Analysis of Night Ventilation Potential for Residential Buildings in Hot-Humid Climate of Malaysia

Similar documents
Field Investigation of Indoor Thermal Environments in Traditional Chinese Shophouses with Courtyards in Malacca

A Preliminary Study of Thermal Comfort in Malaysia's Single Storey Terraced Houses

Summer thermal comfort in traditional buildings of the 19th century in Florina, north-western Greece

Indoor Thermal Environment in Residential Buildings at Different Micro-Climates in Malaysia

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

317: Thermal performance of houses located in Florianópolis, southern Brazil

Chapter 7. Passive Solar Contents

Sustainable Flat Roof Pond System in Tropical Climate of Surabaya

Passive cooling effect of building features in traditional Japanese buildings

UHI and Thermal Performance of Office Buildings in Bangkok

REAL-TIME CONTROL OF OCCUPANTS THERMAL COMFORT IN BUILDINGS. Galway, Ireland

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

POTENTIAL DESIGN PARAMETERS FOR ENHANCING THERMAL COMFORT IN TROPICAL TERRACE HOUSE: A CASE STUDY IN KUALA LUMPUR

171: An urban office designed for the southern Brazilian climate

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Assessment of Passive Thermal Performance for a Penang Heritage Shop house

International Conference on Innovation Challenges in Multidisciplinary Research & Practice, December 2013, Kuala Lumpur, Malaysia.

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Research on indoor thermal environment of stilted buildings in Chongqing, China

A Comparative Study of the Thermal Comfort of Different Building Materials in Sana a

Understanding thermal mass

CHAPTER 1 INTRODUCTION

362: Indoor climate control effect of AAC panels as determined by house model measurements and simulations

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand

Passive Cooling Strategies in Greening Existing Residential Building in Hot Dry Climate: Case Study in Bahrain

Thermal Comfort Evaluation of HDB flats

Thermal Performance Simulation of Residential Building in Tropical Climate Case Study: Housing in Bandar Universiti, Malaysia

Potential of Indirect Evaporative Passive Cooling with Embedded Tubes in a Humid Tropical Climate Applications in a typical hot humid climate

Thermal Comfort in Architecture

Nocturnal natural ventilation for low and zero energy office buildings in Central Chile

THERMAL PERFORMANCE USING RADIANT BARRIER AND PHASE CHANGE MATERIAL IN ROOFS

CEILING TILE. Thermal Mass. Passive Cooling. Thermal Comfort

Intelligent tall building envelope technologies and design alternatives for comfort and energy efficiency in hot, arid climate

Available online at ScienceDirect. Procedia Engineering 169 (2016 )

Reducing energy demand in non-domestic buildings: integrating smart facades, ventilation, and surface heating and cooling

Evaluation methods for indoor environmental quality assessment according to EN15251

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

Perception of Thermal Comfort for Naturally Ventilated High School Classrooms in San Rafael, CA

A first look at the affect of outdoor planting on the indoor environment of St. Loyes Residence. David Coley. March 2011 Internal Document 776

SOLAR PASSIVE DESIGN: PRINCIPLES AND PRACTICE

Thermal comfort evaluation of natural ventilation mode: case study of a high-rise residential building

FULL YEAR PERFORMANCE SIMULATION OF A DIRECT-COOLED THERMAL STORAGE ROOF (DCTSR) IN THE MIDWEST

Cost-Benefit Analysis of Dwelling Retrofit Options

carbon-neutral architectural design Pablo La Roche CRC Press Taylor & Francis Croup Boca Raton London NewYork CRC Press is an imprint of the

Air Movement Preference and Thermal Comfort A survey in classrooms during summer season in Brazil

Design Strategies and Guide lines for Tropical Coast of Pakistan, Using Climate Consultant

Work Package 2: Performance of naturally ventilated buildings

IMPLEMENTATION OF ANALYTICAL MODELS FOR PASSIVE DOWN-DRAFT EVAPORATIVE COOLING (PDEC) TOWER WITH SPRAY SYSTEMS

Effects of window size and thermal mass on building comfort using an intelligent ventilation controller

