W all, Ceiling & Laminated Liner Panels

Similar documents
WALL & CEILING LINER PANELS

Wall, Ceiling & Laminated Liner Panels

WALL & CEILING LINER PANELS

Headquarters & Distribution Centers. Manufacturing Facilities Warehouse Locations

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels

Impression Graphic panels

Rev. 07 8/15 Please Read Disclaimers:

Rev. 08 9/15 Please Read Disclaimers:

Nudo Guide Specification 03/01/2016 FiberScore FRP Wall Panels SECTION FIBERSCORE FIBERGLASS REINFORCED WALL PANELS

FiberLite FRP. Technical Data. Class C - Pages 1-2 Class A - Pages 3-4

Decorative Fiberglass Reinforced Wall Panels

Caution: Protect eyes with goggles and cover mouth with filter mask when cutting panels.

Durable & Decorative Wall Panel Solutions

Proudly Made in the U.S.A. 5-Year Warranty. Wayfinding Products

SECTION FLAT WALK-ON TYPE ALGAE CONTROL/LAUNDER COVERS

Skylight & Sidelight Panels

Insulation. First Revison October DC14 Drainage Mat INSTALLATION GUIDE FOR RESIDENTIAL & COMMERCIAL APPLICATIONS

Technical Data Sheet

WEIGHT PER PIECE (LBS.)

ENGINEERING SPECIFICATION NON-MAGNETIC RAISED FLOOR SYSTEM FOR MRI ROOM APPLICATIONS

SECTION DETECTABLE GUIDE TACTILES

ENGINEERED WATERPROOF FLOORING GENERAL INSTALLATION INSTRUCTIONS FOR VÄLINGE 2G LOCKING FLOORING

Installation Instructions. Important. Recommended Tools. Palladium Rigid Sheet/Rubrail or Palladium G2 Sheet/Rubrail. Storage

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

Section Special Wall Surfacing

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR DROP LOCK FLOORING

ProGUARD Guide Specification

ENGINEERING SPECIFICATION

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,

Gold Bond BRAND Gypsum Sheathing

LOOSE LAY INSTALLATION GUIDE PAGE 1 of 6

ENGINEERED LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

Proudly Made in the U.S.A. 5-Year Warranty. Wayfinding Products

SECTION SOLID SURFACE FABRICATIONS

INDOOR RUBBER FLOORING INTERLOCKING INSTALLATION / MAINTENANCE GUIDELINES MARATHON SERIES. Four-Side Interlock Loose Lay Installation

ADDENDUM NO. 1. Bidders are hereby informed that the Construction Plans and/or Specifications are modified as follows:

Installation Guide LVP Glue Down

INSTALLATION INFORMATION

ENGINEERING SPECIFICATION. PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC. October 25, 2004 Revision 1

Install & Maintenance Instructions

3 500-Series Polyurethane Products:

ENGINEERING SPECIFICATION PULTRUDED FIBERGLASS GRATING SAFE-T-SPAN HIGH LOAD CAPACITY (47% OPEN AREA) VINYL ESTER. January 24,

1.02 DESCRIPTION A. This Section specifies furnishing and installing Surface Applied Detectable/Tactile Warning Surface Tiles where indicated.

INSTALLATION INSTRUCTIONS

LVP GLUE DOWN INSTALLATION GUIDE PAGE 1 of 6

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

SECTION RESILIENT SHEET FLOORING

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

CSI GUIDE Countertops

ENGINEERING SPECIFICATION FIBERTRED MOLDED STAIR TREADS SECTION 06610

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

INSTALLATION GUIDE. wall, ceiling and laminated panel installation GLASBORD DESIGNS VARIETEX KEMPLY

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

BioPrism Solid Surface

Genesis Panel Systems LLC Dura-Max Brick Panel Siding Installation Instructions

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

Product Guide Specification

The purpose of this guide specification is to assist the specifier in correctly specifying solid surface countertops including sinks and backsplashes.

