Methods for Evaluating Advanced Electronics Cooling Systems

Similar documents
How to Optimize Oil and Gas Refinery Operation Profits with Engineering Simulation

CHAPTER-1 INTRODUCTION

AN OVERVIEW OF ADVANCED ELECTRONICS COOLING Emphasis on Liquid Metals Solutions

Performance Improvement of a Micro Channel Heat Sink

FSI ANALYSIS OF TRAILING EDGE REGION COOLING IN HP STAGE TURBINE BLADE

Electronics Cooling Products

Thermal Management Roadmap Avram Bar-Cohen Department of Mechanical Engineering University of Maryland

Closed Loop Liquid Cooling for High Power Electronics

Performance Improvement on Water-cooled Cold-Plate

Smart Integration of Thermal Management Systems for Electronics Cooling

Closed Loop Liquid Cooling for High Power Electronics

ATS WHITE PAPER. Experimental Study on a Hybrid Liquid/Air Cooling System

High Power in Small Spaces: Myths

Abstract. 1. Introduction

Liquid cooling facilitates tomorrow s embedded systems

Thermal Management and Packaging Challenges of High Power Devices

USING INTEGRATED PLANAR THERMOSYPHON PCBs TO ENHANCE COOLING OF HIGH BRIGHTNESS LEDs

International Journal of Advance Engineering and Research Development

Cooligy. The Heat Problem. Why Keep CPUs Cool? Active Micro-Channel Cooling. Peak Power Density (Watts/cm 2 ) Total Power (Watts)

Beating the Heat Dealing with the Thermal Challenge: Past, Present and Future

The Future of Lighting Fixture Design LED Thermal Management

DESIGN OF LIQUID COOLING FOR HIGH HEAT DISSIPATION ELECTRONIC BOARDS USING CFD

Spray cooling of IGBT electronic power modules

Thermal Performance of Thermoelectric Cooler (TEC) Integrated Heat Sink and Optimizing Structure for Low Acoustic Noise / Power Consumption

Multiphysics Simulation Optimizes Design of EGR Coolers

CFD-BASED INVESTIGATION OF HEAT TRANSFER CHARACTERISTICS OF FLUE GAS-WATER HEAT EXCHANGER PANELS PRODUCED WITH A NOVEL MANUFACTURING PROCESS

Heat Optimisation of Processor Cooling by Varying casing Material

Investigating Two Configurations of a Heat Exchanger in an Indirect Heating Integrated Collector Storage Solar Water Heating System

Numerical Simulation Of A New LNG Vaporizer Using Flue Gas To Impact Umbrella Rotor

Understanding Spray Technology to Optimize Sulfur Burning

Engineering Knowledge Management

THERMAL ANALYSIS OF CPU WITH VARIABLE BASEPLATE HEAT- SINK USING CFD

Trends and Challenges in the Thermal Management Field

ADVANCED HYBRID MODELLING OF SEPARATORS FOR SAFE DESIGN IN OIL/GAS PRODUCTION PLANTS

SynJet Augmented Cooling for Cloud Computing. Raghav Mahalingam

The Role of Engineering Simulation in Clean Coal Technologies

2009 PFC Meeting. Two-phase CFD Analysis of ITER FW Hypervapotrons

OINTRODUCTION. Technology Overview for Oil Services Companies: Using Flow Modeling to Lower Costs, Increase Reliability, and Reduce Risks

ANALYSIS FOR NATURAL CIRCULATION LOOP

LED Active Cooling - The Need for Advanced Thermal Management Solais Lighting White Paper

LED Active Cooling - The Need for Advanced Thermal Management Solais White Paper

Investigating two configurations of a heat exchanger in an Indirect Heating Integrated Collector Storage Solar Water Heating System (IHICSSWHS)

ACTIVE COOLING METHOD FOR CHIP-ON-BOARD LEDS

PERFORMANCE ANALYSIS OF NATURAL DRAFT WET COOLING TOWER AT OPTIMIZED INJECTION HEIGHT

NUMERICAL STUDY ON FILM COOLING AND CONVECTIVE HEAT TRANSFER CHARACTERISTICS IN THE CUTBACK REGION OF TURBINE BLADE TRAILING EDGE

Developing next generation solutions for heating, cooling & energy harvesting

Advanced Analytical Chemistry Lecture 13. Chem 4631

CMR Journal of Engineering and Technology Vol.2 Issue.1 June, 2017

THERMAL CONTROL OF ELECTRONICS: PERSPECTIVES AND PROSPECTS

IMPROVED PRODUCTIVITY WITH USE OF FLOW NETWORK MODELING (FNM) IN ELECTRONIC PACKAGING

ANSI/IEEE Standard C57.12"Standard Guide for Loading Mineral Oil Insulated Transformers"

