ELECTRICAL RESISTIVITY AS A FUNCTION OF TEMPERATURE

Good Practice Guide for nanoindentation of nanoparticles embedded in a layer using an SEM in situ technique

Specimen configuration

Micro-Structural Observation of the Bonding Interface between Au Wire and a Platinum Electrode

R Sensor resistance (Ω) ρ Specific resistivity of bulk Silicon (Ω cm) d Diameter of measuring point (cm)

MODEL PicoMill TEM specimen preparation system. Achieve ultimate specimen quality free from amorphous and implanted layers

Sr and Pb additions. L. Affleck, C. Leach *

New I.R. Thermography methodology for failure analysis on tantalum capacitors

CONTENTS. Introduction. NSOM Optical Fiber Probes

CX Thin Fil s. Resistors Attenuators Thin-Film Products Thin-Film Services. ISO 9001:2008 RoHS/REACH Compliant ITAR Compliant

4-pocket Electron Beam Evaporator E-Beam Evaporator

Specimen Preparation Technique for a Microstructure Analysis Using the Focused Ion Beam Process

The Effect of Annealing on Resistivity Measurements of TiSi 2 and TiN Using the collinear Four Point Probe Technique

Focused Ion Beam CENTRE INTERDISCIPLINAIRE DE MICROSCOPIE ELECTRONIQUE. Marco Cantoni, EPFL-CIME CIME ASSEMBLEE GENERALE 2007

Simple method for formation of nanometer scale holes in membranes. E. O. Lawrence Berkeley National Laboratory, Berkeley, CA 94720

Thin Films: Sputtering Systems (Jaeger Ch 6 & Ruska Ch 7,) Sputtering: gas plasma transfers atoms from target to substrate Can deposit any material

Packaging Technologies for SiC Power Modules

Silver Diffusion Bonding and Layer Transfer of Lithium Niobate to Silicon

Searching for new API Polymorphs Crystal Structure Determination of Pharmaceutical crystals using Electron Diffraction Tomography

In Situ Observation of Dislocation Nucleation and Escape in a Submicron Al Single Crystal

Bonding Technique Using Micro-Scaled Silver-Oxide Particles for In-Situ Formation of Silver Nanoparticles

From Eye to Insight. Leica EM ACE. Coater Family

SEMATECH Symposium Korea 2012 Practical Analysis Techniques of Nanostructured Semiconductors by Electron Microscopy

TIMAwave a novel test stand for thermal diffusivity measurement based on the Angstrom s method

SUPPLEMENTARY INFORMATIONS

zyvex TEM Sample Lift-out Using the Zyvex Nanoprober System By Kimberly Tuck, Zyvex Corporation

Scanning thermal microscopy probe capable of simultaneous electrical imaging and the addition of a diamond tip

John de Laeter Centre

Application Note. Sample Protection prior to FIB Processing. related instruments: Leica EM ACE600. Material Research. Life Science Research

Using Zyvex Microgrippers TM with Zyvex Nanomanipulators

Evaluation of Interfacial Bonding Utilizing Ag 2 O-Derived Silver Nanoparticles Using TEM Observation and Molecular Dynamics Simulation

MODEL SEM Mill. Two independently adjustable TrueFocus ion sources

Small-Scale Mechanical Testing at Michigan Technological University Houghton, MI

Microstructure Analysis by Means of the Orthogonallyarranged

Materials Characterization for Stress Management

FEI Materials Science Driving Discovery Through Innovative Solutions

Supplementary Figure S1 Photograph of MoS 2 and WS 2 flakes exfoliated by different metal naphthalenide (metal = Na, K, Li), and dispersed in water.

