Estimation of near-saturated hydraulic conductivity values using a mini disc infiltrometer

Similar documents
The Decline of Soil Infiltration Capacity Due To High Elevation Groundwater

Comment on the paper Field observations of soil moisture variability across scales by Famiglietti et al.

Impact of Compaction State and Initial Moisture on Infiltration Characteristic of Soil

The Simulation of Pore Size Distribution from Unsaturated Hydraulic Conductivity Data Using the Hydraulic Functions

Parameter estimation of unsaturated soil hydraulic properties from transient ow processes 1

SOIL HYDRAULIC CONDUCTIVITY IN A NON-WHEEL TRAFFIC CORN ROW, A WHEEL TRAFFIC CORN ROW, AND A RECONSTRUCTED PRAIRIE

Effects of Different Land Use on Soil Hydraulic Properties

Laboratory Assignment #3

Mini Disk Infiltrometer

Estimating Saturated Hydraulic Conductivity from Surface Ground-Penetrating Radar Monitoring of Infiltration

Simplified Procedure for Unsaturated Flow Parameters

An Introduction into Applied Soil Hydrology

WATER MASS BALANCE IN THE CASE OF VERTICAL INFILTRATION

SOIL MOISTURE CHARACTERISTICS IN UPPER PART OF HINDON RIVER CATCHMENT

Parameter estimation using the falling head infiltration model: Simulation and field experiment

Mini Disk Infiltrometer

Toward Sustainable Agriculture: Soil Management and Hydraulic Properties

Interpretation of ponded infiltration data using numerical experiments

Laboratory Assignment #3

Estimating unsaturated soil hydraulic properties from laboratory tension disc infiltrometer experiments

Volume 2, Issue 2: (2012) (Received: December 17, 2011; Accepted: February 01, 2012; Published: March 30, 2012) ISSN

When a predetermined discharge of a subsurface

TRICKLE IRRIGATION AS A SIMPLE TOOL TO ESTIMATE SATURATED HYDRAULIC CONDUCTIVITY

Determination of Hydrophobicity Index: Standard and Mini Disk Infiltrometers

Spatial Analysis of Infiltration Experiment

Methods for Measuring Hydraulic Conductivity

Rational Method for In-Situ Prediction of the Vertical Saturated Hydraulic Conductivity of Soils

Turfgrass and Environmental Research Online

PRACTICE NOTE 1: In Situ Measurement of Hydraulic Conductivity

A Normalized Function for Predicting the Coefficient Permeability of Unsaturated Soils

INFLUENCE OF RAINFALL PATTERN ON THE INFILTRATION INTO LANDFILL EARTHEN FINAL COVER

Comparison of three measurement methods of saturated hydraulic condutivity

ON THE CHOICE OF SOIL HYDRAULIC MODELS IN LAND-SURFACE SCHEMES

Water Resources Engineering. Prof. R. Srivastava. Department of Water Resources Engineering. Indian Institute of Technology, Kanpur.

Water Related Soil Properties

The role of the initial soil water content in the determination of unsaturated soil hydraulic conductivity using a tension infiltrometer

AN ABSTRACT OF THE THESIS OF

The saturated hydraulic conductivity (K s ) of a porous medium is a critically

Hassan Abbaspour 1*, Mehdi Shorafa 2, Mehdi Rashtbari 3

Design, construction and performance of a pressure chamber for water retention curve determination through traditional and nuclear methods

WETTING AND DRYING UNSATURATED SOIL DIFFUSIVITY MEASUREMENTS IN LABORATORY DANIEL BUSULWA MABIRIZI. Bachelor of Science in Surveying

Water Budget IV: Soil Water Processes P = Q + ET + G + ΔS

Philip Model Capability to Estimate Infiltration for Solis of Aba, Abia State

Agry 560 Exam November 7, 2002 (135 points) (10 pages)

FLOW AND DISTRIBUTION OF WATER IN UNSATURATED, FRACTIONALLY-WET POROUS MEDIA SYSTEMS

Vadose/unsaturated. (Basic concepts) Lucila Candela ERASMUS

AN APPROACH TO MODELING AIR AND WATER STATUS OF HORTICULTURAL SUBSTRATES

An infiltration model development and evaluation for pitcher irrigation system

Stormwater Retention Pond Recovery Analysis

Study of the behavior of materials with fines content in heap leaching processes

Florida State University Libraries

Field measurement of soil sorptivity and hydraulic conductivity

Chapter 18 Leaching of Contaminants to Groundwater

Approaches to characterize the degree of water repellency

StormCon August 2017

Standard Operating Procedure No. 71. Guelph Permeameter Measurements of Hydraulic Conductivity

