face south, east, west and north, and effect on the heating load and cooling load was investigated for blind location, blind type and slat reflectance. Thermal and visible properties of the window materials are based on the J and A glass manufacturing companies in South Korea [3]. 2. Simulation outline 2.1 Simulation software

The simulation program used in this study was EnergyPlus developed by the United States Department of Energy (DOE). It is a relatively new building energy simulation program, which has greater capabilities than other programs [11]. EnergyPlus was selected because it is a heat balance based simulation program and the heat balance method is the current industry standard method for calculating space loads [12]. The blind optical model in EnergyPlus is based on Simmler's model [13]. 2.2 Simulated modeling The schematic overview of EnergyPlus simulation model is illustrated in Fig. 1, which is identical to the measurement. It is south-oriented and thermal properties of PVC and insulation material are based on ISO 10456-2007 [14]. The specifications of the modelled blind are summarized in Table 2. As discussed earlier, the validation process of the simulation model will not be discussed in this paper due to the fact that they are provided in [15] in detail [3]. Blind details 2.3 Simulation conditions Fig. 1 Simulated Model [3] Table 2. Specifications of simulated blind Contents Value Front Reflectance 0.45 Back Reflectance 0.45 Slat Separation 0.025m Slat Width 0.025m Blind to Glass Distance 0.025m Slat Thickness 0.002m Slat Conductivity (W/m K) 0.9 The weather data of Daejeon, South Korea used for the simulation was obtained from Meteonorm program. EnergyPlus recommends the use of Meteonorm weather data if it is not directly provided by EnergyPlus official webpage [16]. The weather in Daejeon is characterized as having four distinct seasons, with hot and humid summer

and cold winter. The peak internal load levels are summarized in Table 3, which are based on ASHRAE Standard 90.1 2007b [17]. The indoor temperature set-points for heating and cooling were set at 22 and 26, respectively, based on the General Design Criteria of ASHRAE handbook HVAC Applications -2007a [18]. The thermal load profiles were calculated using the EnergyPlus function ZoneHVAC:IdealLoadsAirSystem [19] without modelling the heating and cooling systems [12][16][17]. This object provides the required supply air capacity to each zone at user specified temperature and humidity ratio to calculate the heating and cooling loads [3, 20]. Internal Gain Set Temperature Table 3. Input conditions of internal heat gain and indoor set-point [3] Input data 1person (Sensible: People 65W/person, Latent: 54W/person), Lighting Equipment Cooling Heating 10.8 W/ m2 11 W/ m2 25 (May~Sep.) 22 (Oct.~Mar.) Reference SI Unit Air conditioning equipment. (Author : Shin, Chi Woong) ASHRAE handbook Fundamentals (2005) ASHRAE Standard 90.1(2007b) ASHRAE handbook HVAC Applications (2007a) The simulation model was rotated so that the windows were facing south, east, west and north. The effect of vertical and horizontal slat type blinds on cooling and heating load inside the building was investigated where the blind was situated inside and outside the window. The control of slat angle according to zone transmitted solar [3]. 3. Simulation analysis 3.1 Optimal slat angle for South Table 4 shows optimum slat angles for different ranges of zone transmitted solar for lowest cooling and heating load in the south. Zone transmitted solar value was divided into 100 lux unit, cooling and heating marked as C and H respectively. The optimum slat angle for different ranges of zone transmitted solar is constant at 90 (close) for cooling purpose and but for heating purpose, during most of the time it is 0 (open) and changes as the ranges go over 800 lux but these angles are still quite small. This case is similar for both horizontal and vertical blinds [3].

Table 4. South orientation optimum slat angle for various ranges of zone transmitted solar for the lowest cooling and heating load [3]. Zone Transmitted Solar Optimum Slat Angle lux Ver_In Ver_Out Hor_In Hor_Out C H C H C H C H 0-100 90 0 90 0 90 0 90 0 100-200 90 0 90 0 90 0 90 0 200-300 90 0 90 0 90 0 90 0 300-400 90 0 90 0 90 0 90 0 400-500 90 0 90 0 90 0 90 0 500-600 90 0 90 0 90 0 90 0 600-700 90 0 90 0 90 0 90 0 700-800 90 0 90 0 90 0 90 0 800-900 90 0 90 0 90 10 90 0 900-1000 90 10 90 0 90 10 90 0 1000-90 20 90 0 90 20 90 0 3.2 Optimal slat angle for East Table 5 shows optimum slat angles for different ranges of zone transmitted solar for lowest cooling and heating load in the east. Zone transmitted solar value was divided into 100 lux unit, cooling and heating marked as C and H respectively. In case of cooling load, for both horizontal and vertical blinds, for different ranges of zone transmitted solar, the slat angle is constant at 90. But in case of heating load, the vertical blinds have a smaller slat angle when they are inside as compared to when they are positioned inside the window. But in case of horizontal blinds, the slats should be at 0, i.e. fully open, except when the zone transmitted solar is over 700 lux in case of internal blinds [3]. Table 5. East orientation optimum slat angle for various ranges of zone transmitted solar for the lowest cooling and heating load [3]. Zone Transmitted Solar lux Optimum Slat Angle Ver_In Ver_Out Hor_In Hor_Out C H C H C H C H 0-100 90 30 90 40 90 0 90 0 100-200 90 30 90 35 90 0 90 0 200-300 90 35 90 35 90 0 90 0 300-400 90 35 90 35 90 0 90 0 400-500 90 30 90 35 90 0 90 0 500-600 90 20 90 40 90 0 90 0 600-700 90 10 90 50 90 0 90 0 700-800 90 0 90 45 90 20 90 0

