PV-Wind Hybrid System with Fuel Cell & Electrolyzer

Similar documents
PV-Wind System with Fuel Cell & Electrolyzer

Fuzzy Logic Controller Based Maximum Power Point Tracking for PV panel using Boost Converter

Design and Modeling of Wind Energy Conversion System Based on PMSG Using MPPT Technique

A CUK-SEPIC FUSED CONVERTER TOPOLOGY FOR WIND-SOLAR HYBRID SYSTEMS FOR STAND-ALONE SYSTEMS

Modeling of Incremental Inductance Based PV System with Power Grid

Dynamic modeling and control of a wind turbine generator with fuel cell, Ultra capacitor stack as an auxiliary storage

Simulation Model of a Hybrid Photo Voltaic/ Fuel Cell/ Ultra-Capacitor System for Stand Alone Applications

Fault Management in Renewable Energy Resources

Maximum Energy Extraction in Wind Solar Hybrid Energy Conversion System

Modeling and Control of MPPT Based Grid Connected Wind-PV Hybrid Generation System

MATLAB/Simulink Modeling and Experimental Results of a PEM Electrolyzer Powered by a Solar Panel

KEYWORDS: Renewable energy system, Hybrid,Rural electrification, PV, Wind

Modeling and Simulation of Solar and Wind Hybrid Power System Using Matlab

Garg Vishakha, International Journal of Advance Research, Ideas and Innovations in Technology.

Design and control of renewable power system through wsn in mirogrid

Modeling of Fuel Cell Connected Distribution Generation System

Simulation of a small wind fuel cell hybrid energy system

Modeling and Simulation of Microgrid Connected Renewable Energy Resources with MPPT Controller and by Using SVPWM Technique

Webpage: Volume 6, Issue VI, July 2018 eissn

Integrated Solar PV and Thermoelectric Energy System

MODELING AND SIMULATION STUDY OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND TURBINE SYSTEM IN MICRO-GRID APPLICATION

ID rd International Congress on Energy Efficiency and Energy Related Materials. Fuel Cell for Standalone Application Using FPGA Based Controller

Performance Analysis of grid connected PV Wind Hybrid Power System

Modeling a PV-FC-Hydrogen Hybrid Power Generation System

SIMULATION OF GRID CONNECTED PMG WIND ENERGY AND SOLAR ENERGY SYSTEMS USING MPPT TECHNIQUES

ISSN Vol.09,Issue.04, March-2017, Pages:

ANALYSIS OF THE BEHAVIOR FOR REACTIVE POWER COMPENSATION USING SVC CONTROLLED HYBRID SOLAR/WIND POWER GENERATING SYSTEMS

Question # 1: Write true or false with correcting the wrong statement

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

A HYBRID DIESEL-WIND-PV-BASED ENERGY GENERATION SYSTEM WITH BRUSHLESS GENERATORS

CHAPTER 5 CONCLUSION AND FUTURE SCOPE

The Master of IEEE Projects. LeMenizInfotech. 36, 100 Feet Road, Natesan Nagar, Near Indira Gandhi Statue, Pondicherry

Simulation Of High Performance Utility By Improving Power Factor In PV Grid System

Design of Enhanced MPPT Techniques for Solar and Wind Energy Conversion Systems in a Microgrid

Simulation of a stand-alone power system using renewable energy sources and hydrogen storage

Micro-generation using LMS Imagine.Lab AMESim

Steady-State and Dynamic Study of Photovoltaic (PV) System in University of New Haven: Towards to a Green and Secure Campus

A New Control of Single-Stage Grid Connected Photovoltaic System

ISSN Vol.07,Issue.16, November-2015, Pages:

Grid Tied RES Source Control Technique to mitigate harmonic and Reactive Power Compensation by using UPQC.

