Metabolomics of Carbon-Fixing Mutants of Cyanobacteria by GC/Q-TOF

Similar documents
Metabolic Changes in Lung Tissue of Tuberculosis-Infected Mice Using GC/Q-TOF with Low Energy EI

The Use of High Resolution Accurate Mass GC/Q-TOF and Chemometrics in the Identification of Environmental Pollutants in Wastewater Effluents

Instrumental Solutions for Metabolomics

MassHunter Profinder: Batch Processing Software for High Quality Feature Extraction of Mass Spectrometry Data

The Agilent Metabolomics Dynamic MRM Database and Method

Fiehn GC/MS Metabolomics RTL Library IDENTIFY MORE METABOLITES

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS

Expand Your Research with Metabolomics and Proteomics. Christine Miller Omics Market Manager ASMS 2017

Agilent Solutions for Metabolomics EMERGING INSIGHTS

Application Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore, India

Agilent Consumables Improve Performance with Shimadzu GC/MS

Agilent Solutions for Metabolomics YOUR PATH TO SUCCESS

Application Note. Abstract. Authors. Environmental

Improving GC-MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing

A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water

AGILENT SOLUTIONS FOR METABOLOMICS

Reduced carryover and increased reproducibility in the analysis of cold pressed pink grapefruit essential oil

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System

Analysis of Monoclonal Antibody (mab) Using Agilent 1290 Infinity LC System Coupled to Agilent 6530 Accurate-Mass Quadrupole Time-of-Flight (Q-TOF)

Target and Non-target Pesticide Residue Analysis Using GC/QQQ and GC/Q-TOF with a Discussion on Ways to Use Sandwich Injections

An Examination of the Presence, Formation, and Transformation of Volatile Halogenated Organic Species in Wastewater Extracts Using GC-ICP-MS

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

New Diagnostic Method for Pancreatic Cancer by Profiling of Metabolites in Serum Using GC/MS

Introduction. Benefits of the SWATH Acquisition Workflow for Metabolomics Applications

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions

Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application

Agilent OpenLAB CDS MatchCompare for the Comparison of Peptide Mapping Samples

Characterize mab Charge Variants by Cation-Exchange Chromatography

Screening for Emerging Chemical Contaminants in Water Using LC/Q-TOF and Mass Profiler Professional Software

Agilent Software Tools for Mass Spectrometry Based Multi-omics Studies

Agilent s NEW MassHunter Profinder

Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics

Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector

The Use Of Automated Backflush on the 7890A/5975A GC-MS System. Application. Setup Example Using Biomarkers. Authors. Abstract.

Discovery of Imidacloprid Metabolites in Onions Using Mass Profiler Professional

MS data: Understand it. Don t just process it. Agilent Mass Profiler Professional Software. Our measure is your success.

Agilent Ultimate Plus Fused Silica Tubing

ENHANCED PROTEIN AND PEPTIDE CHARACTERIZATION

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

Agilent Food Profiling Solutions ASSESS FOOD QUALITY AND POINT OF ORIGIN

Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

Drinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD. Application. Author. Abstract. Instrument Operating Parameters.

Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

APPLICATION NOTE Goal. Introduction. Keywords

Agilent Metabolomics Laboratory: The breadth of tools you need for successful metabolomics research

Quantification of Host Cell Protein Impurities Using the Agilent 1290 Infinity II LC Coupled with the 6495B Triple Quadrupole LC/MS System

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Analysis of Semivolatiles by GC/FID using the Ultra Inert Inlet Liners with Wool

Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene

METABOLOMICS. Biomarker and Omics Solutions FOR METABOLOMICS

Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Deans Switch With Backflushing. Application. Author.

Reproducible LC/MS Peptide Separation Using Agilent AdvanceBio Peptide Plus Columns

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

Enabling Systems Biology Driven Proteome Wide Quantitation of Mycobacterium Tuberculosis

Evolution Triple Quadrupole GC-MS/MS. Transforming the best GC-MS system into something even better.

Monitoring for Microcystins in Raw Water Supply Reservoirs Using the Agilent 6410 Triple Quadrupole LC/MS

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

Metabolomics: From Samples to Softwares

Targeted and Untargeted Screening of Microcystins in Lake Water Samples Using High Resolution Mass Spectrometry INTRODUCTION

Monitoring of Mammalian Cell Culture Media with HILIC LC/MS

Nitrosamines Analysis in Drinking Water Using GC/MS/MS Meeting Equivalence to EPA Method 521

Evolution3 Triple Quadrupole GC-MS/ Transforming the best GC-MS system into something even better.

Agilent 6430 Triple Quadrupole LC/MS System

Pesticide & Environmental Pollutant (P&EP) GC/MS/MS Analyzer 2.0

Application Note. Abstract. Authors. Introduction. Environmental

EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace

ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER

Supplementary Figure 1. Processing and quality control for recombinant proteins.

