PART 1 GENERAL 1.1 SECTION INCLUDES A. Translucent sandwich panel window wall systems utilizing fiber reinforced thermoset profiles.

Similar documents
SECTION FIBERGLASS SANDWICH PANEL ASSEMBLIES

SECTION FIBERGLASS SANDWICH PANEL SKYLIGHTS

1.2 RELATED REQUIREMENTS

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION / TRANSLUCENT WALL AND ROOF ASSEMBLIES (WINDOW WALL SYSTEMS)

SECTION / METAL FRAMED SKYLIGHTS (TRANSLUCENT PANEL SYSTEM)

SECTION / METAL FRAMED SKYLIGHTS

SECTION TRANSLUCENT PANEL SYSTEM

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

Job No Division 07 Section "Sheet Metal Flashing and Trim" for metal flashings installed at perimeters of assemblies.

MPG Series 2250T Thermally Broken Aluminum Window

SECTION ALUMINUM WINDOWS

Heavy Commercial / Architectural Projected Windows Series L900T AW150

MPG Series 2780-ZS Thermally Broken Aluminum Window Zero Sightline Series

SPECIFICATIONS SECTION 08600

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Series B450 Guide Specification

SECTION STAINLESS STEEL WALL PANELS

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

SECTION SECURITY PROTECTION PART 1 GENERAL

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

Corium Brick Rainscreen System Specifications

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

SPECIFICATIONS FOR EAST HOLLAND STABLES VENT RIDGE SYSTEM & GABLE WALLS

Phenolic Exterior Wall Cladding

SECTION ALUMINUM WINDOWS

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels

Product Guide Specification

Product Guide Specification

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

Union County Vocational - Technical Schools Scotch Plains, New Jersey

ALUMABOARD SECTION ALUMINUM SIDING AND SOFFITS. A. Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

by Rollfab Metal Products

SPECIFICATIONS SECTION

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes)

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

LOG COLLEGE MIDDLE SCHOOL

PRODUCT SPECIFICATION SERIES 4500T THERMALLY BROKEN ALUMINUM SLIDING BALCONY DOOR

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

SECTION FOLDING ALUMINUM FRAMED WALL SYSTEM

SECTION ORNAMENTAL ALUMINUM RAILING

Architectural Wall Products Guide Specifications

CS-100 Guide Specifications

North Hanover Township School District North Hanover Township, New Jersey

PRODUCT SPECIFICATION UNITIZED CURTAIN WALL THERMALLY BROKEN ALUMINUM AWNING/ FIXED WINDOW

Guide Specification for Pre-Engineered Skylight System. A. Engineering, design and drafting of the entire skylight system.

SECTION METAL WALL PANELS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

GUIDE SPECIFICATIONS - SECTION ALUMINUM WINDOWS Manko Window Systems Inc SERIES (Single Hung)

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS

08620 UNIT SKYLIGHTS Tufflite double polycarbonate glazed Frb

SECTION PHENOLIC LOCKERS AND BENCHES. B. Section Gypsum Board Area Separation Wall Assemblies.

SECTION METAL FRAMED SKYLIGHTS

SECTION PORCELAIN TILE WALL SYSTEM. (Porcelanosa Venis Urbatek)

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

SECTION SERIES 200 DOUBLE-HUNG VINYL WINDOWS

FL550T 21/2 x5. GUIDE SPECIFICATION Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront. Thermal Impact-Resistant Storefront

SECTION METAL WALL PANELS

Alply CLASSIC WALL Architectural Insulated Panel Wall System

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

SECTION ALUMINUM STORM WINDOWS

PRODUCT SPECIFICATION SERIES 5000T PUNCHED WINDOW THERMALLY BROKEN ALUMINUM CASEMENT/AWNING/ FIXED WINDOW

SECTION STRUCTURAL INSULATED PANELS

Guideline Specifications

FL550 21/2 x5 GUIDE SPECIFICATION. Impact-Resistant Storefront

Product Guide Specification

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Architectural Roof and Wall Products Guide Specifications

Master Specifications for Microcotta November 2017

SECTION DETAILS (MECHANICALLY ASSEMBLY)

Page 1 of 5

SECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

Product Guide Specification

Expansion Joint Covers

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION ALUMINUM STORM WINDOWS

COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY)

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

SECTION PREHUNG WOOD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION ALUMINUM GLASS FLOOR SKYLIGHT SYSTEMS

Expansion Joint Covers (079513)


SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

FINA Stoneworks NATURAL STONE HONEYCOMB REINFORCED PANEL SYSTEM

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

PRODUCT SPECIFICATION THE 9500 SERIES FAMILY - SERIES 9502 / 9503 THERMALLY BROKEN ALUMINUM OUTSWING BALCONY DOOR

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Transcription:

This product guide specification is written according to the Construction Specifications Institute (CSI) Format, including MasterFormat 2012 Edition and SectionFormat/ PageFormat 2005, in the CSI Project Resource Manual. The section must be carefully reviewed and edited by the Architect to meet the requirements of the project and local building code. Coordinate this section with other specification sections and the drawings. SECTION 08 45 23 FIBERGLASS SANDWICH PANEL ASSEMBLIES Specifier Note: This section covers Clima-Tite " Translucent Window Wall Systems from Major Industries. The wall systems feature structural composite sandwich panels with translucent skins, thermally broken grid core and fiber reinforced thermoset framing, with an integrated glass window. Consult Major for assistance in editing this section for the specific application. PART 1 GENERAL 1.1 SECTION INCLUDES A. Translucent sandwich panel window wall systems utilizing fiber reinforced thermoset profiles. Specifier Note: Edit the following as required. List items specified elsewhere that are directly related to this section. 1.2 RELATED REQUIREMENTS A. Structural Steel/Metal Fabrications/Rough Carpentry - Section. B. Sheet Metal Flashing and Trim - Section. C. Joint Sealants - Section. 1.3 ADMINISTRATIVE REQUIREMENTS FOR SEQUENCING A. Ensure that locating templates and other information required for installation of wall system(s) are furnished to affected trades in time to prevent interruption of construction progress. B. Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress. 1.4 SUBMITTALS A. Product Data: Manufacturer's data sheets on each product to be used, including preparation instructions and recommendations, storage and handling requirements, installation methods and maintenance instructions. B. Shop Drawings: Include plans, elevations, sections, and details, indicating dimensions, tolerances, profiles, anchorage, connections, fasteners, provisions for expansion and contraction, drainage, flashing, finish, glazing, and attachments to other Work. C. Samples: 1. Submit sample sets of color chips for initial selection representing manufacturer's full range of available colors and finishes. 2. Submit samples for verification, consisting of at least one sample, minimum 6 inches high by 12 inches wide, representing actual product (including framing) and color(s). D. Design Data: 1. Submit manufacturer's structural calculations showing sizes of framing members and loads applied to supporting structure based on design loads. 2. Submit any required signed and sealed structural calculations prepared by a qualified professional engineer who is licensed in the state where system is to be installed. E. Manufacturer's Certificates: Submit documentation in writing certifying that products meet or exceed the specified requirements. F. Sustainable Design Submittals: 1. Submit material as requested including percentages by weight of post-consumer/ post-industrial recycled content, locally manufactured/ harvested materials and any applicable VOC content. G. Test Reports: Submit certified test reports from a qualified independent testing agency, indicating wall systems comply with specified requirements. Submit results from the following: 1. Flame spread and smoke development, ASTM E 84. 2. Burn extent, ASTM D 635. 3. Color change, ASTM D 2244 in accordance with ASTM D 1435. 4. Impact strength, exterior face sheets, UL 972. 5. Accelerated aging, ASTM D 1037. Section 08 45 23 - Page 1 of 6

