SECTION FLAGPOLES. 1.1 SUMMARY A. Section Includes: 1. Fixed high dimensional, ground set, uniform conical taper, seamless tube flag pole.

Attachment A-Flagpole(s) Specifications

MCINTOSH COUNTY SCHOOLS TODD GRANT (K-5) SCHOOL DEMOLITION AND FINISHED SITE WORK

SECTION ROOF SPECIALTIES

D I V I S I O N 10: S P E C I A L T I E S

SECTION DECORATIVE METAL FENCES AND GATES

SECTION ROOF ACCESSORIES

SECTION COMPOSITE METAL DECKING

SECTION STRUCTURAL STEEL FRAMING

American Metal Specialties, Inc.

SECTION MISCELLANEOUS METALS

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION ACCORDION FOLDING PARTITIONS

SECTION COPPER STANDING SEAM ROOFING

SECTION ROOFING AND SIDING PANELS

SECTION DECORATIVE METAL RAILINGS

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

MODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications

SECTION STEEL JOIST FRAMING

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

SECTION COILING COUNTER DOORS

SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.

SECTION ALUMINUM STORM WINDOWS

SECTION OVERHEAD COILING SHUTTERS

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ORNAMENTAL ALUMINUM RAILING

UNIFIED FACILITIES GUIDE SPECIFICATIONS

05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES

SECTION ALUMINUM HANDRAIL SYSTEMS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

SECTION WALL AND DOOR PROTECTION

SECTION SHOWER AND DRESSING COMPARTMENTS

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION TURBINE VENTILATORS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION FACILITY LIGHTNING PROTECTION

SECTION METAL STAIRS

SECTION TOILET COMPARTMENTS

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SHORING & UNDERPINNING 02250

MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.


SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

A. American Society for Testing and Materials (ASTM):

Aluminum Component Pipe Railings

SECTION GYPSUM BOARD

SECTION COMPOSITE METAL DECKING

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

SECTION LOUVERS AND VENTS

METAL HANDRAILS AND RAILINGS. A. Properly identified manufacturer's literature, including shop and erection drawings before starting work.

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

SECTION RESILIENT TILE FLOORING

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.

SECTION CHAIN LINK FENCES AND GATES

SECTION MECHANICAL EQUIPMENT - GENERAL REQUIREMENTS

SECTION ALUMINUM STORM WINDOWS

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

SECTION STANDING SEAM METAL ROOFING

SECTION CHAIN LINK FENCES AND GATES

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION VISUAL DISPLAY SURFACES

A. The extent of extruded aluminum walkway covers is shown on the Drawings and as specified herein.

Product Guide Specification

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

TRICON DOUBLE-CON PLUS

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION ORCHESTRA PIT FILLER

SECTION METAL FABRICATIONS

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2015 EDITION

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR SPUN CONCRETE POLE AND DRILLED SHAFT FOUNDATION

SECTION TERRAZZO FLOOR TILE

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION STORM DRAINAGE

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION DIRECTORIES

Division 11 - Equipment Section 11401

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

DIVISION 2 - SITE WORK

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

SECTION PASS WINDOWS. 1.1 SUMMARY A. Section Includes: 1. Factory finished sliding glass, counter mounted pass windows.

SECTION ORNAMENTAL WELDED STEEL FENCING

Aluminum Perforated Rolling Door

STRUCTURAL STEEL FRAMING

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

Work Order Number *************************************************************************** SECTION C20 STAIRS 02/18

SECTION ACOUSTICAL CEILINGS

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

PIPE CULVERTS. Construct pipe culverts, beveled ends, pipe aprons, and associated appurtenances.

SECTION ALUMINUM GATES

SECTION FIRE HYDRANTS

SECTION RESILIENT SHEET FLOORING

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS

SECTION MISCELLANEOUS METALS THIS SECTION TO BE INCLUDED IN SUB BID FOR SECTION MISCELLANEOUS AND ORNAMENTAL IRON

Transcription:

PART 1 - GENERAL 1.1 DESCRIPTION SECTION 10 75 00 SPEC WRITER NOTE: 1. Use this section only for NCA projects. 2. Delete between //----// if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. A. This section specifies materials, shipping and delivery protection, storage, handling, and installation of flagpoles to be installed in the project area indicated. Flagpoles shall be deluxe internal halyard fixed high dimensional, ground set, cone tapered, seamless tube flag poles together with concealed halyard, revolving truck, finial ball, flashing collar, anchors, fittings, and accessories. 1.2 RELATED WORK A. Excavation and backfill: Section 31 20 00, EARTH MOVING. B. Concrete for ground set flagpole: Section 03 30 53, (SHORT FORM) CAST- IN-PLACE CONCRETE. 1.3 SUSTAINABILITY REQUIREMENTS A. Materials in this section may contribute towards contract compliance with sustainability requirements. See Section 01 81 11, SUSTAINABLE DESIGN REQUIRMENTS, for project // local/regional materials, // lowemitting materials, // recycled content, // certified wood // // requirements. B. Biobased Material: For products designated by the USDA s BioPreferred program, provide products that meet or exceed USDA recommendations for biobased content, subject to the products compliance with performance requirements in this Section. For more information regarding the product categories covered by the BioPreferred program, visit http://www.biopreferred.gov. 1.4 SUBMITTALS A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Shop Drawings: Flagpole details of all parts & accessories, and list of all materials, including but not limited to: base with support plate and grounding spike, lightning kit, pole, flash collar, revolving 10 75 00-1

truck, internal halyard, cable assembly, winch detail w/lock, hooks, beaded retainer ring, counterweight, winch handle and finial ball, along with construction and installation details. Flagpole components shall match those for the main pole. C. Manufacturer's Literature and Data: Flagpole, base and all parts and accessories. 1.5 APPLICABLE PUBLICATIONS A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by the basic designation only. Comply with applicable provisions and recommendations of the following, except as otherwise shown or specified. B. American Society for Testing and Materials (ASTM): SPEC WRITER NOTES: 1. Remove reference citations that do not remain in Part 2 or Part 3 of edited specification. 2. Verify and make dates indicated for remaining citations the most current at date of submittal; determine changes from date indicated on the TIL download of the section and modify requirements impacted by the changes. A167-99 (R2009) Stainless and Heat-resisting Chromium-Nickel Steel Plate, Sheet and Strip B209-10 Aluminum and Aluminum Alloy-Sheet and Plate B241/B241M-12 Aluminum and Aluminum-Alloy Seamless Pipe and Seamless Extruded Tube C. American National Standards Institute Inc. (ANSI): ANSI/NAAMM 1001-97 1.6 QUALITY ASSURANCE Guide Specifications for Design of Metal Flagpoles Manual. A. Manufacturer s Qualifications: Firms regularly engaged in the manufacture of metal flagpoles and accessories, of types, size and configurations required, whose products have been is satisfactory use in similar service for not less than 5 years. B. Installer s Qualifications: Firm with at least 3 years of successful installation experience on projects having flagpole installation work similar to that required for this project. SPEC WRITER NOTE: 1. Modify the following paragraph to describe the various flagpoles for this project. Provide the size, wind 10 75 00-2

speeds, flag size and wall thickness for each flagpole size to be provided. Wind speed shall be the minimum specified in the wind speed chart for the project location. 2. Modify these specifications and coordinate with the drawings, details and notes to ensure that the flagpole foundation has been sized according to the applicable wind load conditions for the respective flags and poles, and that the foundation design has been performed by a qualified structural engineer, based upon the soil conditions, and installation method for the flagpole. 3. The spec writer shall ensure that the design A/E has had a professional engineer do the foundation design and specify all of the size, reinforcing, and installation parameters. The drawings and specifications should be modified and coordinated to reflect the designed foundation parameters. C. Design Criteria: Flagpole shall be designed to withstand the wind speeds and conditions indicated herein for the specific flagpole and flag sizes indicated. The //7.6 m//(//25// foot) flag pole shall be designed based upon a minimum sustained 160 kmph (//100// mph) wind velocity and minimum wind gust velocity of 210 kmph (//130// mph) when flying a flag 1.5m x 6.5m (//5 x 8 //) in size in accordance with ANSI/NAAMM 1001-97, with the pole wall thickness being in conformance with the design standards but with a minimum wall thickness of 5mm (//0.188// inches), whichever causes the stronger flagpole. The flagpole foundation(s) has/have been designed based upon applicable conditions for the project specific location of the respective flagpole. 1.7 PROTECTION AND SHIPPING A. Package flagpole for shipping with spiral wrap protective covering and pack in shipping tubes acceptable to owner s designated representative and per manufacturer s recommendations. PART 2 - PRODUCTS SPEC WRITER NOTE: 1. Make material requirements agree with applicable requirements specified in the referenced Applicable Publications. Update and specify only that which applies to the project. 10 75 00-3

