To: Firm: Project: Product Specified: Specified Location:

Similar documents
DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: KWIK BOLT TZ MASONRY ANCHORS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

*Corrected October 2005

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

CITY OF LOS ANGELES CALIFORNIA

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW BUILDEX 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

ESR ICC Evaluation Service, Inc. Issued March 1, 2006 This report is subject to re-examination in one year.

CALIFORNIA ERIC GARCETTI MAYOR

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.1.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 17.

The following excerpt are pages from the North American Anchor Fastening Technical Guide, 2011.

ESR ICC Evaluation Service, Inc. Reissued January 1, 2008 This report is subject to re-examination in one year.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Hilti, Inc South 122 nd East Avenue Tulsa, OK

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

ICC-ES Evaluation Report. ESR-3342 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code.

ESR-2713 Reissued August 1, 2013 This report is subject to renewal September 1, 2014.

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC SOUTH 122 ND EAST AVENUE TULSA, OKLAHOMA 74146

ESR-2202 Issued May 1, 2009 This report is subject to re-examination in one year.

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INTALLED CONCRETE ANCHORS

LEGACY REPORT ER-5608* Reissued February 1, Legacy report on the 1997 Uniform Building Code

ESR-2269 Reissued November 1, 2008 This report is subject to re-examination in one year.

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW RED HEAD 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

CITY OF LOS ANGELES CALIFORNIA

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

Trusted ICC ES HILTI, INC. SYSTEM E ANCHOR. Conformity! Look. Evaluation. ICC-ES Evaluation

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: MITEK USA, INC.

ESR-2036 Reissued May 1, 2013 This report is subject to renewal June 1, 2015.

FROM: PROPOSED SUBSTITUTION: Use HILTI X-U instead of fillet weld or arc spot puddle weld

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Trusted ICC ES CONCRETE SECTION: SECTION: 05 HILTI, INC. Look. Conformity! ICC-ES Evaluation

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

Hilti, Inc South 122 nd East Avenue Tulsa, OK

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal May 1, 2015

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

ESR ICC Evaluation Service, Inc. Reissued September 1, 2008 This report is subject to re-examination in one year.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

CITY OF LOS ANGELES CALIFORNIA

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS DIVISION: CONCRETE ANCHORS REPORT HOLDER: DEWALT

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST-INSTALLED CONCRETE ANCHORS

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

CITY OF LOS ANGELES CALIFORNIA

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 100 PLANO, TEXAS 75024

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

FROM: SUBJECT: HILTI X-ENP-19, X-HSN 24 or X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST

CITY OF LOS ANGELES CALIFORNIA

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CAST-IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: HILTI, INC.

ICC-ES Evaluation Report Reissued January 1, 2012 This report is subject to renewal in one year.

CITY OF LOS ANGELES CALIFORNIA

Trusted ICC ES HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC.

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALED CONCRETE ANCHORS

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES REPORT HOLDER: NELSON STUD WELDING, INC WEST RIDGE ROAD ELYRIA, OHIO 44036

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

CITY OF LOS ANGELES CALIFORNIA

where: P s = Applied service tension load, pounds (kg). P t V s V t

DIVISION: CONCRETE SECTION: CONCRETE ANCHORS DIVISION: METALS SECTION: POST INSTALLED CONCRETE ANCHORS

Transcription:

Submittal Substitution Request To: Firm: Project: Product Specified: Specified Location: Attached information includes product description, installation instructions and technical data needed for review and evaluation of the submittal request. Submitted By: Name: Signature: Firm: Address: Phone: Email: Fax: Submittal Date: For Architect / Engineer Use: Reviewed, Accepted ~ No Exceptions: Make Corrections as Noted: Revise and Resubmit: Rejected: Brief explanation for corrections needed, revisions needed or why rejected:

Mechanical Anchoring Systems.. KWIK HUS-EZ (KH-EZ) Carbon Steel Screw Anchor... Product Description...2 Material Specifications... Technical Data...4 Installation Instructions... Ordering Information Listings/Approvals ICC-ES (International Code Council) ESR-027 (Cracked & Uncracked Concrete) AC 0 ESR Pending (Grout filled concrete masonry) City of Los Angeles Research Report No. 2897 Independent Code Evaluation IBC / IRC 2009 (AC 9 / ACI.2) IBC / IRC 200 (AC 9 / ACI.2) IBC / IRC 200 (AC 9 / ACI.2)... Product Description Hilti KWIK HUS-EZ (KH-EZ) anchors are comprised of a body with hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.000 inch (8 μm) zinc coating in accordance with DIN EN ISO 4042. The KWIK HUS-EZ (KH- EZ) system is available in a variety of lengths with diameters of /4 inch, /8 inch, /2 inch, /8 inch and /4 inch (.4mm, 9.mm, 2.7mm,.9mm and 9.mm). The hex head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete lightweight concrete over metal deck, and grout filled concrete masonry. Guide Specifications Screw anchors shall be KWIK HUS-EZ as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8μm. Anchor head shall display name of manufacturer, product name, diameter and length. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product Features Length and diameter identification clearly stamped on head facilitates quality control and inspection after installation. Through fixture installation improves productivity and accurate installation. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size and uses standard diameter drill bits. Suitable for reduced edge distances and spacing....2 Material Specifications Hilti KWIK HUS-EZ anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8μm.... Technical Data The data contained in Tables - of this section have been evaluated in accordance with AC 9. For more detail, see ICC-ES ESR 027. Figure KWIK HUS-EZ anchor installation details Suitable for cracked and uncracked normal weight and lightweight concrete, and grout filled concrete masonry. Suitable for seismic and nonseismic loads. Quick and easy to install. 280 Hilti, Inc. (US) -800-879-8000 www.us.hilti.com I en español -800-879-000 I Hilti (Canada) Corp. -800--448 I www.hilti.ca I Anchor Fastening Technical Guide 20

Mechanical Anchoring Systems.. KWIK HUS-EZ (KH-EZ) Carbon Steel Screw Anchor Table Allowable Tension Loads for KWIK HUS-EZ Installed in Grout-Filled Masonry Walls (lb),2,7,8 Anchor Diameter /4 /8 /2 /8 /4 Embedment Loads @ C cr and S cr Critical - S cr 4 Spacing Minimum - S min 4 Load Reduction Factor at S min /8 0 2 0.70 4 2 /2 90 4.00 /8 4 2 0.70 2 /2 89 /4 20 2 /4 70 4 2 0 4 /4 /4 7 4 80 /4 20 4 0.80 8 4 Critical - C cr Edge Distance Minimum C min Load Reduction Factor 4 4.00 4 4.00 0.0 4 4.00 0 4 0.0 0 4.00 2 4 0.0 2 4.00 Table 7 Allowable Shear Loads for KWIK HUS-EZ Installed in Grout-Filled Masonry Walls (lb),2,7,8 Anchor Diameter /4 /8 /2 /8 /4 Embedment Load at C cr and S cr Critical - S cr 4 Spacing Minimum - S min 4 Load Reduction Factor at S min Critical - C cr Minimum - C min Edge Distance Load Reduction Factor at C min Load Direction Load Direction Perpendicular Parallel to Edge to Edge /8 7.00.00 4 4.00 4 4 2 /2 840.00.00 /8 40 0..00 2 /2 4 0.94 4 0.70.00 /4 90 0.70.00 2 /4 84 0.0.00 20 8 4 0.88 8 4 0.4 0.94 4 /4 274 0.40 0.89 /4 040 0. 0.82 0 4 0. 0 4 48 0.4 0.92 4 040 0. 0.82 0 4 0. 2 4 /4 48 0.4 0.92 All values are for anchors installed in fully grouted masonry with minimum masonry prism strength of 00psi. Concrete masonry units shall be light-weight or normal-weight. 2 Anchors may not be installed within one inch in any direction of a vertical joint. Embedment depth is measured from the outside face of the concrete masonry embedment. 4 S cr is anchor spacing where full load values in the Table may be used. S min is the minimum anchor spacing for which values are available and installation is recommended. Spacing is measured from the center of one anchor to the center of an adjacent anchor. C cr is the edge distance where full load values in the table may be used. C min is the minimum edge distance for which values are available and installation is recommended. Edge distance is measured from the center of the anchor to the closest edge. Load reduction factors are multiplicative, both spacing and edge distance load reduction factors must be considered. Load values for anchors installed at less than C cr or S cr must be multiplied by the appropriate load reduction factor based on actual edge distance (C) or spacing (S). 7 Linear interpolation of load values between minimum spacing (S min ) and critical spacing (S cr ) and between minimum edge distance (C min ) and critical edge distance (C cr ) is permitted. / / T applied V applied T applied V 8 For combined loading: For /4" diameter - + For /8" - /4" diameter - + T allowable ( applied V allowable T allowable V allowable ( ) ) 28 Hilti, Inc. (US) -800-879-8000 www.us.hilti.com I en español -800-879-000 I Hilti (Canada) Corp. -800--448 I www.hilti.ca I Anchor Fastening Technical Guide 20

