SUPERIOR FIRE RESISTANCE

Similar documents
AITC TECHNICAL NOTE 26 DESIGN VALUES FOR STRUCTURAL GLUED LAMINATED TIMBER IN EXISTING STRUCTURES December 2007

Fire Retardants and Truss Design. Overview

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

AITC Technical Note 7

Introduction. This Part One will address; Type 1 Fire Resistive and Type 2 Noncombustible buildings.

INTERIOR FINISHES CHAPTER 8

INTERIOR FINISHES CHAPTER 8 SECTION 801 GENERAL

Knowledge Objectives (3 of 3)

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

CHAPTER 6 TYPES OF CONSTRUCTION

INTERIOR FINISHES CHAPTER 8

Updated references to SEI/ASCE 7 to the 2016 edition once it is available.

2018 IBC Chapter 6 Types of Construction

Interior FRT Wood. References to ICC Building Codes

Uncompromising Quality and Service

AMERICAN INSTITUTE OF TIMBER CONSTRUCTION AITC

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

INTERIOR FINISHES CHAPTER 8

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

CITY SECTION 701A 702A. of this chapter. Protection

Fire Engineering, the BCA (NCC) & Bushfire Calculator. Keith Nicholls - Manager Product Testing and Assessments (Australia) Exova Group Limited

City of Bemidji Building Office City Hall 317 4th Street NW Bemidji, Minnesota Phone Fax emi mn s

RigidPly Rafters Inc.

Interior FRT Wood. References of Previous Model Building Codes

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 301

Use of Coatings to Improve Fire Resistance of Wood

WOOD I-JOIST AWARENESS GUIDE

Exposed Wood in Fire Resistive Applications

DECK PERMIT APPLICATION

City of Republic Community Development Girder and Header Spans for Exterior Walls

Title: Building Construction for the Fire Service. Time: 3 hours. Teaching Materials: White board Building Construction for the Fire Service (PDF)

General Building Information

TYPICAL BEARING WALL FRAMING

Fire Safety and Performance of Wood in Multi-Residential and Commercial Buildings. Boris Iskra Forest & Wood Products Australia

Fire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

FIGURE R502.2 FLOOR CONSTRUCTION

Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue Oroville, CA Office (530)

Technical Topics. Wood I-Joist Floors, Firefighters and Fire

UNDERSTANDING THE MASS TIMBER CODE PROPOSALS. A Guide for Building Officials

SECTION R327.3 STANDARDS OF QUALITY

Copyright Materials. Learning Objectives. Design is in the Details: Solutions to Common to Mid Rise Design. Challenges

American National Standard

Fire Resistive Design of Exposed Timber Structures

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Mid-Rise Engineering Considerations for Engineered Wood Products

Cross Laminated Timber (CLT)

Building Codes and Ordinances ARC 227

Changes to the 2005 NDS Supplement Design Values for Wood Construction

NEWS LETTER MARCH 27, 2009

assembly an open space between the roof and ceiling of a building attic balloon frame a joist constructed of steel with bars in the verticle web space

6-Storey Residential Buildings Combustible Construction. A Regulator s Perspective City of Richmond, BC Canada

UNIFIED FACILITIES GUIDE SPECIFICATIONS

International Building Code Essentials for Wood Construction

Analysis of Glulam Timber Beams with Mechanically Graded (E-rated) Outer Laminations

BUILDING CODE REQUIREMENTS

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 7 Ventilation Lightweight Construction Revised

Standardized 3-part specifications D-Blaze FRTW CSI 3-part and Canadian CSC architectural specs are available at

Outcomes of ICC Tall Wood Ad Hoc Committee: Proposals and Discussion

FIRE AND SMOKE PROTECTION FEATURES

SECTION 702 DEFINITIONS

Ad Hoc Committee Tall Wood Buildings IDENTIFICATION OF ISSUES (Updated June 22, 2016)

ANSI A Standard for Wood Products Structural Glued Laminated Tımber

Regulatory Frames IBC

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

FIRE RESISTANCE OF WOOD MEMBERS WITH DIRECTLY APPLIED PROTECTION

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED STRUCTURAL WOOD REPORT HOLDER: SWEET S JOISTS, INC.

