Masonry Veneer - Chapter 6. Masonry Veneer Anchored Veneer

Similar documents
Stone and Masonry Veneer

CONCRETE MASONRY VENEERS TEK 3-6C

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses. DD No

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Design Guide Revised 11/17/2016

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Overview Revised 11/17/2016

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

LOK-N-BLOK PRODUCT INTRODUCTION ICC-ES June 5, 2018

BUILDING CODE REQUIREMENTS FOR BRICK VENEER IN SEISMIC AREAS

A n c h o r a g e. M o v e m e n t. M o i s t ur e A SYSTEMS APPROACH TO THE DESIGN AND EXECUTION OF MASONRY CAVITY AND VENEER WALL SYSTEMS

SECTION NON--STRUCTURAL METAL FRAMING

CONNECTOR S T U D S H E A R. Design for Composite Structural Action STUD SHEAR CONNECTOR APPLICATION

Proposed Modification to the Florida Building Code

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

CONNECTOR B L O C K S H E A R. Design for Composite Structural Action BLOCK SHEAR CONNECTOR APPLICATION. Airspace

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Technical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

WALL SYSTEMS ( Ref: The Building Illustrated, Ching, Francis DK )

THE FLORIDA BUILDING CODE

NCMA TEK RESIDENTIAL DETAILS FOR HIGH WIND AREAS. TEK 5-11 Details (2003)

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code

Brick Veneer / Wood Stud Walls

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

CHAPTER 21 MASONRY SECTION 2101 GENERAL

FIRE RESISTANCE TESTS OF BRICK VENEER / WOOD FRAME WALLS J. GREGG BORCHELT

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Construction Details 5-37

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Accommodating Expansion of Brickwork

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

Detail Drawings THE BEST PANEL COMPANY. from. 126 Old Highway 60 East Hardinsburg, Kentucky Office:

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

CHIMNEYS AND FIREPLACES

Chapter 2 QUALITY ASSURANCE

Openings in Walls I: Reinforcement

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Originally Issued: 03/31/2017 Revised: 03/15/2018 Valid Through: 03/31/2018

Pulaski County, Virginia Practical Wall Bracing

WEIGHT PER PIECE (LBS.)

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

BEARING METAL STUD FRAMING

CHIMNEYS AND FIREPLACES

SECTION UNIT MASONRY SYSTEM

1.02 STANDARD REFERENCES: The following standard specifications shall apply to the Work of this Section as indicated:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

PS 3000 Installation Manual Step-By-Step Procedures C.9. DOOR AND WINDOW OPENINGS C.9.1 PREPARE IN ADVANCE. C.9.2 VBUCK CONSTRUCTION.

Masonry and Cold-Formed Steel Requirements

Contents. 1.1 Introduction 1

BRICK CONSTRUCTION DETAILS

POST FRAME BUILDING STANDARDS

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

Composite / Veneer Units. Precision...1. Split Face... 2

Module number 3 provides an on-line, self-paced training seminar on chapter 4, foundations and chapter 5, floors from the residential code of ohio.

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

SECTION UNIT MASONRY

Structural Option Indiana Regional Medical Center Indiana, PA

Earthquake Resistant Residential Design and Construction, Part 2

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

FEMA P-593 STEP-BY STEP PRESCRIPTIVE RETROFIT FOR CRIPPLE WALL BRACING & ANCHORAGE TO FOUNDATION

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

Administrative Changes

W. Mark McGinley March 3, 2016 ISEA MEETINGS 1

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

Building Division Informational Handout

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2011 LARC)

Diaphragms 2. Design Process. Design Process. Diaphragms are the roofs and floors of the upper stories

RESIDENTIAL DETACHED ACCESSORY STRUCTURES

EASTERN ARCHITECTURAL SYSTEMS SERIES HRP 1000F HORIZONTAL ROLLER - LMI

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

MASONRY ANCHORS AND CONNECTORS May 6, 2014

WALL CONSTRUCTION CHAPTER 6

APPENDIX A1 WIND AND SEISMIC BRACING GUIDELINE FOR ONE AND TWO FAMILY DWELLINGS AND TOWNHOUSES

Technical Notes on Brick Construction Brick Industry Association Commerce Park Drive, Reston, Virginia 20191

MASONRY WALL DATA: Wall Height = ft. Nominal Wall Thickness = 8.00 in. Depth to c.g. Steel, Wall = 3.81 in.

R Code and Commentary for 2012 NC Residential Code final 03/06/13

August 31, Myrna Webber Managing Broker 201 West Springfield Ave., 11 th Floor P.O. Box 140 Champaign, IL

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

Acknowledgments. Abstract

Table of Contents 2. Structural Systems.4 Foundations.4 Floor System...4 Columns..5 Lateral System...5

ISSUE A Code Change # 2 Class 3 and Class 4 Buildings

International Code Council

DIVISION: SPECIALTIES SECTION: MANUFACTURED FIREPLACES REPORT HOLDER: FIRE ROCK PRODUCTS LLC

AC R1 # Triangle Parkway Suite 100 Norcross, Ga Phone: Fax: AC R1. September 11, 2012

WALL CONSTRUCTION CHAPTER 6

ALTERNATE DESIGN METHODOLOGY FOR UNREINFORCED MASONRY BUILDINGS

NC 2009 Residential Code changes (Highlights on changes between the 2006 and 2009 NC Residential Code)

Wall bracing panel requirements

Wood framing has become increasingly popular. Designing. Differential Movement. Clay brick veneer over wood frame construction.