Wind-Solar-Hydel Cogeneration Systems in Remote Areas

Dynamic Modeling and control of a Wind-Fuel Cell through Hybrid Energy System

Simulation of Solar and Wind Power Plant Using MATLAB for Micro-Grid

Modelling of a PMSG Wind Turbine with Voltage Control

Design of Hybrid Power Generation Using Solarpv Module and Wind Turbine

DISTRIBUTED GENERATION AND POWER QUALITY

Hybrid Wind-Diesel Generation System

Transient Stability Analysis of Renewable Energy System with Grid Interfacing at PCC

Renewable Energy Based Hybrid Technology for Power Generation System: Pollution Free from GHG Swati Maurya 1*, Aishvarya Narain 2, Rajan Kumar 2 1

A Review on Multiport DC-DC Converter for Different Renewable Energy Sources

H AND REPETITIVE CONTROL

Australian Journal of Basic and Applied Sciences. Hybrid Control Method for Maximum Power Point Tracking (MPPT) of Solar PV Power Generating System

AN OVERVIEW OF SINGLE SWITCH DC/DC CONVERTER TOPOLOGY FOR SOLAR PHOTO-VOLTAIC APPLICATIONS

PHOTOVOLTAICS HISTORY OF PHOTOVOLTAICS

Modeling of a Vertical Axis Wind Turbine with Permanent Magnet Synchronous Generator for Nigeria

Technical Feasibility of Photovoltaic Fuel Cell: A Model of Green Home Power Supply for Rural India

Microgrid Energy Management System Using Fuzzy Logic Control

Advances on Distributed Generation Technology

Modeling and Simulation of a Microgrid with Multiple Energy Resources.

Integrated Distributed Generation (PV+WIND) Using Hysteresis Controller

M.E POWER ELECTRONICS AND DRIVES Course Outcome R2009 ( BATCH)

SUPERVISORY PREDICTIVE CONTROL OF STANDALONE WIND/SOLAR ENERGY GENERATION SYSTEMS

Reference: Photovoltaic Systems, p. 229

Hybrid PV-FC Power System JOSÉ CARLOS QUADRADO ISEL, R. Cons. Emídio Navarro, LISBOA CAUTL, Av Rovisco Pais, LISBOA PORTUGAL

FUEL CELLS ALEJANDRO AVENDAO

Modeling And Control Of Hybrid Wind-Solar Energy System

Custom Power Interfaces for Renewable Energy Sources

Index term: wind-solar energy hybrid power generation, optimization control, decision-making model. Plant load factors (PLF)

Modelling and Simulation of an Integrated Photovoltaic-Wind Hybrid Power Generation Strategy

Study on Suppression of Frequency Fluctuation in Microgrid by Renewable Energy and Integrated Coal Gasification Combined Cycle

PhD Dissertation Defense Presentation

As Conventional sources of energy are rapidly depleting and

A Study on Optimal Design Feasibility of Microgrid Power System for Rural Electrification: Amhara Region in Ethiopia

Design and Simulation of Photovoltaic System in Matlab using Simulink

Power control of a photovoltaic system connected to a distribution frid in Vietnam

Impacts of the Decentralized Wind Energy Resources on the Grid

ENERGY HARVESTING. Energy Conversion Systems. Solar, Wind, and Ocean. Omer C. Onar. Alireza Khaligti

Simulation Analyis of Maximum Power Control of Photo Voltaic Power System

Grid-Connected Photovoltaic System without using Boost Converter

Optimum Fuel Cell Utilization with Multilevel DC-DC Converters

Study on the Technology of MPPT of the Solar Photovoltaic Based on the Model Predictive Control

Research Article Volume 6 Issue No. 4

IN-GRID SOLAR-TO-ELECTRICAL ENERGY CONVERSION SYSTEM MODELING AND TESTING

DESIGN AND SIMULATION OF GRID-CONNECTED PV SYSTEMS WITH GENERATION OF CONSTANT POWER USING FUZZY LOGIC CONTROLLER

Solar PV, Wind, and Storage System Design. Ilya Chernyakhovskiy, NREL April 26, 2018 Dushanbe, Tajikistan

Design and Implementation of Grid Connected Hybrid PV and Wind Energy Generation System

Contents / 1, Power Electronics for Renewable Energy Sources 1. Contributors ' j xi Preface I xiii

SYNOPSIS OF THE THESIS. Enhanced Power Quality Management of Grid Connected Wind Farm

( 1 ) Ramptime Current -Controlled APF for Harmonic Mitigation, Power Factor Correction and Load Balancing

Introduction. ECEN 2060 Lecture 1 Fall 2010

Economical & Renewable Techniques for Power Generation, Energy Storage and Voltage Sag Mitigation

Modeling and Simulation of Utility Interfaced PV/Hydro Hybrid Electric Power System P. V. V. Rama Rao, B. Kali Prasanna, Y. T. R.

