PRODUCT DATA SHEET. Product Description

Pre-applied waterproofing membranes that bond integrally to poured concrete for use below slabs or behind basement walls on confined sites

PRODUCT DATA SHEET. Product Description

Preprufe Plus. Application Manual

PREPRUFE 300R LT & 160R LT

March 2016 Replaces June 2013 Preprufe 160 Sheet Tanking and Waterproofing Membrane

PREPRUFE Plus Low Temperature Membranes

Section Pre-Applied Sheet Membrane Waterproofing

PREPRUFE 300R Plus & 160R Plus

Student Services & Classroom Addition

Fosroc Proofex Engage

SYSTEM 500 NEWTON. System 400 NEWTON 403 HYDROBOND Externally Applied Waterproofing Membrane DATA SHEET MSDS INSTALLATION MANUAL

A. The work of this section includes, but is not limited to, the following:

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

ALLNEX DAMP PROOF AND TANKING MEMBRANES. Product. Scope. Appraisal No. 805 [2013] Appraisal No. 805 (2013) Amended 26 January 2018.

Pre-applied waterproofing

HYDRODUCT Vertical Drainage Sheets

BITUTHENE 3000 and BITUTHENE Low Temperature Below-Grade

Aussie Skin 550. Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane. Delivery, Storage, and Handling

GRACE CONSTRUCTION STRUCTURAL WATERPROOFING MEMBRANES PREPRUFE 160R

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

GRACE CONSTRUCTION STRUCTURAL WATERPROOFING MEMBRANES PREPRUFE 300R PLUS

Aussie Skin 550. Heavy Duty Below Grade, Blind-Side, Under-Slab Waterproofing Membrane. Delivery, Storage, and Handling

RIW SHEETSEAL GR BENEFITS APPLICATIONS APPLIED TO

PRODUCT DATA SHEET SikaProof A

WATERPROOFING. MiraPLY Installation Instructions SCIENCE. SERVICE. SOLUTIONS. Introduction. Description. Substrate Preparation. Features and Benefits

HYDRODUCT Vertical Drainage Sheets

PREPRUFE Low Temperature Membranes

Sheetseal GR RIW. Sheetseal GR

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

Agrément Certificate 03/4042 website: Product Sheet 1 FOSROC MEMBRANES PROOFEX ENGAGE

BITUTHENE Deck System

PRODUCT DATA SHEET. SikaProof A

PRODUCT DATA SHEET SikaProof Bentonite

The Best External Waterproofing For Below Ground Structures

Sheetseal 226 RIW. Sheetseal 226

SikaProof A. Fully bonded FPO sheet membrane waterproofing system for basements and other below ground structures. Product Description

CCW MiraPLY Installation Instructions

PREPRUFE SCS Blindside waterproofing system for shotcrete foundation walls

Start the installation at one corner of the building. Unroll the first sheet of MiraPLY-H square/parallel to the building wall, starting at one corner

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description.

INSTALLATION GUIDELINES PRECON

INSTALLATION GUIDELINES

Visqueen Gas Barrier STRUCTURAL WATERPROOFING AND GAS PROTECTION SYSTEMS. CE Mark to EN 13967

SELF-ADHERING SHEET WATERPROOFING

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components.

PERM-A-BARRIER NPS Detail Membrane

High Performance DPM. Installation. Technical Support: LAST UPDATED: Page 1 CE Mark to EN 13967

EVOH PENETRATIONS INSTALLATION GUIDELINES PERMINATOR PLACEMENT

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Construction. SikaProof A. Fully bonded FPO sheet waterproofing membrane system for basement and other below ground structures. Product Description

PROOFEX ENGAGE Membrane d étanchéité Wasserdichtungsmittel. Regulations

INSTALLATION GUIDELINES

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

PROCOR Composite Waterproofing System

INSTALLATION GUIDELINES - With VaporSeal Tape

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description

ITEM 458 WATERPROOFING FOR STRUCTURES

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

PART 1 GENERAL 1.1 SECTION INCLUDES. A. Below grade waterproofing and dampproofing 1.2 RELATED SECTIONS 1.3 REFERENCES

SIKAPROOF A WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 852 [2014] Appraisal No. 852 (2014) Amended 24 April 2018