Liquid Metal Heat Sink for High-Power Laser Diodes a,b

ANSYS, Inc. March 31, Phase Change Models in FLUENT

A New Continuous Wave 2500W Semiconductor Laser Vertical Stack

COOLING EFFECT ENHANCEMENT IN MAGNETRON SPUTTERING SYSTEM

Experimental investigation of a novel heat pipe cold plate for electronics cooling

Local Single- and Two-Phase Heat Transfer from an Impinging Cross-Shaped Jet

CFD ANALYSIS OF MINI CHANNEL HEAT EXCHANGER USING WATER AS A WORKING FLUID

HEAT TRANSFER IN POROUS SURFACES OF EVAPORATORS OF HEAT MACHINES AND DEVICES

Numerical Analysis of Heat Pipe Fin Stack by Delta Wing Vortex Generator

Thermal Challenges During Microprocessor Testing

NUMERICAL ANALYSIS OF HEAT PIPE HEAT EXCHANGER BY DELTA WING VORTEX GENERATOR

Download this article in.pdf format This file type includes high resolution graphics and schematics when applicable.

Ten glorious years of service to industry & customers ENGINEERING SERVICE OVER VIEW & IMPORTANT PROJECT- CASE STUDY

COOLING TOWER DESIGN FOR CENTRAL GENERATORS OF CUET, BANGLADESH. Mohammad Sharif Khan, Golam Mainuddin, Abu Sadat Mohammad Sayem, Nadeem Nafis

Splat formation in plasma-spray coating process*

HEAT TRANSFER PERFORMANCE OF AN OIL JET IMPINGING ON A DOWNWARD-FACING STAINLESS STEEL PLATE

Quenching steels with gas jet arrays

Power Electronics Packaging Revolution Module without bond wires, solder and thermal paste

ANALYZE THE THERMAL PROPERTIES BY VARYING

Opportunities in the Mechanical Parts of the System. Dr. Thomas Kenny DARPA/MTO

Endless Possibilities Use of Heat Pipe for Global Warming Reduction

CFD MODELING AND PARAMETRIC STUDY OF VAPOR CHAMBERS AS HEAT SPREADERS FOR HIGH-POWER ELECTRONIC DEVICES DHANRAJ ARUN PATIL

CFD SIMULATION AND EXPERIMENTAL VALIDATION OF FLUID FLOW IN LIQUID DISTRIBUTORS

heat exchanger modelling for generator ventilation systems

Applicability of Minichannel Cooling Fins to the Next Generation Power Devices as a Single-Phase-Flow Heat Transfer Device

NUMERICAL SIMULATION OF INTERNAL COOLING EFFECT OF GAS TURBINE BLADES USING V SHAPED RIBS

Novel Approaches to Thermal Management for Power LED Packaging

Ultra Thin Flat Heat Pipes

EFFECT OF COMBINED HOLE CONFIGURATION ON FILM COOLING WITH AND WITHOUT MIST INJECTION

Optimization of a Dual-Fuel Low-NOx Combustion System for a Tangentially-Fired Utility Boiler Operating at a High Elevation.

CFD Simulation of Compact Type Mini Channel Heat Exchanger by Using of Water P.J.Pan 1 N.S.Patel 2

Evaluating Performance of Steam Turbine using CFD

OIL POOL FIRE IN A LARGE TURBINE HALL CFD simulation

Embedded Cooling Solutions for 3D Packaging

Reliability Study of Micro-Pin Fin Array for On-Chip Cooling

FABSTRACT. Technical Overview of Fuel Cell Systems: How Computer Simulation is Used to Reduce Design Time

HX Performance Testing

Thermal Symposium August Minteq International, Inc. Pyrogenics Group A Thermal Management Solution for State-of-the-Art Electronics

Review of Two-phase Electronics Cooling for Army Vehicle Applications

Investigation on the Impact on Thermal Performances of New Pin and Fin Geometries Applied to Liquid Cooling of Power Electronics

CFD and Wind Tunnel Study of the Performance of a Multi- Directional Wind Tower with Heat Transfer Devices

Study of water falling film over horizontal drop shaped and inverted drop shaped tubes

