NATURAL VENTILATION STRATEGIES FOR COMMERCIAL BUILDINGS

Similar documents
CI/SfB (57.7) Xy Uniclass Ss_65_40_33_56 June 2017 U-VALUE IMPROVED BY 22 % AIRCOOL VENTILATORS ...

AIRCOOL VENTILATORS FURTHER INFORMATION

CI/SfB (57.7) Xy Uniclass Ss_65_40_33_56 March 2018 U-VALUE IMPROVED BY 22 % AIRCOOL VENTILATORS HYBRID PLUS2 AIRCOOL NEW ...

Natural Ventilation in Schools and Commercial Buildings (CPD No. 31) Issue 2 May 2017

ROOF VENTILATION TERMINALS

For all those with the ability to influence the design, layout or indoor air quality of buildings

NATURAL VENTILATION COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

BRE Energy Efficient Office of the Future

Work Package 2: Performance of naturally ventilated buildings

Leeds Metropolitan University Portland Gate Development - Phase 1 Building Building Sustainability Design Statement

THE INSTITUTE OF REFRIGERATION

ACOUSTIC VENTILATION SYSTEMS FOR NEW HOUSING

Wind-Driven Natural Ventilation Systems. PRESENTED BY NIRAJ MISTRY

PROVIDING ADEQUATE NATURAL VENTILATION WITHIN LIVESTOCK BUILDINGS

BUILDING INTEGRATED VENTILATION SYSTEMS MODELLING AND DESIGN CHALLENGES

ARCHITECTURAL QUALITY AND SUSTAINABILITY

Potential of natural ventilation in shopping centres

REFURBISHMENT OF AIR-CONDITIONED BUILDINGS FOR NATURAL VENTILATION

Work Package 2: Performance of naturally ventilated buildings

Parkview Green, Beijing Microclimatic envelope

PCM s in application for acclimatization of buildings. Nick Barnard, Faber Maunsell VSK2008, Workshop on heat storage

Chapter 7. Passive Solar Contents

Monitoring of Advanced Facades and Environmental Systems

Thermal comfort in a 21st century climate

Cold Plane Innovative Method for Humidity Condition Control

SOUTH LANARKSHIRE COLLEGE LOW CARBON TEACHING BUILDING TECHNICAL CASE STUDY

Information Guide Long Term Efficiency. Issue 42

10 tips from your Architect

Sustainability. Good Sustainable Design requires understanding combined with vision; it is attainable through architect-led design.

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec Existing external wall construction

BUILDING SIMULATION AS AN ASSISTING TOOL IN DESIGNING AN ENERGY EFFICIENT BUILDING: A CASE STUDY

Potential of Natural Ventilation in Shopping Centres Diederichsen, Alice; Friis, Kristina; Brohus, Henrik; Tranholm, Gitte T.

Natural ventilation and low energy building design

Evaluating Appropriate Residential Ventilation Strategies in Dense Urban Environments and the Challenges for Passive Design

The Low Energy Ventilation Company. Fiona Dickinson, Consulting Engineer 21 st May 2013

Cattle Housing and Ventilation

INFLUENCES OF LIGHTING CONTROL AND NATURAL VENTILATION ON ENERGY USE AND OVERHEATING FOR A DAY-LIT INDUSTRIAL BUILDING

CHAPTER 13: Sustainability

The Top Five Ways an Architect Can Drive Sustainability. Early-stage design decisions that can have a significant impact on building performance

Residential Modelling using CIBSE TM59 with Case Studies

Project Description. Projected build start date 03 May 2010 Projected date of occupation 06 Aug

546: High Altitude Design, Optimising Residential Architecture in the Alborz Mountains, Iran

L2A 2010 In 30 Minutes!!

Evaluation of natural ventilation systems in a landscaped office.

Designing Institutions for the Future Greening Education Conference 1 st May 2013 Andrew Parkin BEng(Hons) CEng FIOA FIHEEM

What is Sustainable Design?