MODEL 1051 TEM Mill ION MILLING. Ion milling is used on physical science. specimens to reduce thickness to electron

Advanced Manufacturing Choices

Deformation and fracture of an alpha/beta titanium alloy

Electron Microscopy Sciences Industry Road. P.O. Box 550. Hatfield, PA Introduction. DuraSiNTM

STUDY & ANALYSIS OF ALUMINIUM FOIL AND ANATASE TITANIUM OXIDE (TiO2) USING TRANSMISSION ELECTRON MICROSCOPY

Diffraction Contrast Tomography. Unlocking Crystallographic Information from Laboratory X-ray Microscopy. Technical Note

Chapter 2 Capacitive Sensing Electrodes

Transmission electron microscopy a versatile tool to study the microstructure of HT-PEMFC

Influence of Alloy Microstructure on Oxide Growth in HCM12A in Supercritical Water

Industrial Applications. Cool Laser Machining.

Installation of a Scanning Electron Microscope in the Hot-cell Laboratory of NRG Petten

Studies on Atmospheric Non-Thermal Plasma Jet Device

NOVEL MATERIALS FOR IMPROVED QUALITY OF RF-PA IN BASE-STATION APPLICATIONS

TransGuard. AVX Multilayer Ceramic Transient Voltage Suppressors GENERAL DESCRIPTION TRANSGUARD DESCRIPTION

In-situ monitoring of optical near-field material processing by electron microscopes

Quantitative Analysis of Atomic-scale Alloying Elements Using TEM

MATERIALS. Sample Preparation & Grids for SEM & TEM... L 17 L 01. MATERIALS / Inorganics & thin films guide

Supplementary Information: Hybrid polymer photonic crystal fiber with integrated chalcogenide. glass nanofilms

TFA Thin Film Analyzer

MODEL TEM Mill. Two independently adjustable TrueFocus ion sources

ELECTRON MICROSCOPY MODERN SURFACE, LAYER AND DEFECT ANALYSIS USING REM, FIB, EDX, STEM

Texture Analysis in MSE

Chemically Tunable Full Spectrum Optical Properties of 2D Silicon Telluride Nanoplates

SUPPLEMENTARY INFORMATION

PoDFA The complete solution for inclusion measurement Inclusion identification and quantification analysis

CRYSTAL STRUCTURE DETERMINATION OF PHARMACEUTICALS WITH ELECTRON DIFFRACTION

Small-Scale Resistance Welding for Medical and Industrial Applications

Electron Probe Micro-Analysis (EPMA)

HALL-EFFECT. L79 / HCS-Hall Characterization System

Focused helium-ion beam irradiation effects on electrical transport

# 31. Mounting Considerations for High Power Laser Diodes

TED PELLA, INC. Microscopy Products for Science and Industry

Model TEM Mill. Tabletop precision preparation for producing high-quality TEM specimens from a wide variety of materials EXCELLENCE MAGNIFIED

Change in stoichiometry

Laser Micromachining for Industrial Applications and R&D. 3D-Micromac AG. Symposium on Smart Integrated Systems in Chemnitz. 3D-Micromac AG

Model Plasma Cleaner. Effectively cleans specimens for electron microscopy EXCELLENCE MAGNIFIED

Surface Coating of Tungsten Carbide by Electric Exploding of Contact

Nanoscale Imaging, Material Removal and Deposition for Fabrication of Cutting-edge Semiconductor Devices

Layer Thickness Analysis of Thin Metal Coatings with. Bruker Nano Analytics, Berlin, Germany Webinar, June 8 th 2017

ECE 440 Lecture 27 : Equilibrium P-N Junctions I Class Outline:

Electrical Characterization of Tungsten Nanowires Deposited by Focused Ion Beam (FIB) *

EBSD Electron BackScatter Diffraction Principle and Applications

In-situ Electron Microscopy Mechanical Testing for Steels

VERSATILE MULTIPURPOSE HEATERS RANGE

Future Electronic Devices Technology in Cosmic Space and Lead-free Solder Joint Reliability

TSV Processing and Wafer Stacking. Kathy Cook and Maggie Zoberbier, 3D Business Development

Equipment of machinery for contract manufacturing

dilatometry ΔL ΔT α = 1 ( )

A New MEMS-Based System for Ultra-High-Resolution Imaging at Elevated Temperatures

