ENERGY EVALUATION BY SIMULATION FOR EFFECTIVE USE OF SEWAGE HEAT

Similar documents
Evaluation of reduced energy use resulting from a DHC network in the Shinjuku DHC area

RETRO-COMMISSIONING OF A HEAT SOURCE SYSTEM IN A DISTRICT HEATING AND COOLING SYSTEM Eikichi Ono 1*, Harunori Yoshida 2, Fulin Wang 3 KEYWORDS

POTENTIAL FOR THE ENERGY EFFICIENCY ADVANCEMENT IN DISTRICT HEATING AND COOLING PLANT BY RENOVATION

COMPUTER SIMULATION AND EXPERIMENTAL VALIDATION OF A MODERN HOTEL ON BUILDING ENERGY CONSERVATION

Tomohiko Ihara *, Yutaka Genchi National Institute of Advanced Industrial Science and Technology, Tsukuba, Ibaraki, Japan

Analysis of Distributed Energy Supplying Technologies From the Viewpoint of Waste Heat

THERMAL CHARACTERISTICS AND ENERGY CONSERVATION MEASURES IN AN INDOOR SPEED-SKATING ARENA

EVALUATION OF DISTRIBUTION SYSTEM PERFORMANCE IN DISTRICT HEATING AND COOLING SYSTEM

EVALUATION OF THE IMPACT OF NEW RESIDENTIAL WATER HEATER DISSEMINATION BY A RESIDENTIAL ENERGY END-USE MODEL

Zero Energy House in Japan: Actual results and future target. Isamu Ohta Misawa Homes Institute of Research & Development CO., LTD.

Modeling and analyzing solar cooling systems in Polysun

Building Commissioning for Energy Efficiency and Comfort, Vol.VI-8-4

ENERGY MANAGEMENT IN A CHILLED WATER PLANT USING THERMAL STORAGE

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

Energy from the Earth. Geothermal Two very different methods Tides, waves, currents. Unit 12 Energy from the earth - Slide 1

Economic Estimation of Heat Storage Type Geothermal Source Heat Pump System Applied in K-Ward Office Building

Coupling of Building Data Analysis and Building Simulation - Case Study in Large-scale Complex Building -

NWC District Energy Campus Energy - RFQ Supporting Documentation. April 25, 2018

Urban Greening and the UHI: Seasonal Trade-offs in Heating and Cooling Energy Consumption in Manchester, UK

CHP Case Studies. Midwest CHP Application Center (MAC) .org (312) University of Illinois at Chicago Energy Resources Center UIC

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

Natural Ventilation System for a School Building Combined with Solar Chimney and Underground Pit

Efficient utilization of energy sources

A PRACTICAL STUDY ON APPLICATION OF COMMISSIONING TO A DHC PLANT DURING THE OPERATION AND MAINTENANCE STAGE

*Corresponding authors. Tel.: x415, address: (N. Zhu)

enables to easily calculate the energy consumption of air conditioning in various conditions (MLIT). In this study, the university building is the obj

Heat Pump Field Trials and Implications for Design

Study on Performance Verification and Evaluation of District Heating and Cooling System Using Thermal Energy of River Water

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

Electric Forward Market Report

OPTIMAL OPERATING METHOD FOR A HEAT SOURCE SYSTEM CONSIST OF CENTRIFUGAL CHILLERS

Passive Strategies and Low-Carbon Technologies: Evaluating the Energy Performance and Thermal Comfort of a Passive House Design

Solar Thermal Optimization for District Hot Water through Energy Modeling

Future European Heat. Renewable heating comparisons

SIMULATION VERSUS REALITY 4 CASE STUDIES. Anthony Calderone Aurecon, Melbourne, Australia

Strategies for energy efficiency improvement in residential and office buildings: their role at building and country scale

IMPROVEMENT IN THE EFFICIENCY OF DISTRICT HEATING AND COOLING (DHC) WITH A REGIONAL STEAM NETWORK OF CHPs AND MUNICIPAL INCINERATION PLANTS IN TOKYO

Explanation of JCM Feasibility Study in Thailand & Applicable Low CO2 Emission Technology

