Evaluation of Response Reduction Factor and Ductility Factor of RC Braced Frame

Similar documents
International Journal of Advance Engineering and Research Development. Assessment Of Response Reduction Factor For Asymmetric RC Frame Building

Assessment Response Reduction Factor of Elevated Tanks with Alternate RC Frame Staging Configurations

Comparative Study on Concentric Steel Braced Frame Structure due to Effect of Aspect Ratio using Pushover Analysis

Study of height on response reduction factor of RC water tank in zone IV

MODAL PUSHOVER ANALYSIS OF RC FRAME BUILDING WITH STAIRCASE AND ELEVATOR CORE

Evaluation Of Response Modification Factor For Moment Resisting Frames

EVALUATION OF RESPONSE REDUCTION FACTOR OF RC FRAMED BUILDINGS BY PUSHOVER ANALYSIS

Title. Author(s)ARDESHIR DEYLAMI; MOSTAFA FEGHHI. Issue Date Doc URL. Type. Note. File Information IRREGULARITY IN HEIGHT

Performance Based Plastic Design of Concentrically Braced Frame attuned with Indian Standard code and its Seismic Performance Evaluation

Study of height on response reduction factor of RC water tank in zone IV

National Information Service for Earthquake Engineering University of California, Berkeley

Effects of opening in shear walls of 30- storey building

Egyptian Code Seismic Load Design Provisions for Moment Resisting Frames

NON LINEAR STATIC ANALYSIS OF DUAL RC FRAME STRUCTURE

STUDY ON RESPONSE REDUCTION FACTOR OF CONCENTRICALLY BRACED STEEL FRAMES

International Journal of Intellectual Advancements and Research in Engineering Computations

A Performance Based Evaluation of a Wall- Frame Structure Employing the Pushover Analysis Tool

DESIGN AMPLIFICATION FACTOR FOR OPEN GROUND STOREY RC STRUCTURE WITH INFILL OPENINGS IN UPPER STOREYS

Seismic Performance of Multistorey Building with Soft Storey at Different Level with RC Shear Wall

PERFORMANCE BASED EVALUATION OF RESPONSE REDUCTION FACTOR FOR ELEVATED CIRCULAR WATER TANK

Static Analysis of Multistoreyed RC Buildings By Using Pushover Methodology

NON-LINEAR STATIC PUSHOVER ANALYSIS FOR MULTI-STORED BUILDING BY USING ETABS

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

PERFORMANCE BASED ANALYSIS OF R.C.C. FRAMES

Performance Based Seismic Design of Reinforced Concrete Building

SEISMIC VULNERABILITY ASSESSMENT OF STEEL PIPE SUPPORT STRUCTURES

An Investigation of Seismic Response Reduction Factor for Earthquake Resistant Design

International Journal of Scientific & Engineering Research, Volume 7, Issue 10, October ISSN Pushover Analysis of RC Building

International Journal of Engineering Research & Science (IJOER) ISSN: [ ] [Vol-3, Issue-3, March- 2017]

SEISMIC DEMAND STUDY OF SOFT STOREY BUILDING AND IT S STRENGTHENING FOR SEISMIC RESISTANCE

Effects of Strengthening Options in Improving the Lateral Responses of RC Frame Building

A Comparison of Basic Pushover Methods

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

A Comparative Study on Non-Linear Analysis of Frame with and without Structural Wall System

SEISMIC ANALYSIS OF REINFORCED CONCRETE STRUCTURES CONSIDERING DUCTILITY EFFECTS

Effect of Diaphragm Openings in Multi-storeyed RC framed buildings using Pushover analysis

APPLICATION OF PERFORMANCE - BASED DESIGN TO UPGRADE UNSYMMETRICAL RC BUILDING

Seismic Evaluation of Infilled RC Structures with Nonlinear Static Analysis Procedures

Pushover Analysis of High Rise Reinforced Concrete Building with and without Infill walls