Proceedings of Clima 2007 WellBeing Indoors

Bio Climatic Analysis of Bhubaneswar-An Investigation to Arrive Human Comfort through Natural Ventilation

Natural Ventilation Approached on Circular Courtyard Building in Hot Humid Climate

CAE 331/513 Building Science Fall 2017

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

Demonstration of Load Shifting and Peak Load Reduction with Control of Building Thermal Mass

Influence of Building Orientation on the Indoor Climate of Buildings

Energy Analysis of Using Thermal Mass in a Hot Humid climate

SUSTAINABLE BY PASSIVE ARCHITECTURE, USING COURTYARDS IN NON-DOMESTIC BUILDINGS IN SOUTHEAST QUEENSLAND

Applications of ECOTECT and HEED in building energy analysis - Case study: A typical tube house in Hanoi

Thermal Comfort Measurements in a Hybrid Ventilated Office Room

Thermal Comfort and Energy Consumption according to the Indoor Control Logic

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

Datasheet. Thermal Benefits of Solid Construction

PASSIVE SOLAR BUILDING DESIGN STRATEGIES IN LALITPUR, POKHARA AND DHARAN CITIES OF NEPAL

Thermal comfort in a 21st century climate

THE IMPACT OF BUILDING ORIENTATION ON ENERGY USE: A CASE STUDY IN BUNG HATTA UNIVERSITY, INDONESIA

International Journal of Civil and Environmental Engineering 3:2 2011

Thermal Comfort Zone for Thai People

Designing for Queensland s climate. Designing for Queensland s climate

Neutral humidity in low cost dwellings in arid climate

THE THERMAL PERFORMANCE EVALUATION OF A FUTURE CHINESE LOWENERGY APARTMENT WITHIN CHANGING CLIMATE IN HOT SUMMER AND COLD WINTER ZONE IN CHINA

ACCEPTED FOR PUBLICTION AUTHORS SUBMISSION VERSION. Please cite the RPG version of this paper using the following DOI: /j.buildenv

Thermal Performance of Toplighting Systems in a Hot and Humid Climate: Thailand

Analysis of Heat Gain in Computer Laboratory and Excellent Centre by using CLTD/CLF/SCL Method

Performance Evaluation Of Thermally Activated Glass Fibre Reinforced Gypsum Building Equipped With Desiccant System

SET. An analysis of thermal comfort in primary schools in Vietnam BOLOGNA. Thi Ho Vi LE 1, Mark GILLOTT 2, Lucelia RODRIGUES 3

BEEP Guidelines for Energy Efficient Design of Multi-Storey Residential Buildings

Thermal comfort and occupant adaptive behaviour in university offices with cooling and free running modes

Social Housing in Costa Rica s Warm Humid Climate Strategies & considerations for passive design

GREEN AND COOL ROOFS URBAN HEAT ISLAND MITIGATION POTENTIAL IN EUROPEAN CLIMATES FOR OFFICE BUILDINGS UNDER FREE FLOATING CONDITIONS

DEVELOPING A CONCEPTUAL MODEL FOR PAS- SIVE COOLING IN BUILDINGS IN THE TROPICS A STUDY OF MARITIME MUSEUM, GALLE, SRI LANKA

Thermal comfort conditions in outdoor spaces

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

Evaluation of natural ventilation systems in a landscaped office.

Thermal Performance of Solar Heating System with Water Floor

Optimizing Indoor Environments for Occupant Satisfaction. Presented by: Kelli Goldstone April 2016

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Design and retrofitting of a hybrid building in Athens

GREEN CONCEPT OF THERMAL COMFORT DESIGN FOR SUSTAINABLE HOUSING IN THE TROPICS: Learning from Thermal Comfort in School Buildings 1 INTRODUCTION

THE PTM ZEO BUILDING

Part 1 Review Questions on material covered in Midterms I & II

CHAPTER 6 CONCLUSION

Deakin University gratefully acknowledges permission of the Australian and New Zealand Solar Energy Society to publish these papers

SMART PASSIVE COOLING SYSTEMS FOR SUSTAINABLE ARCHITECTURE IN DEVELOPING COUNTRIES: USING THE GAP TO BRIDGE THE GAP

A STUDY OF WALL SURFACE TEMPERATURE VARIATIONS FOR HOUSING IN MODERATE CLIMATES

An Assessment of Thermal Comfort in Hot and Dry Season (A Case Study of 4 Theaters at Bayero University Kano)

International Transaction Journal of Engineering, Management, & Applied Sciences & Technologies.

