September 8, MunnWorks, LLC 150 N. Macquesten Parkway Mount Vernon, NY 10550

Similar documents
FINAL REPORT Efficacy of a Cold Plasma System

FINAL REPORT. Bacterial Survival on PURE-LIGHT SANI-LIGHT coated Glass Slides. Order Number: PREPARED FOR. PURE-LIGHT Technologies LLC

Assessment of Antibacterial Efficacy of Goldshield against MRSA and VRE

Test Method for Efficacy of Copper Alloy Surfaces as a Sanitizer

Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces

Study Title Antibacterial Activity and Efficacy of KHG FiteBac Technology Test Substance Using a Suspension Time-Kill Procedure

KILL TIME STUDIES Antimicrobial Activity of Advanced Cellular Silver (ACS) 200 Using Methicillin resistant Staphylococcus aureus (MRSA)

FINAL REPORT. Bacterial Survival on Glass and Laminated Wood Surfaces Exposed to PURE-LIGHT Coated LED Light Bulbs. Order Number:

Study Title Antimicrobial Activity and Efficacy of Seal Shield's Electroclave. Test Method Custom Device Study. Study Identification Number NG7233

ASSESSMENT OF THE MICROBICIDAL ACTIVITY OF AN ACCELERATED HYDROGEN PEROXIDE- BASED FORMULATION (AHP-5) AGAINST VRE AND MRSA

Submitted May 16, May 23, 2014 BY:

Log Reduction & UV Deceptive Advertising

Biocidal Surface Test - Clinell Wipes ~ Project Report Prepared for GAMA Healthcare Ltd ~ Huddersfield Microbiology Services Oct 06

Persistence of Activity of a Hand Sanitizer

Result:COMPLETE Report Date: December 28 th, 2015

Submitted May 16, May 23, 2014 BY:

ANALYTICAL REPORT: Comparison of the Microbial Recovery Efficacy of QI Medical EnviroTest Paddles versus a Conventional Contact Plate

The Efficacy of 300 ppm Peracetic Acid from Perasan MP-2 and MP-2C on E. Coli O157:H7 Inoculated Meat Surfaces

KILL-TIME STUDIES Antimicrobial Activity of EO H 2 O Using Clostridium difficile spores Test Solutions: Acidic H 2 O Submitted December 12, 2011

Alpha HydroMAID Cleaning Effectiveness of the Alpha HydroMAID Cleaning System versus Conventional Mopping

Antimicrobial effectiveness evaluation of Isocide powder coating versus stainless steel plate

The Effect of Air Pockets on the Efficiency of Disinfection of Respiratory Equipment by Pasteurization

Microbial Survival. Created on 2/25/ :05 AM

Dryflex. Antimicrobial TPEs

Guidelines for Laboratory Verification of Performance of the FilmArray Blood Culture Identification (BCID) Panel

Protocols for Laboratory Verification of Performance of the FilmArray Blood Culture Identification (BCID) Panel

Analysis of Agion Coated Galvanized Steel Air Ducts in Woodward Academy Middle School after 10 Years of Service

Slate Steel (Mild Steel) Ceramic

Protocols for Laboratory Verification of Performance of the BioFire FilmArray Blood Culture Identification (BCID) Panel

ANTI-BACTERIAL EXECUTIVE SUMMARY

COMPARING THE ANTIMICROBIAL ACTIVITY OF THE SEMCO 3A TOTAL ENERGY WHEEL WITH OTHER SELECTED ANTIMICROBIAL SURFACE TREATMENTS RESEARCH FINDINGS

Impact of Room Location on UV-C Irradiance and UV-C Dosage and Antimicrobial Effect Delivered by a Mobile UV-C Light Device

Indigo-Clean White Paper: #1 Bactericidal Performance Testing of Indigo-Clean Upon Bacterial Species. Healthcare

ANTIMICROBIAL FLOORING FACTS...

ENVR 421 Laboratory #1: Basic Bacteriology Techniques

DID YOU KNOW? Acquired Infections (HAI s) reported every year!

Decontamination Effectiveness of Esco Celsafe CO2 Incubator Sterilization Feature using High Heat Temperature By Bekti Tri Sumaryati

Test Method of Specified Requirements of Antibacterial Textiles for Medical Use FTTS-FA-002

Biological Consulting Services of North Florida, Inc.

Biological Consulting Services of North Florida, Inc.

Biological Consulting Services of North Florida, Inc.

Document No. FTTS-FA-001. Specified Requirements of Antibacterial Textiles for General Use

Isolation and Characterization of Two Antibiotic-Producing Bacteria

HELP CONTROL E-COLI, SALMONELLA, & MRSA

Join the movement to continuously kill bacteria.