METHOD TRANSLATION OF HJ FOR INTUVO

Agilent 6000 Series LC/MS Solutions. Confidence in Quantitative and Qualitative Analysis

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Faster, easier, flexible proteomics solutions

IROA Metabolic Profiling Kits FAQ

A New Horizon of Performance Agilent G1888 Network Headspace Sampler

Improving Productivity in Your Environmental and Food Testing Labs with Agilent 7890A/5975C GC/MS System

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

for water and beverage analysis

Organohalide Pesticides in Water by GC/µECD with Agilent J&W DB-CLP1 and DB-CLP2

Faster Separations Using Agilent Weak Cation Exchange Columns

Genotoxicity is the property of a compound

MetaboScape 2.0. Innovation with Integrity. Quickly Discover Metabolite Biomarkers and Use Pathway Mapping to Set them in a Biological Context

An Integrated Approach to Metabolomics Studies: Discovery to Quantitation on a Single Platform

Selecting the Correct Agilent PLgel Column for Polyolefin Analysis with GPC/SEC

AGILENT S BIOINFORMATICS ANALYSIS SOFTWARE

CryoTrap. For Agilent Technologies 7890/6890/6850 GC Systems. CryoTrap

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

THE SOURCE OF NEW POSSIBILITIES

The Agilent 6545 Q-TOF LC/MS System. The Answers You Need:

The Agilent 6545 Q-TOF LC/MS System. The Answers You Need:

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

The clearly better choice

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

faster, confident more path to all the information in your samples. Agilent MassHunter Workstation Software Our measure is your success.

Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids

Association of Nosema ceranae Infection with Honey Bee (Apis meillfera) Exposome Profiles and Affected Biological Pathways

Olefin Analyzer Solutions for Polymer Grade Ethylene and Propylene

Transcription:

Metabolomics of Carbon-Fixing Mutants of Cyanobacteria by GC/Q-TOF Application Note Biofuel Authors Dong Hee Chung, Christine Rabinovitch-Deere, and Shota Atsumi Department of Chemistry University of California-Davis, Davis, CA Sofia Aronova Agilent Technologies, Inc. Santa Clara, CA Abstract Mutants of the model cyanobacterium Synechococcus elongatus were evaluated by untargeted metabolomics to identify possible phenotypic changes that allow more efficient growth. The mutants were analyzed using the Agilent 72 Series GC/Q-TOF, and changes in metabolite profiles were evaluated using Agilent Pathway Architect Software in Mass Profiler Professional. This approach identified a number of metabolic pathways as possible targets that could explain the improved phenotype of the mutants. Introduction Due to the finite availability of fossil fuels, as well as detrimental accumulation of CO 2 emissions, there is great interest in engineering microorganisms to generate sustainable fuel alternatives. Cyanobacteria, photosynthetic carbon dioxide fixing microorganisms, are especially attractive for their ability to use the greenhouse gas as a carbon source, and light as an energy source. However, for cyanobacteria-based biofuels to be economically feasible, cellular growth rates must be improved, as the major obstacle to industrial-scale production are low yields [1]. Previous studies have shown that carbon fixation is a key limitation in cyanobacterial growth [2]. However, many past attempts to increase the rate of carbon fixation by directed changes have yielded only minimal improvements. Thus, a directed evolution approach may allow identification of beneficial metabolic changes that had not previously been considered.