DURAMAX Building Products a division of US Polymers Inc. July S Vail Ave Montebello, CA., Toll Free Phone Fax Website

Powerdek Fleck. SECTION Resilient Athletic Flooring

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Surface Mount Tactile

The use of wood putty, wood filler and wood stain for enhancement of the flooring should be accepted as normal.

ENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL

SECTION FRP GRATING, HANDRAIL, AND SUPPORTS

Install Instructions. Acrovyn 4000 Wall Covering. For.040 and.060 Acrovyn Sheet

Installation Guidelines: Magnolia

Armstrong Flooring Installation Accessories

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

INSTALLATION GUIDE for Cleanroom Wall Panels

1. What are the benefits of Decorative Wall Panels? 2. Where can these decorative panels are used? 3. Are the panels waterproof?

Resysta Wall Cladding Installation Guidelines

COREGUARD FORCED ENTRY RESISTANT SECURITY WALL PANELS ARCHITECTURAL INSTALLATION SPECIFICATION PART 1 GENERAL 1.1 REFERENCE

ENGINEERING SPECIFICATION FIBERGRATE 1 INCH DEEP MICRO-MESH MOLDED GRATING SECTION 06610

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

POLYACRYLATE MODIFIED THINSET TERRAZZO 1

Thermasheath-XP. Insulation for Exposed Use

Gold Bond BRAND Kal-Kore Plaster Base

SECTION POLYPROPYLENE FABRIC WALL COVERING

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

1 PVC or ABS drain with strainer

Foil Back Gypsum Board

Styled & Durable. surface systems INSTALLATION GUIDE. wall, ceiling and laminated panel installation GLASBORD DESIGNS VARIETEX KEMPLY

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING

ENGINEERING SPECIFICATION PULTRUDED DYNADECK INTERLOCKING FLOORING

FIBERGLASS REINFORCED PLASTIC (FRP) LAUNDER COVERS

LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR LOCKING FLOORING

Section QUARTZ SURFACING COUNTERTOPS

13340 FIBERGLASS REINFORCED PLASTIC (FRP) ENCLOSURE

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

APPLICATION INSTRUCTIONS REALSIDE TM

Call For Your Local Distributor of Nu-Poly Mezzanine Decking

ENGINEERING SPECIFICATION FIBERGRATE 62% OPEN AREA/ADA COMPLIANT MOLDED GRATING. January 5,

Triton DCI Decoupling Mat

SECTION DETECTABLE/TACTILE WARNING SURFACES

IVC US. Light Commercial Installation Guide - Sheet Vinyl. Leading the Way

Transcription:

W all, Ceiling & Laminated Liner Panels

Improved Chemical Resistance Resists stains Rust proof - will not corrode Minimum maintenance and never needs painting Superior Flexibility Panels are flexible enough to lay flat, allowing a better fit into areas with close tolerance seams Custom Designed Liner Panels Available in 5 different standard panel thicknesses Shipped in standard 4 foot width and in 8, 9, 10 and 12 foot lengths Wall Panel Specifications Glasliner FRP is available in the following sizes: Series Nominal Thickness 1600.125 1200.090 180.060 160.045 150.035 Width Standard 4 Feet Length 8, 9, 10 and 12 Feet Low Cost Installation Easy to handle and install in any type of construction, and over any type of existing wall surface No special tools needed More economical than stainless steel or ceramic tile