800-900 90 0 90 45 90 10 90 0 900-1000 90 0 90 45 90 20 90 0 1000-90 0 90 35 90 30 90 0 3.3 Optimal slat angle for West Table 6 shows the best slat angle for different ranges of zone transmitted solar for lowest cooling and heating load in the west. Zone transmitted solar value was divided into 100 lux unit, cooling and heating marked as C and H respectively. It is almost identical to the east orientation condition. In case of cooling load, for both horizontal and vertical blinds, for different ranges of zone transmitted solar, the slat angle is constant at 90. But in case of heating load, the vertical blinds have a smaller slat angle when they are inside as compared to when they are positioned inside the window. But in case of horizontal blinds, the slats should be at 0 or fully open except when the zone transmitted solar goes over 500 lux in case of internal blinds. Here when the blinds are inside, comparing the vertical and horizontal, the cases flip at 500 lux [3]. Table 6. West orientation optimum slat angle for various ranges of zone transmitted solar for the lowest cooling and heating load [3]. Zone Transmitted Solar lux Optimum Slat Angle Ver_In Ver_Out Hor_In Hor_Out C H C H C H C H 0-100 90 30 90 40 90 0 90 0 100-200 90 30 90 35 90 0 90 0 200-300 90 30 90 30 90 0 90 0 300-400 90 20 90 30 90 0 90 0 400-500 90 10 90 30 90 0 90 0 500-600 90 0 90 40 90 10 90 0 600-700 90 0 90 45 90 20 90 0 700-800 90 0 90 50 90 20 90 0 800-900 90 0 90 45 90 20 90 0 900-1000 90 0 90 45 90 20 90 0 1000-90 0 90 40 90 20 90 0 3.4 Optimal slat angle for North Table 7 shows the best slat angle for different ranges of zone transmitted solar for lowest cooling and heating load for north orientated window. Zone transmitted solar value was divided into 100 lux unit, cooling and heating marked as C and H respectively. Here, for least cooling load the slats need to be completely closed and for least heating load, the slats need to be completely opened when the zone transmitted solar is taken into account [3].

Table 7. North orientation optimum slat angle for various ranges of zone transmitted solar for the lowest cooling and heating load [3]. Zone Transmitted Solar Optimum Slat Angle lux Ver_In Ver_Out Hor_In Hor_Out C H C H C H C H 0-100 90 0 90 0 90 0 90 0 100-200 90 0 90 0 90 0 90 0 200-300 90 0 90 0 90 0 90 0 300-400 90 0 90 0 90 0 90 0 400-500 90 0 90 0 90 0 90 0 500-600 90 0 90 0 90 0 90 0 600-700 90 0 90 0 90 0 90 0 700-800 90 0 90 0 90 0 90 0 800-900 90 0 90 0 90 0 90 0 900-1000 90 0 90 0 90 0 90 0 1000-90 0 90 0 90 0 90 0 3.5 Optimal position of blind for minimized thermal loads The following Fig. 2 shows cooling and heating energy inside the building when there is no blind and if there is blind, what is the effect of blind on the loads. Blind was controlled to be installed at an optimum angle for each of the value. In case of South, the vertical blind located on the exterior is the best option for lowest thermal energy requirement. East case also, the best position is when the blind is on the outside. For the horizontal blind, the total energy demand is 1461.62 kwh and for the vertical blind is 1453.60 kwh. It is similar for west oriented window. The total energy demand difference between horizontal and vertical blind is 6.09 kwh, such that the vertical blind is better than horizontal one. North shows the cooling and heating energy different blind conditions for north oriented window, which is similar to the south oriented window. Surprisingly, the total energy demand for the north oriented window is higher than the south oriented window by about 200 kwh. In this case also the exterior vertical blind causes the least energy demand on the building. In case of cooling load, for all cases window orientation and blind location, the load is minimum when the slat angle is 90, which means the blind is closed and there is no solar gain. For least amount of cooling load there should be no solar heat gain at all. But this also means that there will be no daylighting possible as well. In case of heating load, the slat angle is either 0 or very small, only up to 35 in case of vertical blinds. This means the blinds need to be either completely open or mostly open to decrease heating load [3].