International Transaction Journal of Engineering, Management, & Applied Sciences & Technologies.

Transcription:

PLEA2009 - th Conference on Passive and Low Energy Architecture, Quebec City, Canada, 22- June 2009 Analysis of Ventilation Potential for Residential Buildings in Hot-Humid Climate of Malaysia DORIS TOE HOOI CHYEE 1, TETSU KUBOTA 2 1 School of Architecture, Building and Design, Taylor s University College, Petaling Jaya, Malaysia 2 Department of Development Technology, Graduate School for International Development and Cooperation, Hiroshima University, Hiroshima, Japan ABSTRACT: This paper discusses the potential of applying night as a passive cooling technique for Malaysian terraced houses based on the results of a full-scale field experiment. The results revealed that night provides better diurnal and nocturnal air temperature reductions than daytime, full-day and no. improves thermal comfort more than the other conditions based on operative temperature. However, further measure to lower indoor humidity such as by dehumidification or to increase indoor air velocity such as by fan may be required to improve the thermal condition in the night ventilated room in terms of SET*, especially in the daytime. Ceiling insulation may increase the cooling potential of night in Malaysian terraced houses. Keywords: passive cooling, night, natural, thermal comfort, hot-humid climate INTRODUCTION Many developing nations have been facing increasing energy consumption due to rapid urbanization and economic growth in the recent decades. In Malaysia, its urban population rose from 27% in 19 to 67% in 2005 [1] while the final energy demand in 2000 recorded a fivefold increase from 19 level [2]. It is reported that residential and commercial buildings account for almost half of the total electricity use in the country as of 2002 [2]. Since Malaysia and many other developing nations experience year-round hot conditions, it can be projected that reducing air-conditioning in buildings would contribute largely towards lowering energy use, especially in urban areas. is a notable passive cooling technique for well-insulated, high mass buildings [3]. This technique utilizes the nocturnal ambient air to cool the structural mass of a building via convection. The cooled structural mass may maintain lower indoor temperatures on the following day if the building is closed during the daytime [3]. To this effect, many researchers have noted that night effectively reduces daytime indoor air temperature in various types of buildings and climates. These studies extensively covered office buildings in moderate climate [4-7] and other test buildings in hot-arid climate [8]. The same studies [4, 7] noted that the efficiency of night highly depends on the building and climatic parameters as well as the rate at night. In comparison, night has received far less attention in the hothumid tropics with relatively few studies which addressed this technique. is also rarely applied by present urban households in Malaysia, who mostly close windows at night and open them during the daytime, as revealed in a previous survey [9]. According to the survey, the majority of present households in Malaysian terraced houses apply daytime and night-time air-conditioning mainly in bedrooms [9]. As indicated above, the cooling efficiency of night technique differs in different buildings and climatic regions. Thus, despite the extensive developments of night techniques already established in moderate and hot-arid climates, the effectiveness and applicability of night for Malaysian residential buildings is yet to be determined, in both research and practice. This paper discusses the potential of applying night as a passive cooling technique for Malaysian terraced houses based on the results of a full-scale field experiment. In Malaysia, the terraced house is the most common type of housing in urban areas 44% of the urban housing units nationwide are terraced houses in 2000 [10]. Unlike the lightweight Malaysian traditional houses, modern urban houses in Malaysia are mainly constructed of heavyweight materials such as concrete and brick. As such, night may be a suitable technique for these houses. This paper firstly compares the effects of night with daytime, full-day and no on indoor thermal environment in the master bedrooms of the case study

