Inspection Report. Dr. Lucas J. Property Address: 1234 Main St Chicago IL Main St. Chicago, IL. Above Grade Home Inspectors

Similar documents
Alabama Home Inspections

Inspection Report. Baruch Weiner. Property Address: 123 Main St. Monsey NY Capital Property Inspection Corp.

FAIRA TRANSPARENCY REPORTS S Proctor St, Tacoma, WA March 29 th, 2017

ARIZONA. American Society of Home Inspectors. Arizona Chapter. Adopted by AZ ASHI Effective January 1, and

9) Home Inspection: As defined in Section 1-10 of the Act.

TITLE 68: PROFESSIONS AND OCCUPATIONS CHAPTER VIII: DEPARTMENT OF FINANCIAL AND PROFESSIONAL REGULATION

Inspection Report. Mr. Valued Customer. Property Address: 1234 Anywhere Ave. Grand Rapids, MI Discovery Inspections

Section Standards of Practice. a) The following are terms commonly used in the writing of home inspection reports.

Inspection Report. Virgina Smith. Property Address: 123 Anywhere Street. Foley Al Inspected Property. Precise Home Inspections LLC

Inspection Report. Frank Homeowner. Property Address: 123 Your Street Tulsa, OK Assured Home Inspectors. Drew Sleezer

Inspection Report. Mr. Frank Borey. Property Address: 9907 Summit Ave NE. Rockford MI Key Home Inspections, LLC.

Inspection Report. Property Address:

New Jersey Home Inspection - Standards of Practice

COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ PHONE:

Inspection Report. Mr. Gregory Mr. Infrared Inspections sample report sample. Property Address: 2239 W. 24th St. Los Angeles CA

1234 Main St. Buyer Name. Table of Contents

FAIRA TRANSPARENCY REPORTS th Street Southeast, Puyallup, WA, June 1 st, 2017

FAIRA TRANSPARENCY REPORTS th St S, Roy, WA June 15 th, 2017

The Standards of Practice

Inspection Report. Mr. Your Name. Property Address: 1234 Any street. Atlanta Ga Regency Crest court. Nehemiah Inspection Services

Inspection Report Mr. Justin Hughey Mr. Tim Ratcliff Property Address:

Inspection Report. Prepared for: Yossi Berg. Property Address: 4925 Diggers Way Sugar Hill, GA. Date: July 20, 2011

Inspection Report. Auction Company of America. Property Address: 209 Lighthouse View Dr. Stevensville MD Street View

Inspection Report. James Customer Jenny Customer. Property Address: 9999 Main Street Greenwood IN Crawford Home Inspections

N.J.A.C. 13: NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2015 by the New Jersey Office of Administrative Law

Inspection Report. Mr. Joe Sampleton. Property Address: 1111 sample drive Minden Nv Marshall Inspection

Inspection Report. Mrs. Sample Report. Property Address: 123 Sample Street Bonita Springs FL AccuSpec Home Inspection Services, LLC

1234 Main St Denver CO 80210

Inspection Report. Mr. Jane Doe. Houseck. Property Address: 123 Anywhere st Irmo sc. Wes Hobgood SC Anywhere st Page 1 of 30

REPORT CHECKLIST SUPPLEMENT

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

Inspection Report. Prepared For: Rich Land Sandy Land. Property Address: 479 Lewitt. Mayville, MI. Sherlock Home Inspectors, Inc.

FAIRA TRANSPARENCY REPORTS College St SE, Lacey, WA April 28 th, 2017

Madison's Home Inspections

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS Westmore Dr E, Puyallup, WA May 2 nd, 2017

HOME INSPECTORS CHAPTER

Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012

2002 CAPHI (BC) Apartment Style Condominium Standards of Practice

SOUTH CAROLINA HOME INSPECTOR STANDARDS OF PRACTICE

Inspection Report. Prepared for: Tonia Mann. Property Address: 1295 Greyland Hills Drive Lawrenceville, GA Date: April 24, 2012

a) For the purposes of this Section, the terms listed below shall mean:

Inspection Report. 1 of 8

Inspection Report. Mr. and Mrs. First Name Last Name. Property Address: Your Inspection Property CALGARY AB T2X 0N7.

