Seismic behaviour of HSC beam-column joints with high-yield strength steel reinforcement

Similar documents
EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

Beam-column joint tests with grade 500E reinforcing

Hybrid-steel concrete connections under reversed cyclic loadings

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

Seismic Behavior of Low Strength RC Columns with Corroded Plain Reinforcing Bars

Experimental Evaluation of The Seismic Behavior of Steel- Braced RC Frames

Truss Analysis for Evaluating the Behavior of Reinforced Concrete Moment-Resisting Frames with Poorly Reinforcing Details

Experimental study on the seismic performance of RC moment resisting frames with precast-prestressed floor units.

EFFECTS OF INTERACTION BETWEEN JOINT SHEAR AND BOND STRENGTH ON THE ELAST-PLASTIC BEHAVIOR OF R/C BEAM-COLUMN JOINTS

Using High-Strength Self-Compacting Concrete in Reinforced Concrete Beam-Column Joints

TESTS ON AN INTERIOR REINFORCED CONCRETE BEAM-COLUMN JOINT. R. Park*, L. Gaerty**, and E.C. Stevenson***

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

SEISMIC BEHAVIOR OF RC COLUMNS WITH VARIOUS TIE CONFIGURATIONS

EXPERIMENTAL RESULTS

SEISMIC RESPONSE OF LINEAR, FLANGED, AND CONFINED MASONRY SHEAR WALLS

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF INTERIOR JOINTS OF PRECAST PRESTRESSED CONCRETE FRAMES

An Overview of Research at HKU on HSRC Columns and Beam- Column Joints for Low-Medium Seismic-Risked Regions

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

Southeast University, Nanjing, Jiangsu , China. *Corresponding author

SEISMIC RESPONSE OF END-CONFINED REINFORCED CONCRETE BLOCK SHEAR WALLS

INHERENT DUCTILITY OF REINFORCED CONCRETE SHEAR WALLS WITH NON-SEISMIC DETAILING

BOND STRENGTH OF REINFORCED CONCRETE-BEAM COLUMN JOINTS INCORPORATING 500 MPA REINFORCEMENT

SHEAR STRENGTH CAPACITY OF PRESTRESSED CONCRETE BEAM- COLUMN JOINT FOCUSING ON TENDON ANCHORAGE LOCATION

Modelling of RC moment resisting frames with precast-prestressed flooring system

CAUSES OF ELONGATION IN REINFORCED CONCRETE BEAMS SUBJECTED TO CYCLIC LOADING

In-plane testing of precast concrete wall panels with grouted sleeve

BEHAVIOR OF FULL-SCALE SHEAR DEFICIENT CORNER RC BEAM-COLUMN CONNECTIONS RETROFITTED WITH CFRP SHEETS

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Masonry infills with window openings and influence on reinforced concrete frame constructions

Joint. investigation and. partially confined. techniques. jacketing. in the overall frame 2008) enlargement proposed method not.

BEHAVIOUR OF FRP REINFORCED CONCRETE UNDER SIMULATED SEISMIC LOADING

Seismic performance of RC frames with concentric internal steel bracing

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

EXPERIMENTAL INVESTIGATION OF PRECAST CONCRETE BEAM TO COLUMN CONNECTIONS SUBJECTED TO REVERSED CYCLIC LOADS

Effect of beam dimensions on structural performance of wide beam-column joints

Experimental Investigation of RC Beam Column Joint Strengthening

REHABILITATION OF NONDUCTILE BEAM-COLUMN JOINT USING CONCRETE JACKETING

PERFORMANCE OF EXTERIOR PRECAST UNDER CYCLIC LOADING. R. Vidjeapriya & K.P. Jaya Anna University, Chennai , India 1.

IDEA OF HYBRID COLUMN WITH ENERGY ABSORPTION ELEMENT

Ductile moment-resisting connections in glulam beams

CTBUH Technical Paper

CYCLIC BEHAVIOR OF SLENDER R/C COLUMNS WITH INSUFFICIENT LAP SPLICE LENGTH

composite elements, lateral loads, strain analysis, behavior Composite steel concrete elements made by steel and concrete are used in world wide almos

EFFECTS OF END REGION CONFINEMENT ON SEISMIC PERFORMANCE OF RC CANTILEVER WALLS

A F.E.M. MODEL FOR THE EVALUATION OF THE SEISMIC BEHAVIOR OF INTERNAL JOINTS IN REINFORCED CONCRETE FRAMES.

Damage Assessment of Reinforced Concrete Columns Under High Axial Loading

EVALUATION OF SEISMIC PERFORMANCE OF SLENDER L- SHAPED AND T-SHAPED RC STRUCTURAL WALLS

INELASTIC SEISMIC PERFORMANCE OF RC TALL PIERS WITH HOLLOW SECTION

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

SEISMIC RETROFIT OF BEAM-COLUMN JOINTS WITH FRP SHEETS

ABC-UTC. Research Progress Report (Feasibility Study) Title: Alternative ABC Connections Utilizing UHPC. March, 2017

Earthquake-Resistant Coupling Beams without Diagonal Reinforcement

SEISMIC PERFORMANCE OF BRIDGE SLAB-COLUMN JOINTS WITH HEADED REINFORCEMENT

CYCLIC BEHAVIOR OF AN INNOVATIVE STEEL SHEAR WALL SYSTEM

1. INTRODUCTION. Fig.1 Dimension of test specimen

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE COLUMNS UNDER CONSTANT AND VARIABLE AXIAL LOADINGS

Investigation on Behaviour of Reinforced Concrete Beam Column Joints Retrofitted with FRP Wrapping

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

NON-LINEAR FEM ANALYSIS FOR CES SHEAR WALLS

Australian Journal of Basic and Applied Sciences

RETROFITTING OF COLUMNS WITH RC JACKETTING AN EXPERIMENTAL BEHAVIOR

Bond Slip of High Relative Rib Area Bars under Cyclic Loading

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

SHEAR BEHAVIOR OF MULTI-STORY RC STRUCTURAL WALLS WITH ECCENTRIC OPENINGS

Seismic behaviors of columns in ordinary and intermediate moment resisting concrete frames

SEISMIC PERFORMANCE OF BRIDGE COLUMNS WITH DOUBLE INTERLOCKING SPIRALS

Pacific Earthquake Engineering Research Center

STRENGTH AND DUCTILITY OF RETROFITTED R/C BUILDING BY MULTI-STORY STEEL-BRACED FRAME SUBJECTED TO TRI-LATERAL EARTHQUAKE LOADING

Seismic Performance of Hollow-core Flooring: the Significance of Negative Bending Moments

Experimental Study on the Behaviour of Plastered Confined Masonry Wall under Lateral Cyclic Load

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

Cyclic Tests on the Internally Braced RC Frames

EXPERIMENTAL STUDY OF THE EFFECT OF REINFORCEMENT STABILITY ON THE CAPACITY OF REINFORCED CONCRETE COLUMNS

Experimental Study on Wall-Frame Connection of Confined Masonry Wall

Reinforced concrete beam-column joints with lap splices under cyclic loading

SEISMIC FORCE RESISTING MECHANISM OF THE MULTI-STORY PRECAST CONCRETE SHEAR WALL SUPPORTED ON PILES

Hybrid System Using Precast Prestressed Frame with Corrugated Steel Panel Damper

GFRP retrofitted RC frames with columns subjected to high axial stresses

RESEARCH ON SEISMIC RETROFIT OF EARTHQUAKE-DAMAGED AND SEISMIC-DEFICIENT STRUCTURES USING FIBRE-REINFORCED POLYMER (FRP) TECHNOLOGY

SEISMIC BEHAVIOR OF RCS BEAM-COLUMN-SLAB SUBASSEMBLIES DESIGNED FOLLOWING A CONNECTION DEFORMATION-BASED CAPACITY DESIGN APPROACH

INFLUENCE OF JOINT REINFORCEMENT ON STRENGTH AND DEFORMATION OF INTERIOR BEAM-COLUMN SUBASSEMBLAGES

APPLICATIONS OF STRESS FIELDS TO ASSESS THE BEHAVIOR AND STRENGTH OF COUPLING BEAMS SUBJECTED TO SEISMIC ACTIONS

DESIGN OF A SHEAR CONNECTOR FOR A NEW SELF-CENTERING WALL SYSTEM

RESPONSE OF R.C. BRIDGE PIERS TO LARGE DEFLECTIION REVERSALS. Higai, T.I, Rizkalla, S.H.2, Saadat, F.3, Ben Omran, H.4

Experimental research on reduced beam section to concrete-filled steel tubular column joints with RC slab

COMPARISON OF RECENT NEW ZEALAND AND UNITED STATES SEISMIC DESIGN PROVISIONS FOR REINFORCED CONCRETE BEAM-COLUMN JOINTS

Analytical Investigation of Seismic Performance of Exterior RC Beam-Column Joints Rehabilitated with New Scheme

High Performance and Efficiency of Joints in Precast Members

An Experimental Study on the Out-Of-Plane Stability of Reinforced Masonry Shear Walls Under In-Plane Reversed Cyclic Loads

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

Effect of reinforcing steel bond on the seismic performance of lightly reinforced concrete walls

SEISMIC-FORCE-RESISTING MECHANISMS OF MULTI-STORY STRUCTURAL WALLS SUPPORTED ON PILES ABSTRACT

SEISMIC RETROFIT OF BEAMS IN BUILDINGS FOR FLEXURE USING CONCRETE JACKETING

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

Hybrid Simulation Based on Finite Element Analysis of a Continuous Gird Bridge with Fiber Reinforced Polymer composition

Transcription:

Proceedings of the Tenth Pacific Conference on Earthquake Engineering Building an Earthquake-Resilient Pacific 6-8 November 215, Sydney, Australia Seismic behaviour of HSC beam-column joints with high-yield strength steel reinforcement P. Alaee Ph.D. Candidate, School of Civil and Environmental Engineering, Nanyang Technological University, Singapore 639798. E-mail: pooya1@e.ntu.edu.sg B. Li Associate Professor, School of Civil and Environmental Engineering, Nanyang Technological University, Singapore 639798. E-mail: cbli@ntu.edu.sg ABSTRACT: The use of high-yield strength steel reinforcement in RC buildings is a common practice nowadays due to its potential benefits, including reduced steel congestion, less quantity of required steel and a shorter construction time. The purpose of the current study is to find out the seismic behaviour of frame structures in the case of using high-strength material. The experimental findings of high-strength concrete (HSC) interior beam-column joints reinforced with high-strength steel longitudinal bars under zero column axial compressive loading are presented in this paper. Four full-scale interior beam-column joints with varying degrees of reinforcement detailing and different combinations of material grades were subjected to quasi-static horizontal cyclic load. Seismic behaviour of the high-strength and normal-strength specimens is compared in terms of lateral loading capacity, failure modes, strain profiles in the beam and column steel reinforcements and curvature distribution in beams. ACI 318 code provisions regarding utilizing high-strength concrete and high-yield strength reinforcements are reviewed and its validity is investigated based on experimental results. 1 INTRODUCTION Coupled with the rapid urbanization and development of the world, we have seen the erection of highrise buildings across the world and the use of high-strength concrete (HSC) in construction has also become more widespread. The definition of high-strength concrete adopted for this study is a workable concrete with the compressive strength of greater than 6 MPa and the age at which this strength is achieved can be more than 28 days. A number of buildings have been constructed utilizing high-strength concrete with the compressive strength ranging from 6 MPa to 11 MPa. The use of high-strength concrete in building structures offers numerous advantages such as achieving greater heights by reducing the mass of the required concrete and by reducing the size of column cross section. The smaller size of cross sections is also economically favourable due to the increase in rentable floor space. Its high modulus of elasticity which will cause a reduction in deflections and creep deformations has also been pointed as one of its prominent strengths. High-strength concrete is also much more resistant to chemical deterioration as it contains high cement content and low water over cement ratio. With the increased utilization of high-strength concrete for different structural components, many have voiced concern over whether the current code provisions are adequate and accurate enough for the design of high-strength concrete members. As a result, some related committees such as a committee of the American Concrete Institute (ACI Committee 363) have worked on the behaviour of highstrength concrete and they have published multiple reports according to their research. Prior to 199, majority of reinforced concrete structures was constructed using steel reinforcement with the yield strength of 42 MPa. The usage of reinforcement with higher yield strength is more attractive in some countries, especially for beam-column joints in special moment resisting frames; and that acted as the driving motivation for researchers to conduct numerous experiments on beamcolumn joints with high-yield strength reinforcement (Lee and Hwang 213; Xin et al. 1992). Paper Number 147

To-date, numerous investigations related to the shear, bond, and anchorage behaviour at the joint core of beam-column joints under seismic loading have been carried out (Hakuto et al. 1995; Kurose et al.1988; Pessiki et al. 199; Alaee et al. 215). In the current study, the structural performance of the specimens constructed with different grade of materials including concrete and steel reinforcement was evaluated. 2 EXPERIMENTAL PROGRAM 2.1 Test program Four specimens with the same dimensions but different reinforcement details and different strengths of materials were prepared as shown in Fig1 for testing typical interior beam-column joints in RC building structures. The specimens were designated as IN8, IH8, IN1 and IH1. The specimens were designed based on the strong column-weak beam requirement and detailing requirements of ACI318-12 and ACI-ASCE Committee 352 report. These four specimens were tested to investigate the possible advantages of using high-yield strength reinforcements incorporated in high-strength concrete material to increase its joint performance. Test results can be compared to previous research on the normal strength concrete (NSC) specimens with normal-strength reinforcements tested in New Zealand and HSC specimens tested by Li and Leong 214. The target concrete compressive strength of the specimens was 8 and 1 MPa. (a)in8 (b)ih8 (c)in1 (d)ih1 Fig. 1. Reinforcement detailing of tested specimens Deformed steel bars of yield strength fy=46mpa and fy=7mpa were utilized as longitudinal reinforcement of beams and columns in normal-strength and high-strength specimens respectively. The transverse reinforcement utilized in beams and columns included R1 mild steel bars with fy=36mpa and fy=8mpa for normal-strength and high-strength specimens. The reinforcing bars were tested under uniaxial tension and the measured parameters of the steel bars are mentioned in Table 1. The reported values of yield strength and ultimate strength of reinforcing bars are the average values of three tested bars. 2

Table. 1. Summary of specimens properties Specimen IN8 IH8 IN1 IH1 Concrete grade (Mpa) 8 8 1 1 Reinforcement Column Reinforcement Joint hoops Top T16(46MPa) T19(7MPa) T16(46MPa) T16(7MPa) Bottom T16(46MPa) T19(7MPa) T16(46MPa) T16(7MPa) Side T25(46MPa) T25(7MPa) T25(46MPa) T25(7MPa) Centre T16(46MPa) T2(46MPa) T16(46MPa) T2(46MPa) 5R1(46MPa) 4R1(7MPa) 5R1(7MPa) 5R1(7MPa) 2.2 Test setup The test setup is shown in Fig 2(a). The bottom of the column is pinned to the strong floor and beam ends are connected to the strong floor using two vertical links which only restrain the beams vertical movements. Each test specimen was subjected to quasi-static reversed cyclic simulated earthquake loading as shown in Fig 2(b). The horizontal loading is applied to the top of the column using a 5KN hydraulic actuator. No axial load was applied to the specimens. Axial Load (-) (+) Displacement Transducer 5 kn Hydaulic Jack Reaction Wall Post Tension Steel (75 kn Each) 3235 Specimen 1635 24 24 Strong Floor (a)test Setup (b) Loading Pattern Fig. 2. Loading apparatus All the test specimens were equipped with numbers of strain gauges and linear displacement transducers (LVDTs) in order to measure strain values in selected points on reinforcing steel bars, and the deformations of different parts of the specimen. Strain gauges were installed on both longitudinal and transverse reinforcements within and around the joint region. LVDTs were used within the joint region to measure flexural and shear deformations, and on top of the column to find the horizontal displacements. As a result of such measurements, hysteresis loop of specimens which shows the relationship between the storey shear and horizontal displacements, and also the strain data can be reported. The mentioned findings are used to analyze the structural behaviour of HSC beam-column joints reinforced with high-strength steel. 3 EXPERIMENTAL RESULTS 3.1 Lateral load-story drift relationship Fig 3 shows the lateral load versus the story drift relationship for the specimens. Story drift was calculated based on the value of horizontal displacement of the column s top divided by the column height and the lateral load value was determined based on the amount of force required to achieve the displacement value in each loading step. In Specimens IN8 and IN1 with normal strength steel reinforcements, the maximum strengths occurred at approximately 2% story drift ratio. However, In Specimens IH8 and IH1 with high-yield strength reinforcements, the maximum lateral loading strengths happened at a larger drift ratio of 2.5%. In Specimens IN8, IH8 and IN1 the load carrying capacity gradually decreased after the maximum strength, while Specimen IH1 showed a higher drift capacity and a higher ductility. Bond-slip of the beam longitudinal bars occurred in the joint panel, which resulted in a pinching load-story drift relationship. It is observed that a severe 3

Storey shear force(kn) Storey shear force(kn) Storey shear force(kn) Storey shear force(kn) pinching effect was observed in Specimens IN8 and IH1 with high-yield strength steel reinforcements. 15 2 1 5 IN8 15 1 5 IH8-5 -1-5 -1-15 -15-15 -1-5 5 1 15 Horizontal displacement(mm) 15-2 -15-1 -5 5 1 15 Horizontal Displacement (mm) 2 1 5 IN1 15 1 5 IH1-5 -5-1 -1-15 -15-15 -1-5 5 1 15 Horizontal displacement(mm) -2-15 -1-5 5 1 15 Horizontal displacement(mm) 3.2 Failure modes Fig. 3. Storey shears versus horizontal displacements It was observed that in Specimens IN8, IN1 and IH1, the damage mode was flexural yielding of beams and the bond-slip of beam flexural bars. However, Specimen IH8 experienced a damage mode of diagonal cracking at the joint which is due to the larger beam bar diameter in this specimen. Concrete crushing occurred at the interface of beam ends and the joint region in all the specimens. Concrete crushing happened in the bottom area of beam ends specifically. The reason is the large compressive stress developed in the bottom part of beams due to the large amount of top reinforcement area in the beam cross section. 3.3 Strain of flexural reinforcing bars in the joint region Fig 4 shows the strains of the beam top and bottom steel bars in the centre of the joint region. The strain value at B6 shows the strain value at the centre of the beam bottom bar while T6 shows the strain value at the centre of top beam bars. The beam top and bottom bars are T16 for Specimens IN8, IN1 and IH1 while T19 was used for Specimen IH8. It was observed that initial yielding happened outside the joint region at fist in all of the specimens and the strain value of the reinforcement within the joint region was always less than its value in the plastic hinge region of the beams. However, it was observed that the strain value in the joint region in Specimen IH8 with large diameter beam bars did not increase significantly due to its bond-slip. It is observed that the strain value of the beam bottom bars is less than that in the beam top bars in Specimens IN8 and IH8 with the concrete grade of 8MPa. This observation clarifies that the bond- 4

slip occurred at the beam bottom bars. 4 3 2 IN8 B6 4 3 2 IN8 T6 4 3 2 IH8 B6 1 1 1-6 -4-2 2 4 6-1 -6-4 -2 2 4 6-1 -6-4 -2 2 4 6-1 4 3 2 IH8 T6 4 3 2 IN1 B6 4 3 2 IN1 T6 1 1 1-6 -4-2 2 4 6-1 -6-4 -2 2 4 6-1 -6-4 -2 2 4 6-1 5 5 4 3 IH1 B6 4 3 IH1 T6 2 2 1 1-6 -4-2 2 4 6-1 -6-4 -2 2 4 6-1 Fig. 4. Strain of beam top and bottom reinforcing bars 3.4 Strain of longitudinal reinforcing bars in the column Fig 5 shows the strains of side bar and central bar of columns in all the specimens.l5 and C5 represent the strain value in the centre of the side bar and the central bar in the column, while L6 and C6 represent the strain value of the column side bar and centre bar in the level of beam bottom bars. Generally the strains increased gradually, although they did not reach the yield strain. From the top beam face to the bottom beam face, the column reinforcement experienced tension. The central column bars experienced lower stress compared to the side column bars in general. The column remained elastic at the end of the test. 4 3 L5 L6 IN8 4 3 C4 C6 IN8 4 3 L5 L6 IH8 2 2 2 1 1 1-6 -4-2 2 4 6-1 -6-4 -2 2 4 6-1 -6-4 -2 2 4 6-1 5

4 3 2 C5 C6 4 L5 4 L6 3 3 2 2 IH8 IN1 IN1 C5 C6 1-6 -4-2 2 4 6-1 1-6 -4-2 2 4 6-1 1-6 -4-2 2 4 6-1 5 4 3 2 1 L5 L6 IH1-6 -4-2 2 4 6-1 4 C5 C6 IH1 3 2 1-6 -4-2 2 4 6-1 Fig. 5. Strain of column reinforcing bars 3.5 Strain of ties Fig 6 shows the strains of the tie bars in the joint region. H1 represents the lowest tie in the joint panel and H3 is the tie in the centre of the joint. The maximum strain value was.12,.14 and.2 in Specimens IN8, IN1 and IH1. The maximum strain was less than the yield strain in all the specimens and no yielding of joint hoops was observed. 4 3 2 H1 H3 IN8 4 3 2 H1 H3 IN1 4 3 2 H1 H3 IH1 1 1 1-6 -4-2 2 4 6-6 -4-2 2 4 6-1 -1 Fig. 6. Strain of tie bars in the joint region -6-4 -2 2 4 6-1 3.6 curvatures Fig 7 shows the beam curvature distributions estimated from the experimental results and instruments readings. Curvature values are presented for drift ratios of DR=1% and DR=3% in the positive and negative loading directions. With the positive beam moment during DR 1%, the beam curvature measured near the column face reached the theoretical yield curvature. Rapid increase of the curvature was observed in the subsequent loading cycles. This was due mainly to the plastic hinges forming in the beam end. A similar situation was also observed in the negative loading cycles. curvature increases rapidly after DR 3%. 6

Curvature φ (rad/m) Curvature φ (rad/m) Curvature φ (rad/m) Curvature φ (rad/m).8.6.4.2 IN8 DR=1.% DR=-1.% DR=3.% DR=-3.%.7.5.3 IH8 DR=1.% DR=-1.% DR=3.% DR=-3.%.1 -.2 -.4 -.6 -.8 -.1 -.3 -.5 -.1 Column -.7 Column.8.6.4.2 IN1 DR=1% DR=-1% DR=3% DR=-3%.8.6.4.2 IH1 DR=1% DR=-1% DR=3% DR=-3% -.2 -.2 -.4 -.4 -.6 -.6 -.8 -.8 -.1 Column -.1 Column Fig. 7. Curvature distribution of the beams 4 CONCLUSIONS A study was carried out on the seismic performance of HSC beam column joints reinforced with highyield strength steel reinforcement. In order to evaluate the structural performance, four interior specimens using grade 8 and 1MPa concrete were designed as part of special moment frame according to the provisions of ACI 318-12 (Building Code Requirements for Structural Concrete) and ACI 352R-2 (Recommendations for Design of -Column Connections in Monolithic Reinforced Concrete Structures) for the seismic design of reinforced concrete structures. The following conclusions are summarized: 1- Utilizing high grade steel reinforcement will improve the load-carrying capacity of the specimens. However, a more pinching hysteresis response is observed, which is due to the bond-slip of the beam top and bottom steel reinforcements. 2- Flexural failure mode in the beam plastic hinge regions was observed at the end of each test which implies the validity of ACI 318-8 code provisions for the design of high strength beam-column joints. 3- The strain profiles of steel reinforcements showed that column rebars and joint hoops remained elastic during the test and yielding occurred in beam top and bottom rebars which is desirable according to the contemporary structural design philosophy. REFERENCES: ACI Committee. 212. Building code requirements for structural concrete (318-12) and commentary-(318r-12). Detroit, Michigan: American Concrete Institute. ACI-ASCE Committee 352 2. Recommendation for design of beam-column connections in monolithic reinforced concrete structures, ACI 352R 2. Detroit, MI: American Concrete Institute; Reapproved 21. Alaee, P., Li, B., & Cheung, P. P. C. (215). Parametric investigation of 3D RC beam column joint mechanics. Magazine of Concrete Research, 67, 154-169. Hakuto S., Park R. and Tanaka H. 1995. Retrofitting of Reinforced Concrete Moment Resisting Frame. Department of Civil Engineering, University of Canterbury, Research Report 95-4, Christchurch, New Zealand, 39 pp. 7

Kurose Y., Guimaraes G.N., Liu Z., Kreger M.E., and Jirsa J.O. 1988. Study of Reinforced Concrete - Column Joints under Uniaxial and Biaxial Loading. PMFSEL Report No. 88-2, Department of Civil Engineering, University of Texas at Austin, December 1988, 146 pp. Lee, H. and Hwang, S. 213. High-Strength Concrete and Reinforcing Steel in -Column Connections Proceeding of ASCE Structures Congress 213: pp. 166-1615 Li, B., & Leong, C. L. 214. Experimental and Numerical Investigations of the Seismic Behavior of High- Strength Concrete -Column Joints with Column Axial Load. Journal of Structural Engineering, 41422. Pessiki, S. P.; Conley, C. H.; Gergely, P.; and White, R. N.; Seismic Behavior of Lightly Reinforced Concrete Column and -Column Joint Details, NCEER Technical Report No. 9-14, State University of New York at Buffalo. Xin, X Z, Park, R.,Tanaka, H. 1992. Behaviour of Reinforced Concrete Interior -Column Joints Designed using High Strength Concrete and Steel, Research report 92-3 University of Canterbury, New Zealand, 121p. 8