ANSI/NEMA WC ICEA S Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy

Similar documents
NEMA Standards Publication No. WC ICEA Publication No. S

ANSI/NEMA WC ICEA S Standard for Control, Thermocouple Extension, and Instrumentation Cables

ANSI/NEMA WC 71 ICEA S Nonshielded Cables Rated V for Use in the Distribution of Electric Energy

Purchase Now ANSI/ICEA S STANDARD FOR 600 VOLT SINGLE LAYER THERMOSET INSULATED UTILITY UNDERGROUND DISTRIBUTION CABLES

ANSI/ICEA T (2014)

NEMA Standards Publication TC Electrical Nonmetallic Tubing (ENT)

For Electrical Intermediate Metal Conduit (EIMC)

ICEA STANDARD FOR DISTRIBUTION FRAME-WIRE TECHNICAL REQUIREMENTS. Published By INSULATED CABLE ENGINEERS ASSOCIATION, INC. Post Office Box 1568

STANDARD FOR CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE.

ANSI C (R2002, R2012) Reaffirmation of ANSI C (R2002) American National Standard. Thermal Demand Meters

NEMA XR Standard Attributes on CT Equipment Related to Dose Optimization and Management

STANDARD FOR. BROADBAND TWISTED PAIR CABLE AIRCORE, POLYOLEFlN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS

American National Standard. Standard for Uninsulated Conductors Used in Electrical and Electronic Applications ANSI/NEMA WC

American National Standard

NORMAS DE REFERENCIA AEIC CS 1: ASTM B

AWS A5.35/A5.35M: 2015-AMD1 An American National Standard. Specification for Covered Electrodes for Underwater Wet Shielded Metal Arc Welding

Purchase Now ANSI/ICEA S

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

INTERNATIONAL STANDARD

AWS D14.3/D14.3M:2010 An American National Standard. Specification for Welding Earthmoving, Construction, and Agricultural Equipment

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for

SPECIFICATION FOR 600 VOLT CONTROL AND POWER CABLE SPECIFICATION NO. 557

NEMA Standards Publication NEMA/MITA 1. Good Refurbishment Practices for Medical Imaging Equipment

NEMA Standards Publication NEMA/MITA 1. Good Refurbishment Practices for Medical Imaging Equipment

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SPECIFICATION FOR FRLS POWER CABLES

INTERNATIONAL STANDARD

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

AWS D10.18M/D10.18:2018 An American National Standard. Guide for Welding Ferritic/Austenitic Duplex Stainless Steel Piping and Tubing

26/35kV Copper XLPE Insulation Electric Cable

AWS G2.1M/G2.1:2012 An American National Standard. Guide for the Joining of Wrought Nickel-Based Alloys

Plastic Pipe Timeline

STANDARD FOR BROADBAND BURIED SERVICE WIRE, FILLED, POLYOLEFIN INSULATED, COPPER CONDUCTOR TECHNICAL REQUIREMENTS. Published By

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

DETAIL SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/

PROForms. Specifications SECTION FIBERGLASS REINFORCED POLYMER (FRP) PULTRUDED PRODUCTS

Gas Tungsten Arc Welding of Aluminum (M/P-22 to M/P-22), 18 through 10 Gauge, ER4043 or R4043, in the As-Welded Condition, with or without Backing

Cold Shrink EPDM Tubes Connector Insulators 8420 Series

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS3SWU (INCLUDING VARIATION LS3SWUS)

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

ES2000 TUBING Environmental Sealing, Polyolefin, Semirigid, Adhesive-Lined

AWS D9.1/D9.1M:2018 An American National Standard. Sheet Metal Welding Code

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

Una e mpre sa Vi akab l e GLOSSARY.

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

SECTION MEDIUM-VOLTAGE CABLES PART 1 GENERAL


Testing of THERMOLIGN Dead-End. For. Prepared by: Robert Whapham Preformed Line Products, Principal Investigator

3M Cold Shrink Joint, SC145-II/SS145-II

3 MODIFICATIONS TO EXISTING STANDARDS

Standard of Practice - Campus Electrical Distribution System

U.V resistance UL Sunlight Resistance. Flame retardant IEC

Industry Guidance on Records Review for Re-affirming Transmission Pipeline MAOPs

AWS D1.4/D1.4M:2018 An American National Standard. Structural Welding Code Steel Reinforcing Bars

