Polypipe TDI. A comprehensive range of products designed to provide complete and economical solutions to cold bridging and other insulation problems.

Similar documents
TDIPG1 July Polypipe TDI. TDI Product Guide. For prices see the Polypipe Below Ground Drainage Trade Price List

Cavity closers, fire & acoustic stops Thermo-loc standard cavity closers Thermo-loc plus X and plus C cavity closers Thermo-loc

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

APPROVALS. Jabwall has been approved for this application since 1979, and was the first partial-fill insulation product to gain BBA approval.

Jabfill High Performance (HP)

Acoustray perimeter cavity stops

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.



Floors Walls Roofs. Jabfill Premium. APPLICATION: Full-fill Cavity Wall Insulation PRODUCTS: Vencel Resil Limited

A Handbook of thermal bridging details incorporating aircrete blocks

CI/SfB. October 2003

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

HP Partial Fill. Robust, long-lasting protection

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

Technical information & installation advice

Loft access doors. Loft access doors. 1 Call

50948-RHN Putney. 06 January This document includes: F30. Accessories/ sundry items for brick/ block/ stone walling. Code Section Revision Dated

A Handbook of thermal bridging details incorporating aircrete blocks

Wall lining Inner leaf blockwork. K106 Cavity Board. Flexible sealant STANDARD DETAILS FOR 115 MM INSULATION BOARD IN A 125 MM CAVITY

URSA MINERAL WOOL URSA Cavity Batts

Light steel frame walls

Multi-layer Insulation Blanket for

T-Barrier System. Masonry Applications. Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction

CALL TO TALK TO THE SAS TEAM

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

Multi-layer Insulation Blanket for Walls

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Multi-layer Insulation Blanket for Walls

T-Barrier System. Timber Frame Applications. Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction

URSA Cavity Batts URSA GLASSWOOL.

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

Insulation - Products

Leaving Certificate Revision Notes. Airtightness. Potential air leakage paths (the numbered points in section 2.1 give a description for

Suspended timber upper floors

Cavity Tray Application

Polyfoam Floorboard For thermal insulation of floors

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

June Non - Residential Refurbishment Separating floors

Multi-layer Insulation Blanket for Walls

0331 Brick and block construction

Part E robustdetails. robustdetails. September 2015 Update Pack. Dear Colleague,

Taking the Devil out of the Detail?

SP FIRESTOP SYSTEMS The purpose-made solution for cavity fire stopping

Product. Regulations. Rockwool Ltd Pencoed Bridgend CF35 6NY Tel: Fax: Agrément Certificate No 93/2884 Second issue*

TECHNICAL. Cavity Wall Partial - Fill Insulation. Stylite.

A handbook of thermal bridging details incorporating Porotherm blocks

tra-load Damp Proof Courses Product and Systems Overview

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Multi-layer Insulation Blanket for Walls

Isover Installation Guide

Multi-layer Insulation Blanket for use in Walls

Jabfloor 70 Floor insulation Suspended timber floor

June Residential Refurbishment Separating floors

GypLyner IWL Independent wall lining system

Owens-Corning Building Products (UK) Ltd P O Box 10 St Helens Merseyside WA10 3NS Tel: Fax:

fire, thermal & acoustic insulation

Cavity Wall Insulation 162 Roofing & Flooring Insulation 168 Fire Protection 172 Acoustic Protection 174

Building Design Data

June Residential Refurbishment Separating walls

March The Pocket Guide To Insulation

Part E robustdetails. robustdetails. January 2018 Update Pack

GypLyner UNIVERSAL Metal framed wall lining system

April Section 4.1. Ground Floors

June Residential New Build Timber Frame Walls

December The Pocket Guide To Insulation

GypLyner UNIVERSAL Metal framed wall lining system

4.1 Ground Floors. Ground floors. Ground floor design. Technical Support Team

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

URSA TF Roll URSA GLASSWOOL.

