JAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES

Similar documents
Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Nominal Core OD Materials. Conductor (stranding) Diameter Nom. DCR

Data sheet chainflex CFSPECIAL.182

Data sheet chainflex CF887

Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA

PV Solar Wiring Solutions


Glossary Of Terms M-1

3M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 3560 Series

Caledonian Cables Ltd

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

Detailed Specifications & Technical Data

Available in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990

Tele-Fonika Cable Americas

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant

SafeX110 Single Core Flexible Tinned Copper Cable

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Building Wire CARRYING YOUR ELECTRICITY

Wire and Cable SPEC 44 Wire and Cable

3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series

SECTION INSULATED WIRE AND CABLE

Flexible Conduit Systems

FieldLink for PROFIBUS Applications

3M Round, Jacketed, Flat Cable.050" 28 AWG Stranded, Mass-Term, PVC/PVC 3759 Series

Single core conductor BETAtherm 145

PRODUCT SELECTION LOCATOR

Highly flexible, screened control cable with PVC core insulation and abrasion and oil resistant PUR sheath

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LSC5FS (INCLUDING VARIATIONS LSC5FSW, LSC5OS, AND LSC5OSW)

T&B Catalog Number: TY15X2SPG6 UPC Number: Description: Nominal Width (inches) 1.5 Nominal Height (inches) 2

America s Wire Company

3M Pleated Foil Shielded Cable.025" 30 AWG Solid, TPE Primary, PVC Jacket, Low Skew Series

Cables ELE E L CT E C R T R IC I C A A L L

Outdoor Carrier Class Shielded Ethernet Cable. Datasheet. Models: Level 1/Level 2, TOUGHCable Connectors. Increase Performance. Extreme Weather-Proof

CABLEMASTER CABLE GUIDE

Compact Module. Enhanced Category 5 FTP Cabling System

according to UL AWM 758, Style and based on EN resp. VDE

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Industrial Cable for Factory Automation

Energy Chain System Training

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

VERSAFIT V2 AND V4 TUBING Polyolefin, Flexible, Heat-Shrinkable, Flame-Retardant

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

Flame-retardant, cross-linked polyolefin. Shrink temperature of 120 C. Cat. No.*

Anaconda SEALTITE. When you say SEALTITE, there is only one: ANACONDA. Index FLEXIBLE CONDUIT TYPES 4-5. ANAMET Electrical, Inc.

0.025" [0.64mm] Centerline PVC IDC Ribbon Cable

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

electric snow melting mats

3M Ground Plane Cable.050" 28 AWG Stranded, One Drain, PVC 3476 Series

Shrink-Kon Thin Wall Heat Shrinkable Tubing

ABOUT US. 830 South West Street / Sikeston, MO / F: alanwire.com

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

Application (easy to strip) ES cable for permanent installation. and mechanical stress (easy to strip) 1x2x22AWG 1

Welding Accessories

Heat-Shrinkable Tubing

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

26/35kV Copper XLPE Insulation Electric Cable

Technical Data. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE

SECTION GROUNDING AND BONDING

Anaconda SEALTITE. When you say SEALTITE, there is only one: ANACONDA. Index FLEXIBLE CONDUIT TYPES 4-5

NORMAS DE REFERENCIA AEIC CS 1: ASTM B

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

Overall Length

loop 0.60 mh/km 0.65 mh/km RCCY031/032 /KS1 RCCY031/032 /NS mh/km 0.70 mh/km RCCY033/034 /KS1 RCCY033/034 /NS1

STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for

Construction guideline

FP30112WHITE100 Heat Shrink TW Tubing 100' Spool

CATALOG. WIRE and CABLE. borderstates.com

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

BUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11

Shinn Thon UK Ltd 1 st Floor, 223 Dalton Road, Barrow in Furness, Cumbria. LA14 1PQ Tel: Fax:

POSEIDON SCIENTIFIC INSTRUMENTS PTY LTD 17 QUEEN VICTORIA ST, FREMANTLE WA PHONE (08) FAX (08) CAB-0XXX (SALEM CODE)

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

Outdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection

UNIFIED FACILITIES GUIDE SPECIFICATIONS

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS3SWU (INCLUDING VARIATION LS3SWUS)