Combustible Exterior Wall Cladding Systems: An ICC Perspective

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

Executive Summary. Proposal. 12/5/2002 Consultant: Dr. Boothby

Formulating a Korea Industrial Standard for light-frame wood construction

INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

BPVV R7002 Lumber, Treated

BAND SHELLS Our versatile Band Shells perform in any community

INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS

Flame Spread Performance of Wood Products Used for Interior Finish

Lock-Deck Laminated Decking

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

LVL Product Guide 2.0E LVL 1.5E LVL

First Revision No NFPA [ Section No ]

IAPMO UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR JOIST HANGERS AND MISCELLANEOUS CONNECTORS

Excerpts from the Uniform Building Code. (UBC) For The US

Jonathan Barnett Richard Gewain Ramon Gilsanz Harold Bud Nelson. 4WTC 4, 5, and 6

2005 ERRATA to the Edition of. the Allowable Stress Design (ASD) Manual for Engineered Wood Construction (printed version dated M)

Essentials of Fire Fighting

FIRE RATING AND FIRE PERFORMANCE

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

RESIDENTIAL BUILDING PLAN REQUIREMENTS

BUILDING CODE COMMISSION

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

HIGH PERFORMANCE FIRE RETARDANT TREATED WOOD PRODUCTS

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

WESTERN RED CEDAR PANELING & MOULDINGS

Slide 1. Slide 2. Slide 3. Lumber Standards and Specifications. Learning Objectives. Frank Stewart Western Wood Products Association

Transcription:

AMERICAN INSTITUTE OF TIMBER CONSTRUCTION SUPERIOR FIRE RESISTANCE GLULAM

Glulam Because of its beauty, strength and ease of construction, wood has long been in demand as a building material. Today, structural glued laminated timbers (known as glulam) offer additional reasons to select wood as a structural material. Glulam is fabricated using individual pieces of highstrength, kiln-dried lumber, laminated together under pressure to form large timbers that retain the traditional beauty of wood along with engineered strength and extraordinary fire resistance, thermal efficiency, and dimensional stability. Glulam is typically manufactured using Douglas fir, Hem-Fir, Southern pine, Spruce-Pine-Fir, Alaskan Yellow cedar and Ponderosa pine. These large, laminated timbers can be fabricated in almost any straight or arched configuration for long-span conditions. This allows for the design of large, open spaces with minimal columns. Long-length glulam are appropriate for complete structural systems in many types of buildings including churches, gymnasiums, auditoriums and recreational spaces. Everyday uses in smaller buildings include ridge beams, garage door headers, door and window headers, long-span girders, stair treads and stringers, and heavy timber trusses.

Efficient, Cost-Effective Fire Protection In the United States, the use of glulam is widely accepted as one of the most efficient and least expensive ways to meet the recognized criteria for fire protection as set forth in the U.S. model building codes. Advances in test methods and fire technology have increased our understanding of how glulam responds to fire exposure. This knowledge, in turn, has led to the development of design procedures that further improve fire performance. FIREPROOF VERSUS FIRESAFE Fireproof buildings do not exist. The contents of most buildings are combustible. As such, it is often a building s contents, not its structural components, which pose the greatest potential fire hazard to life and property. Fire occurrences in the contents of so-called fireproof buildings can be so severe that a building constructed with non-combustible framing can collapse. The fire in Chicago, Illinois McCormick Place exhibition hall is a classic example. All structural members of this large exhibition hall, including interior nonbearing walls, were constructed of non-combustible materials. In 1967, a fire quickly spread through the contents of the hall, generating temperatures so high that steel beams, girders and trusses buckled in the heat and the entire roof collapsed. The building was a total loss at a cost of $150 million. With this lesson and others, the goal has become fire safe design, rather than fireproof, and it can be achieved with combustible structural materials as long as building code regulations are met. In addition to structural materials, considerations include the combustibility of contents and furnishings, interior finishes, the degree of protection provided by interior sprinklers, and the availability of adequate firefighting equipment. A reliable smoke detector with an alarm system and easily accessible exits are also vital in protecting a building and its occupants. LEFT: Two tiers of glulam arches rise to more than 24 metres at the highest point in the Great Buddha Hall in Carmel, NY. ABOVE: Aftermath of the fire at Turbotech, Inc. in Vancouver, Washington (USA). Glulam remained standing while the rest of the so-called fireproof building collapsed.