Standard Guide for Comparison of Field Methods for Determining Hydraulic Conductivity in the Vadose Zone 1

THE EFFECT OF HYSTERESIS ON SOIL WATER DYNAMICS DURING SURFACE TRICKLE IRRIGATION IN LAYERED SOILS

CURRICULUM VITAE. 1. Name: Paraskevi A. LONDRA

Applying Polyacrylamide (PAM) to Reduce Seepage Loss of Water Through Unlined Canals

A MODEL FOR SOIL OXYGEN DELIVERY TO WASTEWATER INFILTRATION SURFACES. J. Erickson, E. J. Tyler* ABSTRACT

Explaining soil moisture variability as a function of mean soil moisture: A stochastic unsaturated flow perspective

Cold Desert Evapotranspiration Cover System Design Evaluation

Simplified Forms of Surface Runoff Estimation Method for Silt- Loam Soils Suat Irmak, Soil and Water Resources and Irrigation Engineer, Professor

Sedimentation and Remote Sensing

HOW WATER MOVES IN SOIL Beth Guertal Auburn University

Determination of soil hydraulic properties of potential low and intermediate level waste disposal sites in Bulgaria

Infiltration. ro ock and soil. Soil. Unsa aturated Zone. Hydraulic properties? Rock. soil. pores filled with air and water

CURRICULUM VITAE 1. Personal details 2. Work address: 3. Education

Applications of Hydraulic Properties Models on Microscopic Flow in Unsaturated Porous Media

PROBLEMS & CONSIDERATIONS IN DETERMINING PHYSICAL PROPERTIES OF HORTICULTURAL SUBSTRATES

A soil moisture accounting-procedure with a Richards equation-based soil texturedependent

ERDC/GSL TN-17-1 May 2017 A Spreadsheet for Estimating Soil Water Characteristic Curves (SWCC) By Ghada Ellithy

Sperry & Love s hydraulic model

Evaluation of Different Soil Water Potential by Field Capacity Threshold in Combination with a Triggered Irrigation Module

TOOLS AND TIPS FOR MEASURING THE FULL SOIL MOISTURE RELEASE CURVE

SOIL WATER CHARACTERISTIC CURVES FOR SOLID WASTE

The ring infiltrometer described by Bouwer (1986) is the most commonly

A fully-automated apparatus for the determination of three types of hydraulic

VADOSE/W 2D Tutorial

APPENDICES SYMBOLS AND NOTATION GLOSSARY. Copyright 2003 David G Tarboton, Utah State University

Characterization and Modeling of Macro-pore Flow in Heap Leach and Waste Rock Material 1

Global Journal of Engineering and Technology Review

Green-Ampt Infiltration Parameters in Riparian Buffers

Lecture Notes on Groundwater Hydrology. Part 1

VADOSE/W 2D Tutorial

Computation of excess stormflow at the basin scale. Prof. Pierluigi Claps. Dept. DIATI, Politecnico di Torino

Evaporation from soil surface in presence of shallow water tables

APPLICABILITY OF CARMAN-KOZENY EQUATION FOR WELL CONSOLIDATED SAMPLES

MODELS TO ESTIMATE SOIL MOISTURE RETENTION LIMITS AND SATURATED HYDRAULIC CONDUCTIVITY

Eduardo Bautista, Ph.D. Research Hydraulic Engineer USDA-ARS U.S. Arid Land Agricultural Research Center Cardon Lane, Maricopa, AZ 95138

The Soil Water Characteristic - Introduction and Measurement

New methods for hydraulic characterization of mine waste and cover system materials

Determining hydraulic properties of concrete and mortar by inverse modelling

Application Note. MadgeTech, Inc. (603) Phone (603) Fax 6 Warner Road Warner NH 03278

A method for computing infiltration and redistribution in a discretized moisture content domain

Evaluation of water flow and infiltration using HYDRUS model in sprinkler irrigation system

The variably saturated flow process in soils is a highly nonlinear

Comparison of permeability test methods to characterize on-site rainwater infiltration

Transcription:

Water Utility Journal 16: 97-104, 2017. 2017 E.W. Publications Estimation of near-saturated hydraulic conductivity values using a mini disc infiltrometer G. Kargas, P.A. Londra * and J.D. Valiantzas Laboratory of Agricultural Hydraulics, Department of Natural Resources Management and Agricultural Engineering, School of Agricultural Production, Infrastructures and Environment, Agricultural University of Athens, 75 Iera Odos, Athens, Greece * e-mail: v.londra@aua.gr Abstract: Key words: Laboratory experiments were conducted using a mini disc infiltrometer to obtain infiltration data in various negative pressure heads in two disturbed porous media, a Loam (L) and a Silty Clay Loam soil (SiCL), in order to determine the soil hydrodynamic properties close to natural saturation. Also, the experimental determination of water retention curve, θ(h), and saturated hydraulic conductivity, K s, of the porous media, using a steady head or variable head permeameter, was performed. To estimate near-saturated hydraulic conductivity, K h0, for transient flow from disc infiltrometer data, a two-term infiltration equation was used. The coefficients of the two terms were determined by direct nonlinear fitting on cumulative infiltration data and by two linear fitting techniques. The coefficient of one term of the two-parameter equation relates to the hydraulic conductivity, K h0, and the other to sorptivity, S. The analysis showed that the method of linearization by differentiating cumulative infiltration with respect to the square root of time, taking into account the perturbation during the infiltration, allows a better check of the validity of the twoparameter equation. Furthermore, the knowledge of the van Genuchten (1980) parameters, a and n, for a given soil type, is required to calculate hydraulic conductivity values near saturation. These values were determined taking into account both the experimental infiltration and θ(h) data using the methods of Zhang (1997) and Dohnal et al. (2010). These results were compared to the corresponding ones obtained using θ(h) values proposed, for the same soils used, by the mini disc infiltrometer user manual (Decagon Devices, Inc., 2007). Comparative evaluation among K h0 calculation methods showed that Dohnal et al. (2010) equation and the method proposed by the infiltrometer user manual gave similar values of K h0. Infiltration, mini disc infiltrometer, hydraulic conductivity 1. INTRODUCTION The tension disc infiltrometer allows measurements of infiltration with a constant and small negative pressure head, h 0, at the soil surface, and has been extensively used in recent decades to measure the near-saturated hydraulic conductivity, K h0, and sorptivity S (Smettem and Clothier, 1989; Warrick, 1992; Haverkamp et al., 1994; Smetten et al., 1994; Vandervaere et al., 2000a). Various methodologies have been proposed to determine K h0 and S from three-dimensional infiltration experimental data from circular source at soil surface using the tension disc infiltrometer. Among these, some are based on steady-state flow data, and others on transient flow data (Clothier and White, 1981; Smettem and Clothier, 1989; Ankeny et al., 1991; Reynolds and Elrick, 1991; Haverkamp et al., 1994; Zhang, 1997; Vandervaere et al., 2000b; Latorre et al., 2013). In case of steady-state flow from circular source with constant negative pressure head at soil surface, the analytical solution of Wooding (1968) is used. Wooding equation is applied by assuming that the soil is homogenous and isotropic and the initial water content is uniform. Hydraulic properties can be determined either by steady-state infiltration experiments using multiple-discs, or by single-disc infiltration experiments with multiple tensions (Lazarovitch et al., 2007). Wooding approach uses a two-parametric model for determining the hydraulic conductivity (Gardner, 1958). However, it is quite difficult to obtain reliable values of S using infiltration data by disc infiltrometer since there is difficulty to determine the required short time where gravity is ignored (Zhang, 1997). Due to uncertainties about the time at which a steady-state infiltration regime is attained,

98 G. Kargas et al. together with the fact that useful information is lost by ignoring the transient stage, several researchers use a transient three-dimensional infiltration equation for disc infiltrometers (Vandervaere, 2002). Although, several expressions for transient infiltration (Warrick, 1992; Haverkamp et al., 1994; Zhang, 1997) have in common the following two-term cumulative infiltration equation analogous to Phillip (1957) equation: I = C1 t + C2t (1) where the coefficients C 1 (L T -0.5) and C 2 (L T -1 ) differ (Vandervaere, 2002). Warrick (1992) found C 1 and C 2 expressions for small times by assuming a constant diffusivity. Haverkamp et al. (1994) related C 1 and C 2 to S and Κ h0 for small and medium times as follows: C 1 =S (2) C 2 β = K + 3 r 2 h0 γs 2 ( θ θ f ) (3) where the subscript f refers to the initial conditions, r is the disc radious, γ is a proportionality constant equal to 0.75, and coefficient β lies between 0 and 1. Vandervaere et al. (2000b) introduced a criterion to check K h0 calculation reliability by the method of Haverkamp et al. (1994): r γ C 2 1 2 ( θ θ f ) C < 2 (4) In the case where the abovementioned criterion is satisfied, then Eq. (3) can be used to calculate K h0. Coefficients C 1 and C 2 of Zhang (1997) method, at any infiltration time, are obtained by fitting infiltration data vs time in Eq. (1) using least squares optimization technique (Marquart, 1963). Zhang (1997) proposed linear relationships between the coefficients of Eq. (1) and the sorptivity S and the near-saturated hydraulic conductivity K h0 : C = SA (5) 1 1 C = K A (6) 2 h0 2 where Α 1 and Α 2 are dimensionless parameters. Empirical expressions have been proposed to calculate A 1 and A 2 parameters (Zhang, 1997). Because the main purpose of this study is the estimation of K h0, the necessary parameter A 2 can be calculated using the following equations: A 2 = 11.65 ( n0.1 1)exp 2.92( n 1.9)ah 0 αh 0 ( ) 0.91, n > 1.9 (7) A 2 = 11.65 ( n0.1 1)exp 7.5( n 1.9)ah 0 αh 0 ( ) 0.91, n<1.9 (8) where α and n are the van Genuchten (1980) equation parameters, h 0 is the infiltrometer negative pressure head, and r 0 is the disc infiltrometer radius.