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

J41 Reinforced bitumen membrane roof coverings

METHOD STATEMENT Sika Drain-850 Geo

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

GRACE CONSTRUCTION STRUCTURAL WATERPROOFING MEMBRANES PREPRUFE 800PA

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

SECTION FLUID-APPLIED WATERPROOFING

BENTONITE WATERPROOFING SYSTEM FOR STRUCTURES SIKA BENTOSHIELD MAX LM

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

tra-load Tanking Membranes Product and Systems Overview

SECTION 07530CP EPDM MEMBRANE ROOFING

PART 4 - SELF ADHERING WATERPROOFING

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

Installation Instructions ALUTRIX 600 ALUTRIX FR

LIQUID APPLIED WATERPROOF ROOF COATINGS

SikaProof Bentonite Plastic DPM overlap - Compacted Backfill Scale 1:5. Detail no: SB01 - Nov 2013

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Perm-A-Barrier VPS (Vapor Permeable Sheet)

Gas Protection System Components

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description

RIW STRUCTURESEAL. Structureseal is a highly effective waterproofing composite, of high strength green coloured geotextile, and sodium bentonite.

Sarnavap 5000E SA Vapour Control Layer

PLATON FOUNDATION WRAP

LIQUID APPLIED WATERPROOF ROOF COATINGS

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

Evaluation Report CCMC R NUDURA Waterproofing Membrane

BENTONITE WATERPROOFING

J41 Reinforced bitumen membrane roof coverings

PERM-A-BARRIER VPS. Product Description. Product Data Sheets. Self-adhering vapor permeable air and water barrier membrane

LIQUID APPLIED WATERPROOF ROOF COATINGS

KIM Best Practices Guide for Shotcrete Nov 2013

Advantages. Bituthene Liquid Membrane termination. Hydroduct 220. Bituthene System 4000 Surface Conditioner. Bituthene 4000 Waterproofing Memebrane

NEWTON 803 NEWTONITE JOHN NEWTON & COMPANY LIMITED (EST. 1848) DATA SHEET. Damp-proofing Membrane & Plaster Base PRODUCT CODE - M16, M21 & M22

Transcription:

S u b s t r u c t u r e W a t e r p r o o f i n g - Membranes Preprufe 300R www.graceconstruction.com Cl/SfB 19 Ln2 Ref. WM001D 09/04 Pre-applied waterproof membranes that develop an adhesive bond to poured concrete to prevent water migration. For use below slabs and on basement walls. DESCRIPTION Preprufe waterproof membranes are composite sheets comprising of robust HPDE backing, a pressure sensitive adhesive and a trafficable weather resistant coating. Uniquely, the membrane develops a continuous adhesive bond to concrete poured against it. This prevents water migration between the structure and the membrane, substantially reducing the risk of leaks. APPLICATIONS Water and vapour proofing all basement grades to BS8102:1990. Waterproofing civil engineering sub-structures. Methane, CO2 and radon gas protection in excess of the standard membrane requirements in BRE Reports 211 (Radon) and 212 (Methane and CO1 pt). INDEPENDENT ASSESSMENTS BBA Certificate No. 97/3325. Mott MacDonald Special Services Report May 2001. International Certifications. ADVANTAGES Versatile can be used beneath foundation slabs with single or doublesided formwork systems. Seals adhesively to concrete the only technology proven to resist water migration. Lightweight, flexible easy to handle and install without special corner pieces. No butt joints all joints have bonded selvedge or Preprufe Tape overlaps for increased leak protection. Inert unaffected by ground water contaminants, ponded water or wet/dry cycling. Remains sealed to structure even if ground settles. Smooth surface membrane site contamination easily removed. Excellent chemical resistance protects structure from salts and sulphate attack. Total system Full range of Grace hydrophilic and PVC waterstops available for concrete joint protection. SYSTEM COMPONENTS Preprufe 300 R used typically with concrete slab sections greater than 350mm thickness. Superior damage resistance. Preprufe 160R typically used with concrete slab sections up to 350mm thickness and vertically with single and double sided formwork systems. Preprufe Tape incorporating Preprufe coating for continuous concrete adhesion at taped edges and details. Bituthene LM high performance liquid membrane for detailing terminations at pile caps and pipe pentrations. BRITISH BOARD OF AGREMENT CERTIFICATE No. 97/3325 APRIL 2010 SA replaces JULY 2008 SA To the best of our knowledge, the technical data contained herein are true and accurate at the date of issuance and are subject to change without prior notice. User must contact StonCor Africa to verify correctness before specifying or ordering. No guarantee of accuracy is given or implied. We guarantee our products to conform to StonCor Africa quality control. We assume no responsibility for coverage, performance or injuries resulting from use. Liability, if any, is limited to replacement of products. Prices and cost data, if shown, are subject to change without prior notice. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY STONCOR AFRICA, EXPRESS OR IMPLIED, STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

