FASTLOCK SUSPENDED CEILING GRID ECOPLUS SYSTEMS. FasTLock SUSPENDED CEILING GRID. Stronger, more durable

Similar documents
GRID SYSTEM ECOPLUS SYSTEMS TWO-WAY EXPOSED SUSPENDED CEILING GRID SYSTEM

PEAKFORM SUSPENSION SYSTEMS

PEAKFORM SUSPENSION SYSTEMS

CEILING SYSTEMS. PeakForm. Between us, ideas become reality SUSPENSION SYSTEMS

CEILING SYSTEMS. Between us, ideas become reality. PeakForm SUSPENSION SYSTEMS

SRP CEILING SYSTEMS HANDBOOK

Student Services & Classroom Addition

SHORTSPAN. Features. Components

General applications. Fast. Easy. Customer Focused.

7 th October, Bailey Interiors / Australian Plaster Acoustics Boundary Rd Mortdale NSW Attn: Roger Bailey Ref: A

ROCKFON SYSTEM T24 A/E

ROCKFON SYSTEM T24 A/E

SECTION NON-STRUCTURAL METAL FRAMING

ROCKFON SYSTEM ULTRALINE E

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Construction Standards PAGE

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Installation Guide December 2012

CI/SfB (35) Xy [ Between us, ideas become reality. ] September 2005 FLAT. DrywallGridSystem. Technical Guide CURVED

SECTION NON-STRUCTURAL METAL FRAMING

LINEAR METAL CEILINGS Section

SUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)

SECTION (09512) - ACOUSTICAL TILE CEILINGS

THIS SECTION IS BASED ON ROCKFON S TRADITIONS METAL CEILING PANELS.

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

1222 Moonshine Rd, RD1, Porirua 5381 Private Bag Porirua 5240, New Zealand Tel: branz.co.nz. Important Notice

METALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description

Store No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS

AXIOM Building Perimeter System Assembly and Installation Instructions

References in blue are general indicators to the specifier. If not used it can be deleted, but may be needed in the future.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION ACOUSTICAL PANEL CEILINGS

SECTION STEEL DECKING

SYNTHETIC SELF SUPPORT ROOFING UNDERLAY

GM-CM30078-RevA. Metalcraft Insulated Panel Systems I Specification Guide V1 NZ I June

PRIMA CERAMIC TILE UNDERLAY. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 636 [2008]

4 " " SEE DETAIL B1.2. SPECIFICATIONS (unless noted otherwise)

Rondo duo. Two-Way Exposed Suspended Ceiling Grid System. revised: august 2008

PLANK AND LARGE PANEL STABILIZER BARS APPLICATION GUIDE

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

SECTION LINEAR METAL CEILINGS

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

CEILING SYSTEMS ORCAL AXAL VECTOR. Technical Data Sheet. Semi-concealed system on exposed 24mm grid. [ Between us, ideas become reality.

THIS SECTION IS BASED ON ROCKFON S CURVGRID ONE-DIRECTIONAL CURVED METAL CEILING PANELS.

WATERTIGHT ROOF UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 938 [2017] Appraisal No. 938 (2017) BRANZ Appraisals

Installation guide. ROCKFON System Z mm. 600 mm

Make Waves. Topo 3-Dimensional System

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

Basic Suspension Systems

THIS SECTION IS BASED ON ROCKFON S SPANAIR HOOKON METAL CEILING PLANKS.

SECTION AXIOM INDIRECT FIELD LIGHT COVE PERIMETER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

Rondo DUO. Two-Way Exposed Suspended Ceiling Grid System

EXPOSED GRID CEILING SYSTEMS INSTALLATION GUIDE

REHAU UPVC WINDOWS AND DOORS. Product. Scope. Appraisal No [2018] Appraisal No (2018) Amended 22 August 2018.

PAULOID SYNTHETIC ROOFING UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 984 [2017] Appraisal No. 984 (2017) BRANZ Appraisals

d u o installation guide duo Exposed Grid Ceiling System

Adjustable Suspension Hanger Technical Datasheet

Architectural Roofing

National Construction Code Series (NCC 2012) Building Code of Australia (BCA)

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

STANDARD PRODUCTS - CUSTOM LOOK

CEILING & WALL SYSTEMS

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

SECTION ACOUSTICAL PANEL CEILINGS

system 130 modular lay-in tiles (exposed grid) SAS International +44 (0)

SECTION ACOUSTICAL CEILINGS

ROCKFON SYSTEM T24 X

WC SERIES SPECIFICATION SECTION ACCESS FLOORING

CI/SfB. October RockLink 15. Installation system

SECTION ACOUSTICAL TILE. *(Filed Sub-Bid Required) 1.00 TIME, MANNER AND REQUIREMENTS FOR SUBMITTING SUB-BIDS

SAS International Ltd. System 120 By SAS International Ltd. Product summary page for System 120 generated by ribaproductselector.