Numerical method for modelling spray quenching of cylindrical forgings

Graphite Foam for Cooling of Automotive Power Electronics

IMTE AG, Switzerland Power Consulting Engineers DRY SYSTEMS FOR POWER PLANT COOLING. 1. Need for Water Conservation in Power Plant Cooling

Using Computational Modeling in the Development and Design of Alternative Powertrain Vehicles

ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS

OpenVPX Chassis Thermal Management: Dangerous Myths and Analytical Tools

HEAT TRANSFER STUDY OF 3-D PRINTED AIR-COOLED HEAT SINKS

Transcription:

A W H I T E WP AH PIE TR EF R OP MA AP N ES YR S, I N C. Methods for Evaluating Advanced Electronics Cooling Systems Hossam Metwally, PhD Senior Consulting Engineer, Electronics Industry Fluent Inc. ABSTRACT As predicted by Moore s law, microprocessor power dissipation is on a steady rise. In addition, the current technology is also enabling considerable feature size reduction resulting in an even sharper increase of local heat fluxes on dies. If the current pace continues, estimates indicate that power densities of 100 W/cm2 will eventually be reached. In fact, hardware manufacturers have determined that dual core processor technology is the path to profitability. A processor with two 2.5- gigahertz processors can outperform a chip with a single 3.5-gigahertz processor in certain situations. The higher the temperature of a typical semiconductor, the lower its performance reliability and life expectancy. The The graphical user interface showing the wizard panel and pressure inverse proportionality is not linear, but exponential, meaning that a mere distribution on a cyclone. reduction in chip temperature will have a considerable effect on both performance and durability. Since the final sink temperature, ambient air temperature, is constant, removing the ever-increasing heat fluxes while maintaining the same junction-to-ambient temperature will only be possible through the introduction of advanced cooling systems. Examples include active heat sinks, air jet impingement, micro channel cooling, heat pipes, immersion cooling, and spray cooling. Those systems, though far superior in heat removal rates, pose a more challenging to the designer and require novel tools for their design and analysis. CURRENT CHALLENGES Forced-air cooling using the traditional fan sink system will continue to be a work horse for electronics cooling because of its cost, reliability, and its familiarity to the design engineer. However, given the current and futuristic dissipation trends in chip design, it is evident that hybrid cooling systems, containing both traditional forced air cooling and an advanced cooling system that enables the local removal of high heat fluxes, will be the practical in thermal management. An overview of leading-edge advanced cooling systems follows. The graphical user interface showing the wizard panel and pressure distribution on a cyclone. WP-103 1

ACTIVE HEAT SINKS Active heat sinks are the to minimize the ducting and leakage s present in forced convection air cooling. By making the heat sink an integral part with the fan, leakage is non-existent. However, care must be taken in the design of active heat sinks since the performance of the fan(s) is now affected by the presence of the heat sink attached to it and how the active heat sink is located within the global system. It may not be appropriate to use a lumped analysis model based on the known fan curve to represent the fan within the active heat sink. Actual non-uniform flow into the fan and the nature of the flow dictated by the heat sink at the fan exit pose a different operating scenario than the fan curves obtained during typical fan tests. Additionally, the fins in the active heat sink may be designed based on a certain air speed that may differ from that provided by the fan after being installed within the active heat sink. Thus, the design of the active heat sink should involve the conjugate design of both the fan and the heat sink. ACTIVE HEAT SINK IN PRACTICE result According to fan manufacturer data, it was believed that it would deliver a sufficient amount of air. After being integrated within the heat sink and installed in the system, the amount of air delivered by the fan was found to be less than required by the design. Due to the location of the active heat sink within the system, the flow was found to be non-uniform at the fan inlet. Also, the presence of the fins at the exit of the fan was changing the flow nature exiting the fan and thus the fan performance. Flow visualization has revealed the flow non-uniformity entering the active heat sink. Detailed flow analysis at the fan exit showed recirculation zones between the fan and the fins. This has lead to redesigning the fan blades with the intent to adjust the fan outflow to align with the fins. The new fan design inside the active heat sink has increased the flow rate by 15%. Analyzing the performance of the active heat sink within the system has proven important. Another aspect of increasing importance is the amount of noise generated by the fan. The design should not only provide sufficient cooling, but also should have noise levels that are acceptable, and comfortable, to the end user. Additionally, similar to the flow performance of the fan, the acoustical performance of a stand-alone fan may be different for the same fan when installed in a system, e.g. within an active heat sink which is in turn installed in a bigger system. The resulting airflow in and out of the fan under installed conditions would affect the acoustical noise generated from the fan. 2008 ANSYS, Inc. All Rights Reserved. WP-103 2

