Section SoundPly RF M25 Acoustic Wall Panels

Similar documents
Section SoundPly LR M25 Acoustic Ceiling Panels

Section Wood Veneer Ceiling Tiles Micro Perforated

Section Wood Grille Ceiling Panels

Section Wood Veneer Ceiling Planks Linear

Geometrik Manufacturing Inc.

Geometrik Manufacturing Inc.

Guide Specifications Section Wood Ceiling Coffers

DiSorb Diffuser Product Specifications Section Sound Diffuser-Absorber for Ceilings and Walls (DiSorb Diffuser-Absorber)

ACOUSTICAL WALL TREATMENT SECTION 09840

WoodTrends Acoustical Wood Ceiling System BASIC Specification

SECTION SOUND-ABSORPTIVE PANELS

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

Ceiling Tiles C200B - Specification

SECTION (09800) - Suspended Acoustic Baffles. This Section is based on TECHLITE Accent Linear Ceiling Baffles.

SECTION SOUND-ABSORPTIVE PANELS

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

HIR 1 ACOUSTICAL, IMPACT RESISTANT, TACKABLE WALL PANEL SPECIFICATION

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

RULON ACOUSTICAL CEILING SYSTEM ALURATONE 100 ARCHITECTURAL SPECIFICATIONS

Note: Delete any section below not relevant to this project; add others as required.

THIS SECTION IS BASED ON ROCKFON S SPANAIR HOOKON METAL CEILING PLANKS.

SECTION STRUCTURAL INSULATED PANELS

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

SECTION COMPOSITE CORE ACOUSTICAL PANEL CEILINGS. Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3

THIS SECTION IS BASED ON ROCKFON S CURVGRID ONE-DIRECTIONAL CURVED METAL CEILING PANELS.

SECTION ACOUSTICAL CEILINGS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION MULTI-USE COMPOSITE ALUMINUM PANELS

THIS SECTION IS BASED ON ROCKFON S TRADITIONS METAL CEILING PANELS.

COMPOSITESIDING

Guideline Specifications GORDON MARQUIS LINEAR CEILING PANEL SYSTEMS

SECTION LINEAR WOOD CEILINGS

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

Submittal Transmittal

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

Phenolic Exterior Wall Cladding

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

Store No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS

SECTION LINEAR METAL CEILINGS

Construction Standards PAGE

THIS SECTION IS BASED ON ROCKFON S PLANOSTILE D LAY-IN METAL CEILING PANELS.

SECTION ACOUSTICAL PANEL CEILINGS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

LINEAR METAL CEILINGS Section

SECTION ACOUSTICAL PLASTER CEILINGS

Guide Specification for: FABRI TRAK PVC FREE Stretched Fabric Wall System Section [ ] or Section [ ]

SECTION GLASS FIBER REINFORCED GYPSUM FABRICATIONS

Proposed Specification Section FLUSH WOOD VENEER DOORS

SECTION ACOUSTICAL PLASTER CEILINGS

THIS SECTION IS BASED ON ROCKFON S PLANOSTILE SNAP-IN METAL CEILING PANELS.

WOODFIT ACOUSTICS PERFORATED CEILING SYSTEM P007 ARCHICTECTURAL SPECIFICATION

Showcase Your Space. Not Your Access Panel. Product Features. Shop online at or call

A. This section includes pre-finished Higuera Hardwoods bamboo flooring and accessories for floors and stairs.

TECHNICAL DATA. I. Description of Components. Product Styles. Wood Selection. Wood Finishes. V. Fire Retardancy. LEED & Green Building Standards

SECTION EXTERIOR METAL WALL PANELS SERIES PF

Product Guide Specification Pliteq GenieMat FF06, GenieMat FF10, GenieMat FF17, GenieMat FF25, GenieMat FF50, GenieMat FF75

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

SECTION RESILIENT ATHLETIC SURFACING. B. Related Sections: Section(s) related to this section include:

5. Division 9 Section "Site-Built Stretched Fabric Wall System" for site-built stretched fabric

SECTION FOLDING DOORS AMSTEL AS900CC DIVIDER SOUND

SECTION FLUSH WOOD DOORS

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore

SECTION INTERIOR METAL WALL PANELS SERIES Z-CLIP

SECTION ACOUSTICAL CEILINGS

RULON WOOD SQUARE SUSPENDED CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

Framed Decorative Panel Systems

SECTION AXIOM INDIRECT FIELD LIGHT COVE PERIMETER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

SECTION FLUSH WOOD VENEER DOORS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION ACOUSTICAL PLASTER CEILINGS

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION DETECTABLE GUIDE TACTILES

SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

SECTION ACOUSTICAL CEILINGS (CEMENTITIOUS WOOD FIBER CEILINGS)

Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3. Tel Fax Web

Product Guide Specification

SECTION / STC 52 METAL SOUND CONTROL DOORS

Acoustic Wood Ceiling & Wall Panel - Product Information and Data Sheets

Product Guide Specification

Series 3000 Pocket Doors

***************************************************************** ** NOTE TO SPECIFIER **

Student Services & Classroom Addition

SECTION DRYWALL GRID LINEAR LIGHTING INTEGRATION

FORMICA SOLID SURFACING BY FORMICA GROUP / FABRICATIONS 3-PART TECHNICAL SPECIFICATION SECTION ( )