Analysis II Energy Considerations for Green Roofs

A HYBRID MONITORING-MODELING PROCEDURE FOR ANALYZING THE PERFORMANCE OF LARGE CENTRAL CHILLING PLANTS

A survey on energy consumption status and characteristics of hotel buildings in Guangzhou

Comparative Study On Simulation Tools Of Annual Heat Load For Energy Management Y. Takahashi 1 *, G. Yoon 1, M. Yoshinaga 2, and R. Chiba 3 1 Graduate

THE IMPACT OF GLAZING SELECTION ON DAYLIGHTING AND ENERGY PERFORMANCE FOR AN OFFICE BUILDING IN CANBERRA

NORTH AMERICAN MONITORING OF A HOTEL WITH ROOM SIZE GSHPS

Allstream Centre Energy Performance Report

LARGE-SCALE APPLICATION OF MUNICIPAL RECLAIMED WATER SOURCE HEAT PUMPS TO A DHC SYSTEM IN THE BEIJING OLYMPIC VILLAGE

Concentrating solar power in sustainable tourism

Ground-Coupled Heat Pump And Energy Storage

Copyright : 2009, Elsevier Masson SAS

Operation of Swimming Pool Solar Heating at Blackmount School.

The DHP-AQ Air/Water Heat Pump Savings worth celebrating

Sustainable Building Façade and Advanced Fenestration Systems

ENERGY AND WATER CONSERVATION AND DEMAND MANAGEMENT PLAN

OPTIMIZATION OF ICE THERMAL STORAGE SYSTEM DESIGN FOR HVAC SYSTEMS

Case Study: Energy Efficiency and CDM Project in Lao Brewery Co.Ltd,.

Impact of Distributed Solar Generation in Low Energy Housing on the Electrical Grid

National Indian Gaming Association 2005 Certification: Energy Management for Cost Savings Larry Kinney Synertech Systems Corporation On behalf of

Effect of Evaporative Cooling Techniques (Sprayed Water Mist) on Reducing Urban Heat Flux and Saving Energy in an Apartment House

Hot water persons. Map section

Evaluation of Solar PV and Wind Alternatives for Self Renewable Energy Supply: Case Study of Shrimp Cultivation

SolarCity Partnership. Toronto Fire Station # kwt Solar Water Heating Installation. Technology. Monitoring. Best Practices

ENERGY SAVING OF AIR-CONDITIONING IN MASS MERCHANDISERS BY OPERATIONAL CHANGE OF AIR-CONDITIONING SYSTEM

Timmins and District Hospital

Energy Upgrade Screening Study

Condenser Water Heat Recovery"

Energy Audit Summary Report. Manufacture of cosmetics

INTEGRATION OF A NEW CCGT PLANT AND AN EXISTING LNG TERMINAL AT BARCELONA PORT Abstract ID Number: 155

362: Indoor climate control effect of AAC panels as determined by house model measurements and simulations

VERIFICATION OF OPTIMUM OPERATION METHOD BY SIMULATION FOR THE HVAC SYSTEM WITH A THERMAL STORAGE TANK IN AN ACTUAL BUILDING

The Biggest Loser REDUCING HIGHER EDUCATION COSTS BY 50%

Solar chilled drinking water sourced from thin air: modelling and simulation of a solar powered atmospheric water generator

THE SIMULATION OF PHOTOVOLTAIC POWER GENERATION AND WIND POWER GENERATION ON THE HYDRID ELECTRICITY SUPPLY SYSTEM OF A BUILDING

THE FRENCH EMBASSY IN TOKYO

Energy Conservation for Office Buildings. Major points, measures, and successful cases of energy conservation for office buildings

Peter Randall Solar Kingdom Ltd

Dharam V. Punwani Avalon Consulting, Inc. Tom L. Pierson Turbine Air Systems, Ltd.