SECTION MISCELLANEOUS METALS

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

SECTION Metal Studs, Lath, Suspension Ceilings, Plaster, and Stucco Ceramic Tile.

Plank and Large Panel Stabilizer Bars

THIS SECTION IS BASED ON ROCKFON S PLANOSTILE D LAY-IN METAL CEILING PANELS.

The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers.

***************************************************************************************************************

Tate Strut. Steel Structural Ceiling Grid System for Data Centres. Metric Edition

SECTION COMPOSITE METAL DECKING

1. Hangers and supports for electrical equipment and systems.

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

STEALTH ROOFLIGHTS. Product. Scope. Appraisal No. 987 [2018] Appraisal No. 987 (2018) BRANZ Appraisals

Preassembled steel stairs with concrete-filled treads.

AXIOM Perimeter Trim CEILING SYSTEMS. Between us, ideas become reality

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

SECTION Metal Studs, Lath, Suspension Ceilings, Plaster, and Stucco Ceramic Tile.

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland

System S 14a Linear rilled planks, concealed. System S 14b Linear rilled planks, semi-concealed. OWAcoustic premium. OWAconstruct

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

Install Instruction LOOP RECESSED

Geometrik Manufacturing Inc.

Transcription:

ECOPLUS SYSTEMS FASTLOCK SUSPENDED CEILING GRID FasTLock SUSPENDED CEILING GRID Ver 3.0 Dec. 2011

ECOPLUS SYSTEMS CONTENTS 3: The FasTLock Advantage 4: FasTLock product detail 5: FasTLock 15 product detail 6: Specification and technical information 7: Contact details Building Codes and Applicable Standards FASTLOCK SUSPENDED CEILING GRID Ecoplus Systems suspended ceiling grid is appraised by BEAL (Building Element Assessment Laboratory) as a system meeting the applicable Australian and New Zealand standards for suspended ceiling systems. The following codes and standards are referred to within this manual and or the BEAL Appraisal Certificate for compliance with the respective building codes of Australia and New Zealand; AS/NZS 2785:2000 NZS 4219:1983 AS/NZS 1170:2002 AS/NZS 1170.5 AS 1791:1986 AS 2946:1991 AS 4600:1996 AS 4680:2006 AS/NZS 7:2001 AS/NZS 1530.3:1999 AS/NZS 3101:2006 AS/NZS 4534:2006 NZS 3602:2003 NZS 3603:1993 NZS 3604:1999 Suspended Ceilings Design and Installation. Specification of Seismic Resistance of Engineering Systems in Buildings. Structural design actions Seismic compliance Chromate conversion coatings Suspended Ceilings, recessed luminaries and air diffusers Cold form steel structure code Hot-dipped galvanised (zinc) coatings on fabricated ferrous materials. Steel sheet and strip Hot dipped zinc coated or aluminium /zinc coated. Methods for fire testing Concrete Structures Standard Zinc and zinc/aluminium alloy coatings in steel wire Timber and wood-based products for use in building. Timber structures standard Timber framed Buildings New Zealand Building Code Handbook and Approved Documents, Building Industry Authority, 1992 up to, and including October 2004 amendment NZBC B2 Durability FasTLock and FasTLock 15 will have a minimum serviceable life of 15 years when installed in a dry, non corrosive, interior installation Technical Information In addition to the information provided in this manual, further technical information can be found in the BEAL (Building Element Assessment Laboratory) Appraisal certificate which is available by visiting www.ecoplus-systems.com 2

FasTLock THE ADVANTAGE FasTLock Suspended Ceiling Grid by Ecoplus Systems is an innovative range of ceiling grid components engineered to provide a stronger more durable suspended ceiling system. FasTLock is designed to accoodate a wide variety of Ecoplus ceiling tile solutions including mineral and glass fibre, wood and plasterboard. One piece integrated connection flukes FasTLock Suspended Ceiling Grid features integrated connection flukes on all main runner and cross tee components. The connection flukes are an integral part of the component itself. This important feature provides a high level of connection strength and shear load capability creating a stronger more durable grid system, particularly when subjected to abnormal stress or loading. FasTLock Main Tee During manufacture, the connection tabs on all main runner and cross tee components are pressed as part of the component itself. Integrated connection flukes eliminate a potential weak point found in systems with stab connectors which are formed from a separate piece of steel and then riveted or fusion welded onto the components body. FasTLock Cross Tee Tested and appraised to New Zealand and Australian building standards, FasTLock Suspended Ceiling Grid will provide your building project with a high quality, versatile and performance tested suspended ceiling system. Design options FasTLock Suspended Ceiling Grid is available in two standard widths. FasTLock for general applications FasTLock 15 a minimalist option providing a less dominant appearance Colours FasTLock Suspended Ceiling Grid is stocked in white as standard. Black is available on an indent basis. Custom colours are also available subject to minimum production runs Material FasTLock Suspended Ceiling Grid is manufactured from double web hot dipped galvanised steel pre finished with a hard wearing polyester paint finish. ally stable Long term performance Environmental Sustainability FasTLock is modular, can be disassembled, relocated and reused. FasTLock components can be fully recycled at the end of life. FasTLock packaging is recyclable. 3