Approvals & Certifications ISO 9002: All Glasteel plants are ISO 9002 Certified Meets USDA/FSIS requirements Canadian Food Inspection Agency (CFIA) accepted ICC: Report # ER-2364 : All Glasliner FRP liner panels are manufactured according to industry standard D-3841-2001 FM Approvals: All Glasliner FRP liner panels are tested and listed by FM Approvals Typical Physical Properties for.090 Contractor Grade Property Test Method Unit Glasteel Class C General Purpose Result Glasteel Class A Fire Retardant Result Storage Recommendations Store panels indoors in a cool, dry, well-ventilated area Panels should be stacked on skids not more than 5 skids high Do not allow moisture to collect on or in-between panels Flexural Strength Flexural Modulus Tensile Strength Tensile Modulus % Elongation Water Absorption 21 C @ 72 hrs. Izod Impact Strength Coef. of Linear Thermal Expansion Barcol Hardness D-790 PSI 17,000 10,000 D-790 PSI 6.0 x 10 5 3.1 x 10 5 D-638 D-638 D-638 D-570 D-256 D-696 D-2583 PSI 8,000 7,000 PSI 9.43 x 10 5 3.1 x 10 5 % 1.20 1.80 % 0.17 0.72 ft.-lbs. /in. 7.0 7.16 in./in. / F 2.22 x 10-5 2.39 x 10-5 Avg. 30 35 Specific Gravity D-792 N/A 1.6138 1.5743 Abrasion Resistance TABER % WT Loss 0.293 0.391 Flash Ignition Temp. Self Ignition Temp. Flame Spread Smoke Generation 1929 C 430 400 C 1929 450 430 E-84 E-84 N/A N/A 200 25 <450 <450

Color Selections Installation Instructions Bright White Beige Almond Ivory Safety: Use eye protection. Wear filter mask to cover nose and mouth, especially when cutting. Use manufacturer s recommended sealants and adhesives. Tools Needed: Power or hand saw (fine tooth or carbide blade) Power or hand drill (carbide tip recommended) Carpenter s square Hammer, tape measure and level Adhesive and notched trowel Silicone sealant and caulking gun Vinyl moldings and 3/4 nylon fasteners Silver Black Light Gray Preparation: It is important to store Glasliner FRP flat, on a clean, dry surface for 24 hours before installation. It is preferable to store them inside the actual area of installation or, at least, under similar climate conditions. Walls must be clean and free of all substances. Level any high or low spots on walls. Concrete block walls may require a leveling coat of plaster or other similar material. Two Surface Finishes Traditional pebbled finish Premium Gel Coat Installation of FRP Laminated Panels, in any application, should be approved by local building code officials before panels are ordered. Glasteel cannot ensure local code compliance in any or all situations. NOTICE: Panels and components made of fiberglass (FRP), wood, vinyl or foam may be combustible. DISCLAIMER and LIMITATION of Liability: The information contained in this literature is presented in good faith, and is believed to be accurate and reliable at time of publication. No representation, guarantee or warranty is made as to the completeness, reliability or accuracy of this information.this also includes NO IMPLIED WARRANTY OR MERCHANTABILITY OR FUNCTIONAL USE FOR SPECIFIC APPLICATION.

Accessories Cutting Glasliner FRP for Floor to Ceiling Heights of 8 Feet or Less: Subtract 1/2 from height measurement to allow for expansion. Allow for 1/8 expansion gap around pipes and other projections. Inside Corner End Cap Divider Bar Drilling Fastener Holes: Pre-drill fastener holes before applying adhesive. Fastener holes should be slightly oversize to allow for normal expansion and contraction. Drill holes no further than 8 apart and 1 from outside edge, 16 apart on intermediate and on 16 centers. Outside Corner Outside Corner Angle Nylon Rivets Installation reminders: 1. Follow safety and fire guidelines during installation and use of panels. 2. First panel installed should be set true with plumb line. 3. Wall must be clean and flat. 4. Use moldings, silicone, nylon rivets and adhesive for best installation. 5. Apply adhesive. 6. Install panels and moldings. 7. Seal edges and moldings. 8. Remove excess silicone. 9. Clean panels after installation with light detergent. Applying Adhesive FRP Adhesive For best installation, combine adhesive and nylon fasteners. Glasliner FRP should never be installed on uneven walls using only adhesive. Apply adhesive to panel, not wall, using 100% coverage with notched trowel. Actual requirements may vary. Call Glasteel for complete installation instructions.