Inspection Report. Prepared for: Tonia Mann. Property Address: 56 Riverview Place Douglasville, GA Date: September 19, 2012

Home Inspection Report

UP AND UP HOME INSPECTIONS

Inspection Report. Jane Smith. Property Address: 1 Main st Waterbury Vt True North Property Inspections LLC

Inspection Report. American Homebuyer. Property Address: 200 Pleasant Street. Hometown RI Hearthstone Home Inspection

Inspection Report. Joe Lundequam. Property Address: Sample Inspection Report Stillwater MN Paladin Inspection Services

Inspection Report. Rick and Anne Randell. Property Address: 91 Farningham Crescent Toronto ON M9B 3B7. The Home Inspector TM

3D Home Improvement and Inspection Services, Inc

Inspection Report. Prepared for: Yaron Sternberg. Property Address: 926 Hemingway Road Stone Mountain, GA. Date: April 15, 2011

Inspection Report. Prepared For: Property Address: INSPECTION HOME SERVICES INC.

Inspection Report. Bethany Villarroel-Meneses. Property Address: 340 Balsam Rd Williamstown New Jersey. JM Property Inspection LLC

Inspection Report. John Customer. Property Address: 123 Sample St. Louisville KY HomeWise Inspection Services

Inspection Report. Prepared For: Olive Branch. Property Address: 906 W Maple. Bay City, MI. Sherlock Home Inspectors, Inc.

Home Inspection Report

Mississippi Home Inspector Regulatory Board Standards of Practice and Code of Ethics

Standards of Practice for Building Inspections, recognized by the OACIQ

Inspection Report. Your Name. Property Address: Your Address Medicine Hat AB

Summary of Oregon Home Inspector Certification Law (ORS 701) and Standards of Practice for Home Inspections

Inspection Report. Home Buyer. ProCheck. Property Address: 1234 Your New Home Northern CO. K.C. Johnson Fort Collins, CO

HomeBuyers Inspection HBI. Inspection Report. Property Address: Danica Sample Stara Lane, Hendersonville, NC

Inspection Report. Prudence Johnson. Property Address: 2622 Miller Road Hillsborough NC Jamey Tippens, LLC

SC Standards Of Practice for Home Inspectors

CONNECTICUT HOME INSPECTION LICENSING BOARD Department of Consumer Protection 165 Capitol Avenue, Hartford, CT 06106

The Inspector. Property Inspection Report

Inspection Report. Steve Sample. Property Address: 1359 W Baron Circle. Suburban CO. Inspection Perfection inc

Inspection Report. Mr. and Mrs. John Doe. Property Address: 111 Smith St Anytown MI. Caverley Home Inspections

Inspection Report. Happy Home. Property Address: 123 Happy Home Road Jackson MS Pam Pybas, CMI NH Haylee Vomberg, MHIB 0705

Inspection Report. Campbell Property Inspections

HOME INSPECTOR MINIMUM STANDARDS OF PRACTICE. A. In this chapter, the following terms have the meaning indicated.

Inspection Report. Sample Buyer. Property Address: 3000 Nassau Drive Vero Beach FL Seacrest Home Inspections LLC

Inspection Report. John Doe. Property Address: 123 Sample St Jacksonville Fl 32207

Inspection Report. Sample House. Property Address: 310 Inspection Road Hometown FL. HousePro Inspection Services

ASHI STANDARD OF PRACTICE FOR HOME INSPECTIONS

Inspection Report. Happy Homeowner. Property Address: 45 Oak Dr. Charleston SC American Inspection Service, Inc.

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ

component was performing its intended function; installation and condition were appropriate for age and use.

Boise Home Inspection Report

Inspection Report. Prepared For: Mr. Rick Sample. Property Address: 123 Main Street Any Town, IL Inspected by:

Inspection Report. Quakertown Fire Company. Property Address: 2 Perryville Rd Union Twp NJ Perryville Rd. New Jersey Property Inspections

FAIRA TRANSPARENCY REPORTS nd Ave NE, Seattle, WA March 17, 2016

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048

Friendly Inspection Services

LOUISIANA STATE BOARD of HOME INSPECTORS (LSBHI) Additional information at:

Inspection Report. Mr. Example Report Mr. Example Report. Property Address: 1945 Basitle Way Rochester NY Veterans Home Inspection

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

Property Inspection Report

Property Inspection Checklist

FAIRA TRANSPARENCY REPORTS Bayview Edison Rd., Mt Vernon, WA February 27 th, 2017

The Home Doctor, Inc.