April 25, ADDENDUM NO. 2 This Addendum and attachments consists of: 17-Pages. ITB Turnagain Elementary School Interior Upgrades

SECTION ACOUSTICAL WALL TREATMENT (CEMENTITIOUS WOOD FIBER WALL PANELS)

Product Guide Specification

ACOUSTICAL WALL TREATMENT 09840

SECTION Axiom Roller Shade Integration

SECTION SOLID SURFACE COUNTERTOPS. Display hidden notes to specifier. (Don't know how? Click Here)

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections.

Transcription:

Section 097714 Acoustic Wall Panels PART 1 GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY A. Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to the work of this Section. A. Section Includes: 1. Acoustic wall panels B. Related Sections C. Alternates 1.3 SUBMITTALS 1. Section 01350 Special Environmental Requirements 2. Section 060100 Lumber 3. Section 060200 Finish Carpentry 4. Section 064000 Architectural Woodwork 5. Section 092116 Gypsum Board Assemblies 6. Division 23 Mechanical Diffusers, vents and other mechanical items 7. Division 26 Electrical lights and other ceiling mounted electrical items 1. Prior Approval: Proposed product substitutions may be submitted to the Architect no later than ten (10) working days prior to the date established for receipt of bids. Substitutions will only be considered if submitted with manufacturer s complete product information, including acoustical data and an 18 x 18 sample. Acceptance of substituted product is contingent on the Architect s approval and that substituted products comply with all specified requirements of this section. Approved products will be set forth by Addenda to all bidders. A. Comply with Section 013300 Submittal Procedures B. Product Data: Manufacturer s technical data and installation instructions for each type of wall panel required. C. Certifications: Certified test reports showing compliance with performance requirements specified. Page 1 of 6

Section 097714 Acoustic Wall Panels D. Samples: Submit a minimum of three (3) samples of each panel type and finish type required. Include samples that show the range of variation expected in grain, texture and color. E. Shop drawings: Submit shop drawings showing overall layout with dimensions and details of penetrations and intersections with other materials or building components. F. LEED requirements: Where specified submit required documentation indicating compliance. G. Submit operation and maintenance data for installed products. Include precautions relating to harmful cleaning materials and methods that would affect the service life of the panels. 1.4 QUALITY ASSURANCE A. Single Source Responsibility: Provide acoustic wall panels from a single Manufacturer with at least 2 years of prior experience fabricating projects of similar size and complexity. B. Installer: Installation shall be done by qualified Carpenters experienced in the installation of architectural woodwork. Installers must receive training on handling, cutting, machining and field finishing the specified product prior to receiving materials on site. C. Fire Performance Characteristics: Class A as tested by an independent accredited testing facility. Tests: ASTM E84. Flame spread: 25 or less. Smoke developed: 450 or less as specified by State or local codes. D. Applicable LEED Credits: 1. EA 1 Optimized Energy Performance 2. MR 4.1, 4.2 Recycled Content 3. MR 6 Rapidly Renewable Materials 4. EQ 4.1, 4.4 Low-Emitting Materials 5. MR 5.1 Use of Regional Materials (dependent on project location) 6. MR 7 Use of FSC material 7. EQ 7 & 7.1 Thermal Comfort 8. EQ 9 Enhanced acoustical performance E. Coordination of Work: Installing contractor shall organize and conduct a pre-installation survey of temperature, humidity, and construction elements attaching, penetrating, or concealed behind the acoustic wall panels. Page 2 of 6

Section 097714 Acoustic Wall Panels F. Acoustic wall panels to be manufactured from no less than 67 percent post-industrial recycled materials by weight. 1.5 REFERENCES A. Test Methods: 1. ASTM C 423 Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method performed by an independent testing agency. 2. ASTM E 84 Standard Test Method for Surface Burning Characteristics of Building Materials 3. ASTM E 336 Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings 4. ASTM D 1037 Linear Expansion with Change in Moisture Content 1.6 DELIVERY, STORAGE AND HANDLING A. Deliver panels to the project in original, unopened packages. Inspect containers for visible damage and report any questionable condition to the shipper and manufacturer immediately. B. Store products in a fully enclosed, clean, dry space out of direct sunlight and protected from damage with temperature controlled between 50 and 86 degrees F. C. Handle products carefully to avoid damaging panel surfaces or chipping edges. Report any damage immediately. Installation of damaged panels is not covered by the manufacturer s warranty. 1.7 PROJECT CONDITIONS A. Do not install acoustic wall panels until space is enclosed and weather-proofed, wet work is completely dry, and ambient temperature and humidity conditions are maintained at the levels indicated for the project when occupied for its intended use. B. Permit panels to reach room temperature, 50 to 86 degrees F, and stabilized moisture content of 25% to 55% RH for at least 72 hours before installation per AWI standards. Building should be enclosed and HVAC systems functioning in continuous operation with relative humidity maintained between 25 and 55 percent. 1.8 WARRANTY A. Provide manufacturer s standard one year written product warranty per Section 01770 Closeout Procedures Manufacturer s warranty is limited to decorative or acoustical panel materials only. Page 3 of 6

