COMMENTARY TO ANSI/TPI/WTCA METAL PLATE CONNECTED WOOD TRUSSES Revised 2002

Similar documents
RESPONSIBILITIES IN THE DESIGN PROCESS INVOLVING METAL PLATE CONNECTED WOOD TRUSSES

Position Statement on Sealed Truss Placement Diagrams for Projects in the State of California

A. Provide all wood trusses as indicated on the drawings or as required to do a complete job.

Section Downloads. Design Responsibilities Outline. The Need for Standard Design Responsibilities. Non-Conforming Specifications

SECTION PLATE CONNECTED WOOD TRUSSES

Changes in the 2007 Supplement to the 2006 International Building Code That Affect Component Manufacturers

Chapter 10: Roof Truss Legalese

Chapter 10: Roof Truss Legalese

C. Delegated-Design Submittal: For metal-plate-connected wood trusses indicated to comply with

Design Responsibilities for Commercial Construction Projects in the State of Idaho

Long Span Truss Installation

What Should Constitute a Truss Submittal Package?

What Should Constitute a Truss Submittal Package?

Introduction: Issue: Analysis/Conclusion:

Design Responsibilities for Commercial Construction Projects in the State of Michigan

WOOD I-JOIST AWARENESS GUIDE

Specifying Pre-Engineered CFS Floor and Roof Trusses 551f-98

International Building Code/International Residential Code Inspection & Quality Assurance Requirements for Metal Plate Connected Wood Trusses

TRUSS INDUSTRY STANDARD OF CARE ISSUES

SECTION METAL PLATE CONNECTED WOOD TRUSSES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

1 Exam Prep BCSI Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses Questions and Answers

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

SECTION COLD-FORMED METAL FRAMING

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

FIGURE R502.2 FLOOR CONSTRUCTION

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

SECTION COLD-FORMED METAL TRUSSES

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

Truss Repair and Modifications. Overview Revised 4/7/2017

Special Inspections for Trusses

Your full service light gauge steel manufacturer

TECHNICAL NOTE On Cold-Formed Steel Construction

INSTALLATION. General. Important Note. Design. Transport

UNIFIED FACILITIES GUIDE SPECIFICATIONS

PART 4: GENERAL CONDITIONS

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

SECTION COLD-FORMED METAL FRAMING

SECTION STEEL JOIST FRAMING

SECTION COLD-FORMED METAL FRAMING

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

Wood Truss Restraint and Bracing Guide

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

A. The work under this section consists of furnishing and installing gauge steel framing and bracing as indicated on the drawings and as specified.

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014

Individual Truss Marking Is it a Building Code Requirement?

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION SHOP-FABRICATED WOOD TRUSSES

Temporary Construction Loads Over I-Joist Roofs And Floors

A. Section Metal Decking. (05300 in MF95) B. Section Cold Formed Metal Framing. (05400 in MF95)

The only limit to the use of truss construction is one s imagination.

Common Errors in Truss Design

Structural. Professional Engineers Ontario

SPECIAL INSPECTION AND TESTING AGREEMENT

Modular Wood Framing Goes Vertical

PART 1 GENERAL SHOP FABRICATED WOOD TRUSSES

The designer shall also submit additional information required by the University as described and underlined below.

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

6300 Enterprise Ln Madison, WI

ROOME & GUARRACINO, LLC Consulting Structural Engineers 48 Grove Street Somerville, MA Tel: Fax:

STORAGE RACKS PLAN REVIEW LIST (2011 LABC)

Truss Technology in Building:

Position Statement on Sealed Truss Placement Diagrams for the State of Texas. Overview Revised 3/23/2017

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

Patio Covers Building Guides for Homeowners

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

STEEL FRAMING INDUSTRY ASSOCIATION OBSERVATION REPORT PROTOCOL STRUCTURAL FRAMING GUIDELINES FOR THE INSPECTOR

Inspection and Quality Assurance Requirements for Metal Plate Connected Wood Trusses. Educational Overview

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( )

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

S IBC: Proposed Change as Submitted

HYBRID CONCRETE MASONRY CONSTRUCTION DETAILS. TEK 3-3B Construction (2009) Related TEK: 14-9A

