TECHNICAL BULLETIN TB-1800-XX. Unsupported Edge Conditions of Insulating Glass Units

Similar documents
Polyisobutylene (PIB) Primary Sealant

Point-Supported Glazing

JE Berkowitz, L.P. Architectural Glazing Guide Specification for Enviroscreen Silk-Screened Glass

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

OPACI-COAT Water-base Silicone Glass Coating

SECTION GLAZING. A. Section Includes: 1. Glass for other sections referencing this Section.

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

Point Supported Glazing

Designing Glass to Resist Wind and Snow Loads

Multi-Cavity Insulating Glass Units

PART 1 - GENERAL 1.01 SUMMARY 1.02 REFERENCES. Section Glazing. JE Berkowitz, L.P

SECTION SPECIAL FUNCTION GLAZING

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

OPACI-COAT Water-base Silicone Glass Coating

for more information call or go to zeledyne.com

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Spandrel Glass Types and Recommendations

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

JE Berkowitz, L.P. (updated ) B. The basis of design is the JEB Invisiwall Wall (Point Supported) by JE Berkowitz, LP. C.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

SECTION DYNAMIC GLAZING PART 1 - GENERAL 1.1 SUMMARY

SILVER LINE BUILDING PRODUCTS

North Hanover Township School District North Hanover Township, New Jersey

Series 4900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

4600 Series Specifications (Section 08520)

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION ALUMINUM GLASS FLOOR SKYLIGHT SYSTEMS

Series B450 Guide Specification

SECTION GLAZING

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

Guide Specification for Pre-Engineered Skylight System. A. Engineering, design and drafting of the entire skylight system.

Repair Maintenance Hangar Phase II August 2010

Structural Performance Tests of VHB Structural Glazing Tapes

SECTION GLAZING ADDENDUM 10 APRIL 20, 2011

SECTION ALUMINUM CURTAIN WALL PART 1 - GENERAL

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION METAL FRAMED SKYLIGHTS

FL550 21/2 x5 GUIDE SPECIFICATION. Impact-Resistant Storefront

SECTION / METAL FRAMED SKYLIGHTS

SECTION GLASS AND GLAZING (WINDOWS)

Blast Resistant Glazing

BLAST PERFORMANCE OF NON-CAPTURED STRUCTURALLY GLAZED INSULATED GLASS UNITS SAMUEL POND, P.E. + JAMES CASPER, S.E., P.E.

FL550T 21/2 x5. GUIDE SPECIFICATION Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront. Thermal Impact-Resistant Storefront

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

SECTION ALUMINUM WINDOWS

SIDE HINGED SECURITY ALUMINUM WINDOWS

A. Manufacturer: A firm that produces primary glass or fabricated glass as defined in referenced glazing publications.

Technical Application

Edge Grinding: Safety vs. Aesthetics. Fall Conference. Las Vegas, NV September 11, 2018

Edge Grinding: Safety vs. Aesthetics. Fall Conference Las Vegas, NV September 11, /24/2018

JONES AIRWAYS, LLC CLEVELAND REGIONAL JETPORT SECTION GLAZING

SSG. Fundamentals of Structural Sealant Glazing. Introduction

TEST REPORT. Report No.: G Rendered to: CR LAURENCE CO., INC. Vernon, California

Section Aluminum Windows (2700 Model Specifications)

SECTION STAINLESS STEEL WALL PANELS

.2 Section Waste Management and Disposal.

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

SECTION ALUMINUM WINDOWS

Alabama A&M University Laundry Building at Normal Hill Apartments Project No ADDENDUM NUMBER 4

Prescriptive Wind Pressure Performance of Foam Plastic Insulation Used as Insulating Sheathing in Exterior Wall Covering Assemblies. TER No.

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

Corium Brick Rainscreen System Specifications

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

General Glazing Guidelines

SOTA THERMO 3 SERIES SPECIFICATION FOR PREGLAZED & UNITIZED THERMO 3 CURTAINWALL SYSTEM

SECTION GLAZING

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: LEED HIMMEL INDUSTRIES, INC. Hamden, Connecticut

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

SPECIFICATIONS SECTION 08600

SECTION DECORATIVE GLASS GLAZING. A. Decorative specialty glass glazing for interior applications, including:

Section Aluminum Windows (2700 Model Specifications)

TMW 450 TECHNICAL MANUAL

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

Challenges of Bent Insulating Glass

DIVISION: SPECIALTIES SECTION: DEMOUNTABLE PARTITIONS REPORT HOLDER: KRUEGER INTERNATIONAL, INC.