3 MODIFICATIONS TO EXISTING STANDARDS

YF /8" YF /2" YF /4"

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

Outdoor Carrier Class Shielded Ethernet Cable. Models: PRO, CARRIER, Connectors. Increase Performance. Extreme Weatherproof. ESD Damage Protection

Manhattan Thermocouple Cable

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018

Liquatite. Flexible Conduit JIC. Steel Core. Type LT

PURENET-U (Part No.: U RXX2, U PXX2)

OFFSHORE CABLES NEK 606 : with FIREBAR the TOTAL SAFETY fire and water resistant cable

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

MATERIAL SPECIFICATION FOR EXTRA LOW-VOLTAGE CABLE

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

Coaxial Cables for Broadband Communication Networks European Edition

Procurement Engineering Standard Purchase Clause

DETAIL SPECIFICATION CABLE, ELECTRICAL, FOR SHIPBOARD USE, GENERAL SPECIFICATION FOR

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

Electrical Conductors Line

RG-59, RG-59+2DC, UTP CAT6, SFTP CAT6

Transcription:

WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES

Elevator Hoistway & Traveling Cables... Designed for high performance and durability, like all wire and cable products manufactured by the James Monroe Wire and Cable Corporation, our Elevator Cables have become a well known and trusted brand in the North American Elevator Market. Our Elevator Cable products are available throughout the United States and Canada through a network of distributors that are focused on customer service, delivery and competitive prices. As a specialty and custom cable manufacturer, the James Monroe Wire and Cable Corporation also manufactures custom Elevator Cable products to meet your specifications at reasonable prices and lead times.

WIRE & CABLE CORPORATION Traveling Cable ETT Traveling Cable 300V Power / Signal, s & Coax For use in Elevator Hoistways in accordance with Article 620 of the NFPA 70 National Electrical Code Features: Flexible Copper Conductors VW-1 / FT1 Rated Steel Core per Mil-W-83420 Inner / Outer Synthetic Braid Optional s & Coaxial Cable Components Flexible Bunch Stranded Bare Copper Conductors 60 C Flame Retardant Polyvinyl Chloride Insulation Flame Retardant PVC Insulated Steel Core per Mil-W-83420 Inner / Outer Synthetic Braids Optional 20AWG s and Coaxial Components Contra-Helically Cabled Layers with Jute Fillers Color Coded and ed Wire Identification 60 C Flame Retardant Polyvinyl Chloride Jacket Voltage Rating: Conductors: Insulation: Color Code: 300V 60 C Bunch Stranded Bare Copper ASTM B 174-71 Flame Retardant Polyvinyl Chloride Color Coded and ed (UL) Type ETT CSA Type ETT CSA AWM NEC Compliant Size and of Components Cable Diameter Weight Hanging Maximum 14AWG (2.08mm²) (.82mm²) 20AWG PR Power / Signal, & Coax Composite ETT Traveling Cable 300V Steel Core Coax Fiber inches mm Lbs/MFt kg/km feet meters inches mm TCS414 4 ------- ------- ------ ------ 0.56" 14.4 182 271 900 274 3/32 2.4 TCS814 8 ------- ------- ------ ------ 0.68" 17.3 300 446 900 274 1/8 3.2 TCS1514 15 ------- ------- ------ ------ 0.91" 23.1 493 734 900 274 1/8 3.2 TCS618 ------- 6 ------- ------ ------ 0.49" 12.4 124 185 900 274 3/32 2.4 TCS1018 ------- 10 ------- ------ ------ 0.56" 14.2 195 290 861 262 3/32 2.4 TCS2018 ------- 20 ------- ------ ------ 0.71" 18.2 314 467 804 245 3/32 2.4 TCS3018 ------- 30 ------- ------ ------ 0.82" 20.8 436 649 900 274 1/8 3.2 TCS4018 ------- 40 ------- ------ ------ 0.92" 23.4 513 763 874 266 1/8 3.2 TCS4518 ------- 45 ------- ------ ------ 0.93" 23.6 576 857 900 274 1/8 3.2 TCS7518SPL ------- 75 ------- ------ ------ 1.19" 30.2 906 1348 773 236 1/8 3.2 TCSC20 ------- 14 3 ------ ------ 0.94" 24.0 438 652 612 187 3/32 2.4 TCSC27 4 21 1 ------ ------ 0.95" 24.1 529 787 900 274 5/32 4.0 TCSC37 4 31 1 ------ ------ 1.15" 29.2 745 1109 900 274 5/32 4.0 TCSC44 14 24 3 ------ ------ 1.33" 33.8 929 1382 753 230 5/32 4.0 TCSC45D 4 31 5 ------ ------ 1.27" 32.3 931 1385 776 237 5/32 4.0 TCSC48LO 4 30 7 ------ ------ 1.22" 31.1 836 1244 838 255 3/16 4.8 TCSC48HI 4 30 7 ------ ------ 1.22" 31.1 836 1244 838 255 3/16 4.8 TCSC51 4 45 1 ------ ------ 1.16" 29.5 833 1240 878 268 5/32 4.0 TCSC56 6 48 1 ------ ------ 1.24" 31.5 878 1307 826 252 5/32 4.0 TCSC58HI 4 40 7 ------ ------ 1.48" 37.6 1103 1641 622 190 5/32 4.0 TCSC58LO 4 40 7 ------ ------ 1.48" 37.6 1103 1641 622 190 5/32 4.0 TCSC59 4 49 3 ------ ------ 1.22" 31.0 666 991 791 241 5/32 4.0 TCSC60 7 27 13 ------ ------ 1.52" 38.6 883 1314 900 274 1/4 6.4