DESIGN AND ANALYSIS OF A HYBRID WIND-PHOTOVOLTAIC SYSTEM

Wind Farms in Weak Grids Compensated with STATCOM

B.TECH POWER SYSTEMS IEEE TITLES

Comparison of Variable Speed Wind Turbine Control Strategies

High-Performance Constant Power Generation in Grid-Connected PV Systems

NON-CONVENTIONAL SOURCE OF ENERGY FOR SUSTAINABLE GROWTH OF RURAL AND URBAN AREAS

Your partner for sustainable hydrogen generation siemens.com/silyzer

A REVIEW ON POWER CONTROL SYSTEM INVERTERS WITH VARIATION POWER SYSTEM

Transcription:

Ministry of New & Renewable Energy From the SelectedWorks of Radhey Shyam Meena Winter December, 2015 PV-Wind Hybrid System with Fuel Cell & Electrolyzer Engineer Radhey Shyam, Meena Available at: https://works.bepress.com/radhey_meena/20/

PV-Wind Hybrid System with Fuel Cell & Electrolyzer 1 Deepa Sharma, 2 Radhey Shyam Meena, 3 Dr. D.K.Birla Dept. Of Electrical Engineering S Member- The Institution of Engineering and Technology (IET) [1] Sri Balaji College of Engineering & Technology Jaipur(Rajasthan) [1] University College Of Engineering Kota [2],[3] Rajasthan Technical University Kota-324010 (India) [1],[2],[3] Radheys.2011@gmail.com, rsmeena_ee@theiet.org, deepa.sharma934@gmail.com Abstract: With ever-increasing concerns on energy issues, the development of renewable energy sources is becoming more and more attractive In this paper, a detailed modeling and simulation of solar cell/ wind turbine/ fuel cell hybrid power system is developed using a novel topology to complement each other and to alleviate the effects of environmental variations. This paper reviews both the wind power and photovoltaic (PV) power generation techniques and their maximum-power-point tracking (MPPT) methods. Then, a new stand-alone wind PV hybrid generation system is proposed for application to remote and isolated areas. The experimental results confirm that the proposed hybrid generation system can provide high efficiency with the use of MPPT. Modeling and simulations are conducted using MATLAB/Simulink software packages to verify the effectiveness of the proposed system. The experimental results confirm that the proposed generation system can provide high efficiency with the use of MPPT. The results show that the proposed hybrid power system can tolerate the rapid change in natural conditions and suppress the effects of these fluctuations on the voltage within the acceptable range.the proposed system can be used for off grid power generation in non interconnected areas or remote isolated communities of nation. Key Words- Solar PV System, Wind Energy System, Hybrid Solar-Wind System, Off Grid Generation, Maximum Power Point Tracking (MPPT) I. Introduction With their advantages of being abundant in nature and nearly non pollutant, renewable energy sources have attracted wide attention.wind power is one of the most promising clean energy sources since it can easily be captured by wind generators with high power capacity. Photovoltaic (PV) power is another promising clean energy source since it is global and can be harnessed without using rotational generators. In fact, wind power and PV power are complementary to some extent since strong winds are mostly to occur during the nighttime and cloudy days whereas sunny days are often calm with weak winds. Hence, a wind PV hybrid generation system can offer higher reliability to maintain continuous power output than any other individual power generation systems. In those remote or isolated areas, the stand-alone wind PV hybrid generation system is particularly valuable and attractive. The main objective of this paper is to come out with an experimental model of off grid PV-Wind energy system and analysis its hybrid operation. As green house effects and environmental issues becomes more of a concern, renewable energy is one of the options in reducing pollution. Furthermore, natural resources used in the production of power are dwindling and becoming more expensive. There are a few types of renewable energies; photovoltaic (PV) system and wind energy system. PV modules used to be expensive, but in recent years, their price has been slowly dropping, and the payback period also reduces, as they become increasingly economical, they will be used in more applications. PV modules output efficiency has also increased in recent years about 24 to 30%, and with these growths in photovoltaic technology, there is no doubt that PV will have a good stand in the near future. The majority of electricity is generated by burning coal, rather than more eco-friendly methods like hydroelectric power. This use of coal cause untold environmental damage through CO2 and other toxic emissions. The energy sector is by far the biggest source of these emissions, both in India and globally, and if we are to tackle climate change it is clear we need to move away from burning limited fossil fuel reserves to more sustainable and renewable source of energy. The proposed system can be used for off grid power generation in non interconnected areas or remote isolated communities of nation. For the stand-alone off grid system, the hybrid generation system can easily be set up in remote and isolated areas where a connection to the utility network is either impossible or unduly expensive. Over the years, there have been only a few research works on the standalone wind PV hybrid generation system in which the wind generators are focused on induction machines. The purpose of this paper is to present a new stand-alone wind PV hybrid generation system for remote or isolated areas. The keys are to perform flux control of the wind generator so as to extract the maximum power from the wind turbine and to perform duty cycle control of the single-ended primary inductance converter so as to harness the maximum power from the PV panels. Hence, this hybrid generation system forms a highly independent generation system from day to night. II. System Configuration Fig.shows the configuration of the proposed wind PV hybrid generation system. This hybrid generation system is constituted by a wind power generation branch and a PV power generation branch. The wind power generation branch is composed of a doubly excited PM brushless machine, a three-phase rectifier, a shared battery tank, and a shared inverter. On the other hand, the PV power generation branch is composed of an array of 3 3 PV doi : 10.17950/ijer/v4s12/1209 Page 673