Water Utility Journal 16 (2017) 99 However, Vadervaere et al. (2000a) had reported that the calculation of C 1 and C 2 parameters by direct nonlinear fitting of Eq. (1) on experimental data can provide fitted values for C 1 and C 2, even if these values have no physical meaning, e.g., negative C 2 value. So, negative K h0 is a physical impossibility indicating a problem with the data set. To overcome this problem, various linear fitting techniques of Eq. (1) have been proposed to detect possible inadequacy of Eq. (1) as well as scattering of data points. Smiles and Knight (1976) proposed linearizing of Eq. (1) by dividing both sides by t, giving the equation: I C1 C2 t t = + (9) and then plotting I/ t as a function of t. Thus, it is easy to determine C 1 as the intercept and C 2 as the slope. Hereafter, this method is denoted as CL. Vandervaere et al. (2000a) proposed a different approach where the linear fitting technique consists of differentiating the cumulative infiltration data with respect to the square root of time (DL method): di C1 2C2 t d t = + (10) and in this case, C 1 is determined as the intercept, and C 2 is equal to half of the slope. If the experimental infiltration data are not linear, Eq. (1) is considered inappropriate and the values of C 1 and C 2 would have no physical meaning. Vandervaere et al. (2000a) indicated that the proposed DL technique is the most appropriate since it allows a visual check of the validity and range of applicability of the two-term Eq. (1). Especially, DL technique revealed the influence of sand contact layer between the disc infiltrometer and soil on first stage of infiltration. Despite the criticism on Zhang (1997) method, this method is often used to determine Κ h0 from experimental infiltration data by tension disc infiltrometer (Angulo-Jaramillo et al., 2000; Vadervaere et al., 2000a). Dohnal et al. (2010) found that Zhang (1997) method gave the best results compared to White and Sully (1987) and Haverkamp et al. (1994), when the n parameter value of the van Genuchten (1980) equation was greater than 1.35. In the case of soils with n values 1<n<1.35, e.g., for fine texture soils, they suggested a modified equation to calculate the Α 2 parameter: A 2 = 11.65 ( n0.82 1)exp 34.65( n 1.19)ah 0 αh 0 ( ) 0.6, 1<n < 1.35 (11) The first aim of this study was to compare the values of C 1 and C 2 parameters received by direct nonlinear fitting of Eq. (1) on experimental infiltration data obtained by a tension disc infiltrometer with those received by two methods of linearization of Eq. (1), for two disturbed soils. The second aim was to compare the Κ h0 values calculated by Zhang (1997) method: i) using the value of A 2 parameter, taking into account the values of α and n proposed by Carsel and Parrish (1988); ii) calculating A 2 parameter (Eqs. 7 or 8) using α and n parameters from experimental water retention data; iii) calculating A 2 parameter using Eq. (11), if 1<n<1.35. 2. MATERIALS AND METHODS Laboratory experiments to determine the water retention curve of two disturbed soil samples, a