Section 097714 Acoustic Wall Panels 1.9 MAINTENANCE A. Maintenance Instructions: Provide manufacturers standard maintenance and cleaning instructions for finishes provided. B. Extra Materials PART 2 PRODUCTS 2.1 MANUFACTURER 2.2 MATERIALS 1. Deliver no less than (3 percent, 5 percent, 1 carton) of each type, color and pattern of material. 2. Extra materials shall be from the same production run as the original materials. 3. Extra materials shall remain in the manufacturer s original unopened packaging and stored in a fully enclosed, clean, dry space out of direct sunlight and protected from damage with temperature controlled between 50 degrees F and 86 degrees F. A. Provide wall system utilizing SoundPly Acoustic Panels manufactured by Navy Island Inc., 275 Marie Avenue E, St. Paul, MN 55118, Ph. (651) 451-4454, email sales@navyisland.com. A. SOUNDPLY RF M25 Acoustic Wall Panels for interior installation 1 (25mm) thick acoustical or decorative panels as follows: An architectural face material (wood veneer, UV printed, painted, vinyl, decorative paper or other approved material) laminated to a rigid backer. Face and backer thickness not less than 1.5mm (0.060 ), to provide long-term color stability of face material, in addition to adequate impact resistance for the panel. The core of the panels shall be comprised of a Class A material and a balancing backer sheet. B. Acoustical Panels: Panels will be furnished with a perforated face consisting of 0.5mm (0.02 ) diameter holes in an offset pattern. The perforations must be clean, without rounded edges or grain pull out between perforations. A minimum of 99.5% of the perforations must be acoustically functional, providing unobstructed passage into the open cavities of the core. Perforations must maintain consistent diameter through the face and backer, with no tapering or roughness. A fiberglass-reinforced polymer sheet, designed to balance the face, will be applied to the back of the panels, and will vary based on the face sheet specified. C. Panels Edge Treatment: Panels will be edge banded with the matching materials and finish, or as specified by the architect, to match or contrast with the panel face. D. Panel Weight: Panels will not exceed 1.8 lbs/ft 2 (8.8 kg/m 2 ) for 1 (25mm) thick panels. Page 4 of 6

Section 097714 Acoustic Wall Panels E. Panel Sizes: Panels are custom sized based on field dimensions up to a maximum of 1525mm (60 ) by 3660mm (144 ). Panels longer than 3048 mm (120 ) are limited by veneer availability. F. Flame Resistance: Class 1(A) rating based on ASTM E-84 Standard Test Method for Surface Burning Characteristics in Building Materials. Some veneer species and other face materials may not achieve an overall Class 1(A) rating. Check with local building codes for requirements or exemptions. G. NRC Performance: Noise Reduction Coefficient for acoustical panels to be no less than 0.90 using Type F6 direct mount without additional acoustical insulation. H. STC Performance: Sound Transmission Class to be no less than 37 using ASTM Test Method E336. I. Panel Stability: Linear contraction or expansion to not exceed 0.4% maximum variation in width or height per ASTM D1037. J. Finish for Veneer faced panels: PART 3 EXECUTION 3.1 EXAMINATION 1. Species as selected by the architect. 2. Cut: (plain sliced, quartered/rift, rotary) 3. Grade: Trugrade (70, 80, 90) 4. Matching veneer leaves: (book, slip, random matching) 5. Matching between panels: (no sequencing, natural sequencing, specified sequencing, blueprint match, blueprint and endmatched) 6. Finishes, shall be applied in the shop: (clear, stained, painted, as selected by architect.) A. Inspect installation area and conditions under which work is to be performed for compliance with all manufacturers environmental requirements. All wet work in the installation area must be complete, cured and dry prior to installation. Do not proceed until all unsatisfactory conditions have been corrected. 3.2 INSTALLATION Page 5 of 6

Section 097714 Acoustic Wall Panels A. Installation must be done by qualified carpenters experienced in the installation of architectural woodwork. The firm must demonstrate successful experience installing materials of similar type and quality of those required for this project. The use of proper carpentry tools and techniques will be required for the installation. B. Comply with manufacturer s instruction and recommendations for installation of wall panels consistent with industry standards. C. Confirm all field dimensions are coordinated with shop drawings. D. Coordinate the exact size, location and sequencing of panels including penetrations by all building components. E. Lay out wall panels per approved shop drawings. Report any interferences or deviations before proceeding. 3.3 ADJUSTING AND CLEANING A. Clean soiled surfaces of wall panels per manufacturer s instructions. B. Remove and replace damaged or discolored materials not in compliance with manufacturer s tolerances. C. Adjust tiles after installation so that surfaces are aligned with gaps or reveals between units straight and consistent in width. END OF SECTION Page 6 of 6