6. Bond strength, ASTM C 297. 7. Insulating U-factor, ASTM C 1199. 8. Self-ignition, ASTM D 1929. 9. Class A burning brand, ASTM E 108. 10. Air infiltration, ASTM E 283. 11. Water penetration, ASTM E 331. 12. Uniform load deflection, ASTM E 72 and E 330. 13. Concentrated and Impact, ASTM E 661. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: Minimum ten years documented experience in the fabrication of wall systems similar to the type required and capable of providing field service representation during installation. B. Installer Qualifications: Minimum five years documented experience in the work of this section, specializing in work similar to project requirements and approved by manufacturer. 1.6 DELIVERY, STORAGE AND HANDLING A. Delivery: Deliver to site in manufacturer's original, unopened containers and packaging, with labels clearly identifying product name, manufacturer, and installation location. B. Storage/Handling: Store products above the floor and under cover in a clean, dry area until installation. Protect materials and finish from damage during handling and installation. 1.7 SITE CONDITIONS A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits. 1.8 WARRANTIES Specifier Note: Delete items not required. Major will provide the standard warranty unless otherwise specified. Optional warranties available at additional cost. Contact Major Industries for specific warranty information and details. A. Exterior Fiberglass Color Change (select unless otherwise specified): 1. Provide manufacturer's standard 10 years or <as specified>. 2. Optional: 15 years / 20 years. B. Material Workmanship (select one): 1. Provide manufacturer's standard 1 year or <as specified>. 2. Optional: 5 years / 10 years. C. Fiberglass Fiberbloom: Provide manufacturer s standard 20 year warranty or <as specified>. Specifier Note: Choose one finish/warranty option below. Delete items not required. D. Finishes: (Please Select One. Consult Major Industries for assistance). 1. Organic Coatings for Fiber Reinforced Thermoset Profiles: AAMA 623-07 a. Provide manufacturer's standard 1 year or <as specified>. 2. High Performance Organic Coatings for Fiber Reinforced Thermoset Profiles: AAMA 624-07 a. Provide manufacturer's standard 5 year or <as specified>. b. Optional: 10 years. PART 2 PRODUCTS 2.1 TRANSLUCENT WINDOW WALL SYSTEMS A. Clima-Tite Translucent Window Wall System: 1. Overall Dimensions: width x length (Contact Major for restrictions). 2.2 DESIGN / PERFORMANCE REQUIREMENTS A. Performance Requirements: 1. Framing Members: Sufficient sizes as required to support design loads. B. Deflection Limits: Shall not exceed: L/120 per IBC code requirements. C. Safety Factors: Allowable stresses shall incorporate following safety factors, unless otherwise specified: Load Carrying Members: 1.65, Load Carrying Fasteners: 2.0. Section 08 45 23 - Page 2 of 6

D. Expansion and Contraction: Design and install components with provisions for expansion and contraction due to a 100 degree F (56 degrees C) temperature variation. E. Design Loads: Framing components shall be designed to support the following loads: 1. Live Load (Select One): a. psf. b. As indicated on the Drawings. 2. Wind Load (Select One): a. psf. b. As indicated on the Drawings. 3. Alternate Design Loads: Contact Major Industries for assistance. F. Design Calculations: 1. Provide calculations prepared and stamped by a registered professional engineer, qualified in the design of wall systems and licensed in the state where wall systems are to be installed. 2.3 MANUFACTURERS A. Acceptable Manufacturer: Major Industries Inc., 7120 Stewart Ave, Wausau, WI 54401; Tel: 888-759-2678 / 715-842-4616; Fax: 715-848-3336; info@majorskylights.com. B. Requests for substitutions considered in accordance with provisions of Section 01600. 2.4 COMPONENTS A. Translucent Panel Units: 1. Construction: Facings of ICC ES listed architectural-grade fiberglass reinforced polymer sheets bonded under controlled heat and pressure to a mechanically-interlocked aluminum I-beam grid core to form double-faced, self-supporting, structural composite sandwich panels. a. Thickness: 2-3/4 inches (699 mm). Specifier Note: Contact Major for information related to panel widths and lengths for your specific system. b. Panel Maximums: 5 feet (1.52 m) wide / 16 feet (4.88m) long. Specifier Note: Specify one of the following insulating U-factors. Center of Panel numbers are listed in section c below and are determined using NFRC test methods and are for glazing comparisons only. NFRC 100-2010 certified system values are listed in section d and are available for standard configurations. Test sample 78 3/4 inches x 78 3/4 inches, consisting of two translucent panels, three vertical rafters and perimeter head and sill. Consult Major Industries for assistance. c. U-Factor: Center of Panel U-factor (for glazing comparison only) 1) 0.48. 2) 0.20. 3) 0.17. 4) 0.08. d. U-Factor: NFRC 100-2010 certified values for translucent panel wall sections (including thermally broken internal grid and fiber reinforced thermoset framing) 5) 0.50. 6) 0.25. 7) 0.22. 8) 0.14. e. Grid Pattern (Select One Contact Major for Custom Pattern Options): 1) In-line Shoji. 2) Staggered Shoji. 3) Tuckerman. 4) Verti-Lite (vertical grid only) f. Nominal Grid Size (Select One Contact Major for Custom Size Options): 1) 12 inches by 24 inches (304 mm by 610 mm). 2) 12 inches by 12 inches (304 mm by 305 mm). 3) 8 inches by 20 inches (203 mm by 508 mm). 4) 8 inches by 8 inches (203 mm by 203 mm). 5) 6 inches by 6 inches (152 mm by 152 mm). 6) Verti-Lite pattern - 12 inches wide (304mm) maximum. g. Unbonded Areas: Maximum of 4 unbonded areas, a maximum of 3/64 inch Section 08 45 23 - Page 3 of 6