Here Comes The Sun Applications of Solar Energy. Marc Rosenbaum, P.E. South Mountain Company West Tisbury, MA

Design and optimization of solar water heating system for a five star hotel in Varanasi

Life cycle analysis of thermosyphon solar water heaters

District cooling/heating systems in China: Challenges and Opportunities

Introduction of energy savings by CO2 refrigeration systems in SM/CVS. Feb. 3 rd 2014 Panasonic Corporation Air-Conditioner Division Gaku Shimada

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

GEOTHERMAL SPACE COOLING

CONDENSING TEMPERATURE CONTROL THROUGH ENERGY MANAGEMENT SYSTEM SIMULATON FOR A LARGE OFFICE BUILDING

Project Report: SunMaxx Commercial Case Studies

Control Optimization for a Chilled Water Thermal Storage System Under a Complicated Time-of-Use Electricity Rate Schedule

How do we cope with summer peaks? Review of changes after the 2015 crisis.

Renewables. Vacuum Tube Solar Systems. Solar Energy to the Power of

Project Report: SunMaxx Commercial Case Studies

LOW-ENERGY HOUSING ESTATE SUNDAYS

Project Report: SunMaxx Commercial Case Studies

Héctor Rubio Plana Gas Natural, SDG S.A. 18th. June 2009

University of Michigan Eco-Driving Index (EDI) Latest data: August 2017

Technology and Market Development of CO 2 Heat Pump Water Heaters (ECO CUTE) in Japan

Chilled Water Plant Redesign

Verification of Chiller Performance Promotion and Energy Saving

performance. In order to make clear the effects of thermal performance and lifestyle on thermal environment and energy consumption for well-insulated

The Double Glass Skin Façade: a sustainable option for the Curtain Wall in Mediterranean Climate Countries?

METHODOLOGY The process starts with a collection of available information, continued by an audit in loco, it is

Transcription:

Proceedings of BS213: ENERGY EVALUATION BY SIMULATION FOR EFFECTIVE USE OF SEWAGE HEAT Toshihiko Sudo 1,Ryoichi Kajiya 2, Koji Sakai 2 1 Nikken Sekkei Research Institute, Japan 2 School of Science and Technology, Meiji University, Japan ABSTRACT An effective means for greenhouse gas reduction is to use sewage heat, an unused energy resource, for air conditioning. This study conducts energy evaluation of the utilization of treated sewage, heretofore discarded from the sewage disposal plant adjacent to a developing area, as a heat source of air-conditioning for that developing area by simulation. The result estimates 12.2% reduction in annual equivalent primary energy consumption (6.4% for cooling; 36.1% for heating) with a system using a heat pump. It also predicts 16.8% of reduction in annual greenhouse gas emissions, which verifies the efficacy of sewage heat utilization. INTRODUCTION Today, deterioration of the global environment, with phenomena such as global warming, air pollution, and a rise in the sea level, is worsening. The necessity for mitigation of environmental impacts from sources such as CO 2 emissions is increasing. In addition, reduced consumption of fossil fuels, of which depletion is especially worrisome, is an important subject in Japan, which is poorly endowed with energy resources. Consequently, development of unused energy resources such as solar heat and sewage heat is a pressing need. Sewage heat is an unused urban energy resource. It is characteristic in its constant temperature through a year compared with ambient air, and its energysaving effect is expected if used as a heat source of air-conditioning. However, most sewage brought to the sewage disposal plant is treated and subsequently discharged to the sea. The heat created by sewage has not been recycled effectively. This study addresses the efficacy of employing sewage heat as a heat source for air-conditioning system, and conducts a simulation of energy consumption in annual operation in the scale of city development. Moreover, a simulation was conducted to elucidate annual operations with and without sewage heat with the same conditions and air-conditioning system. The results are compared and discussed. This simulation uses the Life Cycle Energy Management Tool (LCEM tool) 1) distributed from the Ministry of Land, Infrastructure and Transport, Japan. SIMULATION Guideline of the LCEM Tool The Life Cycle Energy Management tool (LCEM tool) has been developed so that a simulation can be conducted using highly general-purpose spreadsheet software. It enables us to estimate the operational state of an instrument numerically, and to evaluate consumption, fuel consumption, etc., by computation with spreadsheet software converting the service conditions of an instrument into input conditions and inputting a characteristic equation that is intrinsic for an instrument. Figure 1 presents a schematic view of the LCEM tool. Figure 2 presents operating characteristic example of a centrifugal chiller. Guideline of Sewage Utilization and Supply Facilities supply to a development area is assumed, considering the development area under planning in Tokyo in the future, and regarding an urban sewage plant adjacent to them as sewage heat supply facilities. Treated sewage discharged to the river is subjected to advanced wastewater treatment, and is thereafter used as a heat source for air conditioning. Life Cycle Energy Management Tool Input Given condition Output Conditions of outside air Capacity of heat source equipment consumption Indoor temperature and humidity Number of heat source equipment Fuel consumption Indoor heat load Capacity of air handling unit transfer temperature Number of air handling unit Composition of air condition system Contorol method of air condition system Figure 1 Overviews of LCEM tool. - 753 -