Significant Changes to AWC s Special Design Provisions for Wind and Seismic

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses. DD No

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

STRUCTURAL STEEL FRAMING

Facts on the Fire Performance of Wood Trusses

Project Seismic Vulnerability Assessment For SFCC District Building 33 Gough Street San Francisco, California 94103

Plan Check No. Checked by: An Appointment Is Required for Verification

DISTRESS PHENOMENA OFTEN MISTAKENLY ATTRIBUTED TO FOUNDATION MOVEMENT

Position Statement on Sealed Truss Placement Diagrams for Projects in the State of Florida

Genesis. Light-Steel Structural Projects. Build with the Global Green Building Experts

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Project Address: Name of Person Completing Form:

DISTRESS PHENOMENA OFTEN MISTAKEN FOR FOUNDATION MOVEMENT

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

Building Standards Review Process Changes for Designs beyond the Scope of Part 9 (Rev: Feb. 26, 2018)

STRUCTURAL BUILDING COMPONENTS MAGAZINE January/February 2005

INTRODUCTION. GANG-NAIL Truss System

Position Statement on Sealed Truss Placement Diagrams for Projects in the State of Florida

Transcription:

Truss Technology IN BUILDING COMMENTARY TO ANSI/TPI/WTCA 4-2002 METAL PLATE CONNECTED WOOD TRUSSES Revised 2002 I. INTRODUCTION & GENERAL COMMENTARY National Standard and Recommended Guidelines on Responsibilities for Construction Using Metal Plate Connected Wood Trusses (ANSI/TPI/WTCA 4-2002) has been developed in accordance with the consensus protocol of the American National Standards Institute (ANSI), through the Truss Plate Institute (TPI). It is based on WTCA 1-1995, Standard Responsibilities in the Design Process Involving Metal Plate Connected Wood Trusses, which was originally developed through an open consensus-based committee approach spearheaded by the Engineering Review Committee of the Wood Truss Council of America (WTCA), a not-for-profit corporation. ANSI/TPI/WTCA 4-2002 is intended as a comprehensive and thorough approach to the clarification of design responsibilities when wood trusses are incorporated into a building or structure. Although some confusion may exist in the construction industry concerning the delegation of such design responsibilities, from the wood truss industry s perspective the design responsibilities of truss manufacturers and truss designers are quite clear. The person or organization involved in the truss design, the Truss Designer, is responsible for the individual truss component design. The company manufacturing the trusses, the Truss Manufacturer, in turn accepts responsibility for the performance of the trusses it manufactures. Through this process, all of which is carefully defined in ANSI/TPI/WTCA- 4, the Truss Manufacturer supplies an engineered product that will perform well if used in accordance with accepted engineering, and correct building practices. ANSI/TPI/WTCA 4-2002 is not intended to restrict the work that a component manufacturer undertakes, but rather seeks to define specific scope of work considerations as one begins the contracting process for a given project. The intent of this document is to serve as a guide for possible language that can be II. included in contracts. Additionally, it is the intent of this document to point out when one party is asking another party to a contract to expand their typical scope of work. If any party expands their typical scope of work, strong consideration needs to be given to getting properly compensated for this expanded role in the project, as well as the expanded business risk. SPECIFIC SECTION COMMENTARY 2.4 The term Building Designer, while it may include an Architect (see definition of Architect in 2.1) or an Engineer (see definition of Engineer in 2.8), is not restricted to Architects or Engineers, as many state and local laws do not require the involvement of a registered or licensed professional in the design of certain types of buildings or structures. In these instances, responsibility for compliance of the building or structure with all legal requirements rests with the Owner (see definition of Owner in 2.11). 2.5 The structural system of a building is the completed combination of structural elements that support the building s self weight, applicable occupancy live loads, and environmental loads (e.g., snow, wind, seismic, etc.). These elements may include beams, columns, structural members, and prefabricated structural components, including metal plate connected wood trusses (see definition of Truss in 2.14). These elements, when combined, form a building s structural system. In designing the building and its structural system to comply with all legal requirements and to determine what structural elements may be used, drawings and specifications are prepared, which are referred to as the Building Structural System Design Documents. The Building Structural System Design Documents must provide sufficient information to enable the construction trades responsible for supplying the 020814 RespDCom [WTCA-4]