Graphite Foam for Cooling of Automotive Power Electronics

MODEL NanoMill TEM Specimen Preparation System. Ultra-low-energy, inert-gas ion source. Concentrated ion beam with scanning capabilities

LCR 7000 Series Capillary Rheometers. Single Bore LCR 7000 Dual Bore LCR 7002

Supporting Online Materials

Compact hybrid plasmonic-si waveguide structures utilizing Albanova E-beam lithography system

High-Temperature-Resistant Interconnections Formed by Using Nickel Micro-plating and Ni Nano-particles for Power Devices

Ceramic Processing Research

Power Vision Ltd. PV Research. Power Vision Ltd. Unit R2, Herald Park, Crewe, Cheshire, CW1 6EA, UK Tel:

Supplementary Figure 1 Heating E-chip. (A) The preparation of heating E-chip with

Transcription:

FUSION IN SITU HEATING AND ELECTRICAL Protochips Quantifiably Better

PtCo Nanoparticle 700 C Image courtesy Oak Ridge National Lab Fullerene STUDY MATERIALS 1200 C Image courtesy CIC nanogune WITH THERMAL AND ELECTRICAL AuAg Nanoparticles EDS, 400 C Image courtesy University of Manchester CHARACTERIZATION Ferroelectric Nanoparticles 700 C Correlate your results with TEM & SEM imaging Image courtesy Dr. Matias Acosta 0 V +3 V 3nm E +20 V 7nm E and analysis tools Au on Ti EBSD Image courtesy JEOL USA ZnO/Al 2 O 3 Fibers 750 C Image courtesy Dr. Hessam Ghassemi

WATCH DYNAMIC CHANGES 600 ºC 700 ºC >99.5% uniformity Au on Fe 2 O 3 600 C 700 C Image courtesy Oak Ridge National Lab ACHIEVE HIGH RESOLUTION >95% accuracy SETTLES FAST with minimal displacement ACCURACY & UNIFORMITY everywhere you image Fusion combines a new low-power E-chip technology with holders constructed using special alloys to dissipate heat. The result is minimal displacement and drift during heating experiments. With only nanometers of displacement during changes of hundreds of degrees, easily follow your area of interest even at the highest magnifications when heating and quenching your sample. Temperature accuracy starts with thermal uniformity. A non-uniform heating surface is not at a single temperature, therefore knowing the precise temperature of your sample is nearly impossible. Fusion s proprietary ceramic heating technology integrates the heater and the sample support area into a single thin film with temperature uniformity better than 99.5%.

Current (na) 8 4 0 0 8 16 Voltage (V) Sample Resistance (k Ω) 30 15 0 0 400 800 Temperature (ºC) ELECTRICAL characterization ELECTROTHERMAL characterization The fundamental challenge facing electrical experiments in the TEM or SEM is the very low current required to characterize nanoscale samples. These currents are often less than a nanoamp and must be precisely sourced and measured on a low-parasitic sample support to ensure accurate results. Fusion is a fully featured system that provides single digit picoamp measurements with sensitivity into the attoamps. With over 30 different electrical E- chip variations, there is a sample support for every application. Until now, it has been impossible to observe and measure electrical properties as a function of temperature inside an electron microscope. Electrothermal E- chips feature a silicon carbide heater with tungsten electrodes that enable researchers to perform these experiments even at high temperatures. The electrothermal function combines the full features and specifications of the Fusion heating and electrical modes into a single easy-touse software interface.