WIRE & CABLE CORPORATION Traveling Cable ETT Traveling Cable 300V Power / Signal, s & Coax For use in Elevator Hoistways in accordance with Article 620 of the NFPA 70 National Electrical Code Features: Flexible Copper Conductors VW-1 / FT1 Rated Steel Core per Mil-W-83420 Inner / Outer Synthetic Braid Optional s & Coaxial Cable Components Flexible Bunch Stranded Bare Copper Conductors 60 C Flame Retardant Polyvinyl Chloride Insulation Flame Retardant PVC Insulated Steel Core per Mil-W-83420 Inner / Outer Synthetic Braids Optional 20AWG s and Coaxial Components Contra-Helically Cabled Layers with Jute Fillers Color Coded and ed Wire Identification 60 C Flame Retardant Polyvinyl Chloride Jacket Voltage Rating: Conductors: Insulation: Color Code: 300V 60 C Bunch Stranded Bare Copper ASTM B 174-71 Flame Retardant Polyvinyl Chloride Color Coded and ed (UL) Type ETT CSA Type ETT CSA AWM NEC Compliant Size and of Components Cable Diameter Weight Hanging Maximum 14AWG (2.08mm²) (.82mm²) 20AWG PR Power / Signal, & Coax Composite ETT Traveling Cable 300V Steel Core OD Coax Fiber inches mm Lbs/MFt kg/km feet meters inches mm TCSC64 22 30 6 ------ ------ 1.61" 40.9 1425 2120 900 274 1/4 6.4 TCSC74 20 38 8 ------ ------ 1.50" 38.1 1478 2199 491 150 5/32 4.0 TCSC75 4 69 1 ------ ------ 1.34" 34.0 1090 1622 663 202 5/32 4.0 TCSC81 8 59 7 ------ ------ 1.55" 39.4 1340 1994 524 160 5/32 4.0 TCSC90 6 80 2 ------ ------ 1.47" 37.3 1355 2016 555 169 5/32 4.0 TCSC94 12 70 6 ------ ------ 1.65" 41.9 1613 2400 900 274 1/4 6.4 TCSC96 ------- 86 5 ------ ------ 1.42" 36.1 1213 1805 576 176 5/32 4.0 TCSX05 3 ------- ------- 2 ------ 1.09" 27.7 549 817 900 274 5/32 4.0 TCSX14 ------- ------- 6 2 ------ 1.10" 27.9 583 868 900 274 5/32 4.0 TCSX28 ------- ------- 13 2 ------ 1.34" 34.0 903 1344 776 237 5/32 4.0 TCSX36 17 ------- 8 3 ------ 1.61" 40.8 1419 2112 900 274 1/4 6.4 TCSX48HI 6 25 8 1 ------ 1.48" 25.9 1132 1684 900 274 1/4 6.4 TCSX48LO 6 25 8 1 ------ 1.48" 25.9 1132 1684 900 274 1/4 6.4 TCSX53 4 45 1 2 ------ 1.25" 31.7 754 1122 711 217 5/32 4.0 TCSX57 4 40 6 1 ------ 1.50" 38.1 1104 1643 612 187 5/32 4.0 TCSX61 7 27 13 1 ------ 1.64" 41.6 1385 2061 900 274 1/4 6.4 TCSX77 4 69 1 2 ------ 1.48" 37.6 1141 1698 532 162 5/32 4.0 TCSX77S 4 60 6 1 ------ 1.51" 38.4 1392 2071 900 274 1/4 6.4 TCSX750 20 38 8 1 ------ 1.54" 39.1 1590 2366 900 274 1/4 6.4 TCSXF33 5 14 4 2 4 1.32" 33.5 892 1327 784 239 5/32 4.0 TCSCC0420SH ------- ------- 4 ------- ------ 0.81" 20.5 324 482 900 274 1/8 3.2 TCSCC0618SH ------- ------- 6 ------- ------ 0.91" 23.1 450 670 900 274 5/32 4.0 TCSCC0620SH ------- ------- 6 ------ ------ 0.83" 1.2 382 21.1 900 274 1/8 3.2