4. Conclusions Fig. 2 Cooling and Heating energy for different blind locations [3] In this study, the various slat angle for lowest heating and cooling load for horizontal and vertical blinds for inside and outside of south, east, west and north oriented windows as done. The heating and cooling loads were calculated for zone transmitted solar, i.e. the slat angle is controlled by the amount of solar angle received from the window. The following conclusions were drawn from this research. Without consideration of lighting, the results found here are very straightforward. For reduction of cooling load the slats needs to be closed, so that there is no solar gain and they need to be open, so there is maximum solar gain for lowest heating load [20]. When the slat angle is controlled based on solar energy received on vertical surface, the lowest cooling load is observed when the blinds are positioned outside. And this also ultimately contributes to less overall load. For lowest total thermal load, horizontal blind is best for south, east and north but vertical blind is better for west [20]. When the slat angle is controlled based on solar energy received on horizontal surface, the slat angle increases as the as the solar energy increases, but the drawback for this control type is that it is the same for all orientations. Since this strategy also considers dimming control, the total load in this system is higher. As the solar energy received on different orientation varies, this control cannot be very reliable [20]. Acknowledgment

This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (2015R1A1A1A05000964). References [1] Energy Statistics Yearbook (Korea Energy Economics Institute, Eiwang, Gyeonggi-do, Korea, 2010). [2] D. S. Kim, Building energy performance assessment of slat type external blind coupled to a box type double skin facade, Final Thesis Report, Masters in Architecture Engineering, Hanbat National University, South Korea (2013). [3] Y. B. Yoon, R. Manandhar and K. H. Lee, Analysis of the indoor thermal load variations depending on the shading device parameters and window orientation, International Journal of Air-Conditioning and Refrigeration (2015), Vol. 23 Issue 3, pp. 1550023-1 ~ 1550023-16 [4] M. H. Oh, Optimum automated control strategies of inside slat-type blind considering visual comport and building energy performance, Final Thesis Report, Masters in Architecture Engineering, Hanbat National University, South Korea (2012). [5] G. Dutta, Effect of fixed horizontal louver shading devices on thermal performance of building by TRNSYS simulation, Renewable Energy (2001), Vol. 23 Issue 3-4, pp. 497 507. [6] A. Tzempelikos and A. K. Athienitis, The impact of shading design and control on building cooling and lighting demand, Solar Energy (2007), Vol.81 Issue 3, pp. 369-382. [7] J. H. Kim, Y. J. Park, M. S. Yeo and K. W. Kim, An experimental study on the environmental performance of the automated blind in summer, Building and Environmet (2009), Vol. 44 Issue 7, pp. 1517 1527. [8] M. H. Oh, K. H. Lee and J. H. Yoon, Automated control strategies of inside slat-type blind considering visual comfort and building energy performance, Energy and Buildings (2012), Vol. 55, pp. 728-737. [9] Y. B. Yoon, D. S. Kim and K. H. Lee, Detailed heat balance analysis of the thermal load variations depending on the blind location and glazing type, Energy and Buildings (2014), Vol. 75, pp. 84-95. [10] Y. B. Yoon, D. S. Kim, J. W. Park and K. H. Lee, A study on the building energy performance depending on the blind location, blind operation and glazing type, Journal of Architectural Institute of Korea (2013), Vol. 7, pp. 309 316. [11] D. Crawley, L. Lawrie, F. Winkelmann, W. Buhl, H. Huang, C. Pedersen et al., EnergyPlus: Creating a new-generation building energy simulation program, Energy and Buildings (2001), Vol. 33 Issue 4, pp. 319 331. [12] ASHRAE, ASHRAE Handbook Fundamentals (American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc., Atlanta 2005). [13] H. Simmler, U. Fischer and F. Winkelmann, Solar- Thermal Window Blind Model for DOE-2, Lawrence Berkeley National Laboratory, Simulation Research Group Internal Report (1996). [14] ISO 10456 Building materials and products Hygrothermal properties Tabulated design values and procedures for determining declared and design thermal values (2007). [15] K. C. Yoon and K. S. Kim, An evaluation of energy performance in an office with venetian blinds in summer, Journal of Architectural Institute of Korea (2012), Vol. 28, pp. 285 292. [16] Lawrence Berkeley National Laboratory, Tips & Tricks for Using EnergyPlus, U.S. Department of Energy (2012). [17] ASHRAE, ASHRAE Standard, Energy Standard for Buildings Except for Low-Rise Residential Buildings (American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, 2007). [18] ASHRAE, ASHRAE Handbook-HVAC Applications (American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, 2007). [19] The U. S. DOE, EnergyPlus Input Output Reference, The Encyclopedic Reference to EnergyPlus Input and Output (2011). [20] The U. S. DOE, EnergyPlus Engineering Reference, The Reference to EnergyPlus Calculations (2011).