WEST MICHIGAN HOME INSPECTORS LLC 3134 Chamberlain SE Grand Rapids MI

2002 CAPHI (BC) Townhouse Standards of Practice Page 1

Title 09 DEPARTMENT OF LABOR, LICENSING, AND REGULATION

All Pro Home Inspection. Home Report South Your Town

Hogue Home Inspections

Transcription:

Inspection Report Dr. Lucas Property Address: 1234 Main St Chicago IL 60606 1234 Main St. Chicago, IL Above Grade Home Inspectors Stephen Santos 450.011381 124 W Polk St Chicago, IL 60605 773.610.9883

Table of Contents Cover Page...1 Table of Contents...2 Intro Page...3 1 Roofing...4 2 Exterior...7 3 Garage...12 4 Interiors...14 5 Structural Components...19 6 Plumbing System...20 7 Electrical System...27 8 Heating / Central Air Conditioning...30 9 Insulation and Ventilation...33 10 Built-In Kitchen Appliances...35 Invoice...37 Back Page...38 1234 Main St Page 2 of 38

Date: 9/28/2014 Time: Report ID: Property: 1234 Main St Chicago IL 60606 Customer: Dr. Lucas Comment Key or Definitions Real Estate Professional: Your name here! The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property. Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear. Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting. Not Present (NP) = This item, component or unit is not in this home or building. Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement. Type of building: Single Family (2 story) Approximate age of building: Over 50 Years Weather: Light Rain Ground/Soil surface condition: Wet Rain in last 3 days: Yes 1234 Main St Page 3 of 38

1. Roofing The home inspector shall observe: Roof covering; Roof drainage systems; Flashings; Skylights, chimneys, and roof penetrations; and Signs of' leaks or abnormal condensation on building components. The home inspector shall: Describe the type of roof covering materials; and Report the methods used to observe the roofing. The home inspector is not required to: Walk on the roofing; or Observe attached accessories including but not limited to solar systems, antennae, and lightning arrestors. Styles & Materials Roof Covering: 3-Tab fiberglass Chimney (exterior): Brick 1.0 Roof Coverings Viewed roof covering from: Ladder Items Sky Light(s): Two View from left side of house facing front. Shingles appear to be newer as they are even in between tabs. As roof shingles age the space between the tabs expands and the shingles begin to cup. 1.0 Item 1(Picture) Roof shingles 1.1 Flashings Comments: Inspected 1.1 Item 1(Picture) Missing flashing above front door 1.1 Item 2(Picture) Inconsistent flashing around skylight Front door is missing flashing which prevents water from entering between the top of the door and the inner frame. 1234 Main St Page 4 of 38

Flashing around skylight is lifting up in one corner, over time this could lead to possible water intrusion. Repair or replace by qualified roofing contractor. 1.2 Skylights, Chimneys and Roof Penetrations 1234 Main St Page 5 of 38

1.2 Item 1(Picture) Chimney spalling 1.2 Item 2(Picture) Chimney 1.2 Item 3(Picture) Leaning chimney The photo shows spalling on the brick near the top of the chimney and the center. Without proper repair the bricks may come loose over time and fall into the chimney creating an unsafe situation. Have a qualified contractor repair or replace. 1234 Main St Page 6 of 38

The chimney is leaning or has pulled away from home. A leaning chimney is considered unsafe until inspected by a structural engineer and anyone else needed such as a chimney sweep. I recommend a qualified structural engineer inspect and repair as needed. 1.3 Roof Drainage Systems 1.3 Item 1(Picture) Clogged gutter 1.3 Item 2(Picture) Gutter not attached Gutters need to be cleaned out in order to properly displace water from roof. The downspout is loose and needs securing to the wall at the left side of home (facing rear). The roof of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Roof coverings and skylights can appear to be leak proof during inspection and weather conditions. Our inspection makes an attempt to find a leak but sometimes cannot. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. 2. Exterior The home inspector shall observe: Wall cladding, flashings, and trim; Entryway doors and a representative number of windows; Garage door operators; Decks, balconies, stoops, steps, areaways, porches and applicable railings; Eaves, soffits, and fascias; and Vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The home inspector shall: Describe wall cladding materials; Operate all entryway doors and a representative number of windows; Operate garage doors manually or by using permanently installed controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meeting reasonable resistance during closing; and Probe exterior wood components where deterioration is suspected. The home inspector is not required to observe: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Fences; Presence of safety glazing in doors and windows; Garage door operator remote control transmitters; Geological conditions; Soil conditions; Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detached buildings or structures; or Presence or condition of buried fuel storage tanks. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility. Styles & Materials 1234 Main St Page 7 of 38