(.11 mm) in diameter, in an area a maximum of 40 square feet of panel surface. h. Panel Weeps: Weep holes provided on down slope side of installed panels to permit condensation to leave panel interior. i. Assembly: Factory assembled. Field assembly of panels not allowed. 2. Physical Properties: a. ASTM E 108 - Burning Brand: Class A rating. b. ASTM E 72 and E 330 - Uniform Load Deflection. c. ASTM E 661 - Concentrated and Impact. d. ASTM E 283 - Air Infiltration through fixed panel system and perimeter framing: less than 0.01 cfm/ft air leakage at 6.24 psf air pressure. e. ASTM E 331 - Water penetration through fixed panel system and perimeter framing. No leakage when water is applied to entire panel surface at rate of 5 gal/hr/sq ft for 15 minutes at 12 psf air pressure. 3. I-Beam Grid Core: a. Material: Aluminum Alloy 6061-T6. b. 7/16 inch (11 mm) minimum flange width, 0.050 inch (1.27 mm) web thickness. c. Mechanically interlocked. d. Full surface contact with face sheets. e. Thermal Break: Poured and debridged structural polyurethane. 4. Adhesive: a. Waterproof resin for use in laminating face sheet to aluminum grid core. b. Impact and Thermal Shock: Adhesive capable of withstanding impact and thermal shock normally encountered in exterior construction. c. Adhesive Bond Line: Straight, black, cover entire width of I-beam, with neat edge. d. Initial Adhesive Bond Strength: Shear Strength, ASTM D 1002: 563 psi, Tensile Strength, ASTM C 297: 557 psi minimum. e. Aged Adhesive Bond Strength, ASTM D 1037: Shear Strength, ASTM D 1002: 1212 psi, Tensile Strength, ASTM C 297: 914 psi. 5. Translucent Face Sheets: a. Appearance of Face Sheets: 1) Uniform in color to prevent splotchy appearance. 2) Free of ridges, wrinkles, clusters of air bubbles and pinholes. 3) ICC-ES listed (ER 2026). b. Exterior Face Sheet: 1) ASTM D 2244: Color change shall not exceed 3.0 Delta E units after 5 years of weathering (accelerated Arizona / simulated South Florida testing). 2) Protective Weathering Surface: a) Application: Factory-applied. b) Minimum Thickness: 1.0 mil. c) Repairs: Fully field repairable. 3) Impact Strength, UL 972 / Thickness (Select One): a) Standard - 70 foot-pounds / 0.070 inches (1.77 mm). b) High-impact (optional) - 360 foot-pounds / 0.070 inches (1.77 mm). 4) Color (Select one - Consult Major for availability of custom colors): a) White. b) Crystal. c) Ice Blue. d) Aqua. e) Tan. f) Desert Rose. c. Interior Face Sheet: 1) Flame Spread, ASTM E 84: 10 maximum. 2) Smoke Development, ASTM E 84: 300 maximum. 3) Burn Rate, ASTM D 635: 1.0 inch per minute maximum. 4) Self-Ignition, ASTM D 1929: Greater than 650 degrees F. Section 08 45 23 - Page 4 of 6