PLEA2009 - th Conference on Passive and Low Energy Architecture, Quebec City, Canada, 22- June 2009 houses. Secondly, this paper examines the effect of heat from the ceiling in Malaysian terraced houses based on the vertical temperature distribution analysis. House 1 House 2 METHODS A field experiment was conducted in two adjacent and identical two-storey terraced houses (Figs. 1 and 2) in the city of Johor Bahru from June to August 2007 to compare the indoor thermal conditions under different natural strategies. Johor Bahru is the second largest city in Malaysia based on population count [10]. Its monthly mean air temperature and humidity are generally uniform throughout the year, which is typical of most Malaysian towns. Both case study houses are considered to represent the typical Malaysian terraced houses. The selected houses are high thermal mass buildings. The building structure is reinforced concrete with plastered brick walls of 0mm thickness for party walls and 140mm thickness for other walls. The thermal mass of the master bedrooms was estimated to be 1100kg/m². The concrete roof tiles are laid with a thin layer of double-sided aluminium foil underneath as radiant barrier. The ceiling for the first floor is 4mm thick cement boards without insulation. The floors are reinforced concrete slab, and finished with ceramic tiles on the ground floor and timber strips on the first floor. All windows are either casement or sliding type and constructed of 5mm thick single-glazed clear glass. A clerestory window of fixed glass louvers is available above the family area on the first floor. During the experiment, the houses were empty of furniture and unoccupied. In the present experiment, three cases are included as outlined in Table 1. Cases 1-3 compare night with daytime, no and full-day respectively. Daytime was obtained by opening all windows from 8 a.m.-8 p.m. and closing them from 8 p.m.-8 a.m., to emulate the current window opening behaviour [9]. In contrast, all windows were closed from 8 a.m.-8 p.m. and opened from 8 p.m.- 8 a.m. for night. On the day before each case, all windows in both houses were opened equally from 8 a.m.-8 a.m. (h) so that their indoor thermal conditions would be similar at the start of respective cases. Measurements of indoor thermal environment were taken in the master bedrooms (first floor) and living rooms (ground floor) of the two houses (Fig. 2). The floor-to-ceiling height of the rooms is m. The measured parameters at m height above floor in the master bedrooms are air temperature, relative humidity, air velocity and globe temperature, for the analysis of thermal environment. The data loggers used are Delta Ohm (DO9847) and Innova AirTech Instruments A/S Figure 1: View of the case study houses. YARD MULTIPURPOS E ROOM DINING LIVING TURFING House 1 House 2 6.7m WET DRY STORE CAR PORCH WET DRY STORE CAR PORCH MULTIPURPOS E ROOM DINING LIVING TURFING Figure 2: Floor plans of the case study houses. Table 1: Ventilation conditions for Cases 1-3. YARD House 1 House 2 Indoor measuring point Weather station Case House 1 House 2 1 Daytime 2 No 3 Full-day 13.1m MASTER BEDROOM MASTER BEDROOM (Type 1221). In addition, air temperature measurements were taken at 0.6m, 2.4m and 2.9m in the master bedrooms and 0.6m, m and 2.4m in the living rooms for vertical temperature distribution analysis. Floor and ceiling surface temperatures were also recorded on both floors. All indoor measurements were logged automatically at 10-minute intervals. A weather station (EASIDATA Mark 4, Environdata) was placed in the immediate outdoor of House 2 (Fig. 2) to record the ambient air temperature, relative humidity, wind speed and direction, global horizontal solar radiation, rainfall and barometric pressure throughout the experiment. FAMILY BEDROOM 3 BEDROOM 2 BEDROOM 2 BEDROOM 3 FAMILY