100 G. Kargas et al. Loam (L) and a Silty Clay Loam (SiCL), were conducted using a modified Haines (1930) apparatus and a pressure cell, respectively. The van Genuchten (1980) parameters, α and n, were determined by fitting on experimental water retention data, using RETC code (van Genuchten et al., 1991). The soil texture and the bulk density, ρ φ, of soils used are presented in Table 1. Table 1. Soil texture and dry bulk density, ρ φ, of a Loam (L) and a Silty Clay Loam (SiCL) soil Soil type Clay Silt Sand (%) (%) (%) ρ φ (g.cm -3 ) L 20.0 38 42.0 1.12 SiCL 36.5 52 11.5 1.22 The saturated hydraulic conductivity, Κ s, of soil samples was measured using a steady head permeameter for the L soil and a variable head permeameter for the SiCL soil (Κlute and Dirksen, 1986). The K s value is the mean value of five repetitions. A mini disc infiltrometer (Decagon Devices, Inc., 2007) with a radius of 2.25 cm was used to determine the relationship between the cummulative infiltration and root square of time by applying negative pressure heads on soil surface. The disturbed soil samples used had been air dried before the beginning of the experiments, and consequently, the initial soil water content was very low (0.010 cm 3 cm -3 for L and 0.031 cm 3 cm -3 for SiCL). Soil samples were placed in a transparent acrylic tube, 20 cm high and 17 cm in internal diameter, after proper packing to assume homogeneous soil profile. Since the soil samples were disturbed, there was no need to place a layer of sand, to ensure hydraulic contact between the infiltrometer and the soil, avoiding thus the sand impeding effect on infiltration flux. The tension disc infiltrometer was placed at the center of soil samples surface and the pressure heads applied were -7, -4 and -1 cm for the L soil, and -3 and -0.5 cm for a SiCL soil. In order to calculate C 1 and C 2, Eq. (1) was fitted on experimental infiltration data (direct nonlinear fitting). Furthermore, both methods of linearization CL and DL were applied. In the case of A 2 parameter calculation, Eq. (7) or (8) was used depending on the value of the van Genuchten parameter n for each soil sample. For 1<n<1.35, Eq. (11) was used and the results were compared with those obtained by Zhang (1997) using Eq. (8). Furthermore, A 2 parameter was calculated taking into account the values of α and n that are proposed by Carsel and Parrish (1988) (Table 2 in Operator s Manual of Mini Disc Infiltrometer, Decagon Devices, Inc., 2007). 3. RESULTS AND DISCUSSION 3.1 Loam Soil In Figure 1, the experimental cumulative infiltration data against the square root of time are plotted for pressure heads, h 0, -7, -4 and -1 cm for the L soil studied. As shown, the direct nonlinear fitting of Eq. (1) on the experimental data provides excellent fits with a coefficient of determination R 2 0.9998 for all pressure heads. From the fitting procedure, the values of C 2(h0) parameter were C 2(-7) =0.0026, C 2(-4) =0.0032 and C 2(-1) =0.0037 cm s -1. Taking into account α and n proposed by Carsel and Parrish (1988) (a=0.036 and n=1.56 for L soil), Zhang method was applied using Eq. (8) to calculate Α 2(h0) values which were Α 2(-7) =9.91, A 2(-4) =7.53 and A 2(-1) =5.72. Then, the calculated values of K h0 using Eq. (6) were Κ (-7) = 0.0155, K (-4) =0.025 and Κ (-1) =0.038 cm min -1 (Table 2). As shown in Figure 2, the values of C 2(h0) using the CL method were C 2(-7) =0.0026, C 2(-4) =0.0034 and C 2(-1) =0.0038 cm s -1 (Figure 2a) and the corresponding ones using the DL method were C 2(- 7)=0.00255, C 2(-4) =0.00325 and C 2(-1) =0.00360 cm s -1 (Figure 2b). The comparison of the results showed that the C 2(h0) values obtained by the three abovementioned methods were almost the same, and in the case of DL method the coefficient of determination R 2 was the lowest (Figure 2b).