panels, a SEPIC, a dc/dc converter, a shared battery tank, and a shared inverter. While the SEPIC performs the MPPT for the PV panels, the dc/dc converter functions to step up the SEPIC output voltage so that the same battery tank is shared by both the wind power and PV power branches. The inverter is used to convert the dc voltage to the ac voltage so that a typical household can freely utilize electricity from the ac Fig.1. Proposed wind PV hybrid generation system If there are multiple generation systems connecting to the grid, synchronization among inverters needs to be taken. Since the additional inverter will inevitably cause efficiency loss, the concept of dc microgrid is under active research. The proposed wind PV hybrid generation system possesses the following features. 1) Similar to other wind PV hybrid generation systems, the proposed system utilizes the battery tank and inverter to couple the wind power and PV power branches. Additionally, the PV power can directly be used for dc field excitation of the doubly excited PMgenerator, rather than conducting dc/ac conversion that involves inevitable power loss. Thus, this feature is particularly advantageous for a small-size stand-alone wind PV system in which the PV panels are mounted onto the pole of the wind generator and the resulting PV power is relatively limited. 2) The wind power generation branch and the PV power generation branch of the hybrid generation system can independently be controlled, hence achieving the MPPT simultaneously. 3) Compared with an individual generation system (the wind power or the PV power), the wind PV hybrid generation system cannot only harness more energy from nature but also allow the wind power and the PV power to complement one another to some extent between day and night. 4) For the wind power generation branch, the doubly excited PM brushless generator, as shown in Fig., adopts the outer rotor topology, which enables the rotor to directly couple with the wind blades. Hence, it can eliminate the complicated mechanical transmission and the relevant costs. Also, since the proposed generator adopts two excitations (PMs and dc field windings), it can flexibly regulates its magnetic field distribution and consequently control the output voltage and power. Thus, without using an additional power converter, which usually exists for the conventional MPPT, the generator itself can adjust the output power at a given wind speed and realize the MPPT. 5) For the PV power generation branch, solar energy is directly converted to electricity by the PV panels and then controlled by a SEPIC for the MPPT. This PV power generation branch processes the merits of simple structure and uncomplicated control. As compared with the latest wind PV hybrid generation systems, the proposed system offers some distinct energy-efficient merits. First, the system in previous paper was simply based on parallel operation of a wind-driven induction generator and a battery-coupled PV array via a three-phase inverter. This system cannot perform any efficiency optimization for the wind generator or the PV array. Also, because of inevitable rotor copper loss, the induction generator inherently suffers from relatively lower efficiency than the PMbrushless generator. Second, the system in paper was based on parallel operation of a wind-driven PM synchronous generator and PV panels with a battery bank as energy storage. It utilizes a dc/dc converter to perform the MPPT for the PV panels, while it attempts to use a three-phase rectifier and another dc/dc converter to maximize the wind power generation. It is anticipated that this system can offer higher efficiency than the previous one since it utilizes the MPPT to harness PV power and a PM brushless generator to capture wind power. However, the use of a dc/dc converter to maximize the wind power generation is too idealized or impractical, which may even impair the originally captured wind power. The whole system of paper was assessed by computer simulation only. Third, the system in one paper was based on parallel operation of a wind-driven induction generator and a PV array with a battery bank as energy storage. It employs a threephase space-vector PWM ac/dc converter to regulate the d- and q-axis current in such a way that the captured wind power can be maximized, while it utilizes a dc/dc converter to perform the MPPT for the PV array. This system is more practical than that in one paper and should offer higher efficiency than, but it still suffers from relatively low efficiency of the induction generator and relatively complex control due to d q-coordinate transformation. The configuration of the proposed system is similar to that in previous but with a special doubly excited PM brushless generator. Hence, it can inherit the high efficiency of PM brushless generators, while it can employ simple dc current control to perform efficiency optimization over a wide range of wind speeds. Therefore, the proposed system can offer higher efficiency than other wind PV hybrid generation systems. 7) In terms of costs, the proposed hybrid system definitely takes an advantage of lower cost than two individual wind and PV power systems since it can share the same battery tank for energy storage, the same inverter for dc/ac conversion, and the same digital hardware for the MPPT. As compared with other wind PV doi : 10.17950/ijer/v4s12/1209 Page 674