Siding Style: Brick Siding Material: Full brick Exterior Entry Doors: Steel Appurtenance: Sidewalk 2.0 Wall Cladding Flashing and Trim Driveway: Street Parking Items 2.0 Item 2(Picture) Caulking at room trim 2.0 Item 1(Picture) Light above front door. The fixture above the front door is loose which may allow water to enter into the building. Have a qualified electrician repair or replace. Caulking at the roof trim is dry and may fail to keep out water. Have qualified contractor repair or replace. 2.1 Doors (Exterior) 2.1 Item 1(Picture) Top shock at front door. 2.1 Item 2(Picture) Bottom shock at front door. 1234 Main St Page 8 of 38

Front entry door does not stay open, replace shock in order to prop door open. 2.2 Windows Comments: Inspected 2.2 Item 1(Picture) Rear window in kitchen, facing front of home. 2.2 Item 2(Picture) First floor left side facing rear of home 2.2 Item 3(Picture) Rear window missing glass. Multiple windows have broken screens, I recommend replacing them in order to keep out insects. Clean and lube window channels as they are difficult to open. Window at the rear of the building is missing two panes of glass. Replace. 1234 Main St Page 9 of 38

2.3 Decks, Balconies, Stoops, Steps, Areaways, Porches, Patio/Cover and Applicable Railings The wrought iron railings on steps at the front of home are rusted and deteriorated at bottom cleat. A more proper repair is needed to ensure stability or an injury might occur. A qualified contractor should repair or replace as needed. 2.3 Item 1(Picture) Railing at entrance. 2.4 Vegetation, Grading, Drainage, Driveways, Patio Floor, Walkways and Retaining Walls (With respect to their effect on the condition of the building) 1234 Main St Page 10 of 38

There is a negative slope at the right side (facing front) and can cause or contribute to water intrusion or deterioration. I recommend correcting the grade of the concrete walkway to drain water away from home. 2.4 Item 1(Picture) Ponding of water against the foundation. 2.5 Eaves, Soffits and Fascias 1234 Main St Page 11 of 38

2.5 Item 1(Picture) Detachment Metal soffit wrap if falling, repair or replace as necessary. The exterior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. 3. Garage Styles & Materials Garage Door Type: One manual 3.0 Garage Ceilings Garage Door Material: Fiberglass Items Auto-opener Manufacturer: N/A Extra Info : Garage door opener not present 1234 Main St Page 12 of 38

3.0 Item 1(Picture) Duct tape in garage 3.0 Item 2(Picture) Garage roof joist 3.0 Item 3(Picture) Garage Duct tape seems to be concealing something on the garage roof joist. Garage roof joists are not attached properly, repair or replace before attaching something heavy such as a garage door opener in order to prevent failure. 3.1 Garage Walls (including Firewall Separation) Signs of moisture intrusion on garage wall. Have a licensed contractor repair or replace. 3.1 Item 1(Picture) Signs of moisture intrusion on garage wall. 3.2 Garage Floor Comments: Inspected 3.3 Garage Door (s) 1234 Main St Page 13 of 38

SHK graffiti on exterior garage door. This is for your information only. 3.3 Item 1(Picture) Graffiti on garage door. 3.4 Occupant Door (from garage to inside of home) It seems that the door was shimmed with a piece of wood that was not completely cut flush with the frame. Repair or replace. 3.4 Item 1(Picture) Wood shim protruding from door frame. 3.5 Garage Door Operators (Report whether or not doors will reverse when met with resistance) Comments: Not Present There is no garage door opener present, door opens smoothly. 4. Interiors The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments. Styles & Materials Ceiling Materials: Gypsum Board Interior Doors: Hollow core Cabinetry: Wood Wall Material: Gypsum Board Window Types: Double-hung Countertop: Granite Floor Covering(s): Hardwood T&G Window Manufacturer: UNKNOWN 1234 Main St Page 14 of 38