5) Thickness (Select One): a) Standard - 0.045 inches. b) High-impact - 0.060 inches (optional). 6) Color (Select one - consult Major for availability of custom colors): a) White. b) Crystal. B. Integrated Window Units: 1. Window Construction: All windows shall be constructed of fiber reinforced thermoset framing members, and designed specifically for seamless integration into the Clima-Tite system. Specifier Note: Contact Major for additional details and options related to fixed and projecting windows. 2. Window Types: a. Select One: Outward Projecting / Fixed 3. Glazing: a. Low-E, dual panel glass. 4. Framing Materials: a. Fiber reinforced thermoset. Specifier Note: If a fixed window was chosen above, delete the Hardware and Screen sections below. 5. Hardware: a. Hinges: Provide two adjustable friction hinges per vent meeting AAMA 904.1. b. Locks: Die cast stainless steel cam locks, strikes and/or keepers for manual or custodial operation shall secure sash in closed position. Provide locks at maximum 40 inch spacing and double grip hardware for locks exceeding 6 feet from floor. c. Operating Handles: Folding, butterfly or round handles. 6. Screens (Optional Full): a. Frames shall be in accordance with ANSI/SMA 1004. b. Aluminum cloth shall comply with GSA-FS-RR-W-365 and USDC-CS-138. C. Components and Framing: 1. Fiber Reinforced Thermoset: a. Construct wall system of extruded fiber reinforced thermoset shapes in accordance with sections indicated on the Drawings. Minimum Thickness: 0.040 inch. 2. Interior/Exterior Glazing Gaskets: a. Factory installed (in extruded dovetail slots) EPDM hybrid, 9/16 inch wide. b. Compression Deflection, 25% Deflection Limits, ASTM D 1056, 13 to 24 psi. c. Compression Set, 22 Hours at 158 Degrees F, ASTM D 395, Method B: 30 psi. d. Heat Aging, 70 Hours at 212 Degrees F, Change in Compression Values, ASTM D 865 and D 1056: 0 to 10 psi. e. Dimensional Stability, Change Maximum Percent after Heat Aging, 70 Hours at 212 Degrees F, 4 psi: 11.4%. f. Ozone Resistance at 40% Elongation, 100 Hours at 104 Degrees F, ASTM D 1149: Type I, 1 Ppm Ozone: No cracks / Type II, 3 Ppm Ozone: No cracks. g. Water Absorption, Percent of Weight: Option I: 5.0% / Option II: 11.7%. h. Flame Propagation: Option I, 4 Inch Maximum: 11.7% / Option II, No Limit: 11.8%. i. Straining of Surface, ASTM D 925: Non-straining, no migratory strain. 3. Flashing and Components: a. Extruded Aluminum: ASTM B 221, Alloy 6063-T5/T6, 6061-T5/T6, or equivalent. b. Formed Aluminum Components/Flashing: ASTM B 209, Alloy 5005-H34 or equivalent. D. Condensation Control System: 1. Mechanically design to function properly with minimal dependency upon sealants. 2. Provide an integral gutter system on all framing members. E. Custom Designs: 3D modeling used to verify custom fitting and assembly. F. Expansion and Contraction: Design and install components with provisions for expansion and contraction due to a 100 degree F temperature variation. G. Glazing Caps: 1. Fiber reinforced thermoset profiles. 2. All caps attached using snap-to-lock connections. Mechanical fasteners not allowed. Section 08 45 23 - Page 5 of 6

H. Fasteners: 1. Clips for Attachment of Mullions: Aluminum - attach using bolted fastening methods. 2. Construction and Glazing Cap Fasteners: 300 series stainless steel. 2.5 FABRICATION A. Weep Holes in Sill Components: Located as required to control condensation that may enter system by allowing it to pass to exterior. B. Construct system framing of fiber reinforced thermoset shapes as indicated on the Drawings. 2.6 FIBER REINFORCED THERMOSET FRAMING FINISHES Specifier Note: Specify one of the following finishes. Custom colors available. Consult Major for assistance. A. Organic Coatings for Fiber Reinforced Thermoset Profiles: AAMA 623-07 Color: (or as indicated on the Drawings). B. High Performance Organic Coatings for Fiber Reinforced Thermoset Profiles: AAMA 624-07 Color: (or as indicated on the Drawings). PART 3 EXECUTION 3.1 EXAMINATION A. Examine areas to receive translucent wall system with installer and manufacturer's representative present, including supporting structure and substrate for dimensions, tolerances, material conditions, and support. B. Notify Architect of conditions that would adversely affect installation or subsequent utilization of wall system and do not proceed until conditions are corrected. 3.2 PREPARATION A. Clean surfaces thoroughly prior to installation. B. Ensure supports to receive wall system are clean, flat, level, plumb, and square. C. Aluminum Protection: Where aluminum will contact dissimilar materials, apply a coating of bituminous paint or other neutral material or separate with a nonabsorbent isolator. 3.3 INSTALLATION A. Install wall systems level, plumb, square, and accurately aligned, and in accordance with manufacturer's instructions at locations indicated on the approved drawings. B. Do not install wall system components with deficiencies or dimensional errors. Do not proceed with installation until unsatisfactory components are replaced. C. Anchor wall system securely to supports using attachment methods that permit adjustment for construction tolerances, irregularities, alignment, and expansion and contraction. D. Install wall system and related components as required for a complete, weatherproof installation. 3.4 FIELD QUALITY CONTROL A. Water Test: Test wall system according to procedures in AAMA 501.2. B. Repair or replace work that does comply with specified requirements and retest work. C. Examine installation of sheet metal flashing and sealants. D. Examine all face sheets for cracks, deep scratches, and other damage, and inspect protective weathering surface of exterior sheet. Repair in accordance with manufacturer's instructions. 3.5 CLEANING A. Clean wall system inside and outside, including member connections and inside corners, immediately after installation and after sealants have cured, but not more than 10 days after installation. B. Follow related cleaning instructions in accordance with manufacturer's recommendations. 3.6 PROTECTION A. Protect installed products until completion of project. B. Touch-up, repair or replace damaged products before Substantial Completion. END OF SECTION Section 08 45 23 - Page 6 of 6