WIRE & CABLE CORPORATION Traveling Cable ETT Traveling Cable 300V Power / Signal & s For use in Elevator Hoistways in accordance with Article 620 of the NFPA 70 National Electrical Code Features: Flexible Copper Conductors VW-1 / FT1 Rated Jute Core & Overall Synthetic Braid Optional s Flexible Bunch Stranded Bare Copper Conductors 60 C Flame Retardant Polyvinyl Chloride Insulation Jute Core & Overall Synthetic Braid Optional 20AWG s Contra-Helically Cabled Layers with Jute Fillers Color Coded and ed Wire Identification 60 C Flame Retardant Polyvinyl Chloride Jacket Voltage Rating: Conductors: Insulation: Color Code: 300V 60 C Bunch Stranded Bare Copper ASTM B 174-71 Flame Retardant Polyvinyl Chloride Color Coded and ed (UL) Type ETT CSA Type ETT NEC Compliant Size and of Components Cable Diameter Weight 14AWG (2.08mm²) (.82mm²) 20AWG Power/Signal, & Coax Composite ETT Traveling Cable 300V Coax Fiber inches mm Lbs/MFt kg/km TCJ0414 4 ------- ------- ------ ------ 0.48" 12.2 132 196 TCJ0618SPL ------- 6 ------- ------ ------ 0.43" 10.9 96 143 TCJ1018 ------- 10 ------- ------ ------ 0.54" 13.7 163 243 TCJ1618 ------- 16 ------- ------ ------ 0.64" 16.3 219 326 TCJ2018 ------- 20 ------- ------ ------ 0.71" 18.0 295 439 TCJ2418 ------- 24 ------- ------ ------ 0.73" 18.5 304 452 TCJ3018 ------- 30 ------- ------ ------ 0.83" 21.0 386 574 TCJ4018 ------- 40 ------- ------ ------ 0.92" 23.4 475 707 TCJC27 3 20 2 ------ ------ 0.92" 23.4 489 728 TCJC33SPL 3 22 4 ------ ------ 1.23" 31.2 707 1052 TCJC37 4 31 1 ------ ------ 1.15" 29.2 700 1042 TCJC38W 12 18 4 ------ ------ 1.22" 31.0 814 1211 TCJC45 4 39 1 ------ ------ 0.99" 25.1 639 951 TCJC45D 4 31 5 ------ ------ 1.27" 32.4 853 1269 TCJC51 4 45 1 ------ ------ 1.20" 30.5 757 1126 TCJC55D 4 41 5 ------ ------ 1.39" 35.3 917 1364 TCJC57 6 45 3 ------ ------ 1.39" 35.3 943 1403 TCJC59 4 49 3 ------ ------ 1.27" 32.2 912 1357 TCJC60 4 54 1 ------ ------ 1.26" 32.0 785 1168 TCJC66 4 56 3 ------ ------ 1.33" 33.8 945 1406 TCJC73 6 61 3 ------ ------ 1.41" 35.8 1076 1601 TCJC76 ------- 66 5 ------ ------ 1.42" 36.1 1017 1513 TCJC79SPL 7 64 4 ------ ------ 1.45" 36.8 1165 1734 TCJC86 4 76 3 ------ ------ 1.42" 36.2 1134 1687 TCJC96 ------ 86 5 ------ ------ 1.42" 36.1 1180 1756