hybrid generation systems in last one paper, the proposed system will be relatively less costly than, which is due to the fact that the induction generator is cheaper than the proposed doubly excited PM brushless generator, while the conventional PM synchronous generator desires more PM materials and, hence, more expensive than the proposed one. Nevertheless, taking into account the reduction of operating cost due to efficiency optimization., II. Proposed Problem For wind-pv hybrid power generation, it has two branches namely, the wind power generation and PV power generation. Since the wind power and PV power can compensate each other to some extent during the day and night, the development of wind-pv hybrid power generation is attractive. As PV becomes more affordable, its demand will increase. With this increase, the future for grid tied PV systems or off grid systems will be better. PV systems can replace batteries, as its technology becomes more advance and standard for safety is increased. Grid tied PV systems are increasing in number over years. The technology is used to provide either uninterrupted Power Supply, feeding/selling the excess power to the grid or as a stand-alone. (a) PV system. (Solar cell) A solar cell module is the basic element of each photovoltaic system. It consists of many jointly connected solar cells. A number of solar cell models have been developed, but the one diode electrical equivalent circuit is commonly used for cell based or module based analysis. It consists of a diode, a current source, a series resistance and a parallel resistance. The current source generates the photo-current that is a function of the incident solar cell radiation and temperature. The diode represents the p-n junction of a solar cell. The temperature dependence of the diode saturation current and constant diode ideality factor are included in the modeling. At real solar cells, a voltage loss on the way to the external contacts is observed. This voltage loss is expressed by a series resistance (Rs). Furthermore leakage currents are described by a parallel resistance (Rsh). However, the series resistance is very small and the parallel resistance is very large [6]. So we can ignore Rs and Rsh. The solar cell current equation is- Vmp I pv I sc[1 C1{exp( ) 1}] C V Ett ( )[ { Ta 0.002Ett 1}] I Est solar cell voltage equation is- Ett Vpv Vmp[1 0.0539 log( )] E [ T Here constant is given by- 2 a oc 0.02E tt st ] mp We used the solar cell current and voltage equation to build a solar cell model by MATLAB/Simulink. Fig. 2 Solar PV System Outputs without mmpt (i), (ii) and (iii) Fig. 3 Solar cell main final outputs of current and voltage for off grid system in (i),(ii),(iii) and (iv) doi : 10.17950/ijer/v4s12/1209 Page 675