Performance of Large Timbers in Fires When exposed to fire wood retains its strength for a longer period of time than metal. Unprotected metals quickly lose their strength and collapse suddenly, often with little warning. In contrast, wood loses strength slowly and only as material is lost through surface charring. Average building fire temperatures range from approximately 700º to 900º Celsius. Steel weakens dramatically as its temperature climbs above 230ºC, retaining only 10% of its strength at about 750ºC. As a rule, wood will not ignite until it reaches a temperature of around 250ºC. Once it catches fire, wood typically develops char at the rate of 0.64mm per minute under severe fire conditions. The char naturally insulates the wood and raises the temperature level it can withstand. Thus, in a 30-minute fire, only 19mm of each exposed surface of the glulam is lost to charring, leaving most of the original cross section intact. FIRE SAFETY In nearly every country, one or more regulatory agencies concern themselves with the fire safety of building materials and systems. In the U.S., these include: Model Building Code organizations develop design requirements, compliance criteria and regulatory oversight for building construction. Regulatory agencies participate in the development of these provisions. American Society of Testing Materials (ASTM) promulgates fire test methods for building materials and systems. - ASTM Test Method E-119 approximates actual fire conditions for building assemblies (beams, walls and connectors) and results in the development of fire-resistance ratings for building assemblies. - ASTM E-84 Standard Test Method for Surface Burning Characteristics of Building Materials provides data on flame-spread ratings/ classifications and smoke-developed indexes for materials. COMPARATIVE STRENGTH LOSS OF WOOD VERSUS STEEL 100 90 80 70 60 50 40 30 20 10 0 50% loss 550 C WOOD STEEL 25% loss @ 30 minutes 90% loss @ 30 minutes 750 C 0 10 20 30 40 TIME (MINUTES) Results from test sponsored by National Forest Products Association at the Southwest Research Institute ABOVE (top): Steel beams have melted and collapsed over charred timber beam, which, despite heavy damage, remains in place. ABOVE (middle): 406mm, 60 kg/m steel beam (#W16x40) and 178mm x 533mm glulam beam following fire testing under full load. Steel beam collapsed after only 30 minutes of exposure while the glulam member remained straight and true, charring on 19mm on exposed surfaces.

Guide to Fire Performance Buildings constructed with large structural timbers have excellent fire-resistive qualitites. U.S. model building codes recognize these qualities and provide guidelines for fire-resistive, heavy timber construction approaches. Two distinct approaches are included in the U.S. model building codes: Heavy Timber Construction and Fire-Resistive Construction. HEAVY TIMBER CONSTRUCTION In Heavy Timber Construction, limitations are placed on the minimum size, including depth and thickness, of all load-carrying wood members. The design avoids concealed spaces under floors and roofs, and regulations require the use of approved fastenings and construction details. When properly sized, glulam systems meet the criteria set forth in U.S. model building codes for Heavy Timber Construction. The performance of heavy timber structures under fire conditions is markedly superior to most unprotected non-combustible construction. Fire fighting is easier and safer due to the elimination of concealed spaces and the inherent structural integrity of large laminated timbers. ADAPTING STANDARD BEAM LAY-UP TO MEET ONE-HOUR FIRE RESISTANCE STANDARD BEAM LAY-UP Compression lams at top Core lams in center Tension lams at bottom One core lam removed from center One tension lam added to bottom 1-HR RATED BEAM LAY-UP The basic lam lay-up can easily be modified to qualify for 1-hour fire rating by removing one core lam from center of member and adding one additional tension lam to tension face, assuming all requirements are satisfied. FIRE-RESISTIVE CONSTRUCTION Fire resistance is the length of time a structural member can support its load before collapsing. The goal of fire-resistive construction is to provide adequate time for occupants to evacuate a building safely. The results of ASTM fire tests for building assemblies, sponsored jointly by the American Forest & Paper Association and the American Institute of Timber Construction (AITC), enable designers to calculate specific fire ratings for glulam members. Calculations are based on a consideration of member size, degree of fire exposure, and loads on the member. Additionally, fire-resistance ratings for glulam beams require lay-up modifications. For example, a simplespan glulam beam, having a cross section of 170mm x 340mm and exposed to fire on three sides, can be sized for a one-hour fire rating. To qualify for this rating, an inner or core lamination is removed from the beam at the time of manufacture and replaced by adding an additional tension lamination to the bottom of the beam (as shown in the figure above right). ABOVE (middle): Typical glulam beam enveloped in flames during standard ASTM E-119 fire test. ABOVE (bottom): Typical glulam beam following fire testing: the outer surface of the beam has charred while the inner areas remain unburned. The charred outer material acts as an insulator during fire, reducing the rate at which the inner material will burn. For additional information related to calculating a fire rating for heavy timber members, please refer to AITC Technical Note No.7 Calculation of Fire Resistance of Glued Laminated Timbers (www.aitc-glulam.org) and to AF&PA Technical Report 10 Calculating the Fire Resistance of Exposed Wood Members (www.awc.org). These publications are available in English.