WESTECK WINDOWS and DOORS

AAMA THERMAL PERFORMANCE TEST REPORT. Rendered to: GAMCO CORPORATION. SERIES/MODEL: Curtain Wall TYPE: Glazed Wall Systems (Site-built)

ETC Laboratories Measuring Up To Your Standards And More

ARCH 478 OFFICE BUILDING SECTION GLAZING

CTB Commercial Aluminum Window

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

United Window & Door - Series 5500 New Construction Double Hung Windows Specifications

SECTION SERIES 200 DOUBLE-HUNG VINYL WINDOWS

A typical structural glazing system is composed of a number of essential components:

YES SSG TU Vent Window System

S P A N D R E L SPECIFICATION GUIDE

B. Mirror glass for toilet rooms is specified in Section "Toilet Accessories."

2004 MASTER FORMAT SECTION Façade Panels

SECTION ALUMINUM WINDOWS

Transcription:

Unsupported Edge Conditions of Insulating Glass Units TB-1800-XX Copyright 20XX Insulating Glass Manufacturers Alliance and the Glass Association of North America. All rights reserved. Disclaimer The information and recommendations contained in these guidelines were developed by representative members of GANA and IGMA as advisory information. However, it should not be assumed that all acceptable procedures are contained in these guidelines or that additional measures may not be required under certain circumstances or conditions. Note that the various codes and regulations referenced in this document may be amended from time to time and it should not be assumed that the versions referenced herein are the most current versions of such codes and regulations. Please consult the appropriate regulatory authorities for the most up-to-date versions. Compliance with all local governing building codes is also required. The Glass Association of North America (GANA) and the Insulating Glass Manufacturers Alliance (IGMA) makes no warranty or representation and assumes no liability or responsibility in connection with any information contained in these guidelines. GANA and IGMA assume no liability or responsibility in connection with any modifications to or adaptations of these guidelines by any user, purchaser or other party, or in connection with the use or misuse of any information contained in these guidelines. While both organizations recommend the use of and reference to these guidelines by private industry and others, these guidelines are intended to be voluntary and not binding. GANA and IGMA do not approve or endorse any products, services or methods mentioned herein. These guidelines should not be referenced in any way, which would imply such approval or endorsement. Visit the IGMA website at: www.igmaonline.org And the GANA website at www.glasswebsite.com TECHNICAL BULLETIN Page 1

1.0 Scope & Introduction 1.1 Scope: 1.1.1 This technical bulletin addresses concerns regarding the structural and durability performance of unsupported insulating glass unit edges subject to uniform load including glass stresses, practical glass deflections, sealant strength capabilities, spacer stress and deformation limits, load durations, dead load support and setting block location and other variables that influence the unsupported edge condition for insulating glass units. 1.1.2 This bulletin seeks to explain these and other technical issues so that the designers can understand the abilities and / or limitations of the glazing industry, primarily represented by the IGU fabricators, to respond to this design intent. 1.1.3 Point-supported systems are not addressed in this document. 1.1.4 This bulletin does not address approval or warranty of IGUs in unsupported edge conditions, and the discussion herein does not imply approval of use or warranty by IGU fabricators. Users and specifiers of unsupported IGUs should consult directly with IGU fabricators for any recommended limits on design, use and warranty of IGUs in unsupported edge conditions. 1.2 Introduction 1.2.1 One of the more technically challenging situations facing glazing contractors, glass fabricators, and framing suppliers being posed by the design community is to support insulating glass units along two edges only, with the other two edges not having any framing support at the edge of the glass unit(s). The designers have sought to give the perception of more openness to a wall or window as well as permitting additional daylighting to reach further into the building interior by eliminating framing members. 1.2.2 Monolithic and laminated glass lites have been primarily used to achieve this aesthetic. But because they offer better overall energy performance, architects and designers are now seeking to use insulating glass units (IGU) in these designs in lieu of monolithic or laminated glass solutions. 1.2.3 To date, it has been standard glazing industry practice not to allow the use of IGU s in such construction. There are several concerns that must be resolved: 1.2.3.1 There has not been sufficient data or testing to confirm how such glazing would resist wind loading. Therefore, standards such as ASTM E 1300 do not currently allow calculations of wind load capability for unsupported edges. Nor is there any empirical data on edge deflection of IGUs with unsupported edges. The result being there s no supporting data to set the deflection limit for unsupported IGU glass edges as an industry standard. Page 2