PROJECT MANAGEMENT BODY OF KNOWLEDGE

3M Heavy Wall Heat Shrink Tubing ITCSN

*** Supercedes: BECO E and COM , , & ***

CONSTRUCTION SPECIFICATION FOR CABLE INSTALLATION

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE

Linings of Aboveground Petroleum Storage Tank Bottoms API RECOMMENDED PRACTICE 652 FOURTH EDITION, SEPTEMBER 2014

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

Glossary Of Terms M-1

PV Solar Wiring Solutions

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 4

Selection of the Correct Optical Cable Outer Jacket for the Application

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant

Engineering Data for Copper and Aluminum Conductor Electrical Cables

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484.

This document is a preview generated by EVS

catalog Copper Wires

AMENDMENT OF MALAYSIAN STANDARD MALAYSIAN STANDARD MS :2009

15 kv EPR Insulated, Jacketed, URD Cable

CRA Clad or Lined Steel Pipe

Tele-Fonika Cable Americas

Construction guideline

Test Report No.: Page 2 of 35

ISO 6722 INTERNATIONAL STANDARD. Road vehicles 60 V and 600 V single-core cables Dimensions, test methods and requirements

New Conduit Specification

Recommended Practice for Lighting Industrial Facilities ANSI/IES RP-7-17

3M Medium-Wall Heat Shrink Tubing IMCSN

Cables ELE E L CT E C R T R IC I C A A L L

Raychem S1297 and /97 Hot Melt Adhesive

MATERIAL STANDARD FOR CABLES AND WIRES

Liquatite. Flexible Conduit JIC. Steel Core. Type LT

Evaluation Report CCMC R AZEK Deck

Cables for Railway Signalling Applications General Requirements

Transcription:

Approved as an American National Standard ANSI Approval Date: February 23, 2009 ANSI/NEMA WC 70-2009 ICEA S-95-658-2009 Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Published by National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752 Rosslyn, Virginia 22209 www.nema.org Copyright 2009 by the National Electrical Manufacturers Association and the Insulated Cable Engineers Association, Incorporated. All rights, including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions.

NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. The National Electrical Manufacturers Association (NEMA) and the Insulated Cable Engineers Association Inc. (ICEA) standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development process. This process brings together persons who have an interest in the topic covered by this publication. While NEMA and ICEA administers the process and establishes rules to promote fairness in the development of consensus, they do not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA and ICEA disclaims liability for personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA and ICEA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA and ICEA do not undertake to guarantee the performance of any individual manufacturer's or seller s products or services by virtue of this standard or guide. In publishing and making this document available, NEMA and ICEA are not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA and ICEA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not covered by this publication. NEMA and ICEA have no power, nor do they undertake to police or enforce compliance with the contents of this document. NEMA and ICEA do not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with any health or safety-related information in this document shall not be attributable to NEMA and ICEA and is solely the responsibility of the certifier or maker of the statement.