Proceedings of BS213: 14 12 Condensing water temperature 15 Coefficient of Performance COP : Output/Input 1 8 6 4 2 24 28 32 2 Load Factor Actual Output/Design Output Figure 2 Operating characteristic example of a centrifugal chiller (With inverter control / Mitsubishi Heavy Industries / included in LCEM Tool) Figure 3 presents the monthly temperature variation of treated sewage and ambient air. The ambient air temperature was determined from AMEDAS data of the average in 1971 2 in Tokyo, and the sewage temperature was set after the case of the Koraku 1- chome District ing and Cooling (DHC) system in Tokyo 3) as a reference. Guideline of Development Area Using Sewage and Thermal Load Table 1 presents the approximate building scale and thermal loads of the development area adjacent to the sewage disposal plant. Table 1 also presents the hourly maximum air-conditioning thermal load computed using a thermal load basic unit for each use. Figure 4 shows the cooling and heating loads on a representative day of each month. Figure 5 presents annual cooling and heating load each month. The principal building use is assumed as office and retail buildings. Only the air-conditioning load is considered, but the domestic hot water load is not included. Averaged air temperature Sewage temperature Daily maximum air temperature Daily Minimum air temperature Temperature [ ] Month Figure 3 Monthly temperature of treated sewage and ambient air Table 1 Building scale and thermal loads of redevelopment area Building use Office Retail Total Gross floor space [m 2 ] 55, 123, 673, Cooling load [W/m 2 ] 93 14 - [MJ/h] 184, 62, 246, ing load [W/m 2 ] 58 7 - [MJ/h] 115, 31, 146, - 754 -

Proceedings of BS213: Cooling Load [GJ/h] Aug Sep Jul Jun Oct May Apr Nov Feb Mar Jan Dec Time Cooling Loads ing Load [GJ/h] Jan Feb Dec Mar Nov Apr Time ing Loads Figure 4 Cooling and heating loads on a representative day of each month ( A result of the building thermal load simulation ) Cooling Load [GJ/month] ing Load [GJ/month] Month Figure 5 Annual cooling and heating load each month. ( A result of the building thermal load simulation ) Setting of Source Systems A District ing and Cooling (DHC) system is assumed as a heat source, and an energy center is established in a development area. source systems of the following three patterns are assumed, and the efficacy of sewage heat utilization is evaluated. (1) Standard system: this system is conventional heat source system, and the combined use of the electricity and natural gas energy. (2) Thermal storage system: a thermal storage system is with a heat storage water tank for cooling and heating. Thermal storage tank is same capacity of the sewage heat utilization system, for comparison and evaluation by simulation. (3) Sewage heat utilization system: The heat source of this system is all electrification energy and establishes the thermal storage tank for equalization of the sewage heat supply. Natural Gas Cooling Centrifugal chillers Boiler Equipment ed Capacity Centrifugal chillers Cooling 22, Rt COP 5.5 Gas boilers ing 94, MJ/h COP : Coefficient of Performance Figure 6 Standard System Buildings - 755 -