1.2.3.2 Unsupported IGU edges may impact the durability or service life of the edge seal of the IGU due to edge deflection. 1.2.3.3 The location of glass setting blocks to support the dead load weight of the glass must be addressed where horizontal framing members are not present, thus eliminating the recommended means of supporting the weight of the individual glass lite(s). 1.2.4 The intended or designated glass fabricator or supplier should review the design for its technical feasibility before the design team proceeds to the point where unsupported IGU edges are included in schematic, design development or any contract documents. If the glass application is approved by the intended fabricator, the frame manufacturers can generally develop the system details to meet the design intent. However, the frame supplier only knows one side of the two-part issue, and theirs is the lesser of the two as far as meeting all technical aspects of a given design. The glass supplier or fabricator may have the overriding say as to whether or not the design can be built with the appropriate warranties the design team requires for the glass as well as the support system. 1.3 ASTM E 1300 applies only to monolithic or laminated glass constructions of rectangular shape with continuous lateral support along one, two, three or four edges. The practice assumes that: 1.3.1 The supported glass edges for two, three and four-sided support conditions are simply supported and free to slip in plane. 1.3.2 Glass supported on two sides acts as a simply supported beam 1.3.3 Glass supported on one side acts as a cantilever. 1.3.4 For insulating glass units, this practice applies to IG units with four-sided edge support only. 1.4 It is necessary to pint out that many, if not most, insulating glass fabricators will not approve and will not warrant their glass in framing designs that do not firmly support all edges of the insulating glass unit. 2 Uniform Load Including Glass Stresses 2.1 The loading criteria for insulating glass units with unsupported edges is normally provided by the engineer or architect responsible for the project design to meet the project requirements as indicated in the specifications and/or building code that applies to the building location. The uniform load for the glass is provided in units of pounds per square foot (psf) or kilopascals (kpa). A method for analyzing single glass (as defined in ASTM E 1300) with unsupported edges is presented in the ASTM standard E1300 Standard Practice for Determining Load Resistance of Glass in Buildings. The E1300 standard provides non-factored load charts and deflection charts for monolithic glass subjected to uniform loads for various glass thicknesses used in building design. This information can be used background for understanding insulating glass units. Page 3

2.2 When analyzing insulating glass with unsupported edges the stresses of importance will be the edge and surface stresses. The method used to determine the values of stress are based on the method used to evaluate the insulating glass under the uniform loading condition whether it be a classical plate theory technique, finite element analysis, testing or other method. The ASTM E1300 standard provides in the Annex sections X6- Approximate maximum surface stress to be used with independent stress analysis and X7- Approximate maximum edge stress for glass. These two sections of the standard are appropriate for the engineer to use conservative allowable stresses to evaluate glass. The standard provides allowable edge and surface stresses for annealed, heat-strengthened and tempered glass. 3 Glass Edge Deflections 3.1 As noted in Section 2403.3 of the International Building Code (IBC) 2015 of the ICC: the framing members for each individual pane of glass shall be designed so the deflection of the edge of the glass perpendicular to the glass pane shall not exceed L/ 175 of the glass edge length or 3/4 inch (19.1 mm), whichever is less, when subjected to the larger of the positive or negative load where loads are combined as specified in Section 1605. 3.2 The L/175 edge deflection limit is a reasonable method to be employed to limit the edge stress on glass and give the designer of the framing system proper guidance so that the glass is properly supported in an effort to utilize the appropriate glass load resistance based on testing and analytical methods for determining stresses and deflections of glass. The limit assures that there is edge support around the perimeter of the supported edges of glass. The edge deflection should not be confused with the center of glass deflection. The center of glass deflection will be analyzed based on aesthetic conditions, edge pullout characteristics, effect on gaskets and sealants, and possible contact with other building materials to name a few items that may cause the designer to limit center deflection. Glass strength and resistance to breakage is the primary issue with center deflection as an item that should be thoroughly reviewed and if need be limited by the designer. 3.3 The L/175 and / or 19.1 mm (¾ ) maximum limit mentioned has been used by the glass and glazing industry for many years and has proven to be a safe limit for insulating glass deflection limits as well as general edge of glass limits for most window designs that are subjected to wind and snow loads. To date there have not been any reported failures when the edge deflection limit of L/175 or 19.1 mm (¾ ), whichever is less, is used for insulating glass edge seal designs. 3.4 There are various other references to the L/175 edge deflection limit. The following sources are noted: Page 4