Modeling of Photovoltaic system Although there is much interest in PV system, there are still not much off grid-connected PV systems in the world today. In this paper, we are going to look at the components that make up a off - grid-connected PV system are discussed. In years to come, when PV modules become cheaper, and have a place in the power market, it could serve as means of energy storage for residents and commercial buildings. Energy storage in this sense, without utilizing batteries, is an improvement; however problems are inherent in these systems too. There is little information on the real extent of these systems as there are not much demonstration models on the system in the world today. (b) Wind System The power output of wind turbine is relating to wind speed with a cubic ratio. Both the first order moment of inertia (J) and a friction based dynamic model for the wind turbine rotor, and a first order model for the permanent magnet generator are adopted. The dynamics of the wind turbine due to its rotor inertia and generator are added by considering the wind turbine response as a second order slightly under-damped system [4]. Using this simple approach, small wind turbine dynamic is modeled as Pg ( s) 0.25 2 P ( s) s 0.707s 0.25 wt 4(i) Output Curve of Cp and wind speed 4(iv) Output Curve of V dc and wind speed 4(v) Out put power and wind speed Fig. 4 (i),(ii),(iii),(iv) and (v) Out of Wind System (c) Fuel Cell The PEM fuel cell is one of the most promising and certainly the best known of the fuel cell types satisfying above requirements. It is often considered as a potential replacement for the internal combustion engine in transportation applications. The PEM fuel cell consists of porous carbon electrodes bonded to a very thin sulphonated polymer membrane. The thermodynamic potential E is defined via a Nernst equation in expanded form as 3 E 1.229 0.85 10 ( T 298.15) 5 4.3085 10. T.(ln P H 0.5ln P ) 2 O 2 The parametric equation for the over-voltage due to activation and internal resistance developed from the empirical analysis is given as The combined effect of thermodynamics, mass transport, kinetics, and ohmic resistance determines the output voltage of the cell as defined by 4(ii) Output Curve of Rotor speed and wind speed The ohmic voltage loss in the fuel cell is given by 4(iii) Without Zoom out The fuel cell system consists of a stack of 65 similar cells connected in series. Therefore, the total stack voltage is given by doi : 10.17950/ijer/v4s12/1209 Page 676