Mechanical Anchoring Systems KWIK HUS-EZ (KH-EZ) Carbon Steel Screw Anchor.. Table 8 KWIK HUS-EZ Allowable Loads Installed In Top of Grout-Filled Concrete Masonry Construction (lb) Anchor Diameter Minimum Embedment Depth 2 Minimum Edge Distance Minimum Spacing Minimum End Distance Tension Perpendicular to Edge of Masonry Wall Shear Parallel to Edge of Masonry Wall /2 4 /4 /4 8 4 80 0 0 /8 /4 0 0 0 All values are for anchors installed in fully grouted masonry with minimum masonry prism strength of 00psi. Concrete masonry units shall be light-weight or normal-weight. 2 Embedment depth is measured from the top of the masonry construction. T applied For combined loading: For /4" diameter - + For /8" - /4" diameter - + T allowable ( V allowable T allowable V applied V allowable ( ) T applied / ) V applied /...4 Installation Instructions Drill holes in base material using carbide-tipped masonry drill bits complying with ANSI B22.-994. The nominal drill bit diameter must be equal to that of the anchor. The minimum drilled hole depth is given in Table. Prior to installation, dust and debris must be removed from the drilled hole using a hand pump, compressed air or a vacuum. The anchor must be installed into the predrilled hole using a powered impact wrench or installed with a torque wrench until the proper nominal embedment depth is obtained. The impact wrench torque, T impact and installation torque, T inst for the manual torque wrench must be in accordance with Table. The KWIK HUS-EZ (KH-EZ) may be loosened by a maximum of one turn and reinstalled with a socket wrench or powered impact wrench to facilitate fixture attachment or realignment. For member thickness and edge distance restrictions for installations into the soffit of concrete on steel deck assemblies, see Figure 2. Drill hole in base material using proper diameter drill bit. Clean drilled hole to remove debris.! Fasten anchor tightly against fastened part. Install anchor using proper impact tool or torque wrench. Hilti, Inc. (US) -800-879-8000 www.us.hilti.com I en español -800-879-000 I Hilti (Canada) Corp. -800--448 I www.hilti.ca I Anchor Fastening Technical Guide 20 287

