Technical Assistance by JICA TRANSITIONAL PROJECT IMPLEMENTATION SUPPORT FOR EMERGENCY RECONSTRUCTION PROJECTS IN NEPAL

Similar documents
Project Introduction TRANSITIONAL PROJECT IMPLEMENTATION SUPPORT FOR EMERGENCY RECONSTRUCTION PROJECTS IN NEPAL

DESIGN CATALOGUE FOR RECONSTRUCTION OF EARTHQUAKE RESISTANT HOUSES

Confined masonry. An illustrated guide for masons. This manual explains this technique. Confined masonry. RC frames. Columns first, walls after

POST- EARTHQUAKE RETROFITTING IN NEPAL. 22nd November 2016

KEEP YOUR FAMILY SAFER FROM EARTHQUAKES AND TYPHOONS BY MAKING SURE YOUR HOUSE FOLLOWS THESE 6 BASIC PRINCIPLES

Self Locating Wall System

S E I S M I C RETROFITTING GUIDELINES

Volume 1. HOW TO MAKE A DREAM HOUSE EARTHQUAKE RESISTANT Contents

Fence Stone. Self locating Wall System

Stone and Masonry Veneer

Product Information Bulletin

Department of Urban Development and Building Construction

BRICKWORK 3.5 BRICKWORK 1 GENERAL

5.3.1 Water seal Positioning the toilet pan 12

DESIGN AND MASONRY BASIC DESIGN GUIDELINES FOR CSEB. General principles for a good design

CONCRETE BLOCK MASONRY

Monitoring and Evaluation of Reconstruction Activities

UNIT III Earthwork Estimation & Reinforcement Estimation

APPENDIX 5: CONSTRUCTION CHECKLISTS

Scanned by CamScanner

Bhatar construction. An illustrated guide for craftsmen

UNIT-1 RETAINING WALLS

SEISMIC RETROFITTING OF EXISTING BUILDINGS

Armopanel Concrete Wall System. Design Guide B-3.1. BASEMENT WALLS

Training Workshop on Building Code Implementation"

NATIONAL INSTITUTE OF ANIMAL BIOTECHNOLOGY (NIAB), HYDERABAD

Training Workshop on Building Code Implementation Organized jointly by

EARTHQUAKE SAFE CONSTRUCTION OF MASONRY BUILDINGS Simplified Guideline for All New Buildings in the Seismic Zone III of India

WORK BELOW LOWEST FLOOR FINISH 1/7 230, , , FRAME 2/6 96, , ,056.00

SEISMIC CODE EVALUATION ST. LUCIA Evaluation conducted by Myron W. Chin

ITEM No. D E S C R I P T I O N UNIT QTY. 5-E343.2 In class III material m³ 1,260 - Max. Depth: m For disposal

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: EPI/WRO/CON/757/0119 FOR

PARTICULAR SPECIFICATIONS MASONRY WORK BRICK WORK

Lesson learnt from Nepal Earthquake

Interiors Sources Decor LLC. Method Statement BLOCK WORK. Civil Works 6/26/2016

Conditions of the Contract and Division 1 General Requirements are a part of this section.

"Impact of New IS 1893 & Related Codes on Design of tall Buildings, Including Trend Setting Structures

INSPECTION MANUAL. for Houses that has been built under HOUSING RECONSTRUCTION PROGRAMME. Government of Nepal National reconstruction authority

Drainage, Road Drainage and Collection Pit A - EXCAVATION:

Building Construction

Unit 4 Brick Masonry. Part Ⅰ Illustrated Words and Concepts. Figure 4-1 Basic Vocabulary of Bricklaying

Langtang reconstruction/ working document

NSET EXPERIENCE ON SEISMIC RETROFITTING OF MASONRY AND RC FRAME BUILDINGS IN NEPAL

RETAINING WALL LEVEL BACKFILL

Estimate FOR THE SEPTIC TANK

Documentation of the Seismic Evaluation and Retrofit Process

Ductile Detailing for Earthquake Resistant R C Structures. Dr. S. K. PRASAD Professor of Civil Engineering S.J. College of Engineering Mysore

freestone eco Prestige & quality DIY vertical wall Large blocks - 10/m 2 Smooth surface finish No concrete footings

Seismic Vulnerability Assessment and Retrofit Design of Heritage Buildings of Kathmandu Valley Kirti TIWARI 1, Hima SHRESTHA 2 and Ramesh GURAGAIN 3 1

Strengthening or Retrofitting

SECTION MORTAR

CE2401-DESIGN OF REINFORCED CONCRETE AND BRICK MASONRY QUESTION BANK

Bordeaux Walling. Product & Technical Information

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

Click on image to enlarge.