Using the mole conservation principle, the gas pressure of the fuel cell anode is given as sudden load changes. The ultra-capacitor is modeled as a low pass filter with the transfer function given below The gas pressure of the fuel cell cathode is given as Using (6)-(16), the MATLBA/Simulink model of a fuel cell is built. D. Electrolyzer Water can be decomposed into its elementary components by passing electric current between two electrodes separated by an aqueous electrolyte [7]. The electrochemical reaction of water electrolysis is given by According to Faraday s law, hydrogen production rate of an electrolyzer cell is directly proportional to the electrical current in the equivalent electrolyzer circuit. where ie is the electrolyzer current, nc is the number of electrolyzer cells in series, and η F is the Faraday efficiency. The ratio between the actual and the theoretical maximum amount of hydrogen produced in the electrolyzer is known as Faraday efficiency. Assuming that the working temperature of the electrolyzer is 40, Faraday efficiency is expressed by According to the (18) and (19), a simple electrolyzer model is developed using Simulink. The storage and consumption are also considered in this model. Fig. 5 Output of Electrolyzer efficiency and time E. Ultra-Capacitor Model Ultra-capacitors are used in power applications requiring short duration peak power. An ultra-capacitor is an energy storage device with a construction similar to that of a battery. In this subsection, we present the model of the UC bank to perform load sharing with the FC system when they simultaneously operate with the wind turbine and solar cell. Although FC systems exhibit good power supply capability during steady state operation, the response of fuel cells during instantaneous and short-term peak power demand periods is relatively poor. In these periods, the UC bank can assist the FC system to achieve good performance whereas reducing the cost and size of the FC system. Such an ultra-capacitor module was connected in parallel with the fuel cell to reduce its voltage variation due to Where capacitance C=108.75 μf, series resistance Rc=16 mω and stray resistance Rs=0.01 Ω. III. System Description The system consists of a 75W solar cell, a 400W wind turbine, a 500W proton exchange membrane fuel cell, an ultra-capacitors, an electrolyzer, and a power conditioner. The power conditioner includes a boost circuit and a SPWM inverter. It is used to step up ultra capacitor voltage to DC 200V and invert to 120Vrms, 60Hz AC. The wind turbine adopted is Southwest Wind power Air 403. When wind speed is 12.5m/s, the wind turbine produces the maximum power 400W. Solar cell adopted is SIEMENS SP75 and its maximum power is 75W. Wind turbine and solar cell are the main sources to supply load demand. Fuel cell model includes a fuel cell module and a fuel controller. The fuel controller consists of two PID controllers to limit the flows of hydrogen and oxygen. The fuel cell is a accessory generator in this system and supplies insufficient power. In order to keep the supply and demand is balanced. When the supply is bigger than the load need, the electrolyzer model electrolyzes water to produce hydrogen and store it for further usage. Thus, the system can circulate supply load demand and energy will not be wasted. IV. Results Simulation results with step changes in load demand, wind speed, radiation, and ambient temperature are analyzed and shown in Figs. The initial wind speed is 10 m/s. Wind speed increases, at t=10s, from 10 to 12 m/s and decreases to 8 m/s at t=16s. The solar cell initially supplies power at the radiation 400W/m2 and temperature 25. At 15s, the radiation increases to 600W/m2 and temperature also increases to 28. The load demand changes from 375W to 225W at 10s. These step inputs cause changes in available power and load consumption. The power tracking performance of the hybrid topology with respect to load demand change and environmental variations is shown in Fig. 6(i) Out put solar power with time in hybrid system. 6(ii) Out put solar power and wind power with time. doi : 10.17950/ijer/v4s12/1209 Page 677

6(iii) Output of solar wind and load with time Fig. 7(i),(ii) shows the variation in current with time for solar cell and fuel cell in our model. These changes are reflected in the performance of the fuel cell system. The stack current variation at t=0s to t=10s is due to start-up transients and load demand, as the solar cell s and wind turbine s contributions are limited and fixed. During t=10s to t=16s, the fuel cell current decreases to zero because load demand is reduced and the wind turbine increases output power. After t=16s, variation in fuel cell current is due to changes in power demand from the fuel cell with varying availability of wind energy. Such changes in fuel cell current cause the stack voltage to vary significantly. Generally, a lower level of current implies higher stack voltage and vice versa. The use of an ultra capacitor in parallel with the fuel cell reduces the stack s output variation as shown in Fig. 6(iv) Final Out put of solar wind and load and fuel cell with time Fig. 6 (i), (ii),(iii) and (iv) represent the variation curve for out put power of solar system, wind system, load and fuel cell with time in a hybrid system. Fig. 4 show the Power tracking performance of the hybrid topology with respect to load demand change and environmental variations. Associated parameter variations in solar cell, wind turbine, fuel cell, ultra capacitor, power converter output, and system performance are analyzed. With variation in load, the power demand changes from 375W to 225W at 10s as shown in Fig. The fuel cell provides power for load requirement because of the output powers of the wind turbine and solar cell are not sufficient enough to supply load demand at t=0s to 10s. However, as the wind speed increases, the captured power increases and the contribution of the fuel cell decrease. Any excess power is diverted to the electrolyzer during this period. Similarly, with sudden decrease in wind speed, the contribution of the fuel cell starts at t=19.1s. With changes in load and environmental conditions, the solar cell current and fuel cell current vary as shown in Fig. 8(i) Output voltage of ultra capacitor with time. 8(ii) Output voltage of solar with time. 7(i) Out put current in solar cell model with time. 7(ii) Output current in solar and fuel cell with time 8(iii) Output voltage of fuel cell with time. doi : 10.17950/ijer/v4s12/1209 Page 678