Mechanical Anchoring Systems.. KWIK HUS-EZ (KH-EZ) Carbon Steel Screw Anchor... Ordering Information Order Information Description Hole Diameter Total Length without Anchor Head Minimum Embedment Depth Qty (pcs) / Box KH-EZ /4"x-7/8" /4" -7/8" -/8" 00 KH-EZ /4"x2-/8" /4" 2-/8" 2-/2" 00 KH-EZ /4"x" /4" " 2-/2" 00 KH-EZ /4"x-/2" /4" -/2" 2-/2" 00 KH-EZ /4"x4" /4" 4" 2-/2" 00 KH-EZ /8"x-7/8" /8" -7/8" -/8" 0 KH-EZ /8"x2-/8" /8" 2-/8" -/8" 0 KH-EZ /8"x" /8" " 2-/2" 0 KH-EZ /8"x-/2" /8" -/2" 2-/2" 0 KH-EZ /8"x4" /8" 4" -/4" 0 KH-EZ /8"x" /8" " -/4" 0 KH-EZ /2"x2-/2" /2" 2-/2" 2-/4" 0 KH-EZ /2"x" /2" " 2-/4" 0 KH-EZ /2"x-/2" /2" -/2" " 2 KH-EZ /2"x4" /2" 4" " 2 KH-EZ /2"x4-/2" /2" 4-/2" 4 /4" 2 KH-EZ /2"x" /2" " 4 /4" 2 KH-EZ /2"x" /2" " 4-/4" 2 KH-EZ /8"x-/2" /8" -/2" -/4" KH-EZ /8"x4" /8" 4" -/4" KH-EZ /8"x-/2" /8" -/2" -/4" KH-EZ /8"x-/2" /8" -/2" -/4" KH-EZ /8"x8" /8" 8" -/4" KH-EZ /4"x4-/2" /4" 4-/2" 4" 0 KH-EZ /4"x-/2" /4" -/2" 4" 0 KH-EZ /4"x7" /4" 7" 4" 0 KH-EZ /4"x8" /4" 8" 4" 0 KH-EZ /4"x9" /4" 9" 4" 0 290 Hilti, Inc. (US) -800-879-8000 www.us.hilti.com I en español -800-879-000 I Hilti (Canada) Corp. -800--448 I www.hilti.ca I Anchor Fastening Technical Guide 20

ICC-ES Evaluation Report www.icc-es.org (800) 42-87 (2) 99-04 ESR-0 Issued October, 202 This report is subject to renewal October, 20. A Subsidiary of the International Code Council DIVISION: 04 00 00 MASONRY Section: 04 0 9. Masonry Anchors REPORT HOLDER: HILTI, INC. 400 SOUTH 22 ND EAST AVENUE TULSA, OKLAHOMA 744 (800) 879-8000 www.us.hilti.com HiltiTechEng@us.hilti.com EVALUATION SUBJECT: HILTI KWIK HUS-EZ (KH-EZ) CARBON STEEL SCREW ANCHORS FOR USE IN MASONRY.0 EVALUATION SCOPE Compliance with the following codes: 202, 2009, 200 and 200 International Building Code (IBC) 202, 2009, 200 and 200 International Residential Code (IRC) Property evaluated: Structural 2.0 USES The Hilti KWIK HUS-EZ (KH-EZ) screw anchors are used to resist static, wind and seismic tension and shear loads in grout-filled concrete masonry units. The Hilti KWIK HUS-EZ screw anchors are alternatives to anchors described in Section 207 of the IBC (TMS 402) for concrete masonry construction. The Hilti KWIK HUS-EZ screw anchors are permitted to be used in structures regulated by the IRC, provided an engineered design is submitted in accordance with IRC Section R0....0 DESCRIPTION. KWIK HUS-EZ: Hilti KWIK HUS-EZ (KH-EZ) screw anchors are comprised of a threaded body with hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.000-inch (8 μm) zinc coating in accordance with DIN EN ISO 4042. The anchoring system is available in a variety of lengths with diameters of inch, inch, / 2 inch, inch, and inch (.4 mm, 9. mm, 2.7 mm,.9 mm and 9. mm). The KWIK HUS-EZ (KH-EZ) is illustrated in Figure. The hex head is larger than the anchor diameter and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the base material on the sides of the hole and interlock with the base material during installation. Product information is found in Table, installation parameters are found in Table 2 and described in Section 4.2, and the Manufacturers Published Installation Instructions (MPII) are depicted in Figure 4..2 Grout-filled Concrete Masonry: The compressive strength of masonry, f m at 28 days must be a minimum of,00 psi (0. MPa). Fully grouted masonry walls must be constructed from the following materials:.2. Concrete Masonry Units (CMUs): CMUs must be minimum Grade N, Type ll, lightweight, medium-weight, or normal-weight conforming to ASTM C90. The minimum size of the CMU must be a nominal 8 inches wide by a nominal 8 inches high by a nominal inches long..2.2 Grout: Grout must comply, as applicable, with 202 IBC Section 20., 2009 and 200 IBC Section 20.2, 200 IBC Section 20.0, or IRC Section R09... Alternatively, the grout must have a minimum compressive strength, when tested in accordance with ASTM C09, equal to its specified strength but not less than 2,000 psi (.8 MPa)..2. Mortar: Mortar must be Type M or S in compliance, as applicable, with 202 IBC Section 20.9, 2009 and 200 IBC Section 20.8, 200 IBC Section 20.7, or IRC Section R07. 4.0 DESIGN AND INSTALLATION 4. Allowable Stress Design: 4.. General: Anchors described in this report are assigned allowable tension and shear loads for designs based on allowable stress design (ASD). 4..2 Design of Anchors Installed in Uncracked Grout-filled Concrete Masonry: Allowable tension and shear loads for anchors installed in the face of uncracked grout-filled masonry are noted in Tables and 4. The allowable tension and shear loads are for anchors installed in the grouted cells, the center web of concrete masonry units and horizontal mortared bed joints of fully grouted CMU construction. Allowable loads for anchors installed within inches (2 mm) of the vertical (head) joint, as ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 202 Page of 000