Building Regulations for the Conservation of Fuel and Power

Product & Installation Guide for New Build & Refurbishment Projects. exceeding the performance criteria of all current Building Regulations

Concrete Soffit Direct Fix

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM

Stylite. T-Beam Suspended Floor Insulation Technical Datasheet. Stylite T-Beam Floor Insulation

The Ufoil Range of Insulation

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

Jabfloor 70, 100, 150, 200, 250

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

June Residential New Build Render and cladding walls

Construction Standards PAGE

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

The Pocket Guide To Insulation May 2013

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide

Metal Web Floor System

GypWall AUDIO The ultimate sound insulating wall system

April Section Cladded Walls

April Section 4.3. Separating Floors

ROCKWOOL FLEXI Insulation Application Guide

Transcription:

31 9 Hn6 A comprehensive range of products designed to provide complete and economical solutions to cold bridging and other insulation problems.

Welcome to manufactures a full range of Insulated DPC s and Thermal Insulation Systems designed to meet today s increasing thermal and acoustic requirements in construction. s specialist knowledge ensures that its products comply with all necessary current Building Regulations. have always lead the way in manufacturing quality products to meet with the ever changing Building Regulations and, where required, thoroughly tested for Fire Integrity by Warrington Fire Research. We pride ourselves on being up to date, and in many cases ahead of, Building Regulations and the Fire Regulations throughout the United Kingdom. The product range includes Non-Combustible Insulated Closers Non-Combustible Insulated DPC s Non-Combustible Insulated Barriers Insulated Closer Sub Frame Kits Wall Closers, Damp Proofing and Insulation Insulated DPC s Fire Resistant and Insulated Lofthatches Flooring Sound Reducing Strips Flexibility is essential to the products and services we offer. can provide the specialist knowledge and the manufacture of bespoke products within both the Building Regulations and the Fire Regulations criteria.

Product Selector Closed Inner Blockwork returned into Open Straight build - Brickwork and Inner Blockwork Damcor Pages 6-7 Multicor Pages 12-13 Fire Retardent Requirement Stonecor Pages 8-9 Pyroflex Pages 10-11 Weathercor/F Pages 18-21 Thermocor Pages 14-15 Policor Pages 16-17 Rigidcor/F Pages 22-23 Hycor System 3000/F Pages 24-25 TDI Firestop 5 Pages 26-27 Pyrocor Pages 28-29 Party Wall More than one required to be closed TDI Stop Pages 30-31 Loft Hatches Flooring Products TDI 0.35 Loft Hatch Pages 34-35 TDI 0.25 Loft Hatch Pages 36-37 TDI Floor Muffle Pages 40-41 Pyroflex Pages 10-11 Sock Pages 32-33 TDI Pyrohatch Pages 38-39

Damcor Insulated DPC Supplied in 6 metre rolls No special fixings in use. No special installation techniques Easy to build as brickwork proceeds Easily cut with trowel or knife Lengths may be lapped with no loss of thermal efficiency CERTIFICATE No 93/2925 CERT. 165/6/7001 6 7 A complete and simple solution to thermal bridging where the cavity is closed. Combining advantages of expanded Polystyrene and Polyethylene DPC, Damcor is designed to prevent the problem of cold bridging around window and door openings in traditional cavity constructions. At these points in the structure, condensation with possible consequential staining and mould growth, can occur at the reveals due to the lack of insulation where the cavity is closed. The product is simply placed in the cavity with the DPC overlap trapped between the window/door frame and the exterior brickwork. No special fixings or installation techniques are necessary. The product can be rolled or folded. It is easily cut with a knife or trowel, and can be lap-jointed with no loss of thermal efficiency. No material need ever be wasted. Product Details Expanded Polystyrene to BS:3837:1986. Polyethylene DPC to BS 6515. Supplied in 6 metre rolls. 165mm DPC x 100mm insulation (8 per pack) 225mm DPC x 150mm insulation (6 per pack). Damcor can be manufactured to special order with DPC widths up to 800mm. Damcor is positioned in cavity prior to installation of window frame. It can be built in as the brickwork proceeds. Where lap joints occur, a minimum of 100mm DPC is recommended, with EPS insulation strips tightly butted. Plan Damcor s Brickwork Outer Leaf Damcor Blockwork Inner Leaf