Proceedings of BS213: Standard System It is a system adopting a centrifugal chiller and a fuel gas boiler, set as presented in Figure 6. The total refrigerating capacity for cooling of a centrifugal chiller is 22, Rt (without inverter control) on Coefficient of Performance (COP) 5.5, and total capacity for heating of fuel gas boilers is 94, MJ/h. Thermal Storage System Figure 7 presents the heat source flow chart of a heat pump system using a heating tower. This is an allelectric system, so off-peak (nighttime) is used preferentially to suppress increases in running costs. It has centrifugal chillers with total capacity of 12,Rt (with inverter control) on COP 5.5, a heatpump refrigerator with total capacity of 4,5Rt (with inverter control) on COP 4.5 for cooling, and a heat pump refrigerator with total capacity of 68,4 MJ/h on COP 3.5 for heating. Its heat storage volume is 322 GJ (water volume of 9,6 m 3 ), which is as much as the sewage heat utilization system, for comparison. Thermal storage system is using night. Sewage Utilization System Sewage heat retrieved at the sewage disposal plant is supplied to buildings that need heat as chilled water and heated water. Treated sewage water for heat utilization is pressure-fed by a water pump in the sewage disposal plant. However, it is difficult to supply it in accordance with the variation of building thermal load of consumers because the sewage treatment quantity fluctuates with time, as presents Figure 11. It is therefore decided that treated sewage water be fed at a predetermined constant quantity. Because consumers using heat from treated sewage water feed the heat according to the thermal load of their own buildings, a heat storage tank is indispensable. Figure 8 presents the instrument capacity and heat source flow chart of the sewage heat utilization system. The total capacity of a centrifugal chillers and a heat pump refrigerator for cooling, and another heat pump refrigerator for heating, are set respectively as 12, Rt (with inverter control) on COP 5.5, 4,5 Rt (with inverter control) on COP 4.5, and 91,7 MJ/h (with inverter control) on COP 4.6 based on the heat demand and supply balance of a summer and winter representative days in Figure 9 and 1. The minimum of the daytime supplied quantity of treated sewage water is set as the predetermined supplied quantity. It is assumed that there is no treated sewage water feed at dawn of the day when sewage treatment is less than the above quantities (see Figure 8), and the heat storage quantity was 322 GJ (9,6 m3 of chilled water) so that treated sewage water is used effectively to the greatest degree possible. Figure 9 presents the balance of thermal load and heat storage quantity on a summer weekday. The refrigerators are Equipment Centrifugal chillers (with inverter control) Capacity Cooling 12, Rt COP 5.5 -pump refrigerator Cooling 4,5 Rt COP 4.5 (with inverter control) ing 68,4 MJ/h COP 3.5 storage (water) Volume 9,6 m 3 t 8 Treated sewage Cooling Figure 7 Thermal Storage System Equipment Centrifugal chillers (with inverter control) Centrifugal chillers Cooling Pump Refrigerator Exchanger Centrifugal chillers Capacity Cooling 12, Rt COP 5.5 -pump refrigerator Cooling 4,5 Rt COP 4.5 (with inverter control) ing 91,7 MJ/h COP 4.6 Exchanger for treated sewage water water storage ed water storage (Back up) Pump Refrigerator water storage ed water storage exchange Exchanger Exchanger ed Exchanger ed Exchanger 26,kW Buildings Buildings storage (water) Volume 9,6 m 3 t 8 Treated sewage water pump Volume 5,7 m 3 /h 52 kw Figure 8 Sewage Utilization System. subject to scheduled operation so that night is useful preferentially. Figure 1 presents the balance of thermal load and heat storage quantity on a winter weekday. Because buildings are used mostly for offices, thermal demand is low and treated sewage temperature reaches 1 C or higher, which is advantageous compared with ambient temperature for a heat pump. Consequently, there is less accumulated daily heat utilization quantity of treated sewage than cooling energy utilization in summer. - 756 -