TYPICAL PROPERTIES Supply Preprufe 300R 160R Tape LT* or HC* Thickness (nominal) 1.2mm 0.8mm 0.7mm Roll Size 1.2 x 30.0m 1.2 x 35.0m 100mm x 15.0m Roll Area 36.0m² 42m² Roll Weight 50kgs 42kgs 2kgs Minimum edge/end laps 75mm 75mm 75mm *LT denotes for temperatures between -40 C and 30 C *HC denotes for temperature between +10 C to 50 C Ancillary Products Adcor 500S Bituthene LM APPLICATION Substrates should be sound and smooth and free from standing water. Blinding concrete is recommended below slabs, alternatively use well compacted sand or rolled aggregates. Suitable vertical surfaces include removable formwork, permanent formwork and adjacent sub-structure walls or faced piled walls. MEMBRANE INSTALLATION The membrane should always be installed with the removable plastic film uppermost. Remove the plastic film as laps are formed. Use the lap lines to form 75mm self adhesive selvedge laps between rolls. In cold temperatures, use a hot air gun to dry the membrane and soften the selvedge adhesive. Laps are firmly rolled to maximize adhesion. 5m rolls 5,7lt Preprufe 300R Preprufe 160R Thickness (mm) 1.2 0.8 Adhesion to concrete (N/mm) 2.88 2.88 Shear strength of joints (N/mm) 9.52 9.52 Hydrostatic head resistance (m) > 70 ASTM D 5385 mod > 70 ASTM D 5385 mod Puncture resistance (N) 990 445 Water vapour transmission rate 0 0 (g/m2/24hrs) Methane permeability 9.1 34.8 (mls/m2/24hrs) Radon transmission (m/s) <21 x 10-9 21 x 10-9 End laps and cut edges are lapped 75mm and sealed with Preprufe Tape LT (HC for hot climates). For ease of use, the removable plastic film on Preprufe Tape is tinted blue (red on HC). This film must be removed during installation to ensure bond to concrete. To avoid a build-up of layers, end laps are staggered when applying full length rolls. Being flat faced Preprufe can be easily folded through 90 corners to maintain membrane integrity. VERTICAL MEMBRANE INSTALLATION Mechanically fix the membrane to the formwork using suitable fixings for the substrate. Standard details and comprehensive application instructions are available from Grace Technical Services. Pour concrete within 56 days of membrane installation (42 days in hot climates). REMOVAL OF FORMWORK Preprufe can be installed in removable formwork systems for slab perimeters and walls. Formwork can be removed when the concrete has a minimum compressive strength of 10N/mm². WALL WATERPROOFING OPTIONS Grace also offers alternatives to preapplying Preprufe to vertical formwork. For conventional application to walls after formwork removal, use either: Bituthene 8000 self adhesive sheet water waterproofing membrane. Procor 75 spray applied liquid waterproofing membrane. Selection of the most cost-effective solution will depend on the construction programme, type of formwork system, wall height, etc. See separate data sheets for further information. ANCILLARY PRODUCTS Adcor 500S Hydrophilic waterstop for construction joints and pipe entries. AT System Co-extruded PVC waterstops for movement joints. Bituthene Protection Board protection against damage from backfill. NBS SPECIFICATION CLAUSE Refer to clause J40 297 HEALTH & SAFETY There is no requirement for a Material Safety Data Sheet for Preprufe. For health and safety questions on this product, please contact Grace. For Bituthene LM, read the product label and Material Safety Data Sheet (MSDS) before use. Users must comply with all risk and safety phrases. MSDS s can be obtained from Grace Construction Products or from our website at www.graceconstruction.com