ESR-0 Most Widely Accepted and Trusted Page 2 of depicted in Figure 2, are beyond the scope of this report. Critical and minimum spacings and edge distances are given in Table 2. Allowable load reduction factors for anchors installed at reduced spacing and reduced edge distances (between critical and minimum) are noted in Table and Table 4. Allowable tension and shear loads for / 2 -inch and -inch (2.7 mm and.9 mm) anchors installed in the top of uncracked fully grouted concrete masonry walls are noted in Table. Separate values are given for shear loads towards the edge and parallel to the edge of the masonry wall. Allowable loads for anchors installed within inches (2 mm) of the head joint are beyond the scope of this report. Allowable loads for anchors installed in uncracked groutfilled masonry subjected to combined tension and shear loads must be determined by the following equations: +.0 for all diameters installed in the top of the wall / + /.0 for all diameters installed in the face of the wall where: P s = Applied service tension load P t = Allowable service tension load V s = Applied service shear load V t = Allowable service shear load 4.2 Installation Installation parameters are provided in Tables 2,, 4 and, and Figures 2, and 4. Anchor locations must comply with this report and with plans and specifications approved by the code official. The Hilti KWIK HUS-EZ (KH-EZ) must be installed according to this report and the manufacturer s published instructions (MPII) as depicted in Figure 4. In case of conflict, this report governs. Anchors must be installed into base material perpendicular to the surface using carbide-tipped masonry drill bits complying with ANSI B22.-994. The nominal drill bit diameter must be equal to that of the anchor. The minimum drilled hole depth is given in Table 2. Prior to installation, dust and debris must be removed from the drilled hole using a hand pump, compressed air or a vacuum. The anchor must be installed into the predrilled hole using a powered impact wrench or with a torque wrench until the proper nominal embedment depth is obtained. The maximum impact wrench torque and the maximum installation torque for a manually calibrated torque wrench must be in accordance with Table 2. 4. Special Inspection: Anchors must be installed with special inspection. For the IBC and IRC, special inspection must conform to Sections 704 and 70 of the IBC. For fasteners installed with special inspection, the following items, as applicable, must be inspected: fastener type, diameter and length; masonry dimensions and compliance with ASTM C90; grout and mortar compliance with standards listed in Section.2, and, where required, masonry prism compressive strength; drill bit diameter and compliance with ANSI B22.2-994; and fastener embedment, spacing, and edge distance. The special inspector must verify that anchor installation complies with this evaluation report and the manufacturer s published installation instructions..0 CONDITIONS OF USE The Hilt KWIK HUS-EZ Screw Anchors described in this report are suitable alternatives to what is specified in the codes listed in Section.0 of this report, subject to the following conditions:. Anchors are identified and installed in accordance with this report and the manufacturer s published installation instructions. In case of conflict, this report governs..2 Anchors resisting static, seismic or wind load in groutfilled concrete masonry must be designed in accordance with Section 4. of this report.. When using the basic load combinations in accordance with IBC Section 0.., allowable loads are not permitted to be increased for seismic or wind loading. When using the alternative basic load combinations in IBC Section 0..2 that include seismic or wind loads, the allowable shear and tension capacities for anchors included in this report may be increased by / percent, or the alternative basic load combinations may be multiplied by a factor of 0.7..4 Since an ICC-ES acceptance criteria for evaluating data to determine the performance of screw anchors subjected to fatigue or shock loading is unavailable at this time, the use of these anchors under these conditions is beyond the scope of this report.. Where not otherwise prohibited by the applicable code, anchors are permitted for use with fireresistance-rated construction provided that at least one of the following conditions is fulfilled: Anchors are used to resist wind or seismic forces only. Anchors that support fire-resistance-rated construction or gravity load bearing structural elements are within a fire resistance-rated envelope or a fire-resistance-rated membrane, are protected by approved fire-resistance-rated materials, or have been evaluated for resistance to fire exposure in accordance with recognized standards. Anchors are used to support nonstructural elements.. Since an ICC-ES acceptance criteria for evaluating the performance of screw anchors in cracked masonry in unavailable at this time, the use of anchors is limited to installation in uncracked masonry. Cracking occurs when f t > f r due to service loads or deformations..7 Prior to installation, calculations and details demonstrating compliance with this report must be submitted to the building official for approval. The calculations must be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed..8 Special inspection must be provided in accordance with Section 4...9 Anchors are limited to dry, interior use..0 Anchors must be installed in holes predrilled in masonry as described in this report, using drill bits in compliance with ANSI B22.-994.. The KWIK HUS-EZ screw anchors are manufactured by Hilti AG, under a quality control program with inspections by UL LLC (AA-8).