FAN NOISE PREDICTION IN PRACTICE Two fans have proven to deliver a similar amount of air that is found acceptable. The designer would like to select the most acoustically friendly one. Air flow analysis of each design under consideration reveals the acoustical behavior of the two fans under installed conditions, including acoustical pressure, most dominant frequencies, and acoustical power densities. System level analysis including detailed fan modeling within the active heat sink results By comparing the acoustical behavior of the two fans, the favorable fan acoustically (least power spectral density and Sound Exposure Level SEL) is selected. Junction-to-ambient thermal resistance eventually reaches an asymptotic value with the continual increase of air speed for forced air-cooling systems AIR JET IMPINGEMENT The concept of using a concentrated jet for localized high heat flux cooling is similar to that used for metal quenching. Jet impingement offers not only the ability to remove high heat fluxes but also the ability to target hot spots or uneven heating. In addition, the jet placement is not a crucial factor with respect to the cooled part. A concentrated jet does not spread out in a conical fashion as a typical spray would and that makes its design simpler. The drawback is that a high pressure head is needed that would be converted to high kinetic energy of the jet. Also, there may be some noise concerns because of the high speeds. These cautions can be analyzed up front at the time of design to weigh out the benefits and risks. MICRO CHANNELS Micro channels are based on a very simple heat transfer concept: the heat transfer coefficient for laminar flow (very slow flow through a narrow channel) is inversely proportional to the hydraulic diameter. This means that the smaller your channel is, the higher your ability to draw heat from the source. Micro channels typically have sizes in the 5 to 100 μm range leading to a heat transfer coefficient of that may reach 80,000 W/m2K. They are typically etched on the die surface in the shape of rectangular grooves. There are commonly two main s when designing a system of micro channels: pressure drop and flow uniformity across the channels. The smaller hydraulic diameter results in a higher heat transfer coefficient on the one hand but higher pressure-drop on the other hand. This would require higher pumping power. One for that is called stacking instead of having a single layer of micro channels on top of the heat source, you WP-103 3

MICRO CHANNELS IN PRACTICE When testing the design, it was found that the die temperature at certain points was higher than allowed. Also, the pressure drop across the micro channels was too high. Flow analysis through the micro channel stack has revealed that the manifold feeding the micro channels does not result in uniform flow through all the channels. Non-uniform flow results in nonuniform cooling and temperature distribution. results By redesigning the manifold, uniform flow through the channels was ensured. Uniform flow also leads to lower pressure drop across the stack. Maximum temperature was reduced by 10%. may have two, three, or more stacks. Studies have shown that most often two or three stacks are a good compromise between heat transfer behavior and pressure drop. Flow non-uniformity across the micro channels would result in nonuniform cooling, which may have implications on both the performance and reliability. HEAT PIPES Heat pipes are now the darlings of portable electronics cooling. They offer a high degree of flexibility in design and have proven to be extremely reliable since they are passive with no moving parts. Their heat transfer characteristics are superb, offering effective conductivities up to several thousands of that of copper, enabling the transfer of heat with minimal temperature gradient. Keep in mind when designing or selecting a heat pipe for a certain system, the known limits must be taken into consideration. These limits include the capillary limit, boiling limit, sonic limit, entrainment limit, and flooding limit. Depending on the design of the heat pipe, its orientation within the system (e.g. gravity-aided, acting against gravity or horizontal), and the heat flux applied to it, it may hit one of its limits and fail to perform its cooling duties. To ensure the proper function of the heat pipe within the system, the dynamic operation of the system with the heat pipe has to be analyzed under different conditions to ensure continuous performance. SPRAY COOLING Spray cooling has the promise of extracting heat fluxes in excess of 100 W/cm 2. Typically a liquid is sprayed directly on the die, which makes the use of a dielectric fluid essential, where it gains heat, converts to vapor and is cooled far away WP-103