WIRE & CABLE CORPORATION Hoistway Cable 600V Unjacketed Hoistway Cable Power / Signal, s & Coax For use in Elevator Hoistways in accordance with Article 620 of the NFPA 70 National Electrical Code Features: Flexible Copper Conductors Flame Retardant PVC; VW-1 & FT1 Rated Optional 20AWG s and Coaxial Cables Stratified Synthetic Binders Flexible Bunch Stranded Bare Copper Conductors Flame Retardant Polyvinyl Chloride Insulation Optional 20AWG s and Coaxial Cables Contra-Helically Cabled Layers Color Coded and ed Wire Identification Cable is Unjacketed Voltage Rating: Conductors: Insulation: Color Code: 600V/300V 60 C Bare Copper Bunch Stranded ASTM B 174-71 60 C Flame Retardant Polyvinyl Chloride Color Coded and numbered (UL) Hoistway Cable CSA Hoistway Cable NEC Compliant Size and of Components Cable Diameter Weight 14AWG (2.08mm²) (.82mm²) 20AWG Power/Signal, & Coax Composite Unjacketed Hoistway Cable 600V Coax Fiber inches mm Lbs/MFt kg/km HC0314 3 ------- ------- ------ ------ ------ 0.29" 7.4 59 88 HC0418 ------- 4 ------- ------ ------ ------ 0.25" 6.4 39 58 HC0718 ------- 7 ------- ------ ------ ------ 0.32" 8.1 68 101 HC0814SPL 8 ------- ------- ------ ------ ------ 0.45" 11.4 158 228 HC1018 ------- 10 ------- ------ ------ ------ 0.42" 10.7 97 144 HC1218 ------- 12 ------- ------ ------ ------ 0.46" 11.7 119 177 HC1414 14 ------- ------- ------ ------ ------ 0.60" 15.2 222 330 HC1418 ------- 14 ------- ------ ------ ------ 0.46" 11.7 135 201 HC1618 ------- 16 ------- ------ ------ ------ 0.53" 13.5 165 245 HC1918 ------- 19 ------- ------ ------ ------ 0.53" 13.5 184 274 HC2108SPL ------- 21 ------ ------ ------ ------ 0.65" 16.5 215 320 HC2418 ------- 24 ------ ------ ------ ------ 0.63" 16.0 232 345 HC3018 ------- 30 ------ ------ ------ ------ 0.67" 17.1 291 433 HC3718 ------ 37 ------ ------ ------ ------ 0.74" 18.7 358 533 HC4218 ------ 42 ------ ------ ------ ------ 0.84" 21.3 407 606 HC6118 ------ 61 ------ ------ ------ ------ 0.95" 24.0 591 879 HCC39 4 35 ------ ------ ------ ------ 0.82" 20.7 418 622 HCC42 14 24 2 ------ ------ ------ 0.96" 24.4 599 891 HCC48LO 6 25 8 ------ 1 ------ 0.87" 22.0 588 875 HCC49 4 45 ------ ------ ------ ------ 0.92" 23.4 515 766 HCC57 4 40 6 ------ 1 ------ 1.05" 26.7 606 902 HCC62 4 58 ------ ------ ------ ------ 1.02" 25.9 641 954 HCC71 6 61 2 ------ ------ ------ 1.14" 28.9 786 1170