Preprufe Application Method Statement PRODUCT CONCEPT Pre-applied waterproof membranes that develop an adhesive bond to poured concrete. Thus preventing lateral water migration at the interface of the membrane and the structure that is being protected. Preprufe is intended for all applications where the membrane is applied before concreting. PRODUCT DESCRIPTION Composite sheets comprising a robust HDPE backing, a pressure sensitive adhesive and a trafficable weather resistant coating. Product Range and Recommended Applications Product Preprufe 300R Preprufe 160R Preprufe Tape LT Preprufe Tape HC Bituthene LM Hydroduct 200 Bituthene Protection Board Adcor 500S AT System HEALTH AND SAFETY There is no legal requirement for a Material Safety Data Sheet for Preprufe 300R, Preprufe 160R and Preprufe Tape. For health and safety questions on these products, please contact Grace Construction Products Limited. For Bituthene LM, read the product label and Material Safety Data Sheet (MSDS) before use. Users must comply with all risk and safety phrases. MSDS s can be obtained from Grace Construction Products or from our website at www.graceconstruction.com. Recommended Applications - Horizontally, under sub-structure slabs > 350mm thick - Horizontal and vertical applications where risk of membrane damage from reinforcement placement, backfilling or other site operations is considered high - Horizontally, under sub-structure slabs < 350mm thick - Vertically, against sub-structure walls with single or double sided formwork systems - Applications at -5 C to +30 C - Taping roll end laps, cut edge laps and detailing - Applications at +10 C to +50 C - Taping roll end laps, cut edge laps and detailing - Liquid membrane for detailing terminations, pile caps and pipe pentrations - Drainage geo-composite, for use on irregular substrates to provide a suitable surface for Preprufe application - Optional protection of Preprufe 160 applied in doublesided formwork, prior to backfilling - Hydro expansive waterstop for use in concrete construction joints and at pipe entries - Hydro-expansive / PVC co-extruded waterstop for movement and expansion joints MATERIAL STORAGE Sequence deliveries to avoid delays, but minimize on-site storage. Select a safe, covered secure location for material storage. Store materials for each day s use in a location that won t require movement a second time. Do not doublestack pallets of waterproofing on the job site. Store protection boards flat and off the ground. Provide cover on top and all sides. SUBSTRATE PREPARATION Suitable substrates include: - concrete blinding - well compacted sand or rolled crushed stone - rigid insulation - clay heave boards - permanent formwork - removable formwork - 19mm plywood - Hydroduct drainage sheets - Adjacent substructures Substrates should be uniform with no gaps or voids greater than 12mm. Where these exist, fill with a material of sufficient strength to support the membrane. All substrates must be free of loose aggregate and sharp protrusions. Where possible, avoid sloping or rounded concrete blinding. In crushed stone applications, it is important to create a sound and solid substrate around through slab penetrations to eliminate movement during the concrete pour. Excessive movement may jeopardize the waterproofing integrity around the penetration. Grout around the penetration prior to installing the membrane for stabilization. The surface does not need to be dry, but standing water must be removed. Substrates must have sufficient rigidity not to move during the concrete pour. Boarded substrates must be close butted to provide support and not more than 12mm out of alignment.

INSTALLATION GENERAL - Tools / material is required - Heavy-duty lap roller - Stanley / utility knifes - Tape measure - Cotton cleaning cloths - Plywood or similar cutting board - Thin metal straight edge - Chalk line - Broom - 2 Metre long pipe or heavy broom handle - Hot air heat gun - Grace MR2 paddle for mixing Bituthene LM - Round nose trowel or spatula - Required protection and/or drainage boards and other ancillary products Preprufe membranes are supplied in rolls 1,2m wide with a self adhesive selvedge on one edge to enable fully bonded laps between adjacent rolls. All other laps must be taped with Preprufe Tape. Minimum application temperature -5 C. During cold and damp conditions, the selvedge and tape adhesive can be gently warmed using a hot air gun or similar to remove moisture and improve adhesion. INSTALLATION HIRIZONTAL Place the membrane with the removable plastic release liner uppermost. End laps should be staggered to avoid a build-up of layers. Leave plastic release liner in position until overlap procedure is completed. Accurately position subsequent sheets to overlap the previous sheet 75mm along the selvedge. Ensure the underside of the succeeding sheet is clean, dry and free from contamination before attempting to overlap. Peel back the plastic release liner from between the overlaps as the two layers are bonded together. Ensure a continuous bond is achieved with creases and roll firmly. On completion of the installation, completely remove the plastic release liner from all membrane and tape. END LAPS AND CUT EDGES Overlap all roll ends and cut edges by a minimum 75mm and ensure the area is clean and free from contamination, wiping with a damp cloth if necessary. Allow to dry and apply Preprufe Tape centred over the lap and roll firmly. Refer also to Preprufe Standard Details. INTERNAL & EXTERNAL CORNERS Internal and external corners should be formed as shown in the diagrams below. Ensure that all laps are 100mm minimum, taped with Preprufe Tape and well rolled. Crease and fold the membrane to ensure a close fit to the substrate profile. PENETRATIONS To seal around penetrations such as service pipes, pile heads, lightning conductors, etc., mark and cut membrane tight to the penetration. If the membrane is not aligned within 12mm of the penetration, apply Preprufe Tape lapped onto the membrane and butted tight to the penetration. For pipe penetrations, wrap the pipe with Preprufe Tape. Mix and apply Bituthene LM around the penetrations using a fillet to provide a watertight seal between the Preprufe membrane and Tape. Refer also to Preprufe Standard Details.