Published Standards ISO General instructions for microbiological examination ISO Enumeration and detection of aerobic mesophilic bacteri

Biological Consulting Services of North Florida, Inc.

COMPARITIVE STUDY OF THE EFFECT OF SINGLE WALLED CARBON NANOTUBES ON Escherichia coli IN CULTURES AND BIOFILMS. A write-up on the proposed Study

Method Suitability Report Membrane Filtration Sterility Test with QTMicro Apparatus

IN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing

3 Petrifilm Environmental Listeria Plate for the Rapid Enumeration of Listeria from Environmental Surfaces

KILL-TIME STUDIES Antimicrobial Activity of Experimental Solutions Using Legionella pneumophila Test Solution: ACS 200 Submitted June 6, 2012

FINAL REPORT LOW LEVEL DISINFECTION EVALUATION VIOGUARD KEYBOARD

TECHNICAL DATASHEET. in compliance with: USP, ISO and all appropriate subsections FQ 106 v3.0 August, 2015

3M Condensation Management Film (CMFi) Hygienic Evaluation of

HARDWARE MADE WITH BACTERICIDAL COPPER

Copper alloys were selected to cover an object was based on its ability to be fabricated and/or surfaced

Biological Consulting Services of North Florida, Inc.

Dealer Bulletin. Re: OPTIM 33TB; 3 Minute Fungicidal Claim. OPTIM 33TB Contact Times* To: All Authorized SciCan Dealers Canada

Bacterial inactivation claims in the context of sterility. Adonis Stassinopoulos, Ph.D V.P. Global Scientific Affairs and Research Cerus Corporation

á62ñ MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: TESTS FOR SPECIFIED MICROORGANISMS

Hospital Acquired Infections The Problem

Laboratory Testing of Zebra s Z-Band Direct Thermal Wristbands with Antimicrobial Coating

Effects of Raspberry Juice on Microbial Flora. Max O Malley Grade 9 Central Catholic High School

Cleaning Efficiency of The MicroOne Wipe and Mop Cleaning System

Some Industrially Important Microbes and Their Products

Chapter 9 Antimicrobial Susceptibility Testing (Agar Disk Diffusion Method)

Microgen and Airocide Technology as a Method for Sterilization in ICU: A Comparative Study

This study report is published with the express written consent of Antimicrobial Test Laboratories. Business Mobility Now!

MICROBIOLOGICAL EXAMINATION OF NON-STERILE PRODUCTS: TEST FOR SPECIFIED MICRO-ORGANISMS Test for specified micro-organisms

Final text for addition to The International Pharmacopoeia

Glass microscope slides treated/coated with Sani-Shield were supplied by the Unelko Group.

Research Project for Zimek Technologies, LLC

Study Title Determination of the Antiviral Effectiveness of KHG FiteBac Technology Test Substance Delivered via Pipette Against MS2 Bacteriophage

Disinfecting Microbes with Crystal IS Klaran UVC LEDs

Formula One-Step Coating Solvent-Based For Difficult Materials

Standard Operating Procedure Title: Stock Suspensions of Micro-Organisms

ORIGINAL ARTICLE. H.T. Michels 1, J.O. Noyce 2 and C.W. Keevil 2. Abstract

tel: fax: foodcheksystems.com

21.4 Recombinant DNA technology Calculation worksheet. AQA Biology. Calculating the efficiency of DNA transfer during genetic engineering

ELISA for Alpha-hemolysin (Hla) in Methicilin-resistant Staphylococcus aureus (MRSA) Varandt Y. Khodaverdian 1* and Menachem Shoham 2

Isolation of Host Specific Bacteriophages against Salmonella and Methicillin Resistant Staphylococcus aureus (MRSA) From Hospital Waste Water

Antimicrobial Lab Test Report

NEIlON LABORATORY FINAL REPORT TIME KILL STUDY PROCEDURE NO. STP0158 REV 01 PROTOCOL DETAIL SHEET NO REV 01

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

CLENDO INDUSTRIAL LABORATORY. CUSTOMER SAMPLE ANALYSIS REPORT Page1 of 8. FDA No CLENDO CONTROL NO. 9081, 9095

New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765

Study Title Antibacterial Efficacy of Bio-Care Technology's Non-Porous Test Substance

Aqua 65JL. Water-Based Hydrophilic Coating. Highly Lubricious, Non-Eluting, surface coating for the reduction of biofilm adhesion.