Page i CONTENTS Page FOREWORD... iv Section 1 GENERAL... 1 1.1 SCOPE... 1 1.2 GENERAL INFORMATION... 1 1.3 INFORMATION TO BE SUPPLIED BY PURCHASER... 1 1.3.1 Characteristics of System on Which Cable is to be Used... 1 1.3.2 Quantities and Description of Cable... 2 Section 2 CONDUCTOR... 3 2.0 GENERAL... 3 2.1 PHYSICAL AND ELECTRICAL PROPERTIES... 3 2.1.1 Copper Conductors... 3 2.1.2 Aluminum Conductors... 3 2.1.3 Flexible Conductors... 4 2.2 CONDUCTOR SIZE UNITS... 4 2.3 CONDUCTOR DC RESISTANCE PER UNIT LENGTH... 4 2.3.1 Direct Measurement of dc Resistance... 4 2.3.2 Calculation of dc Resistance per Unit Length... 4 2.4 CONDUCTOR DIAMETER... 5 Section 3 INSULATION... 17 3.1 MATERIAL... 17 3.2 INSULATION LEVELS... 17 3.3 INSULATION THICKNESSES... 17 3.3.1 The Thickness Of Insulation For Various Systems Shall Be Determined As Follows:... 18 3.4 ADDITIONAL INSULATION THICKNESS FOR NON-SHEATHED SUBMARINE CABLES... 18 3.5 REPAIRS... 18 3.6 INSULATION GRADES AND REQUIREMENTS... 18 3.6.1 The Classes Of Insulation And Their General Characteristics Are Given In Table 3-1.... 18 3.6.2 Voltage Tests... 18 3.6.3 Insulation Resistance... 18 Section 4 COVERINGS... 28 4.1 JACKETS... 28 4.1.1 Cross-linked and Thermoplastic Jackets - General... 28 4.1.2 Neoprene, Heavy-duty Black (CR-HD)... 28 4.1.3 Neoprene, General Purpose (CR-GP)... 28 4.1.4 Polyvinyl Chloride (PVC)... 28 4.1.5 Low and Linear Low Density Polyethylene (LDPE & LLDPE)... 28 4.1.6 Medium Density Polyethylene (MDPE)... 28 4.1.7 High Density Polyethylene (HDPE)... 28 4.1.8 Nitrile-Butadiene/Polyvinyl-Chloride, Heavy Duty (NBR/PVC-HD)... 28 4.1.9 Nitrile-butadiene/Polyvinyl-chloride, General-purpose Duty (NBR/PVC-GP)... 29 4.1.10 Chlorosulfonated Polyethylene, Heavy Duty (CSPE-HD)... 29 4.1.11 Chlorinated Polyethylene, Thermoplastic (CPE-TP)... 29 4.1.12 Chlorinated Polyethylene, Cross-Linked, Heavy Duty (CPE-XL-HD)... 29 4.1.13 Low Smoke Halogen Free Jackets... 29 4.1.14 Thermoplastic Elastomer (TPE)... 29 4.1.15 Optional Requirements... 29 4.1.16 Separator Under Jacket... 29 4.1.17 Repairs... 29 4.1.18 Jacket Thickness... 32 4.1.19 Irregularity Inspection of Jackets Over Cable... 33 4.2 METALLIC AND ASSOCIATED COVERINGS... 34

Page ii 4.2.1 General... 34 4.3 DIVISION I... 35 4.3.1 Smooth Metallic Sheaths... 35 4.3.2 Flat Steel Tape Armor... 37 4.3.3 Interlocked Metal Tape Armor... 39 4.3.4 Continuously Corrugated Metal Armor... 40 4.3.5 Galvanized Steel Wire Armor... 41 4.3.6 Bedding Over Cable Cores To Be Metallic Armored... 44 4.3.7 Outer Servings... 45 4.3.8 Cross-linked Jackets Over Metallic Coverings (Sheaths and Armors)... 45 4.3.8.1 Material... 45 4.3.9 Thermoplastic Jackets Over Metallic Coverings (Sheaths or Armors)... 46 4.4 DIVISION II... 47 4.4.1 Borehole Cable (Suspended at One End Only)... 47 4.4.2 Dredge Cable... 48 4.4.3 Shaft Cable... 49 4.4.4 Vertical Riser Cable... 49 4.5 DIVISION III... 50 4.5.1 Buried Land Cables... 50 Section 5 ASSEMBLY, FILLERS, CONDUCTOR IDENTIFICATION, GROUNDING CONDUCTORS AND SHIELDING.... 51 5.1 ASSEMBLY OF MULTIPLE-CONDUCTOR CABLES... 51 5.1.1 Multiple-Conductor Round Cables With An Overall Covering... 51 5.1.2 Multiple-Conductor Assemblies Without Overall Covering... 51 5.1.3 Flat Twin Cables... 52 5.2 FILLERS... 52 5.3 CONDUCTOR IDENTIFICATION... 52 5.4 GROUNDING CONDUCTORS... 52 5.5 SHIELDING... 52 5.5.1 General... 52 5.5.2 Metal Tapes... 53 Section 6 PRODUCTION TESTS AND TEST METHODS... 54 6.1 GENERAL... 54 6.1.1 Testing and Test Frequency... 54 6.1.2 Test Methods... 54 6.1.3 Number of Test Specimens from Samples... 56 6.2 THICKNESS MEASUREMENTS... 56 6.2.1 Beddings and Servings... 56 6.2.2 Other Components... 56 6.3 SAMPLES AND SPECIMENS FOR PHYSICAL AND AGING TESTS... 56 6.3.1 General... 56 6.3.2 Sampling... 56 6.3.3 Size of Test Specimens... 56 6.3.4 Specimens with Jackets... 57 6.3.5 Specimen Surface IrregularitiesError! Bookmark not defined.... 57 6.3.6 Specimens for the Aging Tests... 58 6.3.7 Calculation of Area of Test Specimens... 58 6.4 AGING TESTS... 59 6.4.1 Air Oven Aging Test... 59 6.4.2 Oil Immersion Test... 59 6.5 HEAT SHOCK TEST... 59 6.6 COLD-BEND TEST... 60 6.7 TIGHTNESS OF POLYETHYLENE JACKET TO SHEATH TEST... 60 6.8 HOT CREEP TEST... 60