Stonecor Insulated DPC Non-Combustible Insulation r Value of 0.76m² C/W k or λ Value of 0.033W/m C Flexible, is supplied in rolls Easy to build as brickwork proceeds Easily cut with trowel or knife Light and robust Economical CFC and HFC free Also suitable for use with wooden window frames CERTIFICATE No 01/3792 CERT. 167/6/7001 8 9 Plan Multi purpose super flexible compressible mineral wool insulated DPC combining the advantages of Icelandic lava stone wool with a traditional DPC. Stonecor meets today s thermal and acoustic requirements in construction. Icerock is manufactured in Iceland and completely environmentally friendly in manufacture and use, and is also non-combustible to 700 C. The Polyethylene DPC is manufactured to BS6515. Supplied in 10 Metre Rolls 5 Per Pack. 165mm DPC x 100mm insulation 225mm DPC x 150mm insulation. Stonecor can also be manufactured to special order with DPC widths up to 800mm. s Stonecor Installation/site work Stonecor is simply and easily installed. Its flexibility enables it to be built in with no problems as brickwork proceeds, similar to traditional DPC s. It must be firmly built in as work proceeds with the blockwork and the Icerock tightly butted together. Where a joint occurs a minimum lap of 100mm of DPC is recommended. Stonecor Brickwork Outer Leaf Blockwork Inner Leaf

Pyroflex Flexible Firebreak Insulated DPC Complies to all Building Regulations and Thermal Resistance Part L1 & L2 CFC and HFC free r value at 25mm is 0.73 k or λ value at 200 C is 0.06 k or λ value at 600 C is 0.16 Thermal conductivity of 128 kg/m 3 density measured at 20 Deg C to BS 874: 0.0342 W/MK 10 11 A complete and simple solution to thermal bridging for reveals and party wall situations. Combining the advantages of noncombustible insulation and high performance DPC. For installation in properties of three stories or above and multioccupancy developments. Flexible high performance DPC bonded with a non-combustible insulation achieving 120 minutes fire integrity. Manufactured in rolls in widths from 165mm to 800mm DPC, suitable for reveals and party wall situations achieving two hours fire integrity and required acoustic levels. Easy to build as brickwork proceeds, can be cut with knife, light and robust. Affording excellent insulating performances with thermal stability and low heat storage with high resistance to thermal shock. Pyroflex has good sound absorption, flexible and resilient with good resistance to tearing, Pyroflex is free of binder or lubricant. Pyroflex installed

Multicor Insulated Closer r value of 1m 2 kw k value of 0.03w/m Complies with Building Regulations Part L1a Manufactured in 2.44 metre lengths Fits all cavity widths up to 100mm wide Suitable for any window size, one size fits all Complete with flexible weatherseal Corners and brick ties now available Applied 12 13 TDI Multicor is an insulated cavity closer that is suitable for use in severe weather conditions. One size fits all - can be cut to fit any window size. The TDI Multicor insulated cavity closer is manufactured from high quality PVCu and comes complete with flexible weatherseal and fits all cavity widths up to 100mm wide, one size fits all. Very competitively priced Multicor can be built in at construction stage or retro fit, there are no clips required with Multicor cavity closer, simply nail to brickwork. Multicor is designed to be suitable for use with both PVCu and wooden frames. Now available with corners and brick ties for superior fixing. Simple to cut - one size fits all Diagram Brickwork Outer Leaf TDI Multicor TDI Multicor Blockwork Inner Leaf Installation

Thermocor CC Insulated Closer Excludes damp Eliminates the cold bridge No special installation techniques Easily cut with a knife Very economical in use and price CERT. 170/6/7001 14 15 Diagram Thermocor CC is manufactured from an expanded Polystyrene core completely enclosed in Polyethylene DPC for maximum protection against water penetration coupled with insulation. Standard sizes 50, 65, 75, 90, 100 & 125 mm. 2.44 metre length, in packs of 20. Can be manufactured up to 200mm wide. TDI plastic fixing clips are available if required. Jamb Plaster Board Thermocor Thermocor Installation/site work An overlap of the DPC allows Thermocor CC to be fixed to the frame if required. Expanded Polystyrene is CFC and HFC free to BS3837. Thermocor CC can either be fixed as building progresses or placed in the cavity later. Where window frames are built in Thermocor CC should be fastened to window jamb in the appropriate position first. must be fixed directly to the masonry and set in at least 30mm from the inner surface of the outer leaf of the wall. Brickwork Outer Leaf Thermocor Blockwork Inner Leaf