Energy Efficient and Good Indoor Climate in Buildings

Tage Møller Architect office building

MODELLING AND MONITORING SUMMER PERFORMANCE OF BEAUFORT COURT

Cost-Benefit Analysis of Dwelling Retrofit Options

Efficient cooling in a natural and energy-saving way. Large volume flows of outside air provide cooling. Intelligent control

Ventilation Approaches for Shopping Malls An Examination of Natural and Hybrid Strategies

Design for Indoor Environmental Quality in schools

Project Description. Projected build start date 12 Apr 2010 Projected date of occupation 28 Feb

Advanced Ventilation Technologies

3/20/2013. Project logo

The feasibility of natural ventilation in plus energy houses in Germany

Radical POTENTIAL!! COMFORT ZONE WHAT IS IT? WHAT DOES IT HAVE TO DO WITH GREEN BUILDING + ZERO CARBON?

Building the Future for Care Homes

Advanced Ventilation Technologies

An introduction to our Windvent natural ventilation units. Designed for use in commercial applications.

Design and retrofitting of a hybrid building in Athens

General guidelines for using thermal mass in concrete buildings

IESVE Compliance for ASHRAE IES Virtual Environment

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

Advanced Ventilation Technologies

Low2No Implementation of sustainable principles after design competition

Project Description. Projected build start date 19 Apr 2010 Projected date of occupation 30 Sep

The case for research

Energy Statement. Gainsford Road. For Pocket Living. XCO2 energy. May 2016

BESPOKE DESIGN BY JET COX LTD

Built for sustainability Built for the environment Built for fuel efficiency Built for life

New Rules for Mariana Trusson

Winner of CIBSE Building Performance Award Project of the Year (Public use) 2017 Keynsham Civic Centre

ADVANCED FAÇADES AND HVAC SYSTEMS: PRELIMINARY RESULTS OF FULL-SCALE MONITORING

The Hive Sustainability Trail - Supporting Notes

Chapter 2 Literature Review

Achieving Zero Carbon for Buildings in a Densely Populated City and a Subtropical Climate. Guiyi LI Construction Industry Council

Introduction to basics of energy efficient building design

Energy Performance Certificate

Work Package 2: Performance of naturally ventilated buildings

BRE: Ventilation and overheating in multi residential buildings Are they linked?

SUSTAINABLE DESIGN STRATEGIES FOR BUILDING DESIGNERS

The Good, The Bad & The Ugly

DISPLACEMENT VENTILATION

Sustainability - incorporated in lightweight construction. Aarhus School of Architecture 15. november 2011

Designing carbon neutral schools: The Victor Miller Building, a critical review

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

LITTLEPITS PASSIVHAUS PLUS

PASSIVENT PASSIVE STACK VENTILATION SYSTEMS IPSV INTELLIGENT PASSIVE STACK VENTILATION SYSTEM

CIBSE LOW CARBON CONSULTANTS REGISTER SESSION 10 ENERGY EFFICIENCY IN BUILDINGS. I Prophets energy services

Project Description. Projected build start date 01 May 2010 Projected date of occupation 01 Nov Belfast, County Antrim, Northern Ireland

HUMAN-BEHAVIOR ORIENTED CONTROL STRATEGIES FOR NATURAL VENTILATION IN OFFICE BUILDINGS

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 01 Aug Energy target.

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 7 Heiselberg, Per Kvols. Publication date: 2016

Passive Strategies and Low-Carbon Technologies: Evaluating the Energy Performance and Thermal Comfort of a Passive House Design

EVALUATION OF VENTILATION STRATEGIES TO REDUCE OVERHEATING IN A TYPICAL METAL CLAD BUILDING WITH IN- PLANE ROOF-LIGHTS

Transcription:

CI/SfB (57) Uniclass L7535 September 2015 NATURAL VENTILATION STRATEGIES FOR COMMERCIAL BUILDINGS................................