Laminated Panels Why use Laminated FRP panels? Ease of installation Reduced labor costs Durable Sanitary Easily Maintained Ideal for: Agricultural buildings Kitchens Fast food restaurants Restrooms Storage areas Laboratories Food processing plants Health care facilities Convenience stores Kennels and veterinary clinics Walk-in coolers and freezers Moldings 3/8 Cap (.460 opening) 3/8 Divider (.460 opening) 3/8 ISC/Cove (.460 opening) 3/8 OSC (.460 opening) FRP Panels are laminated to: Plywood OSB 1-1/2 OSC Angle 1-1/2 ISC Angle 2-Piece Divider Laminated Panel Specifications Sizes 4 x 8 and 4 x 10 Substrate Thickness 3/8 standard Color Bright White For other substrates, colors or sizes, please contact Glasteel.

Installation Instructions and Guidelines for Glasliner FRP Panels Read all instructions before installation. Glasliner FRP panels should only be installed over solid wall surfaces (standard drywall, standard plywood, standard OSB, cement board, cement, etc.) Consult your adhesive manufacturer for recommendations for non-standard substrates. Inspection, Storage, and Preparation Panels should be inspected in a well lit area promptly upon receipt to ensure material suitability. Do not store panels outdoors. Panels should only be stored in a dry area. Promptly unwrap and remove panels from skid and stack on a flat, dry surface. Ensure that the climate of the room, the panels, and the adhesive are all above 50 F before and during installation. Avoid large temperature changes for at least 24 hours after installation is complete. Normal fire-safety precautions should be taken during storage and installation of panels. Panels are inspected for defects prior to shipment, and should be re-inspected by the installer prior to installation. If panels are not acceptable, contact Glasteel customer service prior to installation. Glasteel is not responsible for installation or removal costs of unacceptable panels. Tools Panels can be cut using power saws with a fine carbide tip blade or masonry blade. Panels may be drilled for fastening with a metal drill bit. Masonry bits are recommended when drilling in concrete. Caution: Protect eyes with goggles and cover mouth with a filter mask when cutting Glasliner panels. Use a trowel recommended by the adhesive manufacturer to apply adhesive to the back side of the panel. A laminate roller is recommended to remove air pockets and ensure adhesion of the surface area. Adhesives & Fasteners The use of a specifically formulated FRP adhesive is recommended when installing Glasliner FRP panels. Follow the adhesive manufacturer s instructions carefully. Many adhesives are flammable and some may not be compatible with paneling. Glasliner FRP panels may be successfully installed using only adhesive on typical even surfaces. Installation over uneven surfaces using adhesive only may cause adhesion failure. Mechanical fasteners may be used in certain non-typical applications. If mechanical fasteners are used, they should be non-corroding (i.e. plastic pin rivets, chrome pin rivets, one piece nylon rivets, and stainless screws, etc.). Follow the fastener manufacturer s instructions carefully.

Moldings Cap Divider Bar Outside Corner Inside Corner Preparation of Substrate Ensure that the substrate is flat with even surfaces. High and low areas should be leveled prior to installation. Remove any foreign material or debris that could interfere with proper bonding of the adhesive. (Caution: Installation over uneven surfaces could result in adhesive failure, resulting in de-lamination of the panel.) Non-Porous Surfaces: Non-porous surfaces are not a favorable surface for adhesive to bond, as most adhesives will not dry properly. Consult adhesive manufacturer for specific recommendations. Examples: Metal Panels, Ceramic Tiles, Glazed Block, other Moisture Resistant Substrates New Gypsum Board: A finish coat is not recommended. Using a setting compound, joints need only a fill and taped coating. Plywood: Warped Plywood should be removed and replaced with plywood that is flat and even. Consult adhesive manufacturer on any installation over pressure treated or fire-rated plywood. Concrete Block and Brick: Concrete block and brick walls are typically uneven. It is recommended that furring strips be applied to the concrete block or brick walls and a suitable substrate be installed over the furring strips. Panels may then be installed to the substrate according to installation instructions. ( An alternative to this are Glasteel s Laminated FRP Panels.) If the installer decides to install panels directly to concrete block walls, it is recommended that the panels be installed with mechanical fasteners. Drill oversize holes in panel and allow more room at expansion joints. This way panels will be able to expand and contract around the attachment device and lessen (but not eliminate) buckles in the panels. Consult adhesive manufacturer for recommended adhesive when installing directly to concrete block or brick walls. Painted Surfaces: Painted surfaces must be abraded or gouged with a heavy grit sand paper to break the barrier of the paint. Painted surfaces will not allow most adhesives to dry properly. All loose paint and debris must be removed prior to installation. Environmental Considerations Service Temperature: The service temperature range for Glasliner FRP is 0 F to 130 F. Near a Heat Source: Panels may discolor when installed in proximity to a heat source. Glasteel does not recommend that panels be installed near a heat source that radiates temperatures greater than 130 F (55 C). Examples of heat sources include cookers, ovens, and deep fryers. Stainless steel is recommended in these areas.