Policor CC Insulated Closer Eliminates cold bridging No special fitting required Economical in use and price Energy efficient CFC and HFC free Traditional DPC 16 17 A complete and simple solution to closing and insulating the cavity in external wall openings. Combines the advantages of Polystyrene and Polyethylene DPC, plus a timber core. Specially formulated to provide a simple, complete and economical solution to cold bridging problems. It consists of a pliable Polystyrene to BS 3837 and Polyethylene DPC to BS 6515 with an exterior grade timber insert. Stainless steel wall ties are provided with provision for adjustable spacing, ensuring that Policor is held firmly in position. The wall tie retaining strip will accommodate most types of wall ties. The timber core receives traditional fixings and it is recommended that plaster board or beading be nailed to the core and also fixed to the inner blockwork and then plastered over, thus eliminating any risk of the plaster cracking in the reveal. As well as being robust, Policor CC is pliable and can be pushed or built into irregular cavities without any danger of it being cracked or damaged. Available in 50, 65, 75 & 100mm wide, in 2.44 metre lengths with 15 lengths per pack. Plan Timbercore Insulation Timbercore Insulation Policor CC Tie Policor CC Tie Brickwork Outer Leaf Blockwork Inner Leaf

Weathercor/F Insulated Closer r Value of 0.91m² C/W k or λ Value of 0.033W/m C Complete with flexible weatherseal Available for all cavity widths up to 240mm wide Very competitively priced Cuts installation time by 80% approx. Build in at construction stage No clips required, simply nail to brickwork Made from high quality PVCu Suitable for use with wooden frames Corners and brick ties now available CERT. 166/6/7001 18 19 Weathercor/F is manufactured from non-combustible insulation in a PVCu profile incorporating a neoprene weatherstrip. It has a 30 minute fire integrity, is suitable for severe weather condition areas. It is supplied in 2.44 metre lengths and in packs of 10. widths are available from 50mm to 240mm. Can be manufactured to suit step reveal applications. Now available with corners and brick ties for superior fixing. Weathercor/F installed Diagram Jamb Weathercor Weathercor Weathercor Plaster Board Brickwork Outer Leaf Blockwork Inner Leaf

Weathercor/F Sub Frame System r Value of 0.91m² C/W k or λ Value of 0.033W/m C Complete with flexible weatherseal Very competitively priced Cuts installation time by 80% approx. Build in at construction stage No clips required, simply nail to brickwork Made from high quality PVCu Suitable for use with wooden frames CERT. 166/6/7001 20 21 Weathercor/F is manufactured from non-combustible insulation in a PVCu profile incorporating a neoprene weatherstrip. It has a 30 minute fire integrity, is suitable for severe weather condition areas. It is supplied in 2.44 metre lengths and in packs of 10. widths are available from 50mm to 100mm. Supplied in kit form cut to size complete with corners, bracing and brick ties. Weathercor/F installed Ready to install as a sub frame kit that can be built around. Can be manufactured to suit step reveal applications. Jamb Diagram Weathercor Weathercor Weathercor Plaster Board Brickwork Outer Leaf Blockwork Inner Leaf

Rigidcor/F Insulated Closer/ Barrier r Value of 0.91m² C/W k or λ Value of 0.033W/m C Available in 5 sizes 50mm, 75mm, 85mm, 100mm and 120mm in 3 metre lengths Cuts installation time by 80% approx Build in at construction stage Minimum thermal resistance to Part L1 & L2 Conforms to building regulations Very competitively priced Suitable for any sill options Complete with flexible weatherseal CERTIFICATE No 03/4069 CERT. 168/6/7001 22 23 Insulated cavity closer/cavity barrier which achieves a minimum of 30 minutes fire integrity and is suitable for severe weather condition areas, all in one product. Diagram Made from high quality PVCu with corners, joining pieces and clip in adjustable wall ties available to eliminate all waste. Accepts any size or style of window system and does not require dry lining or plaster to conform to building regulations. Supplied in 3 metre lengths, 5 per pack. sizes 50mm, 75mm, 85mm, 100mm and 120mm. Available in 6 metre lengths to special order. Jamb Plaster Board Rigidcor/F Clip in adjustable wall ties Clip in adjustable wall ties Rigidcor/F Can be manufactured to suit step reveal applications.