Items 4.0 Ceilings Comments: 4.1 Walls Comments: 4.2 Floors Comments: Inspected Inspected Inspected Transition missing from wood floor to tile, this creates a trip hazard. Have qualified person repair or replace. 4.2 Item 1(Picture) Missing transition on floor 4.3 Steps, Stairways, Balconies and Railings 1234 Main St Page 15 of 38

4.3 Item 1(Picture) Basement railing missing. 4.3 Item 2(Picture) Handrail missing from rear entry door to main floor. The hand/guard rail for the stairs to lower and upper level are missing. A fall or injury could occur if not corrected. Handrails should be installed for safety. 4.4 Counters and Cabinets (representative number) The cabinet in the bathroom was not notched properly. This is for your information only. 4.4 Item 1(Picture) Bathroom cabinet first floor. 4.5 Doors (representative number) 1234 Main St Page 16 of 38

4.5 Item 1(Picture) Bathroom door vs toilet main floor 4.5 Item 2(Picture) Dead bolt on rear door. 4.5 Item 3(Picture) No doorstop. 1234 Main St Page 17 of 38

4.5 Item 4(Picture) No doorstop 4.5 Item 5(Picture) Lock on closet first floor. Very little clearance between the bathroom door and the toilet on the main floor. With natural contraction and expansion due to humidity, it is a possibility that the door may not function properly. Repair or replace. Dead bolt on rear door does not lock, repair or replace for safety concerns. Each door in this house is missing a doorstop that will allow the door handles to come into contact with the walls and cause damage. Have a qualified person install doorstops. Have qualified contractor properly seat the locks in the doors for optimal performance. 4.6 Windows (representative number) 1234 Main St Page 18 of 38

The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture and inspecting behind furniture, area rugs or areas obstructed from view. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. 5. Structural Components The Home Inspector shall observe structural components including foundations, floors, walls, columns or piers, ceilings and roof. The home inspector shall describe the type of Foundation, floor structure, wall structure, columns or piers, ceiling structure, roof structure. The home inspector shall: Probe structural components where deterioration is suspected; Enter under floor crawl spaces, basements, and attic spaces except when access is obstructed, when entry could damage the property, or when dangerous or adverse situations are suspected; Report the methods used to observe under floor crawl spaces and attics; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to: Enter any area or perform any procedure that may damage the property or its components or be dangerous to or adversely effect the health of the home inspector or other persons. Styles & Materials Foundation: Poured concrete Wall Structure: Brick Roof Structure: Not visible Attic info: No Storage Method used to observe Crawlspace: No crawlspace Columns or Piers: Wood piers Extra Info : Enclosed with new drywall, not visible. Roof-Type: Gable Items Floor Structure: Not visible Ceiling Structure: Not visible Method used to observe attic: Inaccessible 5.0 Foundations, Basement and Crawlspace (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) The concrete poured foundation wall in basement at the left side (facing front) has been repaired which appears adequate.. However, since opinions vary, I recommend a qualified structural engineer evaluate. 5.0 Item 1(Picture) Foundation wall repair. 5.1 Walls (Structural) 1234 Main St Page 19 of 38

5.2 Columns or Piers Comments: Not Inspected 5.3 Floors (Structural) Comments: Not Inspected Floors on the second level seem to have some sort of give to them in various areas. As if there is not a completely flat surface underneath the carpeting. Have a licensed contractor examine and suggest repair options. 5.3 Item 1(Picture) Hole underneath tester 5.4 Ceilings (Structural) 5.5 Roof Structure and Attic Comments: Not Inspected The structure of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. 6. Plumbing System The home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps. The home inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance. The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials. Styles & Materials Water Source: Public Plumbing Water Distribution (inside home): Copper Water Heater Power Source: Gas (quick recovery) Water Heater Location: Basement Water Filters: (We do not inspect filtration systems) Washer Drain Size: 1 1/2" Diameter (undersized) Water Heater Capacity: 40 Gallon (1-2 people) Plumbing Water Supply (into home): Galvanized (old) Plumbing Waste: Cast iron Manufacturer: BRADFORD-WHITE 1234 Main St Page 20 of 38