Proceedings of BS213: Figure 1 Thermal load and heat storage quantity Figure 9 Thermal load and heat storage quantity on a winter weekday on a summer weekday ( A schematic diagram for determining capacity of equipment from a result of the building thermal load simulation ) Figure 11 Sewage treatment quantity ( Actual value of one of the sewage disposal plant ) SIMULATION RESULTS The simulation of annual cooling and heating operations of each system was conducted using the LCEM tool. Energy consumption was converted using the basic units in Table 2 as a primary energy scale factor. It was assumed that heating operations are conducted for six months a year from November through April. The water temperature of treated sewage water used as refrigerator cooling water for the sewage heat utilization system and heat source water for the heat pump was set constant using the monthly average in Figure 3 for each month, and the efficiency of heat source was determined thereby. The inlet/outlet water temperature differential of each heat exchanger was set as 1 C. Standard System (Power Fuel gas Combined Use) Figure 12 presents the equivalent primary energy consumption for cooling and heating of the standard system ( fuel gas combined use) for each month. Its cooling operations in August consumed 3,5 GJ, which was more than the sewage heat utilization system by 2,8 GJ (9%), whereas that in May, during comfortable seasons, consumed 12,1 GJ, which was greater than the sewage heat utilization system by 2,8 GJ (23%). Energy consumption for heating operation peaked in January at 23,9 GJ, which was greater than the sewage heat utilization system by 11,7 GJ. Table 2 Sewage Utilization System. Gas Primary energy scale factor CO2 emission factor Primary energy scale factor CO2 emission factor - 757-9.97 MJ/kWh.324 kg-co2 /kwh 45 2.11 MJ/Nm3 kg-co2 /m3

Proceedings of BS213: Primary Energy Consumption [GJ] 35, 3, 25, 2, 15, 1, 5, Power for Boiler Figure 12 Primary energy consumption for cooling and heating of the standard system Power Jan. Feb. Mar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec. Auxiliary Cooling Gas Thermal Storage System ( Pump System with ) Figure 13 presents the equivalent primary energy consumption for cooling and heating of the thermal storage system (heat pump system with cooling and heating tower). Its cooling operation in August consumed 28,4 GJ, a little more than the sewage heat utilization system by 7 GJ, whereas that in May during comfortable seasons consumed 9,2 GJ, less than the sewage Primary Energy Consumption [GJ] 35, 3, 25, 2, 15, 1, 5, Sewage Utilization System Figure 14 presents the equivalent primary energy consumption for cooling and heating of the sewage heat utilization system. The energy consumption of the sewage heat utilization system contains equivalent primary energy converted from for conveyance for treated sewage water feed pump installed at the sewage disposal plant. Its consumption by cooling operations peaked in August at 27,7 GJ. Treated sewage water shortage took place during noon - 2 p.m. on weekdays of this month when the cooling load reached the maximum, and a cooling tower was used instead during this period. Energy consumption in May during comfortable seasons was 9,3 GJ, whereas that for heating peaked in January at 12,2 GJ. heat utilization system. Energy consumption for heating operation peaked in January at 2,2 GJ, which was greater than the sewage heat utilization system by 8, GJ. This difference is considered to arise because the refrigerator was operated at high COP; the water temperature of treated sewage was almost identical to the cooling water temperature in August, although it was higher than ambient temperature in January. Auxiliary Cooling Jan. Feb. Mar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec. Figure 13 Primary energy consumption for cooling and heating of the thermal storage system. Power Annual Equivalent Primary Energy Consumption of Each System The annual primary energy consumption of each system is shown in Figure 15 and 16. The energy reduction quantity of the sewage heat utilization system was compared with each system. Energy reduction effects using sewage heat were anticipated as 6.4% for cooling, 36.1% for heating, and 12.2% annual in comparison with the thermal storage system, whereas they were assumed as 21.1% for cooling, 49.2% for heating period, and 27.5% annual in comparison with the standard system. The sewage heat utilization system was more effective than the thermal storage system with the same refrigerator in April and May during comfortable seasons. - 758 -

Proceedings of BS213: 35, 3, 25, 2, Sewage Pump Auxiliary 15, 1, 5, Figure 14 Primary energy consumption for cooling and heating of the sewage heat utilization system This is presumably true because ambient temperatures lower than treated sewage water temperature allowed refrigerator operation at high efficiency. The centrifugal chillers for cooling operation of the standard system was not inverter-controlled, but those of the sewage heat utilization system and thermal storage system were. It is therefore presumed that the great difference from the standard system results from performance factor at partial load Primary Energy Consumption [GJ] 35, 3, 25, 2, 15, 1, 5, operation. Energy consumption in heating operation of the sewage heat utilization system was smaller than that of the thermal storage system. Thereby the superiority of the heat pump system using sewage heat was verified. The standard system using fuel gas as an energy source consumed greater energy than the thermal storage system with an air-source heat pump. Consequently, the heat pump system efficacy was Confirmed. Figure 15 Primary energy consumption for cooling and heating of the sewage heat utilization system 3, Jan. Feb. Mar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec. Standard Thermal storage Sewage heat utilization Jan. Feb. Mar. Apr. May Jun. Jul. Aug. Sep. Oct. Nov. Dec. Primary Energy Consumption [GJ] 25, 2, 15, 1, 5, 21.1% 15.7% 49.2% 2.5% 36.1% Standard 27.5% 17.4% Thermal storage 12.2% Sewage heat utilization Cooling ing Cooling and ing Figure 16 Primary energy consumption - 759 -