.................................................................................. NATURAL VENTILATION..................................................................................................... The low-energy strategy Low-energy natural ventilation is an increasingly important design strategy for commercial and other non-domestic buildings. In comparison with air conditioning or mechanical ventilation it can bring: Economic benefits through savings in both capital equipment and running costs. Environmental benefits in reducing energy use and cutting greenhouse gas emissions and CO 2 levels. User benefits in providing controlled, comfortable conditions. Intelligent solutions Current technology and design software combined with sophisticated control systems mean that natural ventilation can provide optimum performance as well as the benefits indicated above. Using the latest techniques, intelligent natural ventilation solutions can be applied to many buildings that would otherwise have defaulted to air conditioning. Hybrid Plus systems can also be used for pre-warming incoming air in winter periods by mixing air and in summer months, they create airflow in times of low air movement. Early consultation The key to the successful implementation of a natural ventilation strategy is to consider its application during the preliminary stages in the design of a building (preferably at outline proposal stage). Decisions about building plan, orientation and other factors will enable the most effective use to be made of natural ventilation. Clients, developers and building designers should therefore consult natural ventilation experts such as Passivent as early as possible in the design process. PASSIVENT Passivent services Designing natural ventilation systems to be as efficient as possible requires specialised expertise. With its in-house research and design team, Passivent can provide a comprehensive design and advisory service tailored to specific projects, covering both system design and product selection from a range of complementary ventilation strategies. Passivent expertise Passivent are specialists in delivering natural ventilation solutions, and a leading UK company in the field of sustainable and energy-efficient ventilation for commercial buildings. A pioneer in natural ventilation, Passivent has been at the forefront in developing innovative products and systems to provide optimum performance in all types of buildings. A range of natural daylighting products including tubular rooflights, modular rooflights and combined rooflight/ventilators complements Passivent s natural ventilation range. Passivent design software With so many variables in natural ventilation design it is important to understand how the elements interact with each other within the context of the building. A key part of the NatVent research project (see overleaf) has been the production of software to assess the various forms of natural ventilation in different types of building. Following on from this Passivent has developed its own advanced software AirSoft (based on CIBSE AM10) to provide an integrated design approach that takes account of all facets of the ventilation requirement. This software is used to calculate sizes of air inlets and outlets to achieve optimum performance. Passivent products Passivent has developed a range of products (including acoustically treated and hybrid plus options) which can be incorporated into natural ventilation systems for commercial buildings. More information on these is available on request. Passivent Products are also embedded within EDSL s TAS programme for ease of thermal modelling. 2...................................................................................................

................................................. THE BACKGROUND................................................................... The NatVent TM project NatVent TM was an EC/EU-funded project involving nine partners in seven countries, co-ordinated by the UK Building Research Establishment and published during 1999. Passivent, as one of the NatVent TM partners, has taken a leading role in developing practical solutions for the commercial building sector. Passivent have been providing solutions to clients since. The NatVent TM group has carried out an indepth study of natural ventilation and found that it is an effective design strategy for office buildings in the UK and other European countries with a moderate climate. Benefits The many benefits of naturally ventilated buildings identified by the NatVent TM project include: Cost efficiency Naturally ventilated buildings typically consume less than half the energy used in air-conditioned buildings. Initial capital costs are also lower, typically by 15%. Operating costs can be 40% less in terms of energy consumption. Due to simplicity and durability of the components, costs are spread over a longer lifetime. Maintenance costs are significantly lower. Less space is required for plant rooms and services distribution. Productivity gains 90% of building occupants prefer naturally ventilated buildings. Fewer incidents of sick building syndrome are reported. Occupants are provided with control over their immediate environment. CO 2 reduction 50% of CO 2 emissions in the UK derive from energy consumption in buildings. All buildings, both new and refurbished, must use energy more efficiently to reduce environmental damage. Energy Performance Certificates (EPCs) have been introduced to help improve the energy efficiency of buildings. Building Regulations Approved Document L Conservation of fuel and power includes performance targets for CO 2 emissions. System design Good design is based on the principle that adequate ventilation is essential for the health, safety and comfort of building occupants, but that excessive ventilation leads to energy waste and discomfort. Building tightness, good ventilation for occupants and natural ventilation design should be considered together for a successful energy-efficient natural ventilation scheme, as set out in Building Regulations. Strategies have to be developed for winter and summer often requiring different products and control logic. Winter ventilation to maintain good indoor air quality must be balanced against minimising heat losses. Summer ventilation must offset excessive daytime heat gains and provide fresh air distribution. Environmental gains Significant reduction in emissions of the greenhouse gas carbon dioxide (CO 2 ). Avoids using ozone-depleting substances as refrigerants. Since 1999, Passivent have continuously developed our solutions, whilst sticking to the findings of this project.................................................................... 3