FasTLock FasTlock is a general purpose exposed ceiling grid suitable for square edge and tegular edge ceiling tiles. SQUARE TEGULAR FasTLock Main Runner length () height () width () TW2110 3600 0.35 25 90 32 FasTLock 1200 Cross Tee length () height () width () TW2120 1200 0.35 50 60 20 FasTLock 600 Cross Tee length () height () width () TW2130 600 0.35 75 45 13.5 Perimeter Trim length () height () width () TW2140 3000 0.5 40 120 21 SYSTEM APPLICATION NOTE: Fixings used for direct hanging with wire are determined by building material above ceiling system (eg: concrete, timber or steel). Selected fixing ECOPLUS Ceiling Tiles Galvanised wire 2.5 FasTLock Cross Tee FasTLock Main Tee 4

FasTLock 15 FasTlock 15 is a narrow profile 15 exposed ceiling grid providing a refined appearance suitable for tegular edge ceiling tiles. TEGULAR 15 FasTLock 15 Main Runner length () height () width () TWN310 3600 15 0.35 25 90 29 15 FasTLock 15 1200 Cross Tee length () height () width () TWN320 1200 15 0.35 50 60 18 15 FasTLock 15 600 Cross Tee length () height () width () TWN330 600 15 0.35 75 45 12 Perimeter Trim length () height () width () TW2140 3000 0.5 40 120 21 SYSTEM APPLICATION NOTE: Fixings used for direct hanging with wire are determined by building material above ceiling system (eg: concrete, timber or steel). Selected fixing ECOPLUS Ceiling Tiles Galvanised wire 2.5 FasTLock Cross Tee FasTLock Main Tee 5

FasTLock SUSPENDED CEILING GRID Installation All ceilings must be designed in accordance with the requirements of AS/NZS 2785-2000. As part of this design process, seismic compliance to AS/NZS 1170.5 is required. Work shall comply with the installation requirements of AS/NZS 2785:2000 by appropriately qualified trade contractors. Installation should not coence until the building is weather tight. Refer to AS/NZS 2785-2000 4.2 The Main Runner shall be hung with a 2.5 straightened galvanised tie wire at maximum of 1200 centres. Cross Tees shall intersect and be positively locked into the Main Runner pre punched web slots. Cross tee alignment is achieved by locating the tees to the left hand side of the web slot on the adjoining section. Main Runner and Cross Tees spacing shall not exceed the design ceiling load or as may otherwise be required to prevent deflection greater than 1/360 of the span of the Cross Tees or Main Runners. Perimeter trim should be cut to length and fixed to the wall with suitable fasteners such as wafer head needle tipped screws at maximum of 600 centres. Quantity Guidelines Additional Loads Additional loads are not to be placed upon or carried by the suspension system. Ecoplus Systems recoend independent support of heavy fixtures is considered for safety purposes. Seismic Connection Strength The FasTLock Main Runner has been shown to have a load to pull-out (tension) strength in the order of 156 kg s force (1.5N); The FasTLock Cross Tee has been shown to have a load to pull-out (shear) strength in the order of 143kg s force (1.4N) Handling and Storage The proper safe handling and storage of all materials supplied by ECOPLUS Systems Ltd are the responsibility of the ceiling installer/contractor (competent and experienced in the installation of suspended ceiling systems). Dry storage must be provided on site for all the ECOPLUS System components. All components must be stored on a flat dry surface and protected from scratches or physical damage of any kind by/to other trades. Handling of the ECOPLUS FasTLock Suspended Ceiling Grid System s Components requires care and should be handled in a manner that will prevent distortion or physical damage. All accessories must be kept dry. Module Installation Method Approximate quanties required per 100m2 (waste allowance not included) Panel Size Main Runner Centres Hanger Centres Main Runner 1200 Cross Tee 600 Cross Tee Hanger 1200 x 600 pieces 1200 600 1200 1200 23 48 70 140 600 x 600 278 pieces 1200 600 1200 1200 23 48 278 70 140 This chart provides an approximate quantity for guidelines only. Perimeter trim will vary dependant on room geometry 6

ECOPLUS SYSTEMS C O N T A C T sales@ecoplus-systems.com ecoplus-systems.com PO Box 105577 Auckland City Auckland 1143 7