Hycor System 3000/F Subframe System r Value of 0.91m² C/W k or λ Value of 0.033W/m C Available in 5 sizes 50mm, 75mm, 85mm, 100mm and 120mm Cuts installation time by 80% approx Build in at construction stage Minimum thermal resistance to Part L1 & L2 Conforms to building regulations Very competitively priced Suitable for any sill options Complete with flexible weatherseal CERTIFICATE No 03/4069 CERT. 168/6/7001 24 25 Insulated cavity closer/cavity barrier which achieves a minimum of 30 minutes fire integrity and is suitable for severe weather condition areas, all in one product. Made from high quality PVCu with corners, joining pieces and clip in adjustable wall ties available to eliminate all waste. Accepts any size or style of window system and does not require dry lining or plaster to conform to Building Regulations We supply in kit form cut to size and ready to install as a sub frame that can then be built around. sizes 50mm, 75mm, 85mm, 100mm and 120mm. Can be manufactured to suit step reveal applications. Diagram Jamb Clip in adjustable wall ties Clip in adjustable wall ties System 000/F System 000/F Plaster Board

TDI Firestop Insulated Closer r Value of 1.36m2 C/W k Value of 0.033W/m C Damp proofs Insulates Fire stops Ideal for timber framed buildings Eliminates the cold bridge No special installation techniques Easily cut with a knife incorporates Polyethylene DPC to British Standard BS6515 CERT. 169/6/7001 26 27 Diagram Manufactured from a non-combustible ice rock mineral wool core completely enclosed in Polyethylene DPC for maximum protection against water penetration coupled with maximum insulation. Jamb Firestop TDI plastic fixing clips Firestop TDI Firestop is a non-combustible, ice rock mineral wool core fully enclosed in a traditional DPC to ensure complete damp-proofing and insulation, plus a 40mm weather flap. Plaster Board Available in 2.44 metre lengths in any width from 50mm to 200mm wide. Standard widths are 50mm, 65mm, 75mm, 90mm, 100mm, 125mm, 20 lengths per pack. Fixing clips included. TDI plastic fixing clips Firestop Brickwork Outer Leaf Blockwork Inner Leaf

Pyrocor Flexible Firebreak Insulated Closer Complies to all building regulations and thermal resistance Part L1 & L2 r value is 1.46 k or λ value at 200 C is 0.06 k or λ value at 600 C is 0.16 Thermal Conductivity of 128 kg/m³ density measured at 20 Deg C to BS 874: 0.0342 W/MK Can be used as a horizonal and a vertical cavity barrier. 28 29 Diagram A complete and simple solution to thermal bridging combining advantages of non-combustible insulation and high performance DPC. For installation in properties of three stories or above and multioccupancy developments. Pyrocor Closer is enclosed in a high performance Polymeric DPC suitable for all properties where two hours fire integrity is recommended. Pyrocor damp proofs, insulates, firestops and eliminates the cold bridge and is available in all cavity widths, supplied in 2.44 metre lengths with fixing clips, it can easily be cut with a knife and there are no special installation techniques. Pyrocor can be used as both a horizontal and vertical cavity barrier. Jamb Pyrocor Plaster Board TDI plastic fixing clips Pyrocor TDI plastic fixing clips Pyrocor Brickwork Outer Leaf Blockwork Inner Leaf