Items 6.0 Plumbing Drain, Waste and Vent Systems 1234 Main St Page 21 of 38

6.0 Item 1(Picture) Both sinks leaking in kitchen. 6.0 Item 2(Picture) Bathroom sink in basement. 6.0 Item 3(Picture) Basement sink w/out overrun. 6.0 Item 4(Picture) Sludge in sewer behind house. 1234 Main St Page 22 of 38

The basket strainers are leaking at the connections to the Kitchen sinks. Repairs are needed to stop leaking water from damaging the cabinet bottom or to eliminate moisture that may contribute to fungi growth. A qualified licensed plumber should repair or correct as needed. Bathroom sink in basement is leaking at the union of the bowl and the drain pipe. Repair or replace in order to prevent potential water damage. Sink in basement has no overrun protection due to design. Have a qualified person remove sludge from exterior sewer clean out to prevent future clogging. 6.1 Plumbing Water Supply, Distribution System and Fixtures 1234 Main St Page 23 of 38

6.1 Item 1(Picture) Toilet lid basement. 6.1 Item 2(Picture) Copper soldered to exterior water valve. 1234 Main St Page 24 of 38

6.1 Item 3(Picture) Exterior photo of hose valve that was soldered. The toilet seat toilet tank lid toilet seat is loose and needs to be secured at the downstairs bath. Repairs are needed A qualified licensed plumber should repair or correct as needed. Improper installation of a water supply valve. The pipe has been soldered when a fitting is required. 6.2 Hot Water Systems, Controls, Chimneys, Flues and Vents 1234 Main St Page 25 of 38

(1) The water heater needs to be secured. This is a safety issue and should be repaired. A qualified person should repair as necessary. The vent pipe on the water heater seems to have been repaired with metal tape, in order to prevent possible carbon monoxide leakage replace with proper piping. Have a qualified HVAC contractor repair or replace. Safety issue. 6.2 Item 1(Picture) Vent pipe above water heater. (2) The T&P (Test and Pressure) valve on water heater needs a 3/4 threaded pipe to extend within 6 inches of floor for safety. (PVC is not approved for hot water use). I recommend repair by a qualified person. 6.2 Item 2(Picture) 6.3 Main Water Shut-off Device (Describe location) The main shut off is the knob located on the front wall. This is for your information. 6.3 Item 1(Picture) Main water off in basement. 6.4 Fuel Storage and Distribution Systems (Interior fuel storage, piping, venting, supports, leaks) 1234 Main St Page 26 of 38

6.5 Main Fuel Shut-off (Describe Location) Main gas shut off. This is for your information. 6.5 Item 1(Picture) Main gas shut off 6.6 Sump Pump Comments: Not Present The plumbing in the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Washing machine drain line for example cannot be checked for leaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed and barely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waiting for closing) rust or deposits within the pipes can further clog the piping system. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. 7. Electrical System The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main over current device, and main and distribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their over current devices, and the compatibility of their ampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smoke detectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead or underground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The home inspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of a central system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over current device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment. Styles & Materials Electrical Service Conductors: Overhead service Copper 110 volt only Panel capacity: 100 AMP Panel Type: Circuit breakers 1234 Main St Page 27 of 38

Electric Panel Manufacturer: SIEMENS 7.0 Service Entrance Conductors Branch wire 15 and 20 AMP: Copper Items Wiring Methods: Conduit 7.1 Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels 7.1 Item 1(Picture) Distribution Panel 100 AMP service 7.1 Item 2(Picture) Electrical wiring in panel. 7.2 Branch Circuit Conductors, Overcurrent Devices and Compatability of their Amperage and Voltage 1234 Main St Page 28 of 38

Recessed lighting in kitchen and front room turn on and off intermittently. It is possible that the lights are turning off to reaching a particular temperature. The lights were clicking as if their emergency shut off was kicking on. Have a qualified electrician repair or replace. 7.2 Item 1(Picture) Lights that turn on and off intermittently. 7.3 Connected Devices and Fixtures (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) 7.4 Polarity and Grounding of Receptacles within 6 feet of interior plumbing fixtures, all receptacles in garage, carport and exterior walls of inspected structure 7.5 Operation of GFCI (Ground Fault Circuit Interrupters) GFCI outlets are wired properly 7.5 Item 1(Picture) GFCI wired properly. 7.6 Location of Main and Distribution Panels 1234 Main St Page 29 of 38