PUSHOVER ANALYSIS FOR THE RC STRUCTURES WITH DIFFERENT ECCENTRICITY

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

Earthquake Resistant Design for Low Rise Open Ground Storey Famed Building

Study of P-Delta Effect on Tall Steel Structure

Assessment of Response Modification Factor of Open Steel Platform Structures Subjected to Seismic Loads

COMPARATIVE STUDY OF REINFORCED CONCRETE SHEAR WALL ANALYSIS IN MULTI- STOREYED BUILDING WITH OPENINGS BY NONLINEAR METHODS

Behaviour of Different Bracing Systems in High Rise 3-D Benchmark Building under Seismic Loadings

International Journal of Engineering and Techniques - Volume 4 Issue 2, Mar Apr 2018

PERFORMANCE BASED EVALUATION OF FRAMED REINFORCED CONCRETE SHEAR WALLS BY PUSHOVER ANALYSIS

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

EFFECTS OF SOFT FIRST STORY ON SEISMIC PERFORMANCE OF RC BUILDINGS AND SUSTAINABLE APPROACH TO RETROFIT

PERFORMANCE ASSESMENT OF RC BUILDING FRAMES BY NON LINEAR ANALYSIS

UPGRADING THE DUCTILITY AND SEISMIC BEHAVIOR FACTOR OF ORDINARY RC FRAMES USING FIBER COMPOSITE SHEETS

Concept of Earthquake Resistant Design

Comparative Study and Seismic Analysis of a Multistorey Steel Building

Department of Civil Engineering, SKP Engg. College, Tiruvanamalai, TN, India

TO STUDY THE PERFORMANCE OF HIGH-RISE BUILDING UNDER LATERAL LOAD WITH BARE FRAME AND SHEAR WALL WITH OPENINGS

Effect of Standard No Rules for Moment Resisting Frames on the Elastic and Inelastic Behavior of Dual Steel Systems

Pushover Analysis Of RCC Building With Soft Storey At Different Levels.

SEISMIC VULNERABILITY OF EXISTING RC BUILDINGS IN INDIA

Pushover Analysis of RC Bare Frame: Performance Comparison between Ductile and Non-ductile detailing

SEISMIC EVALUATION OF BUILDINGS WITH POSTTENSIONED BEAMS BY NON-LINEAR STATIC ANALYSIS

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 09, 2014 ISSN (online):

Analytical Study on Seismic Performance of Hybrid (DUAL) Structural System Subjected To Earthquake

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Effect of Mass and Stiffness of Vertically Irregular RC Structure

Seismic Assessment of an RC Building Using Pushover Analysis

Study on Response Modification Factor for Stiffened Steel Shear Wall Systems

Pushover Analysis of RC Frame for effective column design

A RATIONAL APPROACH TO ANALYTICAL MODELING OF MASONRY INFILLS IN REINFORCED CONCRETE FRAME BUILDINGS

Research Article Volume 6 Issue No. 7

Effect of Axial load on deformation capacity of RC column

Modelling for Seismic Analysis of RC Frame Buildings with Infill Wall and Special Shear Wall

Pushover Analysis of Multistoried Building

Improving the Seismic Response of a Reinforced Concrete Building Using Buckling Restrained Braces

Seismic behavior of Structures with Different Diaphragms and Infill Walls

Seismic Performance of Residential Buildings with Staggered Walls

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

Comparative Study of X-Concentrically Braced Frame, Zipper Frame and Strong Back System

SEISMIC RESPONSE OF A MID RISE RCC BUILDING WITH SOFT STOREY AT GROUND FLOOR

Index terms Diagrid, Nonlinear Static Analysis, SAP 2000.

