A Disposable On-Chip Phosphate Sensor with Planar Cobalt Microelectrode on Polymer Substrate

Similar documents
A micromachined electrochemical sensor for free chlorine monitoring in drinking water

Bio MEMS Class -1 st week

Laboratory for Sensors, Department of Microsystems Engineering - IMTEK, University of Freiburg, Freiburg, Germany

Design and implementation of a microchemistry analyzer

UNIVERSITY OF CINCINNATI

Electrochemical Sensors

Sensor. Device that converts a non-electrical physical or chemical quantity into an electrical signal. Sensor Processor Display Output signal

Preface Preface to First Edition

Alternative MicroFabrication and Applications in Medicine and Biology

Microfluidics for Electrical Biochip Technology

Interdigitated micro array electrodes with standing nanostructures for micro channel electrochemical biosensors

Wearable Biosensors for Personalized Health Monitoring Wei Gao

Case Studies of Micro-Biosensors

CENTRIFUGAL MICROFLUIDICS

MICROSTRUCTURE-BASED ANALYTICS AND SENSOR TECHNOLOGY

Micro Injection Molding of Micro Fluidic Platform

2.3 Quantum Dots (QDs)

BIOMEMS Microsystems Devices Driving Healthcare Applications. September 2010

Evaluation of a miniaturized thermal biosensor for the determination of glucose in whole blood

Electronic supplementary information

Wearable Sweat Biosensors and Their Biomedical Applications

Polymer Microfabrication (Part II) Prof. Tianhong Cui, Mechanical Engineering ME 8254

MEMS Fabrication. Beyond Integrated Circuits. MEMS Basic Concepts

Silicon and Non-Silicon Materials for BioMEMS Fabrication

Multi Way Biosensors: Development and Commercialization

What is ph? ph is the measurement of the Hydrogen Ion concentration in a particular solution. Indicates the Acidity or Alkalinity of a solution.

High aspect ratio tapered hollow metallic microneedle arrays with microfluidic interconnector

Enhancement of electrochemical biosensor performances using redox cycling at 3D sub-micrometer scale electrode architectures.

Copyright 2008 Year IEEE. Reprinted from IEEE ECTC May 2008, Florida USA.. This material is posted here with permission of the IEEE.

Introduction to BioMEMS

Soft Fabrication and Polymers

Copyright 2009 Year IEEE. Reprinted from IEEE TRANSACTIONS ON ADVANCED PACKAGING. Such permission of the IEEE does not in any way imply IEEE

Red Biosensores Madrid, 13-Febrero-07

MICROFLUIDIC STRUCTURES FOR SINGLE CELL ANALYSIS

FABRICATION OF SWTICHES ON POLYMER-BASED BY HOT EMBOSSING. Chao-Heng Chien, Hui-Min Yu,

Polymer-based Microfabrication

Soft Lithography: MIMIC. Micro Contact Printing. Microtransfer Molding. Soft Lithography: Replica Molding. Soft Lithography.

Recent Advances in Microfluidic Device Applications for Environmental Monitoring and Toxicity Assessments Tae Hyun Yoon

Prototype Microfluidic System for Fluorescence-Based Chemical Sensing

M. Piano 2, R.W. Pittson 3, G.A. Drago 2, S. Serban 3 and J.P.Hart 1

Valveless, Ceramic, Chemical Metering Pumps for Precision Low & Micro-Volume Fluid Control

General Introduction to Microstructure Technology p. 1 What is Microstructure Technology? p. 1 From Microstructure Technology to Microsystems

A MICROFLUDIC APTASENSOR WITH INTEGRATED SAMPLE PRECONCENTRATION, ISOCRATIC ELUTION AND MASS SPECTROMETRIC DETECTION

Supplementary Information

Point of Care Anemia Device

Bio-Microelectromechanical Systems (Bio-MEMS) GROUP 6 廖宇鴻陳奕達陳奐晴

Lecture 6. Through-Wafer Interconnect. Agenda: Through-wafer Interconnect Polymer MEMS. Through-Wafer Interconnect -1. Through-Wafer Interconnect -2

NOC. Marine Environmental Micro Sensors. NOC Sensors Development Group. Biogeochemistry: Global impact, hard to measure

Fabrication of Oxygenation Microfluidic Devices for Cell Cultures

Lab on a chip fotònics i electroquímics

Fabrication of Oxygenation Microfluidic Devices for Cell Cultures

Understanding Biosensors

YSI 2900 Series Biochemistry Analyzers BIOPROCESS FOOD & BEVERAGE BIOFUELS MEDICAL RESEARCH

High precise welding of transparent polymers

Biosensor System-on-a-chip including CMOS-based Signal Processors and 64 Carbon Nanotube-based Sensors for the Detection of a Neurotransmitter

Microfluidics is increasingly being used to scale down and automate laboratory procedures in the

Wang Chu Chien-Wen Research Presentation. By: Tae-Hyung Kang September 6th, 2013

OSTE polymers create novel opportunities in biomedical microsystems Tommy Haraldsson

Fabricating Microfluidic Devices for High-Density Biological Assays

Supplementary Figure S1. CV curves of gold wire and seamless solid/nanoporous Au electrodes in 0.5 M H 2 SO 4 solution at a scan rate of 100 mv S -1.

Supporting Information: Model Based Design of a Microfluidic. Mixer Driven by Induced Charge Electroosmosis

A Lab-on-Chip System for direct SNP sensing from human blood

Thin-film double metal single-electrodes

Using PDMS Micro-Transfer Moulding for Polymer Flip Chip Packaging on MEMS

FABRICATION OF MICROFLUIDIC CHANNELS USING MICROFIBERS FOR APPLICATIONS IN BIOTECHNOLOGY

Analysis of pressure-driven air bubble elimination in a. microfluidic device

MEMSAND MICROSYSTEMS Design, Manufacture, and Nanoscale Engineering

Lactate Thick-Film Screen Printed Biosensor. SAFEGARD: Sensor Arrays for Environmental,

PCR thermal management in an integrated Lab on Chip

Chapter 12 Respiration

BioMEMS for Future Drug Discovery Needs

Microchip Electrophoresis for Glycoprotein Separation. Analytical Strategy, September 30th, 2014 Karina Hasler & Adrian Müller

ME 141B: The MEMS Class Introduction to MEMS and MEMS Design. Sumita Pennathur UCSB

Wireless implantable chip with integrated Nitinol-based pump for radio-controlled local drug delivery

Special Lecture Series Biosensors and Instrumentation

Micro Fabrication : Soft Lithography

Ostemer 322 Crystal Clear

DNA Transformation via Local Heat Shock

Focusing of mammalian cells under an ultrahigh ph gradient created by unidirectional

Figure SI-1. Fabrication process of the microchip. (A) Heater and sensor. 1) Au/Cr

Application Microfluidic Cell Analysis Devices (I) Date: 2013/05/24. Dr. Yi-Chung Tung

Development of microsensors for chloride concentration in concrete

Lab-on-a-chip miniaturized online liquid chromatography

Providing Technical Solutions for Biological Processes and Medical Devices

An Integrated Microfluidic Device for the Continuous Sampling and Analysis of Biological Fluids

Electrochemical Phosphate Sensor

Change in stoichiometry

NanoFabrication Systems DPN. Nanofabrication Systems. A complete line of instruments and tools for micro and nanopatterning applications

Supporting Information

Supplementary Information

Design, Simulation and Study of MEMS Based Micro-needles and Micro-pump for Biomedical Applications

Spying on Cells: Cellular and Subcellular Analysis using Novel Polymeric Micro- and Nanostructures. Xin Zhang Associate Professor.

ELECTROCHEMICAL PROTEIN CLEAVAGE IN A MICROFLUIDIC CELL WITH INTEGRATED BORON DOPED DIAMOND ELECTRODES

"Beyond Silicon," Feature Article, July beyond silicon

Analytical Chemistry

Supporting Information for. Co-Fabrication of Electromagnets and Microfluidic Systems. in Poly(dimethylsiloxane)

Vacuum casting, a new answer for manufacturing biomicrosystems

Portable Biomedical Diagnostic Inspection System using BioCMOS technology

Single drop Whole Blood Diagnostics: Portable Biomedical Sensor for cardiac. Troponin I detection

Better Living Through Biosensors

Transcription:

A Disposable On-Chip Phosphate Sensor with Planar Cobalt Microelectrode on Polymer Substrate Zhiwei Zou,, Jungyoup Han, Am Jang*, Paul L. Bishop*, and Chong H. Ahn MicroSystems and BioMEMS Lab Department of Electrical and Computer Engineering and Computer ScienceS *Department of Civil and Environment Engineering, Cincinnati, OH 45221-0030, USA

Outline Introduction Device Concept and Design Fabrication Experiment Results Conclusions

Introduction Environment Phosphate is the major source of eutrophication of rivers and lakes. Agriculture Phosphate is an essential nutrient for all plants; phosphate fertilizer has been extensively used. Clinical diagnostics Phosphate concentration in human body is directly related to the diagnosis of several diseases.

Introduction Spectrophotometry Atomic Emission Spectrometry Standard phosphate measurement methods High accuracy Expensive instrument and long analysis time

Research Motivation Environmental applications Large scale field deployment Mass data collection Clinical applications Single-use and disposable Rapid detection Miniaturized Inexpensive Simplified Accurate Rapid

Enzyme materials Previous Approach Enzyme Based Biosensors Alkaline phosphatase, pyruvate oxidase, maltose phosphorylase, et al. Advantages High selectivity and sensitivity Limitations Enzyme materials are relative expensive and unstable. The sensor structure is relative complicated. H. Nakamura, M. Hasegawa, Y. Nomura, Y. Arikawa, R. Matsukawa, K. Ikebukuro, and I. Karube, Development of A Highly Sensitive Chemiluminescence Flow-Injection Analysis Sensor for Phosphate-Ion Detection using Maltose Phosphorylase, Journal of Biotechnology, Vol. 75, pp. 127-133, 1999.

Previous Approach Cobalt-Wire Electrode Xiao et al., (1995) first introduced cobalt metal as a phosphate-sensitive electrode material. Simplicity They showed that the metallic Co-wire has a selective potential response toward dihydrogen phosphate (H 2 PO 4-1 ) in the aqueous medium. Selectivity Sensitivity

Previous Approach Cobalt-Wire Electrode

Previous Work Microfabricated On-Chip Biosensors on Polymer Substrate Glucose permeable membrane Immobilized glucose oxidase Lactate Sensor Oxygen Sensor Glucose Sensor R OH 0.7 V R O + H + + e - Reference electrode Counter electrode RE Tyrosine WE Tyrosyl CE Glucose, lactate, and po 2 sensors e - CE RE M n+ M M M n+ 200 μm RE WE Hg CE Mercury droplet WE Insulin sensor Heavy metal ion sensor C. Gao, H.L.R. Rilo, P. Myneni, and C.H. Ahn, A New On-Chip Insulin Biosensor for Monitoring Dynamic Response of Human Islet Cells, Proceedings of the 8th International Conference on Miniaturized Systems in Chemistry and Life Sciences (microtas 2004), Malmo, Sweden, Sep. 26-30, 2004 X. Zhu, C. Gao, J.-W. Choi, P.L. Bishop, and C.H. Ahn, On-Chip Generated Mercury Microelectrode for Heavy Metal Ion Detection, Lab on a Chip, Vol. 5, pp. 212-217, 2005.

Previous Work Polymer Lab-on on-a-chip Cell Monitoring Chemical/Culture media loading channel Cultured Islet Cells On-Chip Insulin Biosensor Glucose Consumption 1 0.8 0.6 0.4 0.2 0 1 2 3 4 5 6 Days Unhealthy Cell Healthy Cell On-Chip Glucose Biosensor PDMS microfluidic system Islet Filtering pillars Captured islet Peak Current /na 1200 1000 800 600 400 200 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Insulin Concentrations /um C. Gao, H.L.R. Rilo, P. Myneni, and C.H. Ahn, A New On-Chip Insulin Biosensor for Monitoring Dynamic Response of Human Islet Cells, Proceedings of the 8th International Conference on Miniaturized Systems in Chemistry and Life Sciences (microtas 2004), Malmo, Sweden, Sep. 26-30, 2004

Previous Work Polymer Lab-on on-a-chip Clinical Diagnostics Pouch Integration of pouch Calibration pouch Waste chamber Biosensor array 150 um POLYMER SUBSTRATE Biochemical sensor Optical transparency Biocompatibility Spray and screen printing Mass production Very low cost AIBN Pressure source Screen printing 200 um sproms (passive valve) Solid-propellant (AIBN) Microneedle Lateral metallic Integration of Metal needle microneedle AIBN heater Mold injection Rapid injection molding Techniques for MASS-PRODUCTION Cyclic Olefin Copolymer (COC) C.H. Ahn, J.-W. Choi, G. Beaucage, J. Nevin, J.-B. Lee, A. Puntambekar, and J.Y. Lee, "Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics" Proceedings of the IEEE, Special Issue on Biomedical Applications for MEMS and Microfluidics, Vol. 92, pp. 154-173, 2004.

Research Objectives Miniaturized on-chip phosphate sensor using planar cobalt microelectrodes on polymer substrate Measurement of both inorganic and organic phosphate in aqueous solutions Integrated with polymer microfluidic system to achieve disposable lab-on-a-chips Benefits Low cost, mass production, less analyte consumption, rapid detection, easy-to-use, long storage time, et al. High sensitivity and selectivity

Device Concept and Design Microfluidic chip Sensing chip Integrated biochip Electric contact

Device Concept and Design Microfluidic chip Inlet Outlet Sensing chip Automatic Pump-33 fluidic dual syringe system pump using micro-pump and micro-vales

Device Concept and Design Microfluidic chip O 2 O 2 P O 2 P Ag/AgCl Au E R 3CoO+2H 2 PO 4- +2H + Co 3 (PO 4 ) 2 +3H 2 O 2Co+O 2 2CoO P Co Au E W O 2 P Sensing chip Model 215 bench-top ph/mv meter BalanceTalk SL TM software

Fabrication Process Sensing Chip Ni COC Au Co S1818 SU-8 SU-8 patterning Au/Co evaporation and patterning Ni electroplating Co etching and patterning SU-8 removal Au etching Injection molding Ag/AgCl electroplating Standard microfabrication technology

Fabrication Process Microfluidic Chip Ni COC Au Co S1818 SU-8 SU-8 patterning Au/Co evaporation and patterning Ni electroplating Co etching and patterning SU-8 removal Au etching Injection molding Injection Mold process Ag/AgCl electroplating High throughput plastic micromachining

Fabrication Process Chip Bonding Ni COC Au Co S1818 SU-8 SU-8 patterning Au/Co evaporation and patterning Ni electroplating Co etching and patterning SU-8 removal Au etching Injection molding Ag/AgCl electroplating UV adhesive bonding

@ Fabricated Device WE WE Co Inlet Microchamber RE Ag/AgCl RE 500 µm Chip size: 1.5 cm 2 cm Electric contact Chamber volume: 2 µl Electrode: 200 µm 1.5 mm Outlet

Experiment Results Output potential vs. various KH 2 PO 4 concentrations -500-660 -550-680 Potential (mv) -600-650 -700-750 10-5 M 10-4 M 10-3 M Potential (mv) -700-720 -740-760 -780-800 10-2 M 0 100 200 300 400 500 Time (sec) -800-5 -4-3 -2 log [Concentration (M)] KH 2 PO 4 has been diluted to different concentrations using buffer solution. The buffer solution was made by potassium hydrogen phthalate (KHP) and KCl in de-ionized water at ph 5.0.

Experiment Results Time-dependent potential response in 10-5 M KH 2 PO 4 0-200 Potential (mv) -400-600 -800 0 5 10 15 20 25 30 35 Time (min) The proposed on-chip sensor presents a steady-state response for more than 30 minutes in 10-5 M KH 2 PO 4 solution, which is sufficient for disposable sensor applications.

Experiment Results Output potential vs. various organic phosphate concentrations -450-450 -480-480 Potential (mv) -510-540 -570-600 -630 Potential (mv) -510-540 -570-600 -630-660 -5-4 -3-2 log[concentration (M)] -660-5 -4-3 -2 log[concentration (M)] Adenosine 5'-triphosphate (ATP) Adenosine 5'-diphosphate (ADP) ATP and ADP have been diluted to different concentrations using buffer solution. The buffer solution was made by potassium hydrogen phthalate (KHP) and KCl in de-ionized water at ph 5.0.

Experiment Results Reproducibility of the fabricated sensor -700-600 RSD = 0.6% -1000 RSD = 2.5% and 2.1% KH 2 PO 4 ATP Potential (mv) -500-400 -300-200 -100 Potential (mv) -800-600 -400-200 0 0 2 4 6 8 10 Number of injection 0 1 2 3 4 Sensor number Potential responses to ten times repeated injections of 10-3 M ADP to the same phosphate sensor Chip-to-chip deviation of four different phosphate sensors in measuring 10-3 M KH 2 PO 4 and 10-3 M ATP

Conclusions Anew on-chip phosphate sensor using planar cobalt micro electrodes has been designed and fabricated. The feasibility of using the proposed sensor to monitor both inorganic and organic phosphate has been presented. Can be quickly fabricated with low cost and high yield compared to the bulk cobalt-wire based phosphate sensor, while still keeping the good performance. Fully integrated with polymer microfluidic system and can be easy developed as multi-analyte polymer lab-on-a-chips. Especially suitable for the large-scale field deployment for mass environmental data collections and disposable point-ofcare testing (POCT) in clinical diagnostics.

Acknowledgements Financial support NIH-P021-L684 Technical assistance Mr. Ron Flenniken Institute for Nanoscale Science and Technology (INST) at the