ESR-0 Most Widely Accepted and Trusted Page of.0 EVIDENCE SUBMITTED. Data in accordance with the ICC-ES Acceptance Criteria for Predrilled Fasteners (Screw Anchors) in Masonry (AC0), dated May 202; including tests for seismic qualification, edge distance and spacing, and installations for top of fully grouted CMU masonry wall construction..2 Quality control documentation. 7.0 IDENTIFICATION The HILTI KWIK HUS-EZ (KH-EZ) anchors are identified by packaging with the manufacturer s name (Hilti, Inc.) and contact information, anchor name, anchor size, evaluation report number (ESR-0), and the name of the inspection agency (UL LLC, AA-8). The anchors have KH-EZ, HILTI, and the anchor diameter and anchor length embossed on the anchor head. Identifications are visible after installation, for verification. FIGURE HILTI KWIK HUS-EZ SCREW ANCHOR TABLE KWIK HUS-EZ (KH EZ) PRODUCT INFORMATION DESCRIPTION NAME AND SIZE DIAMETER TOTAL LENGTH UNDER THE ANCHOR HEAD KH-EZ "x 7 " 7 KH-EZ "x2 " " 2 " KH-EZ "x" " KH-EZ "x / 2 " " / 2 " KH-EZ "x4" " 4" KH-EZ "x 7 " " 7 " KH-EZ "x2 " " 2 " KH-EZ "x" " " KH-EZ "x / 2 " " / 2 " KH-EZ "x4" " 4" KH-EZ "x" " " KH-EZ / 2 "x2 / 2 " / 2 " 2 / 2 " KH-EZ / 2 "x" / 2 " " Screw Anchor with KH-EZ / 2 "x / 2 " / 2 " / 2 " Hex-Head KH-EZ / 2 "x4" / 2 " 4" KH-EZ / 2 "x4 / 2 " / 2 " 4 / 2 " KH-EZ / 2 "x" / 2 " " KH-EZ / 2 "x" / 2 " " KH-EZ "x / 2 " " / 2 " KH-EZ "x4" " 4" KH-EZ "x / 2 " " / 2 " KH-EZ "x / 2 " " / 2 " KH-EZ "x8" " 8" KH-EZ "x4 / 2 " " 4 / 2 " KH-EZ "x / 2 " " / 2 " KH-EZ "x7" " 7" KH-EZ "x8" " 8" KH-EZ "x9" " 9"

