ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

Similar documents
DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: POLYVINYL CHLORIDE ROOFING REPORT HOLDER: IB ROOF SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

ESR-1794* Reissued September 1, 2012 This report is subject to renewal November 1, 2014.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-APPLIED WOOD COATINGS SECTION: SHEATHING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOF PANELS REPORT HOLDER: ONDULINE NORTH AMERICA, INC. EVALUATION SUBJECT:

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC 250 WEST 96 TH STREET INDIANAPOLIS, INDIANA EVALUATION SUBJECT:

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC

REPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA EVALUATION SUBJECT:

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

SPECIFICATION SUBMITTAL

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

UL Evaluation Report UL ER Issued: June 29, 2015 Revised: July 29, UL Category Code: ULFB. CSI MasterFormat

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER: POLYGLASS USA, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

PRODUCT CONTROL SECTION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

SPECIFICATION SUBMITTAL

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

PRODUCT CONTROL SECTION

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

PRODUCT CONTROL SECTION

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: METACRYLICS

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ETHYLENE PROPYLENE DIENE MONOMER ROOFING REPORT HOLDER:

ESR-2847 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: BORAL COMPOSITES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

4.2 Materials Membranes: inch, inch or inch thick D General

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

UL Evaluation Report UL ER Issued: July 25, UL Category Code: ULFB. CSI MasterFormat

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMOPLASTIC MEMBRANE ROOFING SECTION: POLYVINYL-CHLORIDE ROOFING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE DOW CHEMICAL COMPANY

REPORT HOLDER: STAR R FOAM MANUFACTURING, INC. EVALUATION SUBJECT: STAR R FOAM INSULATION BOARDS

REPORT HOLDER: COREV AMERICA BRITTMOORE PARK DRIVE HOUSTON, TEXAS EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: INSULATING CONCRETE FORMING REPORT HOLDER: DIVERSIFOAM PRODUCTS EVALUATION SUBJECT:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PRODEMA USA INC. EVALUATION SUBJECT:

ESR-1061 Reissued May 1, 2011 This report is subject to renewal in two years.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER: THE GARLAND COMPANY, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

REPORT HOLDER: GREENMAKER INDUSTRIES, LLC 697 OAKWOOD AVENUE WEST HARTFORD, CONNECTICUT EVALUATION SUBJECT: DECOPLAST DDARS NOTCHED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF TILES REPORT HOLDER: GERARD ROOFING TECHNOLOGIES EVALUATION SUBJECT:

UL Evaluation Report UL ER Issued: December 19, 2014 Revised: August 14, UL Category Code: ULFB. CSI MasterFormat

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC. EVALUATION SUBJECT:

UL Evaluation Report UL ER Issued: May 31, Revised: June 6, UL Category Code: ULEZ. CSI MasterFormat

(800) (562) A Subsidiary of the International Code Council

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

DIVISION: CONCRETE SECTION: CEMENTITIOUS WOOD FIBER DECKS DIVISION: FINISHES SECTION: ACOUSTIC ROOM COMPONENTS

Joint Evaluation Report ICC-ES (800) (562)

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: FINISHES SECTION: PORTLAND CEMENT PLASTERING REPORT HOLDER: SOMAR INDUSTRIES LTD LUCKETT COURT EL PASO, TEXAS 79932

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

Transcription:

ICC-ES Evaluation Report ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 52 00 Modified Bituminous Sheet Roofing REPORT HOLDER: TAMKO BUILDING PRODUCTS, INC. POST OFFICE BOX 1404 JOPLIN, MISSOURI 64802 (417) 624-6644 www.tamko.com EVALUATION SUBJECT: TAMKO MODIFIED BITUMEN ROOF COVERING SYSTEMS 1.0 EVALUATION SCOPE Compliance with the following codes: 2006 International Building Code (IBC) 2006 International Residential Code (IRC) 1999 Standard Building Code (SBC) Properties evaluated: Fire classification Wind uplift resistance Physical properties Impact resistance 2.0 USES The TAMKO modified bitumen roof covering membranes are used as roof coverings in Class A, B and C roof covering systems, described in this report, on new or existing roofs. 3.0 DESCRIPTION 3.1 General: TAMKO roofing membranes are styrene butadiene styrene (SBS) modified bitumen Type 1 or Type II, Grade G, membranes complying with ASTM D 6164, intended for hot asphalt or self-adhered applications. Roof covering systems utilizing TAMKO roofing membranes consist of the Awaplan membranes, base and cap sheets and ply sheets, approved insulation, flashing, asphalts, and mechanical fasteners that are installed to produce an integrated roof system. 3.2 Membranes: 3.2.1 : is a 0.15- inch-thick (3.8 mm), granular-surfaced, reinforced, modified bitumen roofing membrane manufactured from a nonwoven polyester fabric impregnated and covered with SBS modified bitumen. The membrane weighs approximately 8 pounds per square yard (4.3 kg/m 2 ). 3.2.2 FR: FR is a 0.155-inch-thick (3.94 mm), granular-surfaced, reinforced, modified bitumen roofing membrane manufactured from a nonwoven polyester fabric impregnated and covered with SBS modified bitumen. The membrane weighs approximately 8 pounds per square yard (4.3 kg/m 2 ). 3.2.3 Awaplan 170: Awaplan 170 is a 0.1-inch-thick (3.6 mm), granular-surfaced, reinforced, modified bitumen roofing membrane manufactured from a nonwoven polyester fabric impregnated and covered with SBS modified bitumen. The membrane weighs approximately 7.7 pounds per square yard (4.2 kg/m 2 ). 3.2.4 : is a 0.1-inchthick (3.6 mm), granular-surfaced, reinforced, modified bitumen roofing membrane manufactured from a nonwoven polyester fabric impregnated and covered with SBS modified bitumen. The membrane weighs approximately 7.7 pounds per square yard (4.2 kg/m 2 ). 3.2.5 Self-Adhering SBS Modified Base Sheet: The 61-mil thick [0.061-inch (1.55 mm)] base sheet is a flexible, fiberglass-reinforced, self-adhering, rubberized asphalt sheet membrane with a polymer film on the top surface and a removable treated release film on the bottom adhesive side. 3.2.6 Self-Adhering SBS Modified Cap Sheet: The 142-mil-thick [0.142-inch (3.61 mm) cap sheet is a lightweight, flexible, dual-coated, SBS modified sheet membrane consisting of a nonwoven polyester mat with a self-adhering bottom adhesive side protected with a split removable release film and a top surface coated with ceramic granules for protection from ultraviolet degradation. 3.3 Insulation: Foam plastic insulation, where used, must have a flamespread index of not more than 75 when tested, at the maximum thickness intended for use, in accordance with ASTM E 84. See Tables 1 and 2 for insulation types and thicknesses permitted for use with specific roofing systems. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2011 Page 1 of 6 1000

ESR-1013 Most Widely Accepted and Trusted Page 2 of 6 3.4 Fasteners: Fasteners and plates used to mechanically fasten insulation and base sheets must be in accordance with Table 2, unless otherwise noted. 3.5 Impact Resistance: The TAMKO modified bitumen roof coverings described in this report meet the requirement for impact resistance in accordance with FM 4470. 4.0 INSTALLATION 4.1 General: Installation of the TAMKO membrane roof covering systems described in this report must comply with the applicable code, the manufacturer s published installation instructions and this report. The manufacturer s published installation instructions must be available at all times on the jobsite during installation. TAMKO roofing membranes are components of roof covering systems that may be installed over new or existing roofs as described in Tables 1 and 2. The roof slope must be a minimum of (2 percent slope) and must not be more than the maximum slope for the particular system as specified in Table 1. Penetrations and terminations of the roof covering must be flashed and made weathertight in accordance with the TAMKO Building Products, Inc., published installation instructions and the applicable code. 4.2 Fire Classification: 4.2.1 New Construction: Roof covering systems described in Table 1, when installed in accordance with this report, are Class A, B or C roof coverings in accordance with ASTM E 108 or UL 790. 4.2.2 Reroofing: Prior to installation of new roof coverings, inspection in accordance with IBC Section 1510, IRC Section R907 or SBC Section 1510, and approval from the code official having jurisdiction, are required. TAMKO Class A, B or C roof covering systems may be installed over existing roof coverings without additional roof classification tests, provided the resulting classification is the lower of the new and existing roofing classifications under the following conditions: New uninsulated systems installed only over existing uninsulated systems. New insulated systems installed over existing uninsulated systems only. 4.3 Wind Uplift Resistance: 4.3.1 New Construction: The TAMKO membrane roof covering systems described in this report have a maximum allowable wind uplift capacity as shown in Table 2. Metal edge securement for all systems must be designed in accordance with ANSI/SPRI ES-1, complying with IBC Section 1504.5. 4.3.2 Reroofing: Roof covering systems employing mechanical fasteners must be qualified, to the satisfaction of the code official, on adequacy of fasteners penetrating through existing roof coverings into structural substrates. Reroofing with TAMKO adhered systems is outside the scope of this report. 5.0 CONDITIONS OF USE The TAMKO membrane roof covering systems described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with the applicable code, the manufacturer s published installation instructions and this report. The instructions within this report govern if there are any conflicts between the manufacturer s published installation instructions and this report. 5.2 The roof covering systems must be installed only by authorized applicators approved by TAMKO Building Products, Inc. 5.3 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier in accordance with IBC Section 2603.4.1.5, IRC Section R314.1.2 or SBC Section 2603.5.1.5, as applicable, except when specifically recognized in an ICC-ES evaluation report as outlined in Footnote 3 of Table 1. 5.4 Foam plastic insulation, where used, must bear the label of an approved testing and listing agency indicating that the foam plastic has a flame-spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E 84. Total thickness of foam plastic insulation must be limited to the lesser of the maximum thickness allowed in Tables 1 and 2 or the maximum thickness that limits the flame-spread index to not more than 75 when tested in accordance with ASTM E 84. 5.5 Design wind uplift pressure on any roof area, including edge and corner zones, must not exceed the allowable wind uplift pressure for the roof covering installed in that particular area. Refer to allowable wind uplift pressure shown in Table 2. 5.6 The allowable wind-uplift pressures shown in Table 2 are for the roof covering only. The deck and framing to which the roof covering is attached must be designed for the applicable components and cladding wind loads in accordance with the applicable code. 5.7 Calculations demonstrating that the required wind resistance is less than the allowable wind resistance must be submitted to the code official for approval. 5.8 When application is over existing roofs, documentation of the wind-uplift resistance of the composite roof construction must be submitted to the code official. 5.9 The membranes are manufactured in Joplin, Missouri, under a quality control program with inspections by Underwriters Laboratories Inc. (AA-668). 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Membrane Roof-covering Systems (AC75), dated April 2007. 7.0 IDENTIFICATION Each roll of TAMKO roofing membrane covered by this report is labeled with the TAMKO Building Products, Inc., name and address, product name, date code, evaluation report number (ESR-1013) and the name of the inspection agency (Underwriters Laboratories Inc.).

ESR-1013 Most Widely Accepted and Trusted Page 3 of 6 SYSTEM NO. DECK 5 CLASS MAXIMUM ROOF SLOPE 1 NC A 3 / 4 :12 2 NC A 1:12 3 C A 4 C A 5 C A 6 C B 7 C B 8 C B 1:12 9 C B 10 C B 11 C B 12 NC C 1 / 2 :12 1 / 2 :12 TABLE 1 EXTERNAL ROOF FIRE CLASSIFICATIONS 1,6 INSULATION/ THICKNESS 2,3,7 Perlite, glass fiber, wood fiber, urethane, or polystyrene, any thickness Perlite, glass fiber, wood fiber, polyisocyanuarte, urethane or polystyrene, any thickness Perlite, glass fiber or wood thick (Optional) Fiber glass or foam glass, any thickness Perlite or wood fiber, minimum of 1 inch thick (Optional) Glass fiber or foam glass, any thickness Perlite, wood fiber or glass thick Perlite, wood fiber or glass thick Perlite, wood fiber or glass thick Polystyrene, minimum of 1 inch thick (MA), and perlite or wood fiber, minimum of 1 inch thick (MA) (Optional) Glass fiber or perlite, any thickness (MA) (Optional) Perlite, glass fiber, wood fiber, phenolic, urethane, polystyrene; any combination any thickness ROOF COVER Base Sheet 4 Ply Sheet 4 Membrane of Tam- Glass Premium, Tam-Ply, Vapor-Chan, Glass-Base, 43 lb. Base Sheet, Vent-Ply, Smooth FR, or Versa Base of Versa-Base FR of Versa-Base Versa-Base FR Versa-Base FR Tam-Cap (inverted) or Vapor-Chan Tam-Cap (inverted) or Vapor-Chan of Versa-Base of Tam- Glass Premium, Tam-Ply IV, Vapor-Chan, Glass-Base, 43 lb. Base Sheet or Versa- Base of Versa-Base of Glass-Base; or (MA) of Tam- Glass Premium, Tam-Ply IV, Vapor-Chan, Glass Base, 43 lb. Base sheet, Vent-Ply or Awaflex Premium Premium FR or FR or FR or FR or FR or FR or FR or FR or FR or FR or FR or or Awaplan 170 13 C C 1:12 N/A SA Base SA Cap For SI: 1 inch = 25.4 mm. 1 Vapor barriers, insulation, base sheets, ply sheets and membranes must be UL classified for roofing systems. 2 Foam plastic insulation thickness is limited to the lesser of the maximum thickness specified in this table or the maximum thickness stated on the label, that limits the flame spread index to not more than 75 when tested in accordance with ASTM E 84. 3 Foam plastic insulation may be installed over a steel deck without a thermal barrier when installed in accordance with an ICC-ES evaluation report recognizing direct application of a specific foam plastic insulation. Reference 2006 IBC, Section 2603.4.1.5. 4 Type G1 and Type G2 relates to any UL classified fiberglass-reinforced ply or base sheet, respectively, complying with UL 55A. 5 Combustible (C) wood decks must be minimum 15 / 32 -inch-thick (11.9 mm) APA rated plywood; 7 / 16 -inch-thick (11.1 mm) nonveneer APA rated oriented strand board; or 3 / 4 -inch-thick (19 mm) sheathing boards. Noncombustible (NC) steel decks must be minimum No. 22 galvanized steel [0.030 inch (0.76 mm)]. Noncombustible (NC) concrete decks must have a minimum compressive strength (f c ) of 2,500 psi. See Section 5.7 of this report. 6 Abbreviations: (C) Combustible (NC) Noncombustible (MA) Mechanically attached Hot mopped with hot roofing asphalt conforming to ASTM D 312, Type III or IV. Hot mopping is full coverage of hot roofing asphalt at the rate of 20 to 25 pounds per 100 square feet. 7 Roof insulations must comply with the applicable material standards specified in IBC Table 1508.2 or IRC Table R906.2.

ESR-1013 Most Widely Accepted and Trusted Page 4 of 6 SYSTEM NO. 1 2 3 4 5 SUBSTRATE APA rated plywood, min. 15 / 32 -inch-thick (11.9 mm) 6 Gypsum 7 8 9 10 11 Insulating concrete (cellular, vermiculite or perlite) ANCHOR SHEET OR THERMAL BARRIER 1 Thermal barrier - 5 / 8 - inch-thick gypsum board (MA) Anchor sheet of Base-N-Ply or Vapor- Chan (MA) Thermal barrier - 5 / 8 - inch-thick gypsum board (MA) Anchor sheet of Glass-Base, Vapor-Chan or Base-N- Ply (MA) Anchor sheet of Glass-Base, Vapor-Chan or Base-N- Ply (MA) TABLE 2 WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT 3 INSULATION 1,2,4 COVERBOARD ROOF COVER ALLOWABLE UPLIFT Base Sheet Ply Sheet Membrane or CAPACITY Coating (psf) thickness, glassfaced glass, wood fiber or perlite min. 1.3 inches thick thickness, glass fiber glass, wood fiber or perlite min. 1.3 inches thick (MA) min. 1.5 inches thick, min. 1.0 pcf density thickness, glassfaced glass, wood fiber, or perlite thickness, glassfaced glass, wood fiber, or perlite min. 1.3 inches thick (MA) perlite (MA) perlite (MA) perlite (MA) Min. 1 / 2 -inch-thick high-density wood fiber or perlite board Min. 1 / 2 -inch-thick high-density wood fiber or perlite board Min. 1 / 2 -inch-thick high-density wood fiber board 30, Versa-Base, Versa-Smooth or Base-N-Ply 30, Versa-Base, Versa-Smooth or Base-N-Ply 15 or Type 30 30, Versa-Base or Versa-Smooth 30, Versa-Base or Versa-Smooth 15 or Type 30 15 or Type 30 30, Versa-Base or Versa-Smooth (SM) Base or Versa- Base Premium One or two or three IV or Premium (Continued) 15 or Type 30 15 or Type 30 15 or Type 30 15 or Type 30 Premium FR or FR FR FR 80 60 55 52

ESR-1013 Most Widely Accepted and Trusted Page 5 of 6 TABLE 2 WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT 3 (Continued) SYSTEM NO. 12 13 14 15 16 17 18 19 20 21 22 SUBSTRATE ANCHOR SHEET OR THERMAL BARRIER 1 INSULATION 1,2,4 COVERBOARD ROOF COVER ALLOWABLE Base Sheet Ply Sheet Membrane or UPLIFT Coating CAPACITY (psf) perlite roof perlite roof perlite roof wood fiberboard roof wood fiberboard roof Base or Versa- Base Premium One, two or three IV or Premium Bass or Versa- Base One layer of Tam- Ply IV or Tam- Glass Premium Base or Versa- Base Premium One, two or three IV or Premium Base or Versa- Base Premium One, two or three IV or Premium FR FR FR FR FR FR FR FR FR FR FR 23 24 Plywood 15 / 32 In thick Plywood 15 /32 In thick For SI: 1 inch = 25.4 mm. N/A N/A N/A SA Base 5 SA Cap N/A N/A N/A SA Base adhered to asphalt primed deck (Continued) SA Cap 105

ESR-1013 Most Widely Accepted and Trusted Page 6 of 6 TABLE 2 WIND UPLIFT RESISTANCE: METHOD OF ATTACHMENT 3 (Continued) 1 Fasteners for mechanically fastened gypsum board, insulation or anchor sheets must be as follows: Systems 2, 4, 5, 8. Sixteen fasteners per each 4 8 sheet, equally spaced and, positioned in three rows. The outer two rows are located 6 inches from the edge of the 8-foot sides, with the inner row located along the centerline. Six fasteners must be used in each outer row and four fasteners must be used in the center row. Any of the following fastener systems may be used: A. FABCO "System ES" consisting of a No. 13 screw and a 3-inch plastic plate. B. DEKFAST No. 12 or No. 14 stand-off screw with a 2 7 / 8 -inch coated hex-plate, 0.017 inch minimum thickness. C. BUILDEX Hextra screws with Gearlok locking 3-inch-diameter plastic plates or nominally 3-inch-by-3-inch galvanized steel plates identified as Hextra/accutrac plates. D. OLYMPIC No. 12-11 screws with 3 1 / 4 -inch-diameter plastic plates or nominally 3-inch-diameter galvanized steel plates, 0.018 inch minimum thickness. System No. 3. Fasteners for anchor sheet must be spaced along the lap a maximum of 8 inches on center, and two rows (staggered) 16 inches on center located 12 inches from each edge. Fasteners are OLYMPIC No. 12-11 screws with 3-inch-diameter galvanized steel plates, 0.018 inch minimum thickness. System No. 6. Fasteners for anchor sheet must be spaced a maximum of 8 inches on center, and two rows (staggered) 16 inches on center located 12 inches from each edge. Fasteners are Simplex Tube Lok with minimum 2.5-inch-diameter galvanized steel plates, minimum No. 30 MSG. System No. 7. Fasteners for anchor sheet are spaced a maximum of 8 inches on center, and two rows (staggered) 18 inches on center located 12 inches from each edge. Fasteners are ES Products FM-60 fasteners used with FM30 disc or Olympic C-R base ply fastener with minimum 2.5-inch-diameter galvanized steel plates, minimum No. 30 MSG. Systems 9, 10, 11, 12, 13, 14, 15, 16. Roof insulation is fastened with 1 fastener per 2 square feet. Fasteners are Dekfast, Roofgrip, Olympic, or Tru-Fast with metal plates only. Systems 17, 18, 19, 20, 21 and 22. Roof insulation is fastened with one fastener per 2 square feet. Fasteners are Dekfast 14, #15 Dekfast Heavy, Tapcon, Olympic No. 14, or Tru-Fast CF, metal plates only. 2 Foam plastic insulation thickness is limited to the lesser of the maximum thickness specified in this table or the maximum thickness that limits the flame spread index to not more than 75 when tested in accordance with ASTM E 84. 3 Abbreviations: (MA) Mechanically attached Hot mopped with hot roofing asphalt conforming to ASTM D 312, Type III or IV. Hot mopping is full coverage of hot roofing asphalt at the rate of 20 to 25 pounds per 100 square feet. (SM) Spot mopped (System No. 8) with hot roofing asphalt conforming to ASTM D 312, Type III or IV. Spots are nominally 12 inches in diameter spaced nominally 24 inches in all directions. 4 Roof insulations must comply with the applicable material standards 5 System 23 Base Sheet is mechanically attached with 1 1 / 4 -inch-long (32 mm) ring-shank nails with 1-inch-diameter (25.4 mm) metal cap nails spaced 8 inches (203 mm) on center in two evenly spaced staggered rows.