PLEA2009 - th Conference on Passive and Low Energy Architecture, Quebec City, Canada, 22- June 2009 RESULTS AND DISCUSSION THERMAL ENVIRONMENT ANALYSIS This section focuses on measurement results at m height above floor in the master bedrooms (see Fig. 2). Fig. 3 shows the measured air temperature and relative humidity with the corresponding outdoor conditions during Cases 1-3. As shown in the figure, the occurrence of rain before noon affects the outdoor air temperature patterns, in particular the peak temperatures considerably. It can be seen that the measured air temperature in night condition was generally lower than those of daytime, no and full-day conditions during the six-day measurement for each case (Fig. 3). In order to further evaluate the cooling potential of night compared to the other conditions, the following analysis employed only data of fair weather days, which recorded relatively high outdoor air temperature. Fig. 4 shows the hourly mean air temperature on the fair weather days of respective cases. Maximum outdoor air temperature averaged -35 C while its minimum averaged -25 C (Fig. 4). In all, it was observed that night lowered the peak indoor air temperature by C, compared to both daytime and fullday conditions (Fig. 4ac). also lowered nocturnal indoor air temperature by C more than the daytime and no conditions on average (Fig. 4ab). When the daytime was applied in Case 1, the maximum indoor air temperature reached 3 C, which is only about C lower than that of the outdoors (Fig. 4a). In contrast, maximum air temperature in the night ventilated room was reduced to.5 C (Fig. 4a). It can be deduced from the above results that diurnal air temperature in the daytime ventilated room was close to the outdoors mainly due to its opened window condition which allowed outdoor hot air into the house. Furthermore, the heat from outdoor air was stored in the building structures and radiated to the indoor spaces at night. As windows were closed during night-time, the heat was confined in the house and nocturnal indoor air temperature in the daytime ventilated room maintained high at.0 C on average (Fig. 4a). In comparison, opened window condition at night allowed the natural flow of cooler ambient air into the house, which reduced nocturnal indoor air temperature in the night ventilated room to.0 C on average (Fig. 4a). When no was applied in Case 2, the nocturnal indoor air temperature was also maintained high at.5 C on average (Fig. 4b), which is similar to the daytime condition. It was found that without night cooling, the maximum air temperature in unventilated room is C higher than the night ventilated one although windows were closed during the daytime (Fig. Solar Radiation (W/m²) 38 1000 40 0 0 400 200 0 Rain period Daytime Daytime 13/7 14/7 15/7 16/7 17/7 18/7 Date / Time a) Case 1: Daytime vs. Solar Radiation (W/m²) 38 1000 40 0 0 400 200 0 Rain period No No 29/6 /6 1/7 2/7 3/7 4/7 Date / Time b) Case 2: No vs. Solar Radiation (W/m²) 38 1000 40 0 0 400 200 0 Rain period Full-day Full-day 6/7 7/7 8/7 9/7 10/7 11/7 Date / Time c) Case 3: Full-day vs. Figure 3: Measurement results at m in the master bedrooms for Cases 1-3.

PLEA2009 - th Conference on Passive and Low Energy Architecture, Quebec City, Canada, 22- June 2009 40 40 40 Daytime No No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Full-day Daytime Full-day 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 a) Case 1: Daytime vs. b) Case 2: No vs. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 c) Case 3: Full-day vs. Figure 4: Hourly mean air temperature and relative humidity for Cases 1-3. Operative Temperature SET* Operative Temperature SET* Operative Temperature SET* 22 22 22 % acceptability % acceptability Daytime 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 a) Case 1: Daytime vs. No No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 b) Case 2: No vs. Full-day Daytime Full-day 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 c) Case 3: Full-day vs. Figure 5: Hourly mean operative temperature and standard effective temperature (SET*) for Cases 1-3. 4b). When the full-day was applied in Case 3, diurnal indoor air temperature was similar to the pattern of the daytime ventilated one while nocturnal indoor air temperature was still C higher than that of the night ventilated room (Fig. 4c). As before, the building structure was heated more when windows were opened during the daytime. As the mean outdoor wind speed dropped from 0.6m/s during the day to 0.1m/s at night, the night-time rate might be insufficient to cool the heated structure of the full-day ventilated house properly at night due to its high thermal capacity. On account of the thermal mass of the room, the night technique was effective in lowering the peak indoor air temperature by 3.5-4.0 C and delaying it by 2 hours from the outdoors on fair weather days (Fig. 4). However, it should be noted that nocturnal air temperature in the night ventilated room was still C higher than the outdoors (Fig. 4), probably due to the same reasons of low rate at night and high thermal capacity. On the other hand, the measurement results reveal that the air temperature reductions obtained by the night were accompanied by the increase in relative humidity (Fig. 3). The indoor relative humidity reached 65-% when the night was applied on fair weather days (Fig. 4). In this aspect, full-day and daytime were able to control diurnal humidity level to about 15% RH lower than night (Fig. 4ac), but at the expense of the aforementioned cooling effects. To examine whether the night is able to provide thermal comfort, the measurement results were transformed into two thermal indices, i.e. operative temperature and standard effective temperature (SET*). The Adaptive Comfort Standard (ACS) prescribed recently by ASHRAE [11] is considered one of the appropriate methods for determining acceptable thermal conditions in naturally ventilated spaces. Since the comfort criteria is based on operative temperature, SET*