ESR-0 Most Widely Accepted and Trusted Page 4 of TABLE 2 KWIK HUS-EZ (KH-EZ) INSTALLATION INFORMATION AND ANCHOR SPECIFICATION,2,,4 INSTALLATION DETAIL UNITS NOMINAL ANCHOR DIAMETERS / 8 / 2 Drill Bit Diameter Minimum Baseplate Clearance Hole Diameter in. in. / 2 Maximum Installation Torque ft-lbf 2 22 4 8 70 Maximum Impact Wrench ft-lbf 4 4 4 2 2 2 2 2 2 2 Torque Rating Minimum Nominal Embedment Depth in. 2 / 2 2 4 / 2 4 Minimum Hole Depth in. 2 2 7 7 / 2 2 4 4 Critical Edge Distance in. 4 8 0 2 Minimum Edge Distance in. 4 Critical Spacing Distance in. 4 8 0 2 Minimum Spacing Distance in. 4 Wrench Socket Size in. 7 / 9 / / 2 7 / Values in this table are to be used in conjunction with load values contained in Tables, 4, and, and the appropriate figures in this report, with the exception of the minimum spacing, edge, and end distances for anchors installed in the top of grout filled concrete masonry, which are listed in Table. 2 Critical spacings and edge distances are the anchor spacing and edge distances for which no reduction in load capacity is required. Minimum spacings and minimum edge distances in this report are the smallest values for which anchor installation is allowed. 4 Anchors may be installed anywhere in the fully grouted masonry wall except within inch of a vertical joint (see Figure 2). Maximum Installation Torque applies to installations using a calibrated torque wrench. Because of the variability in measurement procedures, the published torque of an impact tool may not correlate properly with the above setting torques. Over-torquing can damage the anchor and/or reduce its holding capacity. TABLE ALLOWABLE TENSION LOADS FOR KWIK HUS-EZ IN THE FACE OF GROUT-FILLED MASONRY WALLS (POUNDS),, ANCHOR DIAMETER EMBEDMENT 2 ALLOWABLE TENSION LOADS FOR IBC/IRC CRITICAL C CR EDGE DISTANCE C MIN LOAD REDUCTION FACTOR 4 CRITICAL S CR SPACING S MIN LOAD REDUCTION FACTOR 4 424 7 4 4.00 4 4.00 2 / 2 728 8 / 8 428 8 4.00 4 0.80 98 2 / 4 / 2 8 4.00 8 4 0.0 4,22 / 4 924 0 4.00 0 4 0.7,88 4, 2 4.00 2 4 0.,28 Anchors shall be installed in base materials in compliance with Section.2 of this report. 2 Embedment depth is measured from the outside surface of the concrete masonry unit. Refer to Section. of this report for modifying allowable loads in this table for anchors resisting short-term loads. 4 Allowable loads are based on installation at critical spacing and edge distance. Load reduction factors are applicable at the minimum spacing and edge distance. Linear interpolation of reduction factors is allowed for spacings and edge distances between critical and minimum. Tabulated allowable loads for the IBC/IRC are based on a safety factor of.0. Special inspection must be provided in accordance with Section 4. of this report. 7 Load values for installations within inch of bed joint for " diameter at inch embedment shall be reduced by 2%. 8 Load values for installations within inch of bed joint for inch diameter at 2 / 2 inch embedment and inch diameter at inch embedment shall be reduced by %.