This application note describes a study aimed at overcoming the growth limitations of cyanobacteria by randomly mutagenizing and screening the S. elongatus PCC7942 wild type cyanobacterium for mutants that grow and fix CO 2 more efficiently. The resulting mutants were further evaluated using an untargeted metabolomics approach on the accurate mass high resolution 72 GC/Q-TOF system. The accurate mass data were processed using multiple software tools, including Pathway Architect, in order to identify metabolic pathways that might be involved in beneficial changes. This study revealed a number of metabolic pathways that might be responsible for the improved characteristics of the cyanobacteria mutants. Experimental Instruments This study was performed using an Agilent 789B GC system, coupled to an Agilent 72 GC/Q-TOF system. The instrument conditions are listed in Table 1. Table 1. GC run conditions Column GC and Mass Spectrometer Conditions Agilent J&W DB-5 MS Ultra Inert, 3 m.25 mm,.25 µm (p/n 122-5532UI) Injection volume 1 µl Split ratio 1:1 Split/splitless inlet temperature 25 C Oven temperature program 6 C for 1 minute, 1 C/min to 325 C, 3.5 minutes hold Carrier gas Helium at 1 ml/min constant flow Transfer line temperature 29 C MS conditions Ionization mode EI Source temperature 23 C Quadrupole temperature 15 C Mass range 5 to 8 m/z Spectra acquisition rate 5 Hz, collecting both in centroid and profile modes Sample preparation Wild type S. elongatus PCC7942 was mutagenized using ethyl methanesulfonate (EMS), or nitrosoguanidine (NTG). After recovery, cells were grown in the presence of high concentrations of CO 2. Dense cultures were back-diluted over several rounds to enrich cells with faster growth rates. Promising isolates were later confirmed in triplicate using growth assays. Of 16 candidates, four mutants were chosen for further analysis based on growth rates compared to wild type. Metabolites were extracted by methanol/chloroform extraction. Aqueous fractions were collected, dried, and consecutively derivatized by methoximation using a saturated solution of hydroxylamine HCl in pyridine and by silylation with N-methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA) and 1 % trimethylchlorosilane (TMCS), respectively. Data processing and statistical analysis The data were processed by chromatographic peak deconvolution using the Unknowns Analysis tool from MassHunter Quantitative Analysis Software package (B.7), followed by compound identification by comparison to the Agilent Fiehn GC/MS Metabolomics Retention Time Locked (RTL) Library. Metabolite identities were further confirmed using accurate mass information and the accurate mass tools in the MassHunter Qualitative Analysis Software package (B.7). Statistical analysis was performed by Mass Profiler Professional (MPP) (12.6), a multivariate statistical analysis package, to identify metabolomic differences between the mutants and the wild type strain as well as differences between the mutants. The relative levels of metabolites were further quantified using MassHunter Quantitative Analysis Software. Finally, biochemical pathways potentially involved in beneficial changes in the mutants were identified using Pathway Architect in MPP. 2

Results and Discussion Chromatographic peak deconvolution and library search The data were processed by chromatogram deconvolution using the Unknowns Analysis tool (Figure 1) with a 1 ppm accurate mass setting and variable Retention Time Window Size Factor (75 2) in order to find the highest number of true components (Figure 1). Compounds were identified by comparison with the Agilent-Fiehn GC/MS Metabolomics Retention Time Locked (RTL) Library. The deconvolution process took approximately 4 5 minutes for each sample, and the library search took less than a minute per sample using default screening parameters. A number of compounds were identified only when a mass extraction window of ± 1 ppm, but not a parameter of +.3/.7 Da, was used for deconvolution. Thus, using accurate mass settings allowed more real components to be found (Figure 2). The identity of each compound found by deconvolution was confirmed using accurate mass information, the Molecular Formula Generator tool, and the Fragment Formula Annotation tool in MassHunter Software (Figure 3). Myristic acid Coeluting component Figure 2. Counts 1 4 1.4 1.2 1.8.6.4.2 16.86 16.88 16.9 16.92 16.94 16.96 16.98 17 Acquisition time (min) Myristic acid (blue and pink peaks) was distinguished from a coeluting component (yellow and green peaks) and hence identified only when an RT Window Size Factor deconvolution parameter of 1 ppm, but not +.3/.7 Da, was selected A B C Figure 1. An unknowns analysis software tool was used to perform chromatogram deconvolution. The chromatogram is shown in A, while the overlaid EICs of the component are shown in B, and the mirror plot of the component and library hit spectra is shown in C. 3

Figure 3. Formula Generator tool of Agilent MassHunter Qualitative Software package was used together with library search and Fragment Formula Annotation to automatically assign fragments of the compound to confirm compound identification. A fragment is annotated and colored green when the formula of the fragment is a subset of the molecular formula identified by a library search. Verification was performed using the NIST11.L library. Identification of significant metabolomic differences Significant differences in metabolite production between the cyanobacteria wild type and mutant strains were determined using statistical tools in MPP. First, Principal Component Analysis (PCA) was used to visualize clustering of the data. Distinct PCA clusters of each group of replicate samples indicated good repeatability of data and significant metabolomics differences between the five cyanobacteria strains (Figure 4). Y-axis 5-5 -1-15 -6-4 -2 2 1 1 Color by strain M1 5 5 M2 M3 M4 WT X-axis -6-4 -2 2 5-5 Z-axis -15-1 Figure 4. The PCA plot of wild type and mutant samples confirms the existence of distinct clusters due to variability between each strain. 4

Significant differences in metabolite levels between strains were determined using Fold Change Analysis (FCA) and seen on a Volcano plot where the Fold Change of metabolite concentration was plotted against the statistical significance of this change (Figure 5). Compounds with high Fold Change in their levels and low p-values between a pair of the compared strains (conditions) are colored in red and thus can be easily identified. Compounds on the right side of the plot are those in higher abundance in the wild type, while compounds on the left side of the plot are those in higher abundance in the mutant, relative to the wild type (Figure 5). Compounds accumulating in M2 mutant Compounds accumulating in wildtype Figure 5. Volcano plot of Fold Change showing negative log1 of p-value versus log2 of Fold Change in metabolite levels for wild type versus. the M2 mutant. The data points that satisfy p-value cut-off of.5 and Fold Change cut-off of 2 are colored in red. 5