FRP Panel Installation Steps Step 1: Trim panel to fit and create over-sized pilot holes. Expansion Joint Recommendations installation of panels over 12 long is not recommended PANEL SIZE 4X8 4X9 4X10 4X12 Space around rivets 1/8 1/8 3/16 3/16 If using a power saw, ensure that the blade enters the front (finished ) side of the panel to avoid damage. Using Fasteners 1. When using rivets, panels should be predrilled allowing for the spacing in the above chart. Holes slightly larger than the fasteners should be drilled into the substrate through the pre-drilled holes in the panel. Do this prior to adhesive application. 1" 48" 15" 16" 15" p o n g q a h r 8" 8" 15" 16" 2. Apply a silicone sealant prior to inserting fasteners. s b i 3. Fasten panel first in the center and work outward. Fasteners should be used 16 on center vertically and horizontally. Fasteners on panel edges should be at least 1 to 1 1/2 from the panel edge when using one piece fasteners. Using two piece moldings, put perimeter holes 1 1/2 to 2 away from the panel edge. 96" t u v c d e j k l w f m Step 2: Cut out any fixture openings. Expansion Joint Recommendations installation of panels over 12 long is not recommended PANEL SIZE 4X8 4X9 4X10 4X12 Space between panels and wall fixtures 1/8 1/8 3/16 3/16 Step 3: Start at an inside corner of the room. Mark a plumb line 48 + expansion distance (see Step 5 chart) from the corner. The initial panel should be set true with plumb line. Step 4: Apply FRP adhesive to the back side of the panel using the adhesive manufacturer s recommendations. Failure to apply adhesive properly may cause de-lamination.

Step 5: Place panel on the wall, leaving space and the joints for expansion and contraction. Expansion Joint Recommendations installation of panels over 12 long is not recommended PANEL SIZE 4X8 4X9 4X10 4X12 Gap at ceiling 1/4 1/4 3/8 3/8 Gap at floor 1/4 1/4 3/8 3/8 Gap between panel and center of 1 piece molding 1/8 1/8 3/16 3/16 Gap between panel and center of 2 piece molding 1/4 1/4 3/8 3/8 Gap between panel not using molding 1/4 1/4 3/8 3/8 Failure to allow adequate molding spacing may cause delamination Incorrect Correct Divider Bar Step 6: Use of silicone sealant is recommended to achieve a moisture resistant installation. Place silicone sealant into the channel of cut-to-size moldings. Fit coordinating moldings between the joints leaving the recommendations in step 4 to allow for expansion and contraction. In high moisture and frequent wash-down areas, silicone should be used between moldings and floors/ceilings to prevent moisture from penetrating the back of the panel substrates. Step 7: Use a laminate roller to remove air pockets. Work from the middle of the panel out to the leading edge. Step 8: Repeat steps one through seven until project is complete. Step 9: Clean excess adhesive residue from surface of panels following adhesive manufacturer s recommendations. DISCLAIMER and LIMITATION of Liability: The information contained in this literature is presented in good faith, and is believed to be accurate and reliable at time of publication. No representation, guarantee or warranty is made as to the completeness, reliability or accuracy of this information. This also includes NO IMPLIED WARRANTY OR MERCHANTABILITY OR FUNCTIONAL USE FOR SPECIFIC APPLICATION. 285 Industrial Drive Moscow, TN 38057 Phone: (901) 877-3010 Fax: (901) 877-1388 www.glasteel.com