APPLICATION FOR A BUILDING PERMIT (Retaining Wall/Garden Wall Construction Details)

Confined masonry. Definition

1.02 STANDARD REFERENCES: The following standard specifications shall apply to the Work of this Section as indicated:

YTONG. Aerated Concrete Solution

Building Division Informational Handout

Saudi Vitrified Clay Pipe Co.

PRICED BILL OF QUANTITIES

Retaining Wall Products

Sabah Shawkat Cabinet of Structural Engineering 2017

PART A: JOB PROCDRE FOR PLASTERING

CERTIFICATE OF APPROVAL No CF 5207 QATAR AERATED CONCRETE INDUSTRIES CO. W.W.L.

roofing ROOFING Design of the base ROOFING DETAILS

The Passive Fire Protection Handbook

3.3 Wall Construction

Experimental Study on behavior of Interior RC Beam Column Joints Subjected to Cyclic Loading P.Rajaram 1 A.Murugesan 2 and G.S.

New Zealand Concrete Masonry Manual

ENGINEERING DIRECTIVE

APPENDIX 1: UNDERSTANDING CAUSES OF COLLAPSE OF CONFINED MASONRY HOUSES IN INDONESIA

1-2-3MORTAR Modified Portland cement based mortar, to be used to adhere any prefabricated construction elements

Unit Rate. Subtotal in SDG. Site Clearing Preliminary Works. 1.0 Job. Excavation & Earth Works. Stone Masonry Works in foundation 100 M.

Concrete Slab-on-Ground

1:100 GABION WALLS LEGEND NOT FOR CONSTRUCTION TYPICAL DRAWING TEXT SETTING TYPE CHARACTER HEIGHT PEN SETUP FOR PLOTTING SUBTITLE

Est. Cost : Rs.40,000/-

SECTION UTILITY MANHOLES AND STRUCTURES

SAFE WORK PROCEDURE 037 STORMWATER DRAINAGE CONSTRUCTION MARCH 2014 DOC. NO. D14/184659

Mason s Training Programme on Onsite Treatment Systems

1 Exam Prep Concrete Masonry Handbook Questions and Answers

Construction Specification for Utility Adjustments

AUGUST 2017 HASTINGS. retaining walls installation guide

Paragraph Description Page No General Materials Concrete Masonry Work Altitude Valve Vault Cover 25-4

ENG.ACA.0001F Madras. New Zealand significant. (a) spandrel 2010) were solid

SECTION 39 - MANHOLES TABLE OF CONTENTS 39-1 GENERAL PRECAST CONCRETE MANHOLES

w w w. m d u e. i t - i n f m d u e. i t

Bear Exhibit Fence Upgrades. The following modifications are hereby made part of the contract documents:

TABLE OF CONTENTS

This type of masonry shall consist of brick laid in full beds of cement mortar.

Features Include: Near Vertical Walls Do it Yourself No Concrete Footings Required

Home Not Anchored to Foundation

Description Unit Quantity Rate Kshs. Amount Kshs.

MagnumStone Specifications Gravity

A.2.a Random Riprap... Table

Table of Contents NOTE:

Reinforced Masonry Structure

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

NOVEMBER 2016 GRANDWALL. retaining walls installation guide

Transcription:

Technical Assistance by JICA TRANSITIONAL PROJECT IMPLEMENTATION SUPPORT FOR EMERGENCY RECONSTRUCTION PROJECTS IN NEPAL 1

Field Level Mason Training House-owner Training TOT for DUDBC Engineer Mobile Team for Survey and Assistance/Public Awareness Campaign Inspection Training for DUDBC Engineers Refresher Training for Mason Central Level Housing Design Catalogue Minimum Requirements for masonry structure, (Poster, Handbook) Training materials (Guidebook, Handbook, Technical Video) Inspection Manual, Inspection training curriculum Correction Manual (A part of Retrofitting manual) Compliance Catalogue 2

JICA Target Districts 3

Mason Training Total Number of Trained mason : 1431 (Gorkha: 427, Sindhupalchok: 1004) 4

House-owner Training Total Number of House-owner: 3647 (Gorkha: 1065, Sindhupalchok: 2582) 5

TOT for DUDBC Engineer Total Number of Engineer: 440 Engineer Sub Engineer Assistant of Sub Engineer Gorha 115 28 46 Sindhupalchok 139 54 58 6