The main panel box is located in the basement. 7.6 Item 1(Picture) Main distribution panel 7.7 Smoke Detectors Comments: Not Present There were no smoke detectors present at the time of the inspection. Without a working smoke detector in your home you have no first alert to a possible fire. A qualified person should repair or replace as needed. 7.8 Carbon Monoxide Detectors Comments: Not Present There is no carbon monoxide detector found in home. It is recommended that one be installed according to the manufacturer's instructions. The electrical system of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Outlets were not removed and the inspection was only visual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. 8. Heating / Central Air Conditioning The home inspector shall observe permanently installed heating and cooling systems including: Heating equipment; Cooling Equipment that is central to home; Normal operating controls; Automatic safety controls; Chimneys, flues, and vents, where readily visible; Solid fuel heating devices; Heat distribution systems including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units, convectors; and the presence of an installed heat source in each room. The home inspector shall describe: Energy source; and Heating equipment and distribution type. The home inspector shall operate the systems using normal operating controls. The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate heating systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections; Humidifiers; Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms. Styles & Materials Heat Type: Forced Air Heat System Brand: UNKNOWN Energy Source: Gas Ductwork: Partially insulated Number of Heat Systems (excluding wood): One Filter Type: Disposable 1234 Main St Page 30 of 38

Serial # : Gibson 905006K+KGG141207381 Filter Size: Adequate Number of Woodstoves: None Central Air Manufacturer: GIBSON 8.0 Heating Equipment Types of Fireplaces: None Cooling Equipment Type: Air conditioner unit Number of AC Only Units: None Items Operable Fireplaces: None Cooling Equipment Energy Source: Electricity 8.0 Item 1(Picture) Gibson Unit 8.0 Item 2(Picture) Furnace December 9th 2014 production - 10 year warranty according to manufacturer website. 80+ High Efficiency Model K 2-4 Tons of cooling airflow 1234 Main St Page 31 of 38

According to our Climate Zone (Chicago, IL), a 3.5 ton unit should cool anywhere from 2001-2250 square feet 8.1 Normal Operating Controls Thermostat located to the left of the bathroom entrance. 8.1 Item 1(Picture) Thermostat 8.2 Automatic Safety Controls Emergency shut off for air conditioning compressor is pull type. 8.2 Item 1(Picture) Emergency disconnect at exterior unit. 8.3 Distribution Systems (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors), Repair or Replace 1234 Main St Page 32 of 38

Upon entering the home I lowered the thermostat to 75 degrees, the home was at 85 degrees when I entered. After two hours there was still a 10-15 degree difference between the first and second floors. Have a qualified HVAC contractor examine air flow and recommend a solution. The ductwork appears to need cleaning or replacing. 8.3 Item 1(Picture) Dirty vents. 8.4 Presence of Installed Heat Source in Each Room 8.5 Chimneys, Flues and Vents (for fireplaces, gas water heaters or heat systems) 8.6 Solid Fuel Heating Devices (Fireplaces, Woodstove) Comments: Not Present 8.7 Gas/LP Firelogs and Fireplaces Comments: Not Present 8.8 Cooling and Air Handler Equipment 8.9 Normal Operating Controls 8.10 Presence of Installed Cooling Source in Each Room The heating and cooling system of this home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed heat contractor would discover. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. 9. Insulation and Ventilation The home inspector shall observe: Insulation and vapor retarders in unfinished spaces; Ventilation of attics and foundation areas; Kitchen, bathroom, and laundry venting systems; and the operation of any readily accessible attic ventilation fan, and, when temperature permits, the operation of any readily accessible thermostatic control. The home inspector shall describe: Insulation in unfinished spaces; and Absence of insulation in unfinished space at conditioned surfaces. The home inspector shall: Move insulation where readily visible evidence indicates the need to do so; and Move insulation where chimneys penetrate roofs, where plumbing drain/waste pipes penetrate floors, adjacent to earth filled stoops or porches, and at exterior doors. The home inspector is not required to report on: Concealed insulation and vapor retarders; or Venting equipment that is integral with household appliances. Styles & Materials Attic Insulation: Unknown Dryer Power Source: 220 Electric Ventilation: Gable vents Dryer Vent: None Exhaust Fans: Fan with light Floor System Insulation: NONE 1234 Main St Page 33 of 38