ATTACH FIB LAMELLA for thermal & electrical characterization in SEM or TEM Semiconductor FIB lamella on E-chip EDS MAP material transformations ELIMINATE CHARGING on insulating materials by applying temperature Room Temperature Limestone heated to 1000 C then quenched 100 ºC 900 ºC Mesoporous Silica (insulator) EBSD phase transformation and recrystallization Thermal grain growth of gold 650 ºC 25 ºC HEAT & QUENCH up to 70 microns in size Molten solder - 20 micron diameter SOFTWARE CONTROL with image synchronization SEM thermal & electrical characterization Control your experiments with powerful, intuitive Clarity software. Program electrical and/or thermal stimuli as waveforms or change parameters as you go. Observe data in real time with a visual user interface that plots your results. Optional Reflect software synchronizes images and video with the heating and electrical data, so analyzing your results is fast and easy. The same E-chip supports for the TEM can be used in an SEM with the Fusion SEM holder. Correlative experiments in the SEM enable analysis of morphology and composition using SE and BSE analysis. Together, the SEM and TEM are the perfect combination to analyze samples and correlate data to form a complete picture of material properties.

EDS ANALYSIS EDS analysis is fundamental to in situ materials research. By collaborating closely with the microscope manufacturers, all Fusion holders are optimized to maximize the collection of EDS signals, even at zero alpha tilt. Pd on TiO 2 EDS, 500 ºC: Image courtesy Argonne National Lab TEM PRODUCTS THAT ARE SAFE AND COMPATIBLE WITH YOUR MICROSCOPE DOUBLE TILT Smooth alpha and beta tilting and variable-speed finger touch controls enable precise, stable holder positioning. The E-Chip and the electrical contacts tilt together during beta tilt, providing excellent mechanical and electrical stability, while touch detection controls ensure microscope safety. Carefully evaluated and approved by your instrument manufacturer

140 Over 140 scientific peerreviewed journal articles 150 Over 150 heating systems in the market The Protochips system was integral to the success of the experiments. Repeatable image stability during heating with minimal sample drift allowed reliable acquisition of electron holograms. The steady heating and cooling rates enabled consistent repeatable experiments, which otherwise would have influenced the thermomagnetic behavior. 1300 Over 1300 citations - Dr. Trevor Almeida, University of Glasgow Our in situ work required a very stable double-tilt heating system to obtain atomic resolution of on-axis images while applying temperature changes to the sample. Without the Protochips heating system, our results would not have been possible. - Dr. James LeBeau, North Carolina State University For the first time I can now simultaneously heat and apply an electric field to my sample within the electron microscope. With this system I can observe the dynamic processes and mechanisms of field assisted sintering as they occur. - Dr. Klaus Van Bentham, University of California, Davis

ONE SYSTEM, ENDLESS POSSIBILITIES Microscopes Compatibility Alpha Tilt Beta Tilt (Option) Microscopes Compatibility Loading FUSION SPECIFICATIONS TEM HOLDERS Most Manufacturers and Models EDS, EELS, STEM, Diffraction, ETEM, Raman, Holography Up to ± 55 (varies by model) ± 10 SEM HOLDERS Most Manufacturers and Models SE, BSE, EDS, EBSD, STEM, Raman Load Lock & Direct Mounting Max Temperature* Temperature Uniformity Temperature Accuracy Temp Stability Heating & Cooling Rate Low Displacement Sample Supports Max Resolution Ultimate Drift Rate Interchangeable E-Chips Max Current Max Voltage Max Electric Field AC E-Chip Configurations E-Chips Current Measurement Accuracy Voltage Measurement Accuracy HEATING 1200 C (900 C for Electrothermal) > 99.5% > 95% < 0.01 ºC Any rate up to 1000 ºC/ms 7 nm at 5 seconds with 325 C ΔT Through Hole - Silicon Nitride - Holey Carbon 0.6 Å 0.5 nm/minute Interchangeable E-chips Between all TEM and SEM holders ELECTRICAL 100 ma 55 V, inquire for higher Up to 100 kv/cm Low Frequency 30 Interchangeable E-chips Between all TEM and SEM holders ± 0.15% + 750 fa ± 0.015% + 225 μv

Protochips Quantifiably Better Protochips www.protochips.com 3800 Gateway Centre Blvd Suite 306 Morrisville, NC 27560 Toll-Free Phone (USA/Canada): 844.INSITU1 (844.467.4881) International Phone: 001.919.377.0800 Fax: 919.377.0899 SF-00001 1.5 - English