INTRODUCTION Sanitization sterilization Antibiotics Bactericidal Bacteriostatic Antiseptics disinfectants

LAB NOTES FOR EXAM 1 SECTION

2.1 Tryptone Soya Broth containing 4% Tween 80 (TSB + T), or another appropriate deactivating broth.

Immobilization and Death of Bacteria by Flora Seal Microbial Sealant

Sample for Use as a Guide Revised IDEXX ENTEROLERT TEST METHOD FOR THE DETECTION OF ENTEROCOCCI IN WATER

Efficacy of Peracetic Acid from Perasan MP-2 against non-o157:h7 Pathogenic Escherichia coli

Room Decontamination with UV Radiation

Antibiotic Susceptibility Testing (ABST/AST)

COUNT METHOD 5.0 OBJECTIVES 5.1 INTRODUCTION 5.2 PRINCIPLE. Structure

Rapid Detection of Bacterial Growth in Blood Cultures by Bioluminescent Assay of Bacterial ATP

1. Procedure for Antibiotic susceptibility test by disc diffusion analysis

Transcription:

September, 2017 To: Max Munn MunnWorks, LLC 150 N. Macquesten Parkway Mount Vernon, NY 10550 From: Matthew Hardwick, PhD ResInnova Laboratories 07 Colesville Rd, 3 rd Floor Silver Spring, MD 20910 Dear Mr. Munn, Enclosed you will find the summary analysis report for the recent antimicrobial testing of two UV-emitting mirror prototypes. The wall-mounted mirrors were tested for their ability to kill three healthcare-relevant bacteria: Clostridium difficile spores (C diff), Escherichia coli (E coli), and methicillin-resistant Staphylococcus aureus (MRSA). Testing occurred over several time points and samples were placed in various locations on a vanity/sink. Within this report, you will find the graphs summarizing the data. A great deal of data was generated during the course of this project that did not end up in this report. All data is available for your review should you request it. The conclusions drawn from this project are listed on the last page of this report. Please notify me if you wish additional testing of this material and/or further analysis of the results contained within this report. Sincerely, Matthew Hardwick, PhD President and CEO

2 Final Report Purpose We performed antimicrobial testing of two UV-emitting mirror prototypes. The wall-mounted mirrors were tested for their ability to kill three healthcare-relevant bacteria: Clostridium difficile spores (C diff), Escherichia coli (E coli), and methicillin-resistant Staphylococcus aureus (MRSA). Testing occurred over several time points and samples were placed in various locations on a vanity/sink. The goals of this project were: 1. Determine the antimicrobial efficacy of the mounted UV LEDs against C diff spores, E coli, and MRSA; 2. Determine the optimal operating conditions to kill logs (99.99%) of each bacterium. Materials and Methods UV-emitting Mirrors (provided by MunnWorks) Prototype 1 with a UV LED strip mounted parallel to the bottom of the mirror and recessed from the bottom of the mirror. A UV LED strip was also mounted inside the mirror. Prototype 2 with a UV LED strip mounted flush with the bottom of the mirror at an approximate 5 angle facing away from the mirror. Bacteria Clostridium difficile (C diff) spores (ATCC BAA-170) Escherichia coli (E coli) (ATCC 25922) Methicillin-resistant Staphylococcus aureus (MRSA) (ATCC 33591) Bacterial Sample Preparation: C diff: Approximately 1 x 10 6 spores were plated onto magnetic steel discs and allowed to dry. E coli and MRSA: A thin layer of tryptic soy agar was plated onto magnetic steel discs and allowed to dry. Then, approximately 1 x 10 6 colony forming units (CFUs) were layered on top of the agar. o The agar layer was necessary as plating E coli and MRSA directly onto magnetic steel discs resulted in poor bacterial recovery. Sample placement: Samples were placed on several locations on a vanity/sink. See Figure 1 for placement and overall setup. Bacterial Recovery and Evaluation: At the indicated time points, discs were recovered into a labeled 15ml tube containing 10ml phosphate-buffered saline (PBS) + 0.1% Trion X-100 and vortexed for 1 minute. 0.1ml of the recovery solution was then transferred either onto agar plates (see below) or into dilution tubes for further dilution. Agar plates were then incubated for 2 to. Log reductions were determined by comparing colony numbers from test samples to control samples (samples not exposed to UV). o C diff: brain heart infusion agar with incubation in an anaerobic chamber at 37 C. o E coli and MRSA: tryptic soy agar with incubation in a humidified chamber at 37 C.