Mobile Team for Survey and Assistance Public Awareness Campaign 7

Housing Design Catalogue, volume 1 NBC/IS JMA Kobe 8

Structural calculation/ analysis 9

Minimum Requirements Minimum Requirements (MRs) for Stone Masonry in Cement Mortar (NBC202) No. Category 1 Site Selection No. of story Span of wall 2 Shape of House Size of room 3 Foundation 4 Plinth A building shall not be constructed if site is: Height of wall Proportion General Depth Width General Height Width Reinforcement Geological fault or Raptured Area Areas Susceptible to Landslide Steep Slope > 20% Filled Area River Bank and Water-logged Area Up to two-storied load-bearing masonry buildings constructed in cement mortar. The span of wall shall not more than 4.5 meters The area of individual floor panel not more than 13.5 square metres The height of wall should not be more than 3.0 meters The house shall be planned in square, rectangular. Avoid long and narrow structure should not be more than 3 times of its width. The foundation trench shall be of uniform width. The foundation bed shall be on the same level throughout the foundation in flat area. The depth of footing should not be less than 800mm for one story, 900mm for two storey. The width of footing should not be less than 600mm in medium soil condition. As depend on soil condition. Shown in detail drawings. Provide a reinforced concrete band at plinth level, as shown in detail drawings. The top level of plinth should not be less than 300mm from existing ground level. Recommendation is 450mm. Minimum height of Plinth band is 150mm. Page1 Minimum thickness of plinth band width should be equal to wall thickness. 350mm for Stone masorny. Main reinforcement should be 4-12 dia. bars. Use 6mm diameter rings at 150mm. Hook length should be 500mm. Bars shall have a clear cover of 25mm concrete. 5 Walls General Joints Through Stone Masonry should not be laid staggered or straggled in order to avoid continuous vertical joints. At corners or wall junctions, through vertical joints should be avoided by properly laying the masonry. It should be interlocked. Mortar joints should not be more than 20mm and less than 10mm in thickness. The ratio recommend 1:4 (Cement: Sand). Through-stone of a length equal to the full wall thickness should be used in every 600 mm lift at not more than 1.2 m apart horizontally. Handbook of MR Width The minimum width of wall is 350mm for one-storey and two-storey. MR of SMC 10

JICA Target Districts Minimum Requirement Construction Sequence Poster Minimum Requirements Poster 11

Inspection Materials NRA Inspection Guidelines Inspection Manual 12

Inspection Guidelines Procedure and Forms Inspection Sheet 13

Inspection Training for DUDBC Engineer Time Session Day 1 Session Day 2 9:00 9:30 S 1.0 Opening Ceremony S 2.0 Review of Previous day 9:30 10:15 S 1.1 Inspection Guidelines and Forms 10:15 11:00 S 1.2 Responsibility of stake holder S 2.1 Class Exercise for Inspection 11:00 11:45 S 1.3 MIS and Use of Tablet S 2.2 Field Visit Briefing and Preparation 11:45 12:45 Lunch Lunch 12:45 13:30 S 1.4 Overview of Construction Sequence 13:30 14:15 S 1.5 General consideration for Construction S 2.3 Field Visit 14:15 14:45 Tea Break Tea Break 14:45 15:30 S 1.6 Masonry Procedure 15:30 16:15 S 1.7 R.C. frame Procedure S 2.4 Field Visit discussion 16:15 17:00 S 1.8 Review of the day S 2.5 Closing and Certification 14

Activity Plan from now on Field Level Mason Training House-owner Training TOT for DL-PIU Engineer Mobile Team for Survey and Assistance/Public Awareness Campaign Inspection Training for DUDBC Engineers Refresher Training for Mason Central Level Housing Design Catalogue, Vol. 1 Minimum Requirements for masonry structure, (Poster, Handbook) Training materials (Guidebook, Handbook, Technical Video) Inspection Manual, Inspection training curriculum Housing Design Catalogue, Vol. 2 Collection Manual (A part of Retrofitting) 15

Activity Plan from now on Housing Design Catalogue, Vol. 2 There is no specification of Timber structure, Concrete Block, Stabilized Soil Block, etc on NBC. It takes time to set Minimum Requirement of these methods. It is better to make fix design in the catalogue. 16

Activity Plan from now on Correction Manual Target: New construction Ex. Adding horizontal band Non-compliance construction can be appeared during inspection. Need of Correction / Retrofitting. Ex. Adding Vertical element Correction manual should be developed as a part of retrofitting. 17

Activity Plan from now on Developing Retrofitting Method Jacketing (Full/Partial) Shaking Table Test Jacketing (Gabion type) Pull Down Test 18