Water Utility Journal 16 (2017) 101 Figure 1. Presentation of experimental cumulative infiltration data versus the square root of time and fitted infiltration equation (Eq. 1) for pressure heads -7 cm, -4 cm and -1 cm for a Loam soil (L) and -3 cm and -0.5 cm for a Silty Clay Loam soil (SiCL) Figure 2. Linear presentation of experimental cumulative data and fitted linear line for the Loam soil according to: a) cumulative linearization method (CL) and b) differentiated linearization method (DL) (I: cm and t: sec) In order to apply the Zhang (1997) method, taking into account the experimental θ(h) data, a comparative presentation between the experimental water retention curve and the fitted by the van Genuchten (1980) equation, for the L soil, is presented in Figure 3. The van Genuchten parameters for the L soil were θ r =0.0003 cm 3 cm -3, α=0.0407, n=1.167 and m=1-1/n=0.1432. Since n<1.9, Eq. (8) was used to calculate Α 2(h0) parameter and the values Α 2(-7) =7.61, Α 2(-4) =3.91 and Α 2(-1) =2 resulted. Then, the corresponding Κ (h0) values, using Eq. (6) and C 2(h0) estimated by DL method, were Κ (-7) =0.020, K (-4) =0.049 and Κ (-1) =0.108 cm min -1 (Table 2). Figure 3. Experimental (points) and fitted (solid line) by the van Genuchten equation water retention curve for the Loam (L) and Silty Clay Loam (SiCL) soils Furthermore, taking into account that 1<n=1.167<1.35, Eq. (11) proposed by Dohnal et al. (2010), instead of Eq. (8), can be used to calculate Α 2(h0) using as α and n values those resulting from the experimental data (Α 2(-7) =8.28, Α 2(-4) =7.51 and Α 2(-1) =6.81), and then the corresponding Κ (h0)

102 G. Kargas et al. values, using Eq. (6) and C 2(h0) estimated by DL method, were Κ (-7) =0.0184, Κ (-4) =0.0259 and Κ (- 1)=0.0317 cm min -1 (Table 2). Overall, as shown in Table 2, the various methodologies used lead to different results. Zhang (1997) and Dohnal et al. (2010) methods lead to similar results, while Zhang (1997) method using the experimental θ(h) data lead to the highest K h0 calculated values. It is worth to note that the K s measured using a steady head permeameter (one-dimensional vertical flux) was 0.022 cm min -1. Table 2. Calculated values of near-saturated hydraulic conductivity (K h0 ) with various methods for Loam (L) soil Zhang (1997)- Dohnal et al. (2010)- Zhang (1997) h 0 (cm) experimental θ(h) experimental θ(h) K h0 (cm/min) -1 0.0380 0.1080 0.0317-4 0.0250 0.0495 0.0259-7 0.0155 0.0200 0.0184 3.2 Silty Clay Loam soil Figure 1, also presents the experimental cumulative infiltration data plotted against the square root of time, and the direct nonlinear fitting of Eq. (1) on the experimental data for pressure heads, h 0, -3, and -0.5 cm for the SiCL soil. As shown, the direct nonlinear fitting of Eq. (1) provides an excellent fit with a coefficient of determination R 2 0.9997 for all pressure heads. From the fitting procedure, the values of C 2(h0) parameter were C 2(-3) =0.0008, and C 2(-0.5) =0.0007 cm s -1. Zhang (1997) method was applied, taking into account α and n proposed by Carsel and Parrish (1988) (a=0.010 and n=1.23 for SiCL soil), and using Eq. (8), the Α 2(h0) values were Α 2(-3) =8.95 and A 2(- 0.5)=7.89. Then, the calculated values of K h0 using Eq. (6) were Κ (-3) = 0.0053 and Κ (-0.5) =0.0053 cm min -1 (Table 3), which are the same. Figure 4. Linear presentation of experimental cumulative data and fitted linear line for the Silty Clay Loam soil (SiCL) according to: a) cumulative linearization method (CL) and b) differentiated linearization method (DL) (I: cm and t: sec) If all experimental cumulative infiltration data are taken into account, then using the CL method, the C 2(h0) values were C 2(-3) =0.0008 and C 2(-0.5) =0.0006 cm s -1. When using a and n values from Carsel and Parrish (1988) and Α 2(h0) from Eq. (8), K (-0.5) was lower than K (-3). When the first data points were removed (Figure 4a, h 0 =-0.5), the R 2 value was increased and the C 2(h0) values become nearly the same in the case presented in Figure 1 for the SiCL soil (C 2(-3) =0.0008, C 2(-0.5) =0.0007). The linear fitting using the DL method (Figure 4b) highlights errors which probably are not detected in direct non-linear fitting (Figure 1). The calculated values of C 2(h0) were C 2(-3) =0.00085 and C 2(-0.5) =0.0009 cm s -1 and the coefficient of determination was R 2 =0.919. The corresponding K (h0) values were Κ (-3) =0.0056 and Κ (-0.5) =0.0068 cm min -1 taking into account A 2(h0) using α and n from Carsel and Parrish (1988). Figure 3, also, presents the experimental water retention curve and the fitted by the van Genuchten (1980) equation for the SiCL soil. The van Genuchten parameters were θ r =0.0 cm 3 cm -3,