PLEA2009 - th Conference on Passive and Low Energy Architecture, Quebec City, Canada, 22- June 2009 is also used in this analysis to take evaporative heat exchange between the occupant and the environment into account, in consideration of the high humidity conditions. In SET* calculation, the metabolic rate of met and clothing insulation of clo were applied. Fig. 5 presents the hourly mean operative temperature and SET* for respective cases. According to the ACS [11], the acceptable operative temperature limits for % and % acceptability were found to be 23- C and - 29 C respectively, based on the mean monthly outdoor air temperature during the experiment period. As indicated in Fig. 5, the night technique was found to provide more acceptable operative temperature than the other conditions for the whole day. In all cases, operative temperature in the night ventilated room is well within the acceptable limits, mainly during the night hours from 9 p.m.-12 noon (Fig. 5). In comparison, operative temperature in other conditions did not meet the % acceptability limits until past midnight (Fig. 5). Thus, it can be seen that there is a huge potential for reducing the night-time airconditioning in Malaysian terraced houses if occupants adapt to the night technique from their current behaviour of daytime. Still, operative temperature in the night ventilated room exceeded the % upper limit in the afternoon by up to C (Fig. 5). In fact, maximum operative temperature in each room was - C higher than the respective maximum air temperature (cf. Figs. 4 and 5), signifying the occurrence of excessive radiant heat gain during the peak period. Furthermore, in terms of SET*, the nocturnal cooling effect of the night technique is still seen in all cases (Fig. 5). However, the night does not provide better diurnal thermal conditions compared to daytime and full-day when the evaporative heat loss is considered in SET*. Maximum SET* in the night ventilated room is C and about C higher than the daytime ventilated and full-day ventilated ones respectively (Fig. 5ac), most likely due to the increase in diurnal humidity level when windows were closed. Besides, when windows were opened during the daytime, indoor air velocity reached about 0.3m/s on average whereas still air condition occurred in the night ventilated room. Thus, in order to improve the diurnal thermal condition in the night ventilated room in terms of SET*, further measure to lower indoor humidity such as by dehumidification or to increase indoor air velocity such as by fan may be required. Otherwise, full-day may be the better option even though the night-time thermal condition would be slightly warmer than the night condition. VERTICAL TEMPERATURE DISTRIBUTION ANALYSIS This section examines the effect of heat from the ceiling based on the vertical temperature distribution in the case study houses. Fig. 6 presents the average air and surface temperatures between 12 noon and 8 p.m. at respective measurement heights for Cases 1-3. The windows in the night ventilated house were closed during this period. As shown in Fig. 6, the ceiling surface temperature on the first floor in the night ventilated house was similar to the outdoor air temperature, even though the temperatures at all other measurement points in the house were much lower. It was 2-3 C higher than the floor surface and air temperatures of the same room (Fig. 6). In fact, the first floor ceiling surface temperature was almost same in both houses under the different conditions (Fig. 6). Daytime First floor Daytime Ground floor No First floor No Ground floor Full-day First floor Full-day Ground floor 22 23 25 27 29 31 33 35 Temperature 22 23 25 27 29 31 33 35 Temperature 22 23 25 27 29 31 33 35 Temperature a) Case 1 b) Case 2 c) Case 3 Figure 6: Vertical distribution of average air and surface temperatures between 12 noon and 8 p.m. for Cases 1-3.