WIRE & CABLE CORPORATION Compensating Cable Reduces sway and provides a damping effect for smooth operation at temperature ranges from 15C to 60C. Acceptable for use in the US where elevator rated speeds are less than 700 ft/min (3.56m/sec) James Monroe Compensating Cable Low carbon, electrically welded proof coil chain. Inner insulation of pressure extruded PVC Outer jacket of pressure extruded PVC Chain Trade Size Nominal Cable Diameter Maximum Hang Length Rec. Nominal Loop Width Approximate Cable Weight inches mm inches mm feet meters inches mm Lbs/ft kg/m JMC-C-18775 3/16 4.8 1.000 25.4 600 183 24 610 0.75 1.1 JMC-C-18710 3/16 4.8 1.250 31.8 600 183 24 610 1.00 1.5 JMC-C-25015 1/4 6.4 1.415 35.9 600 183 24 610 1.50 2.2 JMC-C-25020 5/16 7.9 1.650 41.9 600 183 26 660 2.00 3.0 JMC-C-31225 5/16 7.9 1.925 48.9 600 183 27 686 2.50 3.7 JMC-C-31230 5/16 7.9 2.250 57.2 600 183 27 686 3.00 4.5 Stationary Communications Cable 20 AWG s 80C 300V Stationary, ed Cables For Audio / Data Communications UL Listed, CSA Certified, NEC / CEC Compliant Reduces sway and provides a damping effect for smooth operation at temperature ranges from 15C To 60C. Acceptable for use in the US where elevator rated speeds are less than 700 ft/min (3.56m/sec) Sample Print: ** = of Pairs E67179 **/PR 20 AWG TYPE CL2 75C SHIELDED (UL) OR AWM 2464 80C 300V LL41103 CSA AWM I/II A/B 80C 300V FT4 Color Codes: Single Pair Cable (CC1X20SH Only) Pair 1: Red and White Multi-Pair Cables (CC2X20SH thru CC15X20SH) Pair 1: Black and Red Pair 2: Black and White Pair 3: Black and Green Pair 4: Black and Blue Pair 5: Black and Yellow Pair 6: Black and Brown Pair 7: Black and Orange Pair 8: Red and White Pair 9: Red and Green Pair 10: Red and Blue Pair 11: Red and Yellow Pair 12: Red and Brown Pair 13: Red and Orange Pair 14: Green and White Pair 15: Green and Blue Flexible, Stranded Bare Copper Conductors PVC Insulation Cabled with Drain Wire and Overall Foil Shield Gray PVC Jacket AC Voltage: REF Part No. of Pairs 300V 80C UL Type CL2 UL Style 2464 CSA AWM, I/II A/B FT4 Nominal Cable Diameter Approx. Cable Weight inches mm Lbs/MFt kg/km JM53313 CC1X20SH 1 0.191 4.9 22 33 JM50925 CC2X20SH 2 0.223 5.7 34 51 JM50912 CC3X20SH 3 0.297 7.5 50 74 JM53314 CC4X20SH 4 0.330 8.4 66 98 JM50913 CC6X20SH 6 0.394 10.0 91 135 JM50914 CC9X20SH 9 0.459 11.7 130 193 JM51059 CC12X20SH 12 0.517 13.1 165 246 JM50915 CC15X20SH 15 0.606 15.4 222 330

ELEVATOR CABLE DISTRIBUTORS New York City: 800-901-3140 Liberty Electrical & Elevator Supply T: 800-901-3140 / 718-482-8341 F: 718-482-8453 New York City: 718-644-8141 Triumph Electrical Supply Corp. T: 718-644-8141 F: 718-744-9725 California: 866-CED-ELEV CED Elevator & Electrical T: 866-CED-ELEV / 562-490-0900 F: 562-427-8429 Dallas/Ft Worth: 866-CED-ELEV CED Elevator & Electrical T: 866-CED-ELEV / 962-602-3245 F: 962-602-3255 Maryland: 866-CED-ELEV CED Elevator & Electrical T: 866-CED-ELEV / 443-542-2483 F: 667-200-5128 W&C COMPENSATING CABLE Chicago: 800-598-2444 PSI - Parts Specialist Inc. T: 800-598-2444 / 708-371-2444 F: 708-371-2477 Miami: 844-215-1586 Wurtec - Miami T: 844-215-1586 / 786-657-2539 Toronto: 888-457-2885 Wurtec - Canada T: 888-457-2885 / 416-757-2885 F: 416-757-2880 Vancover: 844-520-7888 Wurtec - Canada T: 844-520-7888 / 604-549-6982 F: 604-549-6989 WIRE & CABLE CORPORATION 800-316-8877 / 978-368-0131 Specializing in wire and cable for over 40 years. www.jamesmonroewire.com