Water Utility Journal 16 (2017) 103 α=0.0137, n=1.151 and m=1-1/n=0.131. Since n<1.9, Eq. (8) was used and Α 2(h0) parameter values were Α 2(-3) =4.92 and Α 2(-0.5) =4.06. Then, the corresponding Κ (h0) values using Eq. (6) and C 2(h0) estimated by DL method were Κ (-3) =0.0103 and Κ (-0.5) =0.0133 cm min -1 (Table 3). Furthermore, taking into account that 1<n=1.151<1.35, Eq. (11) (Dohnal et al., 2010) can be used to calculate Α 2(h0), instead of Eq. (8), using as α and n values those resulting from the experimental data. Using Α 2(-3) =12.14 and Α 2(-0.5) =11.59 and the corresponding C 2(h0) calculated by the DL method, the Κ (h0) values using Eq. (6) were Κ (-3) =0.0042 and Κ (-0.5) =0.0046 cm/min (Table 3). Table 3. Calculated values of near-saturated hydraulic conductivity (K h0 ) of a Silty Clay loam (SiCL) soil using various methods Zhang (1997)- Dohnal et al. (2010)- Zhang (1997) h 0 (cm) experimental θ(h) experimental θ(h) K h0 (cm/min) -0.5 0.0053 0.0133 0.0046-3 0.0053 0.0103 0.0042 As shown in Table 3, the various methodologies used lead to different results except of Zhang (1997) and Dohnal et al. (2010) methods which lead to similar results like in case of the L soil studied. Also, Zhang (1997) method using the experimental θ(h) data leads to the highest K h0 calculated values, while the K s measured using a variable head permeameter was 0.0032 cm min -1. The analysis of the results showed that the application of DL technique on experimental cumulative infiltration data to calculate C 1 and C 2 parameters led to the lowest values of the coefficient of determination R 2 compared to the other techniques used for both soils studied. However, DL enables a visual check of undesirable experimental points which should be removed, so that C 2(h0) and consequently K (h0) values have physical meaning. Despite DL has been mainly proposed to reveal undesirable experimental points from the influence of sand contact layer at the first stage of infiltration process, it seems to be a useful technique to lab infiltration experiments on disturbed soils where the sand contact layer is not required. Furthermore, to assess the validity of the Eq. (1), the C 1 parameter should be increased by increasing the negative pressure head. Experimental infiltration data showed that this assumption is confirmed in both soils studied (Figure 2a,b and Figure 4a,b). Also, the results showed that Vandervaere et al. (2000b) criterion to check K h0 calculation reliability (Eq. 4) by the method of Haverkamp et al. (1994) is not satisfied in any case for both soils studied. Similar results for the same soil types had been presented by Dohnal et al. (2010). It is noted that in all cases studied, the van Genuchten parameters used were obtained by drying water retention curve. In order to achieve compatibility between the data used and the phenomenon of infiltration, the knowledge of wetting retention curve is required and its influence is needed to be investigated. 4. CONCLUSIONS In the present study, different versions of Zhang (1997) method were examined using cumulative infiltration data, obtained from a tension disc infiltrometer with multi pressure heads on two soils, to determine near-saturated hydraulic conductivity, K h0. For this, the following two-term infiltration equation, I = C1 t + C2t, was used and the values of C 1 and C 2 parameters were determined by various optimization techniques. Results showed that the most effective method to calculate these parameters was the differentiated linearization method. Among different versions of the method for calculating K h0 there seem to be substantial differences, except of the method proposed by Dohnal et al. (2010) and Zhang (1997) as proposed by the user manual of tension disc infiltrometer (Decagon Devices, Inc., 2007). The results of this study concern soil types with n<1.35. Due to