Items 9.0 Insulation in Attic Comments: Not Inspected 9.1 Insulation Under Floor System Comments: Not Inspected 9.2 Vapor Retarders (in Crawlspace or basement) Comments: Not Present 9.2 Item 1(Picture) Cold room lacks insulation. 9.2 Item 2(Picture) Other side of cold room door 9.2 Item 3(Picture) Mechanical room no insulation. Missing insulation between the studs at the front of the house in the basement. In order to keep the cold from entering the basement you must insulate from the exterior walls. Have a qualified contractor install insulation. Mechanical room also lacks insulation between the studs, this would help regulate the temperature in the basement considering there is an exterior wall in this room. 1234 Main St Page 34 of 38

9.3 Ventilation of Attic and Foundation Areas 9.4 Venting Systems (Kitchens, Baths and Laundry) 9.4 Item 1(Picture) Dryer vent missing Dryer vent is missing connection to the exterior. A straight pipe without ridges is recommended to prevent lint from being trapped in the pipe and causing a possible fire. Replace before using the dryer. 9.5 Ventilation Fans and Thermostatic Controls in Attic Comments: Not Present The insulation and ventilation of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Venting of exhaust fans or clothes dryer cannot be fully inspected and bends or obstructions can occur without being accessible or visible (behind wall and ceiling coverings). Only insulation that is visible was inspected. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. 10. Built-In Kitchen Appliances The home inspector shall observe and operate the basic functions of the following kitchen appliances: Permanently installed dishwasher, through its normal cycle; Range, cook top, and permanently installed oven; Trash compactor; Garbage disposal; Ventilation equipment or range hood; and Permanently installed microwave oven. The home inspector is not required to observe: Clocks, timers, self-cleaning oven function, or thermostats for calibration or automatic operation; Non built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable. Styles & Materials Dishwasher Brand: FRIGIDAIRE Range/Oven: FRIGIDAIRE Refrigerator: FRIGIDAIRE Disposer Brand: NONE Built in Microwave: FRIGIDAIRE Items Exhaust/Range hood: NONE Trash Compactors: NONE 1234 Main St Page 35 of 38

10.0 Dishwasher Comments: Inspected The dishwasher is loose and needs securing to underside of countertop (using a proper length screw). I recommend repair as necessary. Also there is no water connection to the back of the refrigerator. With this connection missing the ice maker will not work and neither will the water dispenser. Have a qualified plumber repair. 10.0 Item 1(Picture) Dishwasher not attached. 10.1 Ranges/Ovens/Cooktops (1) There is no anti-tip bracket attached to the stove. (2) There is no anti-tip bracket attached to the stove. A stove can be tipped out accidentally in several ways. Simply pulling out a turkey or other heavy object from the oven can put a lot of weight on or above an open oven door. This can allow the stove to tip out towards the kitchen possibly injuring adults, children, or pets near the stove. Anything cooking on top of the stove will also fall possibly burning or scalding someone nearby. A child or pet can also put weight on an open oven door; this can also easily tip out the stove presenting the same hazard. 10.2 Range Hood (s) Comments: Not Present 10.3 Trash Compactor Comments: Not Present 10.4 Food Waste Disposer Comments: Not Present 10.5 Microwave Cooking Equipment The built-in appliances of the home were inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. 1234 Main St Page 36 of 38

INVOICE Above Grade Home Inspectors 124 W Polk St Chicago, IL 60605 773.610.9883 Inspected By: Stephen Santos Inspection Date: 9/28/2014 Report ID: Customer Info: Dr. Lucas 1234 Main St Chicago IL 60606 Inspection Property: 1234 Main St Chicago IL 60606 Customer's Real Estate Professional: Your name here! Inspection Fee: Service Price Amount Sub-Total Single Family 0.00 1 0.00 Payment Method: Cash Payment Status: Paid Note: Tax $0.00 Total Price $0.00 1234 Main St Page 37 of 38

Above Grade Home Inspectors Stephen Santos 124 W Polk St Chicago, IL 60605 773.610.9883 1234 Main St Page 38 of 38