........................................................................................... NATURAL VENTILATION STRATEGIES... Background ventilation is necessary to provide adequate indoor air quality throughout the year. This can be achieved by various types of façade mounted controllable ventilators often controlled by internal CO 2 levels. Rapid ventilation is necessary to remove excess temperature from the space and is of prime importance during the summer. Cross ventilation Cross ventilation achieves good air change rates driven by pressure differences across the building. This method uses controllable high-capacity inlets/outlets on two opposing building façades, and can achieve penetration depths of up to 5 times the floor-to-ceiling height. Single-sided ventilation Single-sided ventilation, usually through large façade opening devices, is mainly driven by wind turbulence. Relatively low ventilation rates are achieved except with penetration depths of less than 2 1 2 times the floor-to-ceiling height. Penetration depths are based on typical office low occupant densities and are not applicable to higher occupant densities such as teaching spaces and seminar rooms. Hybrid Plus versions of single sided ventilation systems are available to prewarm incoming air in winter and assist with airflow during the warmer summer months. Mixed-mode ventilation Natural ventilation alone may not be suitable for some rooms due to their depth, internal heat loads or other factors. In these cases some mechanical assistance can be incorporated e.g. low powered boost fans in outlets or local comfort cooling devices. 4...

.............................................................................................................. Passive stack ventilation Passive stack ventilation (PSV) is the most effective natural ventilation strategy as it uses a combination of cross ventilation, buoyancy and the suction effect as the wind passes the terminal. It can ventilate to twice the depth of cross ventilation, up to 10 times the floor-toceiling height, as the outlet can be in the centre of a building. It can be an effective night cooling strategy as internal and external temperature differences at night are typically high, so increasing convection. PSV stacks can range from large central atria to local stacks feeding to roof-mounted terminals. Hybrid Plus versions of passive stack ventilation systems are available to pre-warm incoming air in winter and assist airflow during the warmer summer months. Displacement ventilation Displacement ventilation uses wind driven roof-mounted terminals with separated chambers to channel air down into the building regardless of wind direction. The cooler, denser air displaces warmer, lighter air upwards, which is drawn out through the leeward chambers of the terminals. This method can be used as part of a night cooling strategy. Night cooling Night cooling uses the lower external temperatures at night to reduce the temperature of the building fabric, by means of automatic ventilation devices. The cooled thermal mass of the building is used the next day to reduce internal temperatures. It is best suited to heavy weight structures. A night cooling strategy in a suitable building design can reduce peak internal temperatures by 2-3ºC the following day. Natural night cooling by lowering the ambient temperatures can delay the use of energy consuming cooling equipment. SYSTEM CONTROL An efficient and effective natural ventilation system should move air through the building in a carefully designed manner. The sizing and positioning of inlets, stacks and outlets are critical in achieving the correct ventilation performance. Control of systems is also important to ensure maximum effectiveness and provide the correct level of ventilation at minimum energy cost. Control components are available from Passivent that vary from simple occupant controlled devices to intuitive systems triggered by sensors which detect temperature and CO 2, matching ventilation to demand. These can be integrated with an overall building management system (BMS) via our intelligent controls system...... 5