MEMBRANE REPAIR Inspect the membrane for damage before installation of reinforcement steel, shuttering and final placement of concrete. Clean by jet washing if required. Wipe the area with a damp cloth to ensure the area is clean and free from dust, and allow to dry. For minor repairs, apply Preprufe Tape centrally over the damaged area and roll firmly. For larger repairs, use a patch of Preprufe and tape all edges with Preprufe Tape. Remove plastic release liner from Tape. Where exposed selvedge has lost adhesion or laps have not been sealed, ensure the area is clean and dry and overband with Preprufe Tape and roll firmly. INSTALLATION VERTICAL Apply the membrane with the thick white plastic face against the substrate. Mechanically fasten the membrane vertically using flat headed fixing appropriate to the substrate. The membrane may be installed in any convenient length. Secure the top of the membrane using a batten or fixing 50mm below the top edge. Use fixings at typically 600mm centres to secure the membrane flat against the substrate. Fixings can be made through the selvedge, this allows firmly rolled overlaps, which are covered by the subsequent strip of Preprufe. Any exposed fixings should be patched with Preprufe Tape. Ensure the underside of the succeeding sheet is clean, dry and free from contamination before attempting to overlap. Peel back the plastic release liner from between the overlaps as the two layers are bonded together. Ensure a continuous bond is achieved without creases and roll firmly. On completion of the installation, completely remove the plastic release liner from all membrane and tape. INSTALLATION DOUBLE SIDED FORMWORK Wooden formwork: 1. Apply the membrane with the thick white plastic face against the formwork. 2. Cut lengths of membrane to height of shutter less 50mm. 3. Align the first piece of membrane against the shutter edge and 50mm below the top of the shutter. 4. Nail the membrane in place at the top of the shutter using 40mm galvanised clout nails at 300mm centres. The nail heads should be left protruding a minimum 20mm. (This will enable encapsulation of the nail head when the concrete is poured). 5. At the middle and bottom of the shutter, cut and apply 150mm x 150mm square patches of Bitustik 4000 double sided bituminous tape to both edges of the membrane. 6. The Bitustik 4000 patched will partially adhere the membrane to the formwork and keep it flat during the concrete pour. 7. All edge laps should be formed using the self-adhesive selvedge on the membrane. 8. Any cut edge laps and end laps should be sealed with Preprufe Tape. 9. On completion of the installation, completely remove the plastic release liner from all membrane and tape. 10. Place shutter, pour and vibrate concrete. 11. Remove formwork when concrete has a minimum strength of 10N/mm². 12. After removal of formwork: - Use a hammer to bend all protruding nail points flush to membrane surface. - Fill tie bar holes with BETEC NSM mortar, allow 48 hours to dry, then prime with B2 Primer and cover with cut patches of Bituthene 4000 self adhesive membrane, 150mm x 150mm. - Lap Preprufe membrane at bottom of wall to slab edge membrane using cut strips of Bituthene 4000 self adhesive membrane, 300mm wide. - Form agreed termination detail at ground level using Bituthene LM. Metal work: 1. Install Preprufe as for wooden formwork except: 2. At top of metal formwork fix Preprufe membrane to flange of formwork system using bolts or tie wire. 3. On removal of formwork, cut the excess unbonded membrane at the top of the wall flush, using a straight edge to avoid damaging the bonded membrane.

REMOVAL OF FORMWORK Preprufe membranes can be applied to removable single and double sided formwork, slab perimeter formwork, pile caps, etc. Once concrete is poured, the formwork must remain in place until the concrete has gained sufficient compressive strength to develop the surface bond with Preprufe. A minimum concrete compressive strength of 10N/mm² is recommended prior to stripping formwork supporting Preprufe membranes. Premature stripping may result in loss of adhesion between the membrane and concrete. As a guide, to reach the minimum compressive strength stated above, a structural concrete mix with an ultimate strength of 40N/mm² will typically require a cure time of approximately 6 days at an average ambient temperature of 4 C, or 2 days at 21 C. PREPRUFE PREPARATION WHEN Bituthene is used on walls: Inspect the Preprufe around the perimeter edge of the concrete slab. Identify any loose overlaps in Preprufe that have not been fully bonded with the selvedge adhesive lap before the concrete was poured. To ensure continuity of the fully bonded system, carefully cut and remove a 75mm triangular piece of the top loose sheet of Preprufe only, as shown shaded in the standard detail, Slab Perimeter Detail no selvedge lap. LIMITATIONS OF USE - Do not use Preprufe between concrete infilled hollow block walls. - It is recommended that concrete be poured within 56 days (42 days in hot climates) of application the membrane.