MassHunter Quantitative Analysis Software was also used to make a semiquantitative comparison of metabolite concentrations in the mutants versus the wild type cyanobacteria strain. The software automatically creates a quantitation method for all metabolites using the acquired data and the information from the library search. It is optimized to select for both abundance and specificity of quantifier and qualifier ions. Selection of a narrow mass extraction window of 1 ppm for the quantifier ions took advantage of accurate mass information and increased selectivity to ensure superior quantitation (Figure 6). The important differences in metabolite abundance levels between strains included organic acids, amino acids, and sugar monophosphates among others (Figure 7). While levels of the central metabolite glucose are similar for all strains, other metabolites, including those key to the TCA (citric acid, malic acid, and so forth) and carbon fixation cycles (2-phosphoglyceric acid, ribose -6-phosphate), show significant differences between wild type and mutants. Accumulation of adenosine, but not adenosine-5-monophosphate, in all mutants versus the wild type suggests a common metabolic bottleneck (Figure 7). 1 5 2.5 2 1.5 1.5 1 5 2.5 2 1.5 1.5 Figure 6. A 6.651 minutes 6.56 6.58 6.6 6.62 6.64 6.66 6.68 6.7 6.72 6.74 Acquisition time (min) B 6.651 minutes 6.56 6.58 6.6 6.62 6.64 6.66 6.68 6.7 6.72 6.74 Acquisition time (min) Extracted ion chromatogram (EIC) of a quantifier ion for pyruvic acid extracted with the mass window of +.3/.7 Da (A) and ±1 ppm (B). Using the narrow 1 ppm mass window increases the accuracy of quantitation by eliminating interferences included in the quantitation using the less selective +.3/.7 window setting. 2,, D-Glucose 2, Fructose-6-phosphate 6,, 4,5, Citric acid 1,, 1, 3,, 1,5, WT M2 M3 M4 M1 WT M2 M3 M4 M1 WT M2 M3 M4 M1 12,, Aspartic acid 3, 2-Phosphoglyceric acid 12, Ribose-5-phosphate 9,, 6,, 3,, 2, 1, 9, 6, 3, WT M2 M3 M4 M1 WT M2 M3 M4 M1 WT M2 M3 M4 M1 1,2, 9, 6, 3, Malic acid WT M2 M3 M4 M1 4,8, 3,6, 2,4, 1,2, Adenosine WT M2 M3 M4 M1 48, 36, 24, 12, Adenosine-5-monophosphate WT M2 M3 M4 M1 Figure 7. Semiquantitative comparison of selected metabolite levels in the wild type versus the mutants. 6

Pathway Analysis of Metabolomic Differences The S. elongatus mutants were investigated in further detail to understand how a change in levels of specific metabolites may be caused by changes to specific metabolic pathways. Pathway analysis was performed using Pathway Architect, and some of the results are shown for M2 as an example (Figure 8). The results suggested that beneficial genotypic changes may have occurred in several key metabolic pathways, including the carbon fixation and tricarboxylic acid (TCA) cycles, glycolysis, and fatty acid biosynthesis. Figure 8. Example pathway analysis results for the M2 mutant strain suggest changes to the TCA cycle, versus the wild type strain. Highlighted metabolites mapped on the pathway are the ones that belong to the pathway and identified in the experiment. The heat map in the table indicates relative levels of metabolites between two compared strains. 7

Conclusions An untargeted metabolomics approach has been used to identify metabolomics changes in mutants that display improved characteristics useful for a range of applications, including biofuel production. Accurate mass information provided by the Agilent 72 GC/Q-TOF was crucial for specific metabolite identification and quantitation. Several software tools, including Unknowns Analysis in MassHunter Quantitative Analysis, as well as Principal Component Analysis, Fold Change analysis, and Pathway Architect in Mass Profiler Professional were essential for identification of metabolic changes in specific pathways responsible for the improved characteristics observed in the mutants. References 1. D.N. Juurlink and I.A. Dhalla Bioengineering of carbon fixation, biofuels, and biochemicals in cyanobacteria and plants J Biotechnol. 162, 134-147 (212). 2. G.G. Tcherkez, G.D. Farquhar, T.J. Andrews Despite slow catalysis and confused substrate specificity, all ribulose bisphosphate carboxylases may be nearly perfectly optimized PNAS 13, 7246-7251 (26). For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 213 Published in the USA December 5, 213 5991-3476EN