......................................................................... SUSTAINABLE BUILDING DESIGN... Sustainability can be best defined as improving the quality of life for all without damaging the environment or the ability of future generations to meet their own needs Vision 21. Sustainable buildings will encompass all facets of design but include natural ventilation, optimum use of daylighting, high thermal mass, solar shading, improved levels of insulation, use of renewable/ recyclable materials and effective lighting controls. It is important that all members of the design team sign up to the achievement of a common project environmental policy, which acknowledges a commitment to maximise the environmental potential within reasonable constraints. Guidance documents such as BREEAM can lead a project to produce a successful and sustainable green building. The generic project illustrated opposite demonstrates many of the ventilation and daylight considerations required to achieve a sustainable building. Ground and First Floor Ventilation (illustrations 1 and 2 opposite) The inlet path for natural ventilation is via openable high-level façade devices and windows. The high level openings allow fresh air to pass into the ceiling void and then into the space below. This strategy provides cooling of the structure at night during summer months as well as tempering incoming air the next day. In winter this eliminates sources of draughts by opening windows, as the fresh air passing through the ceiling is prewarmed. A degree of external acoustic attenuation is also provided via the ceiling void. The openable windows are used to boost the ventilation rate, whilst providing additional user control of their own environment. The façade and ceiling outlet louvres are insulated, so closure at night and during the morning warm-up period reduces heat loss, during cooler periods. These motorised louvres are controlled automatically with manual override facility, to allow user interface. The room with higher internal heat gains has been located on the lower floor of the North façade as this experiences the lowest solar gains. A boost fan or comfort cooling can be incorporated to provide a mixed mode strategy during warmer weather. The roof-mounted terminals provide large fixed openings with Class-A rain rejection performance and an AA fire rating. Daylighting and Corridor Ventilation (illustration 3 opposite) External southerly solar shading reduces the external solar gains in summer, whilst the building orientation maximises passive heat gain in winter. Tubular rooflights allow natural daylight to enter the rear of the rooms. The reduced window area on the South façade, together with solar control glazing, reduces external heat gains. Daylight control is used with efficient artificial lighting to reduce energy usage. Ventilation of the corridor is achieved using insulated openable façade devices at either end. The air is exausted via high level openings in the glazed façade. These motorised louvres are controlled automatically. 6...........................................................................................

............................................................................................................... Illustration 1 Ground Floor Ventilation N S Illustration 2 First Floor Ventilation N S Illustration 3 Daylighting and Corridor Ventilation N S Illustrations based on a design produced by Stride Treglown Davies.......................................................................................................... 7

................................................................... FURTHER.............. INFORMATION.................................... Operational commitment As part of our commitment to minimising our impact on the environment, and to continuous improvement in our methods of operation, Passivent is accredited to ISO 14001 Environmental Management, OHSAS 18001 Health and Safety Management, and ISO 9001 Quality Management Systems. Environmental responsibility In addition to their energy-efficiency, natural ventilation systems require less maintenance and component replacement than mechanical systems over the life of the building. BPD/Passivent manufacturing processes and raw materials emphasise sustainability. Other products Passivent market a range of ventilation and daylighting products for commercial buildings including: Natural ventilation systems Mixed mode cooling systems Aircool ventilators for windows, curtain walling and walls Airstract roof terminals for passive stack and other natural ventilation systems Airscoop wind-driven ventilation terminals Solar shading systems Sunscoop tubular rooflight systems Litevent combined ventilator and rooflight Metrodome rooflights SoundScoop ventilation systems Background ventilation systems................................................................... PASSIVENT LIMITED North Frith Oasts, Ashes Lane, Hadlow, Kent TN11 9QU Tel: 01732 850770 Fax: 01732 850949 Email: projects@passivent.com Web: www.passivent.com Passivent Limited maintains a policy of continuous development and reserves the right to amend product specifications without notice. A division of Building Product Design Ltd. Company Registration No; 3944123...... 4671