structural elements used to construct the building [such as the Truss Manufacturer (see definition in 2.18) if trusses are to be used] to design these structural elements. 2.16 The trusses designed for use in a building s structural system are individually depicted in the Truss Design Drawings. Truss Design Drawings are not typical construction shop drawings, as they do not set forth fabrication, assembly or installation details. Additional information on Truss Design Drawings can be found in WTCA s brochure Truss Technology in Building (TTB) How To Read A Truss Design Drawing. See www.woodtruss.com to review this brochure. 2.19 The Truss Placement Plan, if required, is prepared based on the Truss Manufacturer s interpretation of the Building Structural System Design Documents and is meant to assist the Contractor (see definition of Contractor in 2.7) in correctly locating individual trusses in the structure. The Truss Placement Plan will reflect a truss identifying mark and perhaps other products supplied by the Truss Manufacturer so these products can be more easily identified by the Contractor during field erection. The Truss Placement Plan is not an engineered drawing and is not intended to replace the Building Structural System Design Documents; it is only a guide for installation and requires no engineering input. Nevertheless, if the Truss Placement Plan is required, it must be reviewed and approved by the Owner, either directly or by Contract with the Contractor and the Building Designer. Additional information on Truss Placement Plans can be found in WTCA s brochure TTB How To Read A Truss Placement Plan. See www.woodtruss.com to review this brochure. 3.1-3.3 The model building codes used by all local jurisdictions stipulate that the Owner is responsible for obtaining a permit to build the structure and is responsible for that structure s compliance with the building code requirements. The Owner may choose to retain others, such as the Contractor and Building Designer, and through Contract delegates the responsibility of design, construction and code compliance to these individuals. At times, the Contractor may also function as the Building Designer. The allocation of design responsibilities to the Contractor in such instances is consistent with the model building codes, which state that building permit applicants (e.g., the Contractor) are responsible for ensuring the structure remains in full compliance with the building code. At times the Owner may also function as the Contractor and quite possibly the Building Designer. 4.1 The listed adverse influences may have a long term effect on the performance of Trusses and Structural Elements, such as moisture creates conditions conducive to softwood decay; high temperatures can cause decreased capacity of wood members; corrosive chemicals and gasses may affect zinc coated steel connector plates. For instance, an ocean exposure can cause connector plate corrosion. The Building Structural System Design Documents must provide such conditions so that corrective measures may be incorporated into the Truss Submittals and Structural Element Submittals for the building. 4.2.1 & 4.2.2 The Building Structural System Design Documents must provide for a spatial definition of all trusses to be located in the structure, although it is not necessary for the Building Structural System Design Documents to provide the size of the truss chords and webs, web patterns, or the truss design. It is important that the full intent of the Building Structural System Design Documents is understood and can be adequately transferred into the appropriate Truss Designs and Truss Design Drawings. Sometimes roof plans are developed, showing slopes, hips, overhangs, ridge and valley lines, etc. For anyone to produce a proper Truss Placement Plan it is necessary for the Building Structural System Design Documents to show span and spacing of trusses, locations of supporting columns, beams, girders, and/or load bearing walls. It is also necessary to show any raised or dropped ceiling areas and/or internal accessible attic spaces. 4.2.3 Identification of intended truss bearing locations within the Building Structural System Design Documents is critical to enable each truss to be designed and built to the correct dimensions and for the intended support conditions. Specification of intended bearing conditions also enables the Truss Manufacturer to ensure that each truss is provided with adequate bearing. However, it is not the Truss Manufacturer s responsibility to ensure that the structural elements upon which the trusses will rest (e.g., wall, beam, column, etc.) have sufficient capacity to support each truss, and provide sufficient bearing length. 4.2.4 To ensure that the structural capacity of the trusses designed by the Truss Designer is sufficient for the structure for which they are designed, all applicable design loads must be expressly stated in the Building