8(iv) Out voltage of solar and wind with time. Fig.8 (i),(ii),(iii),and (iv) represent the voltage variations with time for capacitor, solar, fuel and wind system. With variations of the ultra-capacitor voltage between 49 and 62 V, the power converter unit regulates the load voltage. The controller in the boost converter adjusts the duty ratio so as to attain a fixed 200V DC in the inverter s input. The inverter, on the other hand, delivers a 120 Vrms, 60 Hz AC to the load. The hydrogen is a fuel of fuel cell. The electrolyzer electrolyzes water to produce hydrogen by the excess power of the system and store it from t=10s to t=19.1s. The variation of hydrogen in storage tank is shown in Fig. Fig.9 Hydrogen variation in storage tank. The system can circulate supply load demand and renewable energy will not be wasted. V. Conclusion and Future Scope Conclusion A generalized PV model has been developed in MATLAB/SIMULINK. A portion of the energy requirement for a private house, farm house, a small company, an educational institution or an apartment house depending on the need at the site where used has been supplied with the electricity generated from the wind and solar power. It reduces the dependence on one single source and has increased the reliability. Hence we could improve the efficiency of the system as compared with their individual mode of generation. This thesis describes renewable energy hybrid Wind-PV with battery energy storage system. In Hybrid Wind-PV System, PV system acts as a main source. This hybrid generation system can fully utilize the characteristics of the proposed wind generator and the PV panels to extract the maximum power from the wind and solar energy sources. Also, this hybrid generation system takes a distinct merit that the wind power and PV power inherently complement one another to certain extent, hence facilitating continuous output power from day to night. In this hybrid system with using fuel cell is more efficiency, long life and cheapest compare to hybrid system with using battery. The parameters of the controller can be further improved or advanced control method can be used. A computer measurement and control bus will be added to the system. Computer controlled relays will be added to allow all the major elements of the system to be switched in and out of the system through computer programs. The measurement bus will be connected to all the major signals in the system and will allow simultaneous data acquisition of all the major signals in the system. These improvements will allow the study of more complex issues such as power faults caused by sudden over voltages like lightning. In future to improve the stability and dynamics of grid connected Wind-PV generator. Some of question raised are:- Reference i. C. T. Pan, J. Y. Chen, C. P. Chu, and Y. S. Huang, A Fast Maximum Power Point Tracing for Photovoltaic Power Systems, in Proc. 1999 IEEE Industrial Electronics Society Conf., vol. 1, pp. 390-393. ii. J. A. Gow and C. D. Manning, Development of a Photovoltaic Array Model for Use in Power-electronics Simulation Studies, IEE Proc.-Electric Power Application, vol. 146, no. 2, pp. 193-200, March 1999. iii. M. J. Khan and M. T. Iqbal, Dynamic Modeling and Simulation of a Small Wind-Fuel Cell Hybrid Energy System, Renewable Energy, pp. 421-439, 2005. iv. S. M. Shaahid and M. A. Elhadidy, Technical and Economic Assessment of Gidindependent Hybrid Photovoltaic-Diesel-Battery Power Systems for Commercial Loads in Desert Environments, Renewable and Sustainable Energy Reviews, vol. 11, pp. 1794-1810, Oct. 2007. v. D. B. Nelson, M. H. Nehrir, and C. Wang, Unit Sizing and Cost Analysis of Stand-Alone Hybrid Wind/PV/Fuel Cell Power Generation Systems, Renewable Energy, pp. 1641-1656, Aug. 2006. vi. O. Ulleberg, Stand-alone Power Systems for the Future: Optimal Design, Operation and Control of Solar-Hydrogen Energy Systems, Ph.D. dissertation, Norwegian University of Science and Technology, vii. A. Albertini, M. G. Masi, G. Mazzanti, L. Peretto, and R. Tinarelli, Toward a BITE for real-time life estimation of capacitors subjected to thermal stress, IEEE Trans. Instrum. Meas., vol. 60, no. 5, pp. 1674 1681, May 2011. viii.. E. Roman, R. Alonso, P. Ibanez, S. Elorduizapatarietxe, and D. Goitia, Intelligent PV module for grid-connected PV systems, IEEE Trans. Ind. Electron., vol. 53, no. 4, pp. 1066 1073, Jun. 2006. doi : 10.17950/ijer/v4s12/1209 Page 679