North American Glazing Guidelines for Sealed Insulating Glass Units for Commercial and Residential Use, IGMA TM-3000-90(16), Section 3.1 Standard Practice for Determining Load Resistance of Glass in Buildings, ASTM E 1300-12a ε ¹, Section 5.2.4, pg. 3 GANA Glazing Manual, Glass Association of North America, 50 th Anniversary Edition, pg. 91 Structural Properties of Glass, AAMA Aluminum Curtain Series No. 12, 1984, pg. 17 3.5 For those special cases when the edge of an insulating glass unit is not supported it is recommended to limit the deflection along that edge to the L/175 or 19.1 mm (¾ ) whichever is less criteria. Extra attention for special cases can be dealt with on an individual basis for those conditions which exceed this limit. One option to limit deflection is to use thicker glass. 3.6 The present ASTM E 1300 and CAN/CGSB 12.20-M89, Structural Design of Glass for Buildings, standards do not address unsupported edges in insulating glass units and due to the number of variables that exist in the fabrication of insulating glass there is not a common method that will address all cases. 4 Edge Seal System Strength Capabilities 4.1 The primary seal Polyisobutylene (PIB) offers no structural support to the insulating glass unit. It acts specifically as a barrier for moisture ingress and means of insulating gas retention. 4.2 If an Insulating Glass Unit (IGU) is structurally glazed, any secondary sealants must meet ASTM C1369: Standard Specification for Secondary Edge Sealants for Structurally Glazed Insulating Glass Units. The secondary sealant of the IGU should always meet the minimum sealant contact width requirement as determined by the IGU manufacturer and / or designer based on the allowable design strength of the sealant and recommendation of the sealant supplier. Both dynamic (wind load) and static (dead load) loads must always be considered to determine the correct secondary sealant contact width for long term durability of the insulating glass unit. 4.3 ASTM C1249 Standard Guide for Secondary Seal in Insulating Glass Units, IGMA TM-3000-90 North American Glazing Guidelines for Sealed Insulating Glass Units for Commercial and Residential Use and the GANA Glazing Manual should be considered in helping to choose the right components and design the right IGU for the desired application. 4.4 Several considerations need to be given when choosing a sealant if a butt glaze will be used between two unsupported IGU s. The butt joint sealant Page 5

must be compatible with the components of the IGU s (primary and secondary sealant, spacer etc.) to ensure it will not affect performance or create aesthetic problems. The same consideration must be given If laminated glass or Low-e glass is used in the IGU construction. Additionally, the butt joint sealant needs to be compatible with the secondary IGU sealant to prevent adhesion loss or discoloration. Contact the sealant and component suppliers for appropriate compatibility and adhesion testing. 5 Dead Load Support and Setting Block Location 5.1 The setting block locations for the supported edge of the insulating glass units will follow the guidelines outlined in the IGMA and GANA glazing guidelines referenced in this document (See section 6.0). 6.0 References 5.2 When a wall system design eliminates horizontal framing members, the issue of how to support the dead load weight of individual lites must be addressed. Stacking lites on each other with hard rubber blocks placed in the joints between lites is generally not permitted by the glass fabricators. Typically, setting blocks are located at or near the lower corners of the insulating glass unit with the framing system providing a shelf of some type to receive the blocks and the weight of the glass. Locating the setting blocks in close proximity to the IGU s corners increases the stress in the glass at one of the IGU s weakest points. Doing so may require the individual lites making up the IGU be increased in thickness and / or heat treatment, or both. The glass fabricators can address specifically how the IGU makeup responds to these types of conditions. ASTM C 1249, Standard Guide for Secondary Seal for Sealed Insulating Glass Units for Structural Sealant Glazing Applications ASTM C 1369, Standard Specification for Secondary Edge Sealants for Structurally Glazed Insulating Glass Units ASTM E 1300, Standard Practice for Determining Load Resistance of Glass in Buildings GANA Glazing Manual, Glass Association of North America, 50 th Anniversary Edition, pg. 91 International Building Code (IBC) 2015 of the ICC Section 2403.3. North American Glazing Guidelines for Sealed Insulating Glass Units for Commercial and Residential Use, IGMA TM-3000-90(16), Section 3.1 Structural Properties of Glass, AAMA Aluminum Curtain Series No. 12, 1984, pg. 17 Consult the Publications page of the Insulating Glass Manufacturers Alliance (www.igmaonline.org) or the Tech Center section of the Glass Association of North Page 6

America (GANA) website (www.glasswebsite.com) for additional information and glass industry reference resources. Page 7