Structural System Design Documents. Simply referencing a section of a building code within the Building Structural System Design Documents does not provide the Truss Manufacturer or others with the necessary or required information. Furthermore, special loading conditions for drifting snow or localized wind loading effects should be clearly indicated in the Building Structural System Design Documents by text and/or diagram. Once the loadings are known, the Truss Manufacturer s Truss Designer will undertake the structural design of every truss component needed to carry all the imposed loads and combinations of loads as specified by the code. These individual component designs can then be integrated into the final roof or floor system by the Building Designer. 4.2.5 Contemporaneous preparation of the Building Structural System Design Documents with that of the Truss Design Drawings would allow for easier design of support and bearing conditions, temporary and permanent lateral and diagonal bracing, and all the anchorage needed to resist uplift, gravity and lateral forces on the structure. However, as it is often impractical, or even impossible, for the Truss Designer to provide input at the time the Building Structural System Design Documents are prepared, many engineering assumptions will need to be made in the design of the structure. Accordingly, the Truss Design Drawings, when produced, may not exactly match with the assumptions used. For example, it is very unlikely that the calculated uplift loads will match the uplift loads developed by the Truss Designer. They should not be expected to be identical. For this reason, it is essential that the Truss Design Drawings be reviewed and approved by the Building Designer as delegated to by the Owner, or the Owner. It is the responsibility of the Owner or the Building Designer, as delegated, to specify appropriate uplift loads and connection requirements for use by the Contractor for all anchorage and connection requirements of the Trusses. 4.2.6 Vertical deflection criteria for structural elements used in various types of construction applications are provided by all three major model building codes. These criteria are intended to minimize damage of supported construction materials (e.g., plaster, gypsum wallboard, etc.) and establish a minimum level of performance. Whether this minimum level of deflection performance is suitable to the Owner and those occupying the structure, however, is a highly subjective matter. The finished structure s floor and/ or wall finishes (e.g., ceramic tile or marble) may require more stringent deflection limits to prevent cracking of grout, tile, taped joints and wall board. Given the subjective nature of deflection and vibration performance and that the occupants can be very sensitive to floor vibration (bounce), more restrictive limits on deflection may need to be specified. It is important to note, however, that deflection limits alone may not resolve all vibration issues. Since trusses can be designed to meet virtually any deflection criteria, it is imperative that the required deflection criteria are specified in the Building Structural System Design Documents. Horizontal deflection limitations are also critical for truss configurations utilizing dual pitched bottom chords (e.g., scissors trusses), as gravity loads applied to these trusses produce both vertical and horizontal deflection. The supporting structure and the truss-to-wall connection must be designed appropriately to account for any horizontal displacement. Without these limits, trusses cannot be designed effectively to minimize cracking and bowing that can take place at bearing wall locations. It is also important to have the proper shear walls to resist horizontal deformations. 4.2.7 The engineering term that best describes the intent of this section is tracking the flow of loads or load paths. All truss loads must be accounted for on the Building Structural System Design Documents and properly transferred through the structural elements to the building s foundation. The Truss Designer has the capability to add these forces to the truss design and adjust individual truss members and their connectors accordingly, but the connections between the transferred load and the truss system must be shown on the Building Structural System Design Documents. 4.2.9 Truss-to-truss connections, truss-to-truss girder connections, ply-to-ply connectors for multi-ply truss girders, are all designed and specified by the Truss Designer. All truss to non-truss connectors (e.g., truss to bearing walls, truss to steel beams, truss to masonry) are not the responsibility of the Truss Designer and must be shown on the Building Structural System Design Documents. 4.3 As trusses are simply structural elements, the Truss Manufacturer and Truss Designer assume responsibility only for the internal design integrity of the individual trusses produced, and not the floor or roof systems (which are part of a building s structural system) in which the trusses are to be placed. As

the design and performance of floor or roof systems is not the responsibility of the Truss Manufacturer and Designer, it is essential that the individual Truss Design Drawings be reviewed and approved by the Building Designer as delegated to by the Owner or the Owner. The goal is to ensure each individual component works appropriately within the systems and the structure, and also serves as a double check to ensure that the Truss Designer and Building Designer have not missed any