ESR-0 Most Widely Accepted and Trusted Page of ANCHOR DIAMETER EMBEDMENT 2 TABLE 4 ALLOWABLE SHEAR LOADS FOR KWIK HUS-EZ INSTALLED IN THE FACE OF GROUT-FILLED MASONRY WALLS (POUNDS),, SHEAR LOADS at C CR AND S CR SPACING EDGE DISTANCE ALLOWABLE SHEAR LOADS FOR IBC/IRC CRITICAL S CR S MIN LOAD REDUCTION FACTOR 4 CRITICAL C CR C MIN LOAD DIRECTION PERPENDICULAR TO EDGE LOAD DIRECTION PARALLEL TO EDGE 2.00 4 4.00 4 4 2 / 2 0.00.00 92 0. 4 0.94 4 92 0.70.00 / 2 2 47 0.0 8 4 0.88 8 4 4 99 0.40.00 242 0. 0 4 0.2 0 4 27 0.4.00 4 242 0. 2 4 0. 2 4 27 0.4.00 Anchors shall be installed in base materials in compliance with Section.2 of this report. 2 Embedment depth is measured from the outside surface of the concrete masonry unit. Refer to Section. of this report for modifying allowable loads in this table for anchors resisting short-term loads. 4 Allowable loads are based on installation at critical spacing and edge distance. Load reduction factors are applicable at the minimum spacing and edge distance. Linear interpolation of reduction factors is allowed for spacings and edge distances between critical and minimum. Tabulated allowable loads for the IBC/IRC are based on a safety factor of.0. Special inspection must be provided in accordance with Section 4. of this report. ANCHOR DIAMETER TABLE ALLOWABLE TENSION AND SHEAR LOADS FOR KWIK HUS-EZ INSTALLED IN THE TOP OF GROUT-FILLED CONCRETE MASONRY CONSTRUCTION,,4,, EMBEDMENT DEPTH 2 EDGE DISTANCE SPACING END DISTANCE TENSION (POUNDS) PARALLEL TO EDGE OF MASONRY WALL SHEAR (POUNDS) LOAD DIRECTION PERPENDICULAR TO EDGE OF MASONRY WALL / 2 4 8 8 40 88 24 0 0 04 90 24 Anchors shall be installed in base materials in compliance with Section.2 of this report. 2 Embedment depth is measured from the outside surface of the concrete masonry unit. Refer to Section. of this report for modifying allowable loads in this table for anchors resisting short-term loads. 4 See Figure for details of anchor location in top of CMU wall. Additionally, anchors shall be installed with a minimum 4-inch distance to the head joint. Tabulated allowable loads for the IBC/IRC are based on a safety factor of.0. Special Inspection must be provided in accordance with Section 4. of this report.

ESR-0 Most Widely Accepted and Trusted Page of Anchor Installation is Restricted to Shaded Areas FIGURE 2 ACCEPTABLE LOCATIONS (SHADED AREAS) FOR HILTI KWIK HUS-EZ ANCHORS IN GROUT-FILLED CONCRETE MASONRY FIGURE EDGE AND END DISTANCES FOR THE KWIK HUS-EZ ANCHORS INSTALLED IN THE TOP OF CMU MASONRY WALL CONSTRUCTION FIGURE 4 INSTALLATION INSTRUCTIONS HILTI KWIK HUS-EZ (KH-EZ)