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space

Technical Notes 28 - Anchored Brick Veneer, Wood Frame Construction Rev August 2002

Residential Deck Guide

Misericordia University Field House Project - Dallas, PA SECTION UNIT MASONRY

Acknowledgments. Abstract

LIGHT-GAUGE PANELIZED WALL SYSTEMS. Michael Waggoner Mark Schroeder

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Transcription:

Masonry Veneer - Chapter 6 Chapter 6 covers anchored and adhered veneer. Following are prescriptive requirements for areas with wind 110 mph Vertical support of masonry veneer Support: Noncombustible structural Preservative-treated wood foundation Wood construction Interior finish on wood framing Deflection of floor, lintel, or wood support Backing Masonry or concrete Wood framing Cold-formed steel framing No height limitation Height 18 ft Weight 40 psf; height 12ft Weight 40 psf L/600 or 0.3 in No height limitation Height 30 ft at plate; 38 ft at gable Support by noncombustible construction at each story above 30 ft at plate or 38 ft at gable Unreinforced Masonry 1 Masonry Veneer Anchored Veneer Unreinforced Masonry 2

Masonry Veneer - Anchor Types Corrugated Sheet Metal Joint reinforcement Sheet Metal Adjustable Wire anchors Unreinforced Masonry 3 Masonry Veneer Wall Anchorage Details Unreinforced Masonry 4

Anchor type Anchor type Corrugated sheet metal anchor 7/8 in wide; 0.03 in thick Corrugation wave length of 0.3 to 0.5 in Corrugation amplitude of 0.06 to 0.10 in Sheet metal 7/8 in wide; 0.0606 in thick Corrugated, bent, notched, or punched Wire anchors W1.7 wire with ends bent to form at least a 2 in extension Joint reinforcement W1.7 cross wires at maximum spacing of 16 in o.c. Embed longitudinal wire into mortar joint with at least 5/8 in in mortar on each side Adjustable Maximum clearance between connected parts of 1/16 in Two pintle legs of W2.8 wires with offset 1 1/4 in Unreinforced Masonry 5 Anchor spacing Wall area supported by anchor Adjustable two-piece, W1.7 wire, or corrugated sheet metal All other anchors 2.67 ft 2 3.5 ft 2 Maximum spacing 32 in horizontally; 18 in vertically Spacing at opening 16 in. in either dimension 3 ft on center within 12 in of opening High wind areas (110 mph < v 130 mph) Reduce supported wall area to 70% of above requirement Maximum spacing is 18 in horizontally and vertically Anchor spacing around openings reduced to 24 in Unreinforced Masonry 6

Veneer backing Wood framing Any anchor type permitted Attach anchor to wood with corrosion resistant 8d common nail Nail within 1/2 in of 90 degree bend for corrugated sheet metal anchors 4.5 in maximum cavity, except 1 in maximum cavity with corrugated sheet metal anchors 1 in minimum air space Steel Adjustable anchors Corrosion resistant framing with minimum base metal thickness of 0043i 0.043 in Corrosion resistant screws with minimum nominal shank diameter of 0.190 in 4.5 in maximum cavity; 1 in minimum air space Masonry or concrete Masonry backing Concrete backing 4.5 in maximum cavity; 1 in minimum air space Wire, joint reinforcement, or adjustable anchors Adjustable anchors only Stack bond veneer: Single W1.7 wire joint reinforcement at 18 in o.c. Unreinforced Masonry 7 Masonry Veneer Seismic s Seismic Performance Category C D Isolate top and sides from vertical and lateral seismic forces Reduce maximum wall area supported by each anchor by 25% (vertical and horizontal spacings remain unchanged) E Vertical expansion joints at all returns and corners Mechanically attach veneer joint reinforcement to anchors with clips or hooks Support weight independently at each story Single-wire W1.7 joint reinforcement at 18 in o.c. Unreinforced Masonry 8

Glass Unit Masonry - Chapter 7 Standard size: 3 7 / 8 in thick Thin size: 3 1 / 8 in thick hollow; 3 in thick solid Location Standard Units Thin Units Exterior Figure 7.3-1 85ft 2 ; 15 ft wide; 10 ft high wind 25 ft wide; 20 ft high pressure 20 psf Interior 250ft 2 ; 25 ft wide; 20 ft high 150ft 2 ; 25 ft wide; 20 ft high Approximation to Fig 7.3-1 (r 2 =0.992) Panel area ( 2 ft ) 1360[Wind pressure ( psf )] 0.766 Lateral support: Anchors at 16 in on center or recess glass 1 in into channels; must be able to support applied load or 200 lb/ft. Isolation: Isolate from in-plane loads Expansion Joints: 3/8 inch along top and sides Reinforcement: Horizontal joint reinforcement at 16 in o.c. of 2-W1.7 wires Unreinforced Masonry 9