3 Figure 1: Testing Setup and Sample Placement Results We tested the bacteria killing ability of two MunnWorks UV-emitting mirror prototypes. The first prototype we received demonstrated robust reduction of spore viability on backsplash surfaces. The compiled results after testing of both prototypes are presented in Figure 2. After one exposure, reductions approached 3 logs (99.9%) and surpassed logs (99.99%) after 2 (Figure 2, Backsplash). This first prototype, however, had several deficiencies as it failed to reduced spore viability on faucet handles and on surfaces greater than 7 inches from the light source. It was decided by MunnWorks to create a new prototype based on these results and we discontinued testing on the first prototype. The second prototype increased the reach of the UV achieving a 2.9 log reduction of C diff spores on the sink side edges (the rim of the sink approximately 1 inches away from the light source) after 2. The second prototype also improved UV exposure to faucet handles achieving greater than log spore reductions were seen after just 1 and 3.5 log reductions were seen at the sink drain after 2 of exposure. This prototype also showed a 3.56 log reduction in spores at the sink drain (no reductions were seen in the first prototype). No reductions were seen in the sink at points immediately adjacent to the sink wall proximal to the UV source or on the distal sink edge (data not shown). This prototype also failed to deliver adequate UV to the backsplash (data not shown). We were also able to test the ability of the second prototype to kill both E coli and MRSA. Testing against E coli demonstrated greater than log reductions for both faucet handles and the drain after just 30 min (Figure 3). Regardless of how long we exposed the sinks to UV, the mirror failed to produce greater than a 1.9 log reduction on the edges of the sink (approximately 1 inches from the UV source). For the faucet handles and sink drain, MRSA results were similar to E coli, with greater than log reductions seen within an of exposure to UV (Figure ). On the sink side edges, however, MRSA demonstrated a greater than log reduction after an of UV exposure. For neither E coli or MRSA were bacterial reductions seen in the sink at points immediately adjacent to the sink wall proximal to the UV source or on the distal sink edge (data not shown).

Figure 2: UV Reduction of C diff Spore Recovery on Vanity/Sink Surfaces Backsplash Faucet Handles 5.00.00 Drain Side Edges Figure 3: UV Reduction of E coli Recovery on Vanity/Sink Surfaces Faucet Handles Drain 5.65 5.60 5.55 5.50 Side Edges 1.90 1.0 1.70 1.60 1.50 1.0

5 Figure : UV Reduction of MRSA Recovery on Vanity/Sink Surfaces Faucet Handles Drain Side Edges 5.00 Discussion There were several anomalous results during testing. Several data points seen in Figures 2 and 3 show that longer UV exposures do not improve bacterial reduction outcomes. This phenomenon is particularly true at the drain and sink edges for all three organisms. It should be noted that a major failing of all UV technologies is shadowing. For our simulated sink testing (Figure 1) we used a rotating faucet. It is possible that, for the drain test points, the faucet may have been moved relative to the position of our test sample resulting in a shadow effect that reduced the UV exposure at that test point. The sink we used for testing has beveled edges. Any shifting in the position of the sink edge test samples may have resulted in a dramatic effect on the UV exposure to the sample (another example of shadowing). Shadowing, however, does dramatically limit the utility of this technology on surfaces immediately adjacent to the sink wall proximal to the UV source and to surfaces greater than 22 inches from the UV source (data not shown). Regardless, there is ample evidence that significant bacterial reductions are achieved at critical areas such as the backsplash, faucet handles, drain and sink edges.

6 Conclusions The first prototype demonstrated dramatic C diff spore reductions on backsplash samples: o Backsplash > logs after 2 exposure. The second prototype demonstrated dramatic reductions with C diff spores, E coli, and MRSA on several critical sink areas: o Faucet Handles C diff spores: > logs after 1 exposure; E coli: > logs after 30 minute exposure; MRSA: > logs after 30 minute exposure. o Drain C diff spores: > 3 logs after 2 exposure; E coli: > logs after 30 minute exposure; MRSA: > logs after 30 minute exposure. o Side Edges C diff spores: almost 3 logs after 2 exposure; E coli: almost 2 logs after 1 exposure; MRSA: almost 2 logs after 1 exposure. A 2 non-stop operation of the UV-emitting mirror should have a dramatic antimicrobial effect on the bathroom vanity/sink area. Future prototypes that provide at least 2 UV LED units (1 placed as on prototype 1 and the other placed as on prototype 2) should provide adequate coverage of most areas of the bathroom vanity and sink. o Exceptions include the sink wall proximal to the UV LED units and areas greater than 22 inches distal to the UV LED units. More testing is needed to conclusively determine the effect of the UV-emitting mirrors on organisms other than C diff, E coli and MRSA. o However, it may be reasonably assumed that the mirrors should be effective against other Gram-negative bacteria, such as Legionella pneumophila, and Gram-positive bacteria, such as Streptococcus species.