Other Fire-Resistance Considerations FIRE-RETARDANT TREATMENTS AND COATINGS Pressure impregnated, fire-retardant treatments are not recommended for large timber or glulam construction. These treatments do not increase the fireresistance rating of the large timber or glulam. Fire-retardant chemicals reduce the design properties of the wood. In addition, for engineered wood products, the treatments may not be compatible with the adhesives used. The designer is cautioned to verify the effects of fire-retardant treatments (with the supplier) on the strength and performance of any wood product prior to specifying. Fire-retardant paints and stains can effectively reduce flame spread when properly applied. While typically applied to large expanses of interior wood surfaces such as panel products, they can be applied to timber members when a specific flame-spread rating is required per design regulation. However, it is important to understand these coatings do not increase the fire-resistance rating for large timber or glulam members. SPRINKLER SYSTEMS Automatic sprinkler systems have an excellent record of improving fire safety and reducing losses. Many fire codes require that automatic sprinkler systems be installed in commercial buildings, and in some cases, added to existing buildings. Such sprinkler systems may improve the fire-resistance and flame-spread ratings for a building s structural system. As a result, an additional storey of height or an increased building area may be permitted (by the codes) for buildings with sprinklers. Sprinkler systems also reduce insurance premiums with the result that a sprinkler system often pays for itself within a matter of years, depending on the value of the building and its contents. FIRE INSURANCE RATES Most insurance companies recognize the excellent fire resistance of heavy timber construction and adjust their insurance rates accordingly. However, in some case, insurance premiums for noncombustible construction may be lower than for heavy timber construction. In such instances, the reduced cost of glulam construction generally offsets any additional insurance cost. In addition, the more expensive construction methods required for noncombustible materials increase the cost of financing a project. Increased financing costs generally exceed any potential savings on insurance. Thus, using more expensive construction methods, in order to gain lower insurance rates, may actually result in increased overall costs. INCREASING ALLOWABLE AREAS FOR HEAVY TIMBER CONSTRUCTION U.S. building codes place height and area limitations on buildings to safeguard building occupants. While wood construction is typically assigned the lowest, basic allowable heights and areas, the model building codes also provide many options for increasing allowable areas. The following list provides suggestions for how to increase, under U.S. model building codes, the allowable areas for wood construction while maintaining life safety for building occupants: 1. Provide one-hour fire-resistive ratings for structural members and assemblies. 2. Install automatic sprinkler systems. 3. Maintain separation between buildings where possible. 4. Seek unlimited areas where appropriate, for specific types of building uses, by providing open spaces around the building combined with the use of automatic sprinklers. 5. Install properly constructed area-separation walls with protected openings. RIGHT: Long-span glulam reduce the need for interior columns in the second-floor office space of Green Gables Timber Frame Barn, Lake Geneva, WI.

Quality Control and Inspection AITC provides Quality Marks and Certificates of Conformance to licensed glulam manufacturers. Only AITC-licensed glulam producers are permitted to use these Quality Marks and Certificates to identify products conforming to ANSI/AITC A190.1. AITC strives to bring together all aspects of the engineered timber industry through providing proper specifications and oversight on products for safe, long-lasting, high-quality timber construction. AITC s Quality Control and Inspection Program for structural glued laminated timber works to: Standardize production, testing, inspection, identification, and certification of structural glued laminated timber. Improve economies through wider utilization of standards. Ensure the manufacture of reliable products. The Program consists of three basic elements: Licensing of qualified glulam manufacturers whose personnel, procedures and facilities comply with the requirements of the American National Standard for Wood Products Structural Glued Laminated Timber ANSI/AITC A190.1. Continuous maintenance of the qualified manufacturer s quality control system in accordance with ANSI/AITC A190.1. Periodic inspection and verification, by the AITC Inspection Bureau, of the licensed laminator s quality control system, procedures and production.

AITC and its member glulam manufacturers support the Softwood Export Council (SEC) which is a nonprofit trade council of U.S. softwood grading agencies, industry trade associations, state export development agencies and others interested in the promotion of U.S. softwood products internationally. The SEC website provides information on member organizations, services and companies as well as a directory of literature and supporting information on products. Most publications, many available in multiple languages, may be ordered directly from the nearest SEC field office. International field offices and SEC representatives are located in Tokyo, Seoul, Beijing, Madrid, London and Vera Cruz, Mexico. Details are provided on the SEC website. Softwood Export Council USA email: info@softwood.org website: www.softwood.org ABOVE: Glulam are a popular choice for the structural systems in recreational spaces. Boathouse, Princeton University. FRONT COVER: Glulam may be fabricated in variety of configurations to meet specific design requirements. Public Library, Beaverton, OR. FOR ADDITIONAL INFORMATION, PLEASE CONTACT: American Institute of Timber Construction 7012 S. Revere Parkway, Suite 140 Centennial, CO 80112 USA tel: (303) 792.9559 fax: (303) 792.0669 email: info@aitc-glulam.org website: www.aitc-glulam.org 2003 American Institute of Timber Construction AITC-2 / 1-04 / 1,000