2.1 MATERIALS A. Aluminum, Extruded: ASTM B241, alloy 6063 - T6. B. Aluminum, Plate and Sheet: ASTM B209, alloy ll00. C. Stainless Steel: ASTM A167, Class 302 or 304. 2.2 FABRICATION A. Fabricate flagpole of seamless extruded aluminum tube, uniform conical taper of approximately 1 in 70, one centimeter in seventy centimeters (one inch in every 6 feet). Taper shall not exceed 50 percent of outside diameter of pole. When flagpoles are shipped in more than one section, provide self-aligning sleeves for field joint. B. Base: Aluminum plate or stainless steel, of stock design similar to that shown. C. Finial Ball: 2 mm (0.0747 inch) thick spun aluminum sphere, with seams of ball welded flush and watertight. Mount ball on threaded rod to fit truck. Diameter of ball shall be approximately same as pole butt diameter. D. Truck: Equip pole with extra heavy, revolving, non-fouling, ball bearing type truck with cast aluminum body and designed to accept an ornament on top. E. Halyards: Internal type cable assemblies. 3 mm (1/8 ) and/or 5 mm (3/16 ) stainless steel aircraft cable incorporating a stainless steel swivel, upper cable section, and flag arrangement with cable and two stainless steel quick links and two stainless steel swivel snaps. The cable assemblies shall be constructed to fit the flagpole size and flag size specified. F. Beaded Retainer Ring and Counterweights: Provide as recommended by manufacturer based on the pole size, flag size and design wind velocity. Provide recommended connection accessories. G. Internal Halyard Accessories: Furnish and install a gearless, selflocking at any point, direct drive winch that does not require welding for installation and does not require monthly application of lubrication and is attached to the pole with one stainless steel bolt on the back side of the pole. The unit shall be silver in color. Provide locking mechanism and two keys. Provide a winch handle designed for the unit. Pole shall be reinforced through the area of the winch opening by the manufacturer s standard reinforcement method. H. Foundation Tube: Hot dipped galvanized corrugated steel tube. Tube shall have a steel base plate and centering wedges and support plate 10 75 00-4

for connection of lightening kit. Bottom plate shall be a minimum of 5 mm (3/16 ) thickness. SPEC WRITER NOTES: 1. Unless specifically directed otherwise by the PM, all of the flagpoles shall be designed and installed with the Manufacture's best lightening kit system. I. Lightning Kit: Provide a complete kit (maximum protection available) 2.3 FINISH for each pole. Configuration and components for the kit shall be as recommended by the pole manufacturer for use on the pole selected. A. Finish exposed surfaces of flagpoles. B. Flagpole shaft: Satin brushed aluminum, then heavily waxed. C. Finial ball: Gold anodized aluminum, then heavily waxed. D. Base// and cleats//: Finish to match flagpole. //E. Stainless Steel (base): As recommended by flagpole manufacturer.// PART 3 - EXECUTION 3.1 INSPECTION A. Verify that concrete foundation work is correctly sized and positioned. B. Repair or replace defective foundation work as directed by owner s designated representative. 3.2 PREPARATION A. Coat portions of flagpole below grade and in surfaces in contact with dissimilar metals with black asphaltum paint, as recommended by manufacturer. 3.3 INSTALLATION A. Install galvanized, corrugated steel sleeve or tube of detailed length, welded to steel base plates for installation in concrete. Set base plate and Lightning Kit in place before concrete is placed. Follow the manufacturer's recommendations for the installation of the lightning kits. B. Install foundation plate and centering wedges for flagpole base in concrete base and fasten. C. Install concrete foundation work to dimensions indicated in accordance with Section 033053, SHORT FORM CAST-IN-PLACE CONCRETE. D. Wrap top of sleeve with two layers of asphalt felt for distance of 600 mm (2 feet) down. E. Install flagpole in accordance with manufacturers written installation instructions. Install pole plumb using centering wedges. 10 75 00-5

F. Backfill and compact excavation around flagpole base in accordance with Section 312000, EARTH MOVING. G. Fill and thoroughly compact dry fine sand into the space between pole and steel sleeve and tamp to within 50 mm (2 inches) of top of sleeve. H. Remove temporary wood positioning wedges and fill upper 50 mm (2 inch) space between pole and steel sleeve with specified or manufacturer recommended waterproofing compound. I. Install fittings in accordance with manufacturer s written installation instructions. J. Check and adjust installed fittings for smooth operation of halyards. 3.2 LIGHTNING ROD A. Weld lightning ground rod of 19 mm (3/4-inch) diameter galvanized steel to base plate at bottom of sleeve or tube, and to steel support plate at grade. 3.3 CLEANUP A. After installation, carefully clean the flagpole and appurtenances, removing all dirt stains, and all other incident defacements. 1. Fabricator should be contacted regarding the use of any cleaners and must approve of them before use. 2. Protection of Finished Work: Flagpoles for this project shall be protected at all times during construction. B. Clean up area of excess material and debris. - - - E N D - - - 10 75 00-6