from the heat source, condenses and then re-pumped to be sprayed again. Sprays may be generated through different mechanisms, such as nozzles (pressure sprays or atomization sprays) or even through the use of inkjet-inspired technology 1. The latter has the advantage of being able to target non-uniform heat sources and avoid pooling of liquid on cooler parts of the heat source. Design variables include nozzle design, spacing between nozzle exit and target, spray flow, liquid properties, and heat flux all of which must be analyzed closely to avoid potential s. PROPERTY FC-72 H 2 O Boiling Point @ 1atm (ºC) 56 100 Density (kg/m 3 ) 1680 997 Specific Heat (W-s/kg-K) 1088 179 Thermal Conductivity (w/m-k) 0.055 0.613 Dynamic Viscosity x10 (kg/m-s).50 8.55 Heat of Vaporization x10 - L (W-s/kg) 8.79 23.8 Surface Tension x10 3 (N/m) 8.50 58.9 Thermal Coefficient of Expansion x10 3 (K -1 ) 1.60 0.20 Dielectric Constant (= 1 for vacuum) 1.72 78.0 Why use a dielectric liquid instead of water? Same weight of water will extract more than three times the heat for the same temperature rise (higher specific heat) Water is eleven times more conductive Same weight of water upon evaporating will extract 27 times more heat (higher heat of vaporization) However, FC-72 has a dielectric constant that is 2% that of water, i.e. much less unwanted current will flow! SPRAY COOLING IN PRACTICE The heat source had non-uniform heat generation. The tested spray array was not able to extract the non-uniform heat and resulted in local hot spots. Spray analysis results showed that local liquid pools are formed at areas with lower heat fluxes. Amount of spray reaching high heat fluxes areas was inadequate. By adjusting the nozzle locations with respect to the target and changing the nozzle array, better targeting of hotter surfaces was achieved and pooling was avoided. result Results showed that the maximum liquid film thickness on the die is reduced by 100% and therefore pooling is avoided. Temperature uniformity on the die surface was also improved by 20%. Spray cooling of a hot surface with liquid droplets; temperature contours are shown; liquid droplets are colored by diameter (red = initial large droplets, blue = smaller splashed droplets) WP-103 5

IMMERSION COOLING / DIRECT CONTACT COOLING The terms immersion or direct are used to describe this approach because the working liquid comes into direct contact with the chip. The liquid may be moving passively due to natural convection or be driven by a pump. The liquid may also undergo partial phase change in which case much higher heat fluxes may be attained. Typically, excessive boiling should be avoided in order to reduce the creation of large bubbles that would lead to local hot spots. Instead, the preferred condition is that of sub-cooled boiling where the bubbles are small enough to re-condense into the main flow. IMMERSION COOLING IN PRACTICE result Local hot spots were observed on the die. Flow analysis showed that the design of the passages and the die geometries lead to the existence of recirculation zones near some dies. Liquid trapped in these zones eventually would heat up excessively. By redesigning the flow passages to accommodate for the existing die geometries, flow uniformity was improved and recirculation zones were minimized. Maximum temperature was reduced by 8%. CONCLUSIONS Several advanced cooling systems have been discussed. The main objective behind all of these approaches is to be able to extract high heat fluxes from the chip while keeping the junction temperature acceptable. Having an advanced tool like computational fluid dynamics (CFD) software which enables the exact modeling of the physics involved (flow, heat transfer, phase change, condensation, boiling, spray) is essential for rapid and accurate design and comparison of these novel cooling systems. Also, the performance of individual components of the cooling, like fans and heat pipes, may be affected by the performance of the overall system surrounding them. It is important to test the performance of individual components under real system operating conditions to ensure their proper operation. CFD technology has proven to be effective in visualizing such conditions. 1 Bash, C.E., Patel, C.D., Sharma, R.K., Inkjet Assisted Spray Cooling of Electronics, International Electronic Packaging Technology Conference and Exhibition, July 6-11, 2003, Maui, Hawaii, USA. About ANSYS, Inc. ANSYS, Inc., founded in 1970, develops and globally markets engineering simulation software and technologies widely used by engineers and designers across a broad spectrum of industries. ANSYS focuses on the development of open and flexible s that enable users to analyze designs directly on the desktop, providing a comon platform for fast, efficient and cost-conscious product development, from design concept to final-stage testing and validation. ANSYS and its global network of channel partners provide sales, support and training for customers. Headquartered in Canonsburg, Pennsylvania, U.S.A., with more than 0 strategic sales locations throughout the world, ANSYS and its subsidiaries employ approximately 1,00 people and distribute ANSYS products through a network of channel partners in over 0 countries. Visit http:// for more information. ANSYS, Inc. Southpointe 275 Technology Drive Canonsburg, PA 15317 U.S.A. 72.76.330 ansysinfo@ansys.com Toll Free U.S.A./Canada: 1.866.267.972 Toll Free Mexico: 001.866.267.972 Europe:.870.010.56 eu.sales@ansys.com WP-103 6