Proceedings of BS213: CO 2 Emissions Figure 17 presents the annual CO 2 emissions of each system. CO 2 emissions from the sewage heat utilization system were expected to show 38.8% reduction compared with the standard system and 16.8% compared with the thermal storage system. CO 2 emissions with fuel gas as a heat source were estimated as significantly higher than those of the heat pump system using electric. CONCLUSION A case study was conducted assuming a sewage heat utilization system that supplies sewage heat from the sewage disposal plant to the development area. Treated sewage water quantity was predetermined based on the past records of the sewage disposal plant, and the reported values of the existing sewage heat utilization system were adopted as treated sewage water temperature. Object buildings were assumed based on the scale of the development area. The study results revealed a high energy reduction effect of the sewage heat utilization system, in particular during winter, and reduction effects by sewage heat were observed also in summer. However, little difference was observed in energy consumption for cooling between the sewage heat utilization system and the thermal storage system in comfortable seasons because of a lack of difference in the temperatures of treated sewage water and cooling water of the cooling tower. The sewage heat utilization system marked the lowest values in annual primary energy consumption and CO 2 emissions among all systems. Thereby the superiority of the sewage heat utilization was verified. The heat utilization from treated sewage water is significantly effective from a viewpoint of the energy-saving effect and greenhouse gas emission inhibiting effect. However, the treated sewage quantity varies irrespective of the thermal load of a building in an actual scheme. It is necessary to construct a system considering this point, which enables us to use heat of treated sewage effectively. In the case of Tokyo, the cooling load occupies most of the thermal load of commercial buildings, and the efficacy of sewage heat utilization is smaller than in other areas with advanced heat utilization. Thermal load properties according to building use and the exhaust heat property of heat sources should be ascertained fully for effective utilization of unused energy such as sewage heat in Tokyo. Then simulation thereof for predicting its efficacy will engender its highly value-added industrialization considering future measures against global warming and environmental protection. Moreover, there are negative factors for using sewage heat for heat sink for air cooling, such as declining trends in treated sewage quantity that are expected to occur because of water-saving measures in recent years and sewage temperature rise through the years according to progress in urbanization. CO2 emissions [t-co2] 1, 8, 6, 4, 2, Standard system Along with these issues, our future subjects include factors affecting the commercial potential of sewage heat utilization ACKNOWLEDGEMENTS The authors express their thanks to Mr. Sukegawa T. (SHINWA Corporation) for their great cooperation extended during data analysed and simulated. REFERENCES 1) Minister of Land, Infrastructure, Transport and Tourism, Minister's Secretariat, Government Buildings, Building Equipment and Environment Division, Aug. 28. Air-conditioning system simulation of EXCEL Application LCEM Tool ver.3. 2) Goto M., Ojima T., Masuda Y., Ooba E., Takahasi N., 25. Study on utilizing unused energy in Shibaura treatment plant, AIJ Transaction, pp.555-558 3) Sanada S., 1995. A Study on sewage treatment heat utilization Pump system of Koraku 1- chome district heating and cooling (DHC) system. Application of heat pumps, No.36, pp37-4 Additional notes : Economical evaluation Shown in the results table 3 was estimated for investment and running costs. For the investment, Sewage heat utilization system will increase 34% for the standard system and the annual running costs will be reduced by 5%. Payback is calculated to be approximately 8 years. Initial cost (As per the standard system) Running cost (As per the standard system) Standard system 26.4% Thermal storage system Figure 17 CO 2 emissions Table 3 Financial implication Thermal storage system 38.8% 16.8% Sewage heat utilization system Sewage heat utilization system 1. 1.29 1.34 1..58.5-76 -