TDI Stop Insulated Closer r Value of 0.76m² C/W on 100mm width insulation r Value of 0.56m² C/W on 150mm width insulation k or λ value of 0.033W/m C Flexible, is supplied in rolls Easy to build as brickwork proceeds Easily cut with a knife Light and Robust Economical CERT. 193/6/7001 30 31 60 minutes fire integrity and acoustic insulated DPC for partywalls. A super flexible and compressible insulated DPC combining the advantages of Icelandic Lava Stone Wool with a traditional DPC complying to all acoustic requirements for party walls and abutments giving 60 minutes fire integrity. Stop meets today s thermal and acoustic requirements in construction. Icerock is manufactured in Iceland, it is completely environmentally friendly in manufacture and use, and is also noncombustible. The Polyethylene DPC is manufactured to BS6515. Manufactured in DPC widths from 165mm to 500mm and in insulation widths from 100mm to 450mm insulation thickness from 50mm to 125mm 7.5metre rolls 5 rolls per pack. Installation/site work Stop is simply and easily installed. Its flexibility enables it to be built in with no problems as brickwork proceeds, similar to traditional DPC s. It must be firmly built in as work proceeds with the blockwork and the Icerock tightly butted together. Where a joint occurs a minimum lap of 100mm of DPC is recommended. Diagram Blockwork Party Wall Stop Blockwork Party Wall

Sock Fire and Acoustic DPM Sock/Barrier Provides 2 hours fire integrity and insulation in a concealed cavity. Easy to use. Can be friction or mechanically fixed. The DPM is manufactured to BS EN 13967:2004. Applied 32 33 The TDI Sock is designed to restrict the spread of fire and smoke in concealed cavities particularly within external masonry or timber framed walls. This product also complies with acoustic requirements of Building Regulations Part E. Easy to use, acoustic and fire valuation for separating floor junction in timber joists, concrete, steel concrete composite and external flanking wall junction that incorporates a cavity tray. Can be friction or mechanically fixed. Manufactured from 50mm to 100mm deep x 100mm to 300mm wide and supplied in 2.44 metre lengths. Other sizes available to order. The Superior Quality Damp Proof Membrane is manufactured to BS EN 13967:2004. The Sock is tested by Warrington Fire Research, achieving two hours fire integrity at a furnace temperature of 1049ºC, in accordance with Building Regulations requirements BS4760 Part 20. Separating Floor - Steel Timber I-Joists 1. External (flanking) wall junction Close with TDI Fire & Acoustic Sock/Barrier Separating Floor - Concrete External (flanking) wall junction Sketch shows FFTP5 type floating floor treatment and CT1 type ceiling treatment Close with TDI Fire & Acoustic Sock/Barrier Separating Floor - Steel concrete composite External (flanking) wall junction - steel or timber frame inner leaf Sketch shows FFT1 type floating floor treatment All voids between slab and inner leaf filled with TDI Fire & Acoustic Sock/Barrier Close TDI Fire & Acoustic with TDI Fire Sock/Barrier & Acoustic Where floor profiles are at a right angle to walls, voids to be filled Sock/Barrier Close with TDI Fire & Acoustic Sock/Barrier Particular attention should be paid to Building Regulation Part B - Fire Safety. Separating Floor - Steel Timber I-Joists Separate wall junction Separating Floor - Concrete 1. Separating wall junction Sketch shows FFTP5 type floating floor treatment and CT1 type ceiling treatment Close with TDI Fire & Acoustic Sock/Barrier Close with TDI Fire & Acoustic Sock/Barrier Separating Floor - Steel concrete composite External (flanking) wall junction - masonry inner leaf Sketch shows FFT1 type floating floor treatment Close with TDI Fire & Acoustic Sock/Barrier TDI Fire & Acoustic Sock/Barrier All voids between slab and inner leaf fitted with TDI Fire & Acoustic Sock/Barrier Where floor profiles are at a right angle to walls, voids to be filled Close with TDI Fire & Acoustic Sock/Barrier Particular attention should be paid to Building Regulation Part B - Fire Safety.