PLEA2009 - th Conference on Passive and Low Energy Architecture, Quebec City, Canada, 22- June 2009 The above results imply that the ceiling was considerably heated, probably by the heat from solar radiation received at the roof during the daytime. Consequently, the heated ceiling passed the heat to the air on the first floor via convection. The heated ceiling also probably radiated heat into the room and thus increased the operative temperature further. This process might contribute to create the diurnal thermal discomfort in the night ventilated master bedroom. As presented in the previous section, according to the ACS, warm discomfort condition was seen in the night ventilated master bedroom in the afternoons: 2 p.m.-6 p.m. in Case 1, 12 noon-8 p.m. in Case 2, and 2 p.m.-9 p.m. in Case 3 (see Fig. 5). In comparison, in addition to the heated ceiling, with outdoor hot air further increased the air temperature in the daytime ventilated and full-day ventilated master bedroom, compared to the night ventilated one (Fig. 6ac). It can be seen that the ground floor was cooler than the first floor especially when windows were closed, i.e. in the night and no conditions (Fig. 6). The air temperature at m on the ground floor was 1 C lower than that of the first floor when the night was applied (Fig. 6). This air temperature difference between floors is probably due to the heat from the ceiling on the first floor as discussed above. Considering that the ceiling was not insulated, applying thermal insulation to the ceiling may reduce the air temperature on the first floor to that of the ground floor, which would increase the cooling effect of the night technique by 1 C on average in the afternoon period. CONCLUSIONS (1) was found to be better than daytime, full-day and no in terms of air temperature reductions during the daytime and night-time. It was observed that night lowered the peak indoor air temperature by C, compared to daytime and fullday conditions. also lowered nocturnal indoor air temperature by C more than the daytime and no conditions on average. (2) provides more acceptable operative temperature than the other conditions for the whole day. According to the Adaptive Comfort Standard, night would provide thermal comfort well, mainly during the night hours from 9 p.m.-12 noon. (3) However, further measure to lower indoor humidity such as by dehumidification or to increase indoor air velocity such as by fan may be required to improve the diurnal thermal condition in the night ventilated room in terms of SET*. Otherwise, full-day may be the better option even though the night-time thermal condition would be slightly warmer than the night condition. (4) It was found that the heat from the ceiling probably caused the air temperature on the first floor to be higher than that of the ground floor by 1 C on average in the afternoon period when the night was applied. Applying thermal insulation to the ceiling may increase the cooling potential of the night technique in Malaysian terraced houses. ACKNOWLEDGEMENTS. This research project was supported by a grant from the Sumitomo Foundation 2006 and conducted under Vote 73712, Research Management Center, Universiti Teknologi Malaysia. This research was conducted when the present authors were affiliated to Universiti Teknologi Malaysia in Skudai, Malaysia. The authors would like to thank Prof. Dr. Supian Ahmad, Prof. Dr. Hamdan Ahmad, Dr. Ossen and Ms. Halimah of Universiti Teknologi Malaysia for their generous supports. REFERENCES 1. Malaysia, (1966-2005). Malaysia Plans 1 st 8 th. Economic Planning Unit. 2. Malaysia, (2002). National Energy Balance Malaysia 2002. Ministry of Energy, Communications and Multimedia Malaysia. 3. Givoni, B., (1994). Passive and low energy cooling of buildings. New York: Van Nostrand Reinhold. 4. Blondeau, P., Spérandio, M., and Allard, F., (1997). for building cooling in summer. Solar Energy, 61(5): p. 7-335. 5. Breesch, H., Bossaer, A., and Janssens, A., (2005). Passive cooling in a low-energy office building. Solar Energy, 79: p. 682-696. 6. Geros, V., Santamouris, M., Tsangrasoulis, A., and Guarracino, G., (1999). Experimental evaluation of night phenomena. Energy and Buildings, 29: p. 141-154. 7. Pfafferott, J., Herkel, S., and Jäschke, M., (2003). Design of passive cooling by night : Evaluation of a parametric model and building simulation with measurements. Energy and Buildings, 35: p. 1129-1143. 8. Givoni, B., (1991). Performance and applicability of passive and low-energy cooling systems. Energy and Buildings, 17: p. 177-199. 9. Kubota, T., and Ahmad, S., (2005). Questionnaire survey on behavior for natural and electricity consumption in terraced houses: A case study of Johor Bahru City. In Proceedings of the 8 th International Conference of the Asian Planning Schools Association. Penang, Malaysia, September 11-14. 10. Malaysia, (2005). General report of the population and housing census. Department of Statistics Malaysia. 11. ASHRAE, (2004). ASHRAE Standard 55-2004, Thermal Environmental Conditions for Human Occupancy. Atlanta: ASHRAE.