104 G. Kargas et al. large uncertainty of K h0 measurements, further investigation is required on coarse texture soils (n>1.35). ACKNOWLEDGEMENTS An initial shorter version of the paper has been presented in Greek at the 3 rd Common Conference (13 th of the Hellenic Hydrotechnical Association, 9 th of the Hellenic Committee on Water Resources Management and 1 st of the Hellenic Water Association) Integrated Water Resources Management in the New Era, Athens, Greece, December 10-12, 2015. REFERENCES Angulo-Jaramillo, R., Vandervaere, P., Roulier, J., Thony, J., Gaudet, P., Vauclin, M., 2000. Field measurement of soil surface hydraulic properties by disc and ring infiltrometers. A review and recent developments. Soil and Tillage Res.; 55: 1-29. Ankeny, M. D., Ahmed, Μ. Kaspar, T. C., Horton, R., 1991. Simple field method for determining unsaturated hydraulic conductivity. Soil Sci. Soc. Am. J.; 55: 467-470. Carsel, R. F., Parrish, R. C., 1988. Developing joint probability distributions of soil water retention characteristics. Water Resour. Res.; 24: 755-769. Clothier, B. E., White, I., 1981. Measurement of sorptivity and soil water diffusivity in the field. Soil Sci. Soc. Am. J.; 45: 241-245. Decagon Devices Inc., 2007. Mini Disc Infiltrometer, User s Manual. Ver 5, 24 p. Dohnal, M., Dusek, J., Vogel, T., 2010. Improving hydraulic conductivity estimates from mini disc infiltrometer measurements for soils with wide pore size distributions. Soil Sci. Soc. Am. J.; 74: 804-811. Gardner, W. R., 1958. Some steady-state solutions of the unsaturated moisture flow equation with application to evaporation from a water table. Soil Sci.; 85: 228-232. Haines, W. B., 1930. Studies in the physical properties of soils. V. The hysteresis effect in capillary properties and the modes of moisture distribution associated therewith. J. Agric. Sci.; 20: 97-116. Haverkamp, R., Ross, P. J., Smettem, K. R. J., Parlange, J.-Y., 1994. Three dimensional analysis of infiltration from disc infiltrometer 2. Physically-based infiltration equation. Water Resour. Res.; 30: 2931-2935. Klute, A., Dirksen, C., 1986. Methods of soil analysis: Part 1, Rev. Physical and Mineralogical Methods. ASA, Monogr. 9: 694-700. Latorre, B., Moret-Fernández, D., Peña, C., 2013. Estimate of soil hydraulic properties from disc infiltrometer three-dimensional infiltration curve: theoretical analysis and field applicability. Procedia Environ. Sci.; 19: 580-589. Lazarovitch, N., Ben Gal, A., Simunek, J., Shani, U., 2007. Uniqueness of soil parameters determined by a combined Wooding inverse approach. Soil Sci. Soc. Am. J.; 71: 860-865. Marquart, D. W., 1963. An algorithm for least squares estimation of nonlinear parameters. SIAM J. Appl. Math.; 11: 431-441. Philip, J. R., 1957. The theory of infiltration: 4. Sorptivity and algebraic infiltration equations. Soil Sci.; 84: 257-264. Reynolds, W. D., Elrick, E. D., 1991. Determination of hydraulic conductivity using a tension infiltrometer. Soil Sci. Soc. Am. J.; 55: 633-639. Smettem, K. R. J., Clothier, B. E., 1989. Measuring unsaturated sorptivity and hydraulic conductivity using multiple disc permeameters. J. Soil Sci.; 40: 563-568. Smettem, K. R. J., Parlange, J.-Y., Ross, P. J., Haverkamp, R., 1994. Three-dimensional analysis of infiltration from the disc infiltrometer: 1. A capillary-based theory. Water Resour. Res.; 30: 2925-2929. Smiles, D. E., Knight, J. H., 1976. A note on the use of the Philip infiltration equation. Aust. J. Soil Res.; 14: 103-108. van Genuchten, M. Th., 1980. A closed-form equation for predicting the hydraulic conductivity of unsaturated soils. Soil Sci. Soc. Am. J.; 44: 892-898. van Genuchten, M. T, Leij, F. J., Yates, S. R., 1991. The RETC code for quantifying the hydraulic functions of unsaturated soils. U.S.D.A., Riverside, California. Vandervaere, J. P., Vauclin, M., Elrick, D. E., 2000a. Transient flow from tension infiltrometers: I. The two parameter equation. Soil Sci. Soc. Am. J.; 64: 1263-1272. Vandervaere, J. P., Vauclin, M., Elrick, D. E., 2000b. Transient flow from tension infiltrometers: II. Four Methods to Determine Sorptivity and Conductivity. Soil Sci. Soc. Am. J.; 64: 1272-1284. Vandervaere, J. P., 2002. Methods of soil analysis: Part 4, Physical Methods. SSSA, Inc. Madison, Wisconsin, USA, pp. 889-894. Warrick, A. W., 1992. Models for disc infiltrometers. Water Resour. Res.; 28: 1319-1327. White, I., Sully, M. J., 1987. Macroscopic and microscopic capillary length and time scales from field infiltration. Water Resour. Res.; 23: 1514-1522. Wooding, R. A., 1968. Steady infiltration from shallow circular pond. Water Resour. Res.; 4: 1259-1273. Zhang, R., 1997. Infiltration models for the disc infiltrometer. Soil Sci. Soc. Am. J.; 61: 1597-1603.