TDI 0.35 Loft Hatch CERT. 153/6/7001 34 35 Achieves 0.35 U-value to comply with new Building Regulation document L1 & L2 as required by the robust detail. Clear opening 600mm x 532mm (Overall size 733 x 656mm). Injection moulded Rigid Polypropylene outer hatch, no welded corners. Attractive moulded ceiling architrave surround and trap door sculpture, easy access for loft ladders, simple to fit, supplied in a box with fitting instructions. Meets all Building Regulations for insulated loft hatches. Factory assembled for easy fitting. Robust Details 1st April 2002. DETR Building Regulations loft hatch 8.04. Ensure that loft hatch is fully draught stripped. Counterbearers and boarding should be provided if access to loft is required. Note that U-value through loft hatch must be no worse than 0.35Wm2K (poorest acceptable U-value). Dimensions C A E F D B A B C D E F 733mm 656mm 639mm 562mm 600mm 532mm

TDI 0.25 Loft Hatch Applied 36 37 The TDI 0.25 Loft Hatch is manufactured to comply with the extra 20% energy efficiency required by the conservation of fuel and power approved document L1A, April 2006. Clear opening 600mm x 532mm (Overall size 733 x 656mm). Injection moulded Rigid Polypropylene outer hatch, no welded corners. Attractive moulded ceiling architrave surround and trap door sculpture, easy access for Loft Ladders, simple to fit, supplied in a box with fitting instructions. Meets all Building Regulations for insulated loft hatches. Factory assembled for easy fitting. Robust Details 1st April 2002. DETR Building Regulations loft hatch 8.04. Ensure that loft hatch is fully draught stripped. Counterbearers and boarding should be provided if access to loft is required. Note that U-value through loft hatch must be no worse than 0.35Wm2K (Poorest acceptable U-value). Dimensions C A E F D B A B C D E F 733mm 656mm 639mm 562mm 600mm 532mm

TDI Pyrohatch CERT. 153/6/7001 38 39 Achieves 0.35 U-value to comply with new Building Regulation document L1 & L2 as required by the robust detail. Clear opening 600mm x 532mm (Overall size 733 x 656mm). Injection moulded Rigid Polypropylene outer hatch, no welded corners. Attractive moulded ceiling architrave surround and trap door sculpture, easy access for loft ladders, simple to fit, supplied in a box with fitting instructions. Meets all Building Regulations for insulated loft hatches. Factory assembled for easy fitting. Unique catch, outer hatch can only be closed when inner hatch has been closed, the inner hatch has a white powder coated finish. TDI Pyrohatch system was tested at Warrington Fire Research and was found to be in accordance with the requirements of BS476 Part 20 achieving over 60 minutes integrity and insulation at a furnace temperature of 945ºC. Dimensions C A E F D B A B C D E F 733mm 656mm 639mm 562mm 600mm 532mm

TDI Floor Muffle Enclosed Sound Reducing Strip 3db improvement in the airborn sound insulation. 3db improvement in the impact sound insulation. Simple and fast to install No specialist tools needed CERTIFICATE No 06/4371 CERT. 316/6/7001 40 41 TDI Floor Muffle complies to current Building Regulations and is BBA certified. TDI Floor Muffle comprises of a 20mm thick enclosed sound reducing strip, which is simply stapled to the top of the joists and sits between the timber floor joists and the floorboards. The floorboards can then be screwed directly through the floor muffle. It is quick to install, no special tools required. When tested at the BRE, the product compressed by 50% and no further insulation was required to achieve 41dB as required by Building Regulations. TDI Floor Muffle is designed for use in domestic houses only.

Product Certification Products Damcor Insulated DPC P P Stonecor Insulated DPC P P P TDI Stop Insulated DPC P P Thermocor Closer Policor Closer P TDI Firestop Closer P P 42 43 Multicor Closer Applied Weathercor/F Closer P P Rigidcor/F Closer P P P Hycor System 3000/F Subframe Kit P P P Pyroflex Firebreak Product Pyrocor Firebreak Product Sock Firebreak Product Applied TDI 0.25 TDI Loft Hatch Applied TDI 0.35 TDI Loft Hatch P TDI Pyrohatch Loft Hatch P TDI Floor Muffle Floor Insulation P P P

Unit 3 Unity Complex Dale Rd North Darley Dale Matlock Derbyshire DE4 2HX Tel: +44 (0) 1629 733177 Fax: +44 (0) 1629 732779 E-mail: tdi.sales@polypipe.com Website: www.polypipe.com Available from