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 08, 2016 ISSN (online):

PUSHOVER ANALYSIS (NON-LINEAR STATIC ANALYSIS) OF RC BUILDINGS USING SAP SOFTWARE

Optimal Knee Bracing System and Orientation for High Rise Steel Buildings under lateral loads

EVALUATION OF SEISMIC PERFORMANCE FACTORS FOR CHEVRON BUCKLING RESTRAINED BRACED FRAMES

Non Linear Static Analysis of Multi-storeyed Special Moment Resisting Frames

International Journal of Advance Engineering and Research Development A REVIEW ON PERFORMANCE BASED PLASTIC DESIGN METHODOLOGY

ENHANCING RESISTANCE CAPACITY OF SOFT STOREY BUILDING BY MEANS OF SHEARWALL INCORPORATED WITH STRUT

Optimum Position of Multi Outrigger Belt Truss in Tall Buildings Subjected to Earthquake and Wind Load

Application of Pushover Analysis for Evaluating Seismic Performance of RC Building

Exploring the Implication of Multi-plastic Hinge Design Concept of Structural Walls in Dual Systems

Inelastic seismic analysis of six storey RC building

Seismic performance assessment of reinforced concrete buildings using pushover analysis

Effects of Building Configuration on Seismic Performance of RC Buildings by Pushover Analysis

ctbuh.org/papers CTBUH Recommendations for the Seismic Design of High-Rise Buildings

Analysis the Behavior of Building with Different Soft Story

Seismic Analysis of Open Ground Storey Building

Seismic Assessment of Braced RC Frames

Inelastic Deformation Demands of Non-Ductile Reinforced Concrete Frames Strengthened with Buckling-Restrained Braces

COMPARATIVE SEISMIC PERFORMANCE OF RC FRAME BUILDINGS DESIGNED FOR ASCE 7 AND IS 1893

Transcription:

12 JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES 2 (215) 12 129 Research Paper Evaluation of Response Reduction Factor and Ductility Factor of RC Braced Frame Kruti Tamboli, J. A. Amin * Department of Civil Engineering, Sardar Vallabhbhai Patel Institute of Technology, Vasad, INDIA A R T I C L E I N F O A B S T R A C T Article history: Received 18 may 215 Revised 23 july 215 Accepted 7 september 215 Keywords: RC frame building Ductility Pushover analysis Response reduction factor is the factor by which the actual base shear force should be reduced, to obtain the design lateral force during design basic earthquake (DBE) shaking. The response reduction factor (R) is basically depends on Over strength (Rs), Ductility (Rµ), Redundancy (R R ). So there is a need to come up with realistic R factors for different structural systems used in various countries. In the present study efforts are made to evaluate the response reduction factor and ductility of RC braced frame using nonlinear static pushover analysis. The types of the frame considered in this study are RC frame with X bracing at centre bay, RC frame with X bracing at alternate bays, shear wall at canter and alternate bays. The result of this study shows that R factor and lateral strength of RC frames are considerably affected by the types and arrangement of the bracing system. Response reduction factor 1 Introduction The earthquake is a phenomenon that releases high amount of energy in a short time through the earth. Structures designed to resist moderate and frequently occurring earthquakes must have sufficient stiffness and strength to control deflection and prevent any possible collapse. In other words, a structure not only should dissipate a considerable amount of imported energy by ductile behaviour, but also it should be able to control the deformations and transfer the force to foundation through enough lateral stiffness in ground motions. Braced frame systems offer an attractive solution to satisfy multiple design objectives. Their elastic properties provide the stiffness and strength needed to achieve operational performance objectives, which are primarily defined by the performance of non-structural elements. Current force-based design procedure adopted by most seismic design codes allows the seismic design of building structures to be based on static or dynamic analyses of elastic models of the structure using elastic design spectra. The codes anticipate that structures will undergo inelastic deformations under strong seismic events; therefore, such inelastic behaviour is usually incorporated into the design by dividing the elastic spectra by a factor R which reduces the spectrum from its original * Corresponding author. Tel.: +91992554327. E-mail address: jamin_svit@yahoo.com e-issn: 217-127X, Mouloud Mammeri University of Tizi-Ouzou, Algeria

JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES 2 (215) 12 129 121 elastic demand level to a design level. The most important factors determining response reduction factors are the structural ductility and over strength capacity. Riddell et al. [1] evaluated response modification factors and ductility factors of short period buildings, where the reduction of linear elastic response spectra is smaller than the values for intermediate and long period structures for various sets of earthquake records. An idealized and simple variation of the response modification factor as a function of the period of vibration suitable for seismic codes formulation is also presented. Miranda [2] presented the different components of so called R factors and discusses how these can be incorporated into a performance-based earthquake resistant design. He also describes how strength reduction factors derived from single-degree-of-freedom systems need to be modified in order to be used in the design of multi -degree-of-freedom systems. Elanashai and Mwafy [3] addressed the issue of horizontal over strength in modern code/standard for design of reinforced-concrete (RC) buildings. The relationship between the lateral capacity, the design force reduction factor, the ductility level and the over strength factor are also investigated. Maheri and Akbari [4] evaluated the seismic behaviour factor for steel X-braced and knee-braced RC buildings using nonlinear pushover analyses of brace-frame systems having different heights and configurations. Authors concluded that Types of bracing had more localizes effects on the R factor. Mahmoudi and Zaree [5] evaluated the response modification factors of conventional concentric braced frames as well as buckling restrained braced frames. Authors concluded that the number of bracing bays and height of buildings have greater effect on the response modification factor. Kadid and Yahiaoui [6] investigated the seismic behaviour of RC buildings strengthened with different types of steel braces like X-bracing, inverted V bracing, ZX bracing and Zipper bracing. The R factors in many developing countries are often adopted from the well developed seismic design codes used in the United States or Europe. These R factors provide false representation for the structural practices applied in developing countries and thus considered unrealistic. Here in present study 4-storey RC building frame analyzed using static nonlinear pushover analysis and efforts are made to evaluate lateral strength, response reduction factor and ductility factor of RC braced frame. 2 Concept of Response Reduction Factor The code provision allows the structure to be damaged in the case of sever shaking. Hence, the structure is designed for seismic force much lesser than that expected under strong earthquakes, if the structure were to remain linearly elastic. Thus, the Indian seismic standard IS 1893 [7] provides a realistic force for an elastic structure and then divides that force by 2R. In other words, the term R gives an indication of the level of over strength and ductility that a structure is expected to have. Thus, the structure can be designed for much lower force than is implied by the strong shaking by considering the following factors, over strength factor (R S ), redundancy factor (R R ), ductility factor (R μ ) which will prevent the collapse of the structure. Over strength factor accounts for the yielding of a structure at load higher than the design load due to various Partial safety factors, strain hardening, oversized members, confinement of concrete. Non-structural elements also contribute to the over strength. According to ATC-19 [8], over strength R S is defined as the ratio of base shear at the roof displacement corresponding to the limiting state of response (V o ) to design seismic base shear (V d ) as per IS: 1893 (Part 1) 22 [7]. Redundancy factor depends on the number of vertical framing participate in seismic resistance. Yielding at one location in the structure does not imply yielding of the structure as a whole. Hence the load distribution, due to redundancy of the structure, provides additional safety margin. The values of redundancy factor as suggested by ATC-19 [8] are shown in Table 1. Table 1 - Value of Redundancy Factor Lines of vertical seismic framing Draft redundancy factor 2.71 3.86 4 1.

122 JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES 2 (215) 12 129 Ductility is the capacity of material/structure to absorb energy by deforming into the inelastic range. Ductility factor is a ratio of ultimate or code specified displacement to the yield displacement. In present study equation suggested by Miranda and Bertero [9] is used to evaluate the ductility factor R μ, R μ = (μ-1/φ) +1 (1) Where, For rock site: Φ = 1+ (1/ (1T-μT) (1-1.5(lnT-.6) ^2 /2T) (2) For alluvium site:2 Φ = 1+ (1/ (12T-μT) (2-2(lnT-.2) ^2 /5T) (3) For soft soil site: Φ = 1+ (T g /3T) (3T g -3(ln (T/Tg)-.25)^/4T) (4) T g is the predominant period of the ground motion. Total horizontal load Maximum force if structure is elastic Maximum load capacity Load at first yield Design force F 1 F des F el F y Linear elastic response Non-linear response Due to ductility Due to redundancy Due to over strength Total horizontal load w y Max Roof displacement Fig. 1 - Concept of response reduction factor 3 Frame Considered In This Study In the present study a typical 4-story RC frame has been taken for the analysis. The floor plan and elevation of the building is shown in figure 2. The building parameters are defined as, building plan dimension 18m x 9m, Concrete Grade M25, Steel Grade Fy 415 MPa, Slab Thickness 11mm, height of each storey 3.2m and height of ground storey is 4.2m. Live load is taken as 2 kn/m 2 at floor level and.75 kn/m 2 at roof level. It is assumed that the building is located in zone-iv and soil type is medium.

JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES 2 (215) 12 129 123 9m (3@ 3m c/c) 3m 3m 3m 3.2m 18m (4 @ 4.5m c/c) 3.2m 3.2m 4.2m Plan Elevation Fig. 2 - Plan and elevation of 4 storey building RC frame was designed using the most critical load combination of IS 456:2 [1] and IS1893:22[7]. Size and reinforcement details of designed beams and columns are shown in Tables 2 and 3 respectively. Table 2 - Beam size and reinforcement details Beam Beam size Top reinforcement Bottom reinforcement Ground/1 st story 3x45 3 bars of 2mm dia. 3 bars of 2mm dia. 2 nd story 3x45 3 bars of 18mm dia. 3 bars of 18mm dia. 3 rd story 3x45 3 bars of 16mm dia. 3 bars of 16mm dia. 4 th story 3x45 3 bars of 12mm dia. 3 bars of 12mm dia. Table 3 - Column size and reinforcement details Column Column size Top reinforcement Bottom reinforcement Ground/1 st story 3x45 4 bars of 2mm dia. 4 bars of 2mm dia. 2 nd story 3x45 3 bars of 2mm dia. 3 bars of 2mm dia. 3 rd story 3x45 2 bars of 2mm dia. 2 bars of 2mm dia. 4 th story 3x45 2 bars of 2mm dia. 2 bars of 2mm dia. In this study mid frame as shown in figure 2 is considered for the analysis. The calculated design seismic base shear (V B ) and corresponding lateral forces (Q i ) on the mid-frame as per IS: 1893, are shown in Table 4. Design seismic base shear, V b = A h.w (5) Where A h = (Z/2) x (I/R) x(s a /g) (design horizontal seismic coefficient for the structure) W= Seismic weight of frame

124 JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES 2 (215) 12 129 Z= Zone Factor =.24 (from Table 2 of IS 1893 (Part 1):22) I= Importance Factor = 1 (from Table 6 of IS 1893 (Part 1):22) R= Response Reduction Factor = 5 (from Table 7 of IS 1893 (Part 1):22) S a /g = average Response acceleration coefficient for medium soil = 2.5 (from Figure IS1893 (Part1):22) lateral forces at each storey level, Q i = ( V B W i h 2 i / ( W i h 2 i ) 2 (6) Table 4 - Storey forces for 4 storey building Floor level W i (kn) h i (m) 2 W i h i Q i (kn) Roof 269.418 13.8 5137.96 36.83 3 rd floor 399.726 1.6 44913.21 32.24 2 nd floor 399.726 7.4 21888.99 15.71 Groung/1 st floor 436.491 4.2 7699.7 5.52 155.361 W i h i 2 12589.8 V b = 9.32 Different RC frame configurations considered in the present study are: Bare frame RC frame with X-bracing in center bay RC frame with X-bracing in alternate bay RC frame with Shear wall in center bay RC frame with Shear wall in alternate bay 4 Analytical Modeling of Reinforced Concrete Members Plasticity in RC members was assumed to be lumped at probable locations. The program defined plastic hinge properties of SAP2 Program as per FEMA356 provisions were used to take into account the material nonlinearity. Flexural hinge properties involve axial force, bending moment as per FEMA356 provisions were used to take into account the material nonlinearity. Plastic hinges that generally develop are those corresponding to flexure and shear. Plastic hinges that generally interaction (P-M) as the failure envelop and bending moment rotation (M-θ) as the corresponding load deformation relation; shear hinge properties involve shear force-shear deformation relation (V- ). The different inelastic stages are suggested on pushover curves to facilitate the description of behaviour of different members of the RC frame building at various stages: : (1) P C1 : formation of plastic hinge in the first/ground-storey columns; (2) P B1 : formation of plastic hinges in first/ground-storey beams; (3) P C2 : formation of plastic hinge in the second-storey columns; (4) P B2 : formation of plastic hinges in second storey beams; (5) P C3 : formation of plastic hinge in the third-storey columns; (6) P B3 : formation of plastic hinges in third-storey beams; (7) P C4 : formation of plastic hinge in the roof-storey columns; (8) P B4 : formation of plastic hinges in roof-storey beams. 5 Bare RC Frame (RC-1) Bare frame represents the currently used common practice of not including the strength and stiffness of masonary in analysis and design procedure. The capacity curve obtained from the nonlinear pushover analysis of the bare RC frame building is shown in Figure 3. Linear behavior was observed in different member of RC frame upto a base shear of 15% of seismic weight and and upto a roof displacement corresponding to.5% drifts. Non-linearity was observed to be well distributed along the height of the frame. Failure of the frame was found to take place due to flexure failure of open ground storey columns at the ultimate lateral load corresponding to 17% of seismic weight and lateral drift of 2.4%.

JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES 2 (215) 12 129 125 % seismic weight 18 16 14 12 1 8 6 4 2 P B3 P C3 P C1 P B2 P C2 P B1 1 2 3 % drift Fig. 3 - Pushover curve for bare frame 6 RC Frame With X-Bracing Bracings as lateral load-resistant system are one of the most commonly used methods to resist lateral loads such as earthquake. The braced frame response to earthquake loading depends mainly on the asymmetric axial resistance of the bracing members. Conventional steel bracings dissipate considerable energy yielding under tension. Lateral load performance of the RC frame with X-bracing is studied for the following two cases: (1) Providing diagonal bracings in centre bay, and (2) Providing diagonal bracings in alternate bays. These diagonal braces were not designed formally because strength of such braces is usually very high. The size and reinforcement of bracing were kept identical to that of existing ground storey column of considered frame [Table 3]. 6.1 RC frame with X-bracing 9 (RC - B1) First inelastic activity was observed at lateral load corresponding to 33% of seismic weight and.15% drift [figure 4]. The ultimate strength of frame was found to be that corresponding to 48.76% of seismic weight and.34% of lateral drift. Plastic hinges were found to develop in the ground as well as upper storey members. However failure of plastic hinges was found to be concentrated in upper storey members. The value of response reduction factor and ductility factor was found to be 5.97 and 1.31 respectively. %seismic weight 6 5 4 3 2 1 P B1 P C2,P C3 P C1, P B2,P B3, P B4,1,2,3,4 %drift 6.2 RC frame with X-bracing in alternate bays (RC - B2) Fig. 4 - Pushover curve for RC bracing in center bay From capacity curve shown in Figure 5, it was observed that first inelastic activity was observed at lateral load corresponding to 4% of seismic weight and.19 % drift. The ultimate strength of frame was found to be that corresponding to 67.4% of seismic weight and.3% of lateral drift. Plastic hinges were found to develop in all the ground

126 JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES 2 (215) 12 129 as well as upper storey members. The value of response reduction factor and ductility factor was found to be 1.7 and 2.4 respectively. %seismic weight 8 7 6 5 4 3 2 1 P B4 P C2 P C3 P C1 P B2 P B3,1,2,3,4 %drift 7 RC Frame With Shear Wall Fig.5 - Pushover curve for RC bracing in alternate bay Another most commonly used lateral load-resistant system to resist lateral loads such as earthquake is the RC frame with shear wall. Lateral load performance of the RC frame with shear wall is studied for the following two cases: (1) Providing shear wall in centre bay, and (2) Providing shear wall in alternate bays. RC shear walls having a thickness of 19 mm are modelled using 4-noded nonlinear layered shell elements. The vertical and horizontal reinforcement ratio of.25% was used in shear wall. 7.1 RC frame with shear wall in center bay (RC - S1) In this case the frame was strengthened by providing RC shear wall in only center bay of all stories. The remaining two bays of all stories were left open. First inelastic activity was observed at lateral load corresponding to 49% of seismic weight and.23% drift (Figure 6). The ultimate strength of frame was found to be that corresponding to 65% of seismic weight and 1.6% of lateral drift. The value of response reduction factor and ductility factor was found to be 5.9 and.53 respectively. %seismic weight 7 6 5 4 3 2 1 P C2 P B2 P B3 P C1,5 1 1,5 2 %drift Fig. 6 - Pushover curve for shear wall in center bay

JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES 2 (215) 12 129 127 7.2 RC frame with shear wall in alternate bays (RC - S2) In this case the frame was strengthened by providing RC shear wall in alternate bays of all stories. The centre bay of all stories was left open. First inelastic activity was observed at lateral load corresponding to 8% of seismic weight and.27% drift (Figure 7). The ultimate strength of frame was found to be that corresponding to 16% of seismic weight and 1.58% of lateral drift. The value of response reduction factor and ductility factor was found to be 1.15 and.63 respectively for this type of frame. 12 %seismic weight 1 8 6 4 2 P B2 P C2 P B1 P C1,5 1 1,5 2 %drift Fig. 7 - Pushover curve for shear wall in alternate bay 8 Evaluation of Responses Reduction Factor and Ductility factor The calculation for evaluation of response reduction factor as per ATC-19 for bare RC frame in seismic zone-iv is shown below. The calculations of R factor for other frames are not shown here due to paucity of space. Estimation of strength factor: Maximum Base Shear (from pushover curve) Design Base shear (as per EQ calculation) Strength factor according to ATC 19 Estimation of ductility factor: Maximum drift capacity Yield drift (from pushover curve), Displacement ductility ratio according to ATC 19 V o = 224 kn V d = 9.32kN R s = V o / V d = 224 / 9.32 = 2.48 (.4 x H), Δm = 55.2 m Δy = 5 mm μ = Δm / Δy = 55.2 / 5 =1.1 Equation for ductility factor, derived by Miranda and Bertero [7] Φ for medium soil: R μ = {(μ - 1 / Φ) + 1} (7) Φ = 1+{1 /(12T -μt)} {(2 / 5T)*e- 2(ln(T).2)^2 } (8) T =.38seconds (From analysis) Φ = 1.17

128 JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES 2 (215) 12 129 Estimation of redundancy factor: Rμ = 1.8 The value of redundancy factor as suggested in ATC-19 is summaries in Table-1. Estimation of response reduction factor R: R= R S x Rμ x R R (9) R = 2.48 x 1.8 x 1 R = 2.7 Provision of bracing and shear wall in RC frame significantly increases its global strength as compared to bare frame. Table 5 shows the value of R-factor and its key component of considered RC frame in this study. The values of the response reduction factor are considerably affected by the types and arrangements of the bracing systems. Figure 8 shows the comparative values of response reduction factor for different types of RC frame considered in this study. Provision of bracing in alternate bays increases the values of responses reduction factor nearly 3.91 and 1.8 times respectively as compared to the RC frame with bracing at center bay and bare RC frame respectively. Provision of shear wall in alternate bays increases the values of responses reduction factor nearly 1.99 and 3.75 times respectively as compared to the RC frame with shear wall at center bay and bare RC frame respectively. Table 5 - Response reduction factor and its key component of RC frame Types of Frame R S R R R μ R μ Bare frame (RC-1) 2.48 1 1.8 2.7 1.1 RC bracing central bay (RC-B1) 5.3 1 1.19 5.97 1.31 RC bracing alternate bay (RC-B2) 9.66 1 1.9 1.57 2.4 Shear wall center bay (RC-S1) 1.47 1.48 5.9.535 Shear wall alternate bay (RC-S2) 16.91 1.6 1.15.63 R - Factor 12 1 8 6 4 2 RC-1 RC-B1 RC-B2 RC-S1 RC-S2 Types of frame Fig. 8 - Response reduction factor of RC frame

JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES 2 (215) 12 129 129 9 Conclusion In this study the lateral strength, ductility factor and response reduction factor (R) of 4-storey RC braced frame are evaluated using nonlinear static pushover analysis. The significant outcomes of the present study are summarized as follows: Large increase in lateral strength and stiffness of RC braced frame was observed as compared to bare RC frame. Yield lateral force for the RC frame with X-bracing at alternate bays was found to be 4% of seismic weight, and it was about 1.21 and 2.7 times more than that observed in the case of the RC frame with X-bracing at center bay and bare RC frame respectively. Ultimate lateral force for the RC frame with X-bracing at alternate bays was found to be 67.4% of seismic weight, and it was about 1.38 and 3.96 times more than that observed in the case of the RC frame with X-bracing at center bay and bare RC frame respectively. Yield lateral force for the RC frame with shear wall at alternate bays was found to be 1.6 and 5.3 times more than that observed in the case of the RC frame with shear wall at center bay and bare RC frame respectively. Ultimate lateral force for the RC frame with shear wall at alternate bays was found to be 1.6 and 6.2 times more than that observed in the case of the RC frame with shear wall at center bay and bare RC frame respectively. The response reduction factor of RC frame is considerably affected by the types and arrangements of the bracing systems. Provision of bracing/shear wall in alternate bays increases the values of responses reduction factor nearly 1.88 to 2.2 and 3.75 to 3.9 times respectively as compared to the RC frame with bracing/shear wall at center bay and bare RC frame respectively. REFERENCES [1]- R. Riddell, P. Hidalgo, E. Cruz, Response modification factors for earthquake resistant design of short period buildings. Earthquake Spectra, 5(3) (1989) 571-59. [2]- E. Miranda, Strength reduction factors in performance-based design. EERC-CURE symposium in Honour of Vitelmo V. Bertero, Berkeley, California, 1997. [3]- A.S. Elanashai, A.M. Mwafy, Over strength and force reduction factors of multi-storey reinforced-concrete buildings. Struct. Des. Tall Buil. 11(22) 329 351. [4]- M.R. Maheri, R. Akbari, Seismic behaviour factor R for steel X-braced and knee-braced RC buildings. Eng. Struct. 25(23) 155-1513. [5]- M. Mahmoudi, M. Zaree, Evaluating response modification factors of concentrically braced steel frames. J. Constr. Steel Res. 66(21) 1196-124. [6]- A. Kadid, D. Yahiaoui, Seismic assessment of braced RC frames. In: The Proceedings of the Twelfth East Asia- Pacific Conference on Structural Engineering and Construction - EASEC12, Procedia Eng. 14(211) 2899 295. [7]- IS: 1893, Indian Standard criteria for earthquake resistant design of structures. Part 1: General provisions and buildings. Bureau of Indian Standards, New Delhi, India, 22. [8]- ATC: 19, Structural response modification factors, Applied technology council, Redwood city, California, 1995. [9]- E. Miranda, V. Bertero, Evaluation of strength reduction factors for earthquake resistant design. Earthquake Spectra 1(2) (1994) 357-379. [1]- IS: 456, Plain and Reinforced Concrete - Code of Practice. Bureau of Indian Standards New Delhi, India, 2.