Page iii 6.9 WRAP TEST FOR NYLON-COVERED INSULATED CONDUCTORS... 60 6.10 ELECTRICAL TESTS ON COMPLETED CABLES... 61 6.10.1 Voltage Tests... 61 6.10.2 Insulation Resistance... 63 6.10.3 Shield Continuity... 63 6.11 RETESTS... 63 6.11.1 Physical and Aging Properties and Thickness... 63 6.11.2 Other Tests... 64 Section 7 QUALIFICATION TESTS... 65 7.0 GENERAL... 65 7.1 ACCELERATED WATER ABSORPTION TEST, ELECTRICAL METHOD AT 60HZ... 65 7.2 Insulation Resistance Test... 65 7.3 TRAY CABLE FLAME TEST... 65 7.4 SUNLIGHT RESISTANCE TEST... 65 7.5 Halogen Content of Non-Metallic Elements... 65 7.6 Smoke generation test... 66 7.7 acid gas equivalent test... 66 7.8 ENVIRONMENTAL STRESS CRACKING TEST... 66 7.9 ABSORPTION COEFFICIENT... 66 7.10 WET INSULATION RESISTANCE STABILITY TEST... 66 Section 8 CONSTRUCTIONS OF SPECIFIC TYPES... 67 8.1 PREASSEMBLED AERIAL CABLES... 67 8.1.1 Scope... 67 8.1.2 Conductors... 67 8.1.3 Insulation... 67 8.1.4 Jacket... 67 8.1.5 Assembly... 67 8.1.6 Messenger... 67 8.1.7 Design Criteria... 67 APPENDICES... 68 APPENDIX A NEMA, ICEA, AND ASTM STANDARDS (Normative)... 68 APPENDIX B DEFINITIONS OF MAXIMUM TEMPERATURES OF INSULATED CABLE CONDUCTORS (Normative)... 71 APPENDIX C EMERGENCY OVERLOADS (Informative)... 72 APPENDIX D ABBREVIATIONS AND SYMBOLS (Informative)... 73 APPENDIX E REPRESENTATIVE TENSILE STRENGTH AND ELONGATION OF NONMAGNETIC METALS (Informative)... 74 APPENDIX F RECOMMENDED BENDING RADII FOR CABLES (Informative)... 75 APPENDIX G ADDITIONAL CONDUCTOR INFORMATION... 77 (Informative)... 77 APPENDIX H PROCEDURE FOR DETERMINING DIMENSIONAL REQUIREMENTS OF JACKETS AND ASSOCIATED COVERINGS (Normative)... 85

Page iv FOREWORD This Standards Publication for Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy was developed by the Insulated Cable Engineers Association (ICEA) and approved by the National Electrical Manufacturers Association (NEMA). ICEA/NEMA Standards are adopted in the public interest and are designed to eliminate misunderstanding between the manufacturer and the user and to assist the user in selecting and obtaining the proper product for his particular need. Existence of an ICEA/NEMA Standard does not in any respect preclude the manufacture or use of products not conforming to the standard. The user of this Standard is cautioned to observe any health or safety regulations and rules relative to the manufacture and use of cable made in conformity with this Standard. Requests for interpretation of this Standard must be submitted in writing to: Insulated Cable Engineers Association, Inc. Post Office Box 1568 Carrollton, Georgia 30112 An official written interpretation will be provided once approved by ICEA and NEMA. Suggestions for improvements gained in the use of this Standard will be welcomed by the Association.

Page 1 Section 1 GENERAL 1.1 SCOPE This standard applies to materials, constructions, and testing of 2000 volts and less thermoplastic, crosslinked polyethylene, and crosslinked rubber insulated wires and cables which are used for the transmission and distribution of electrical energy for normal conditions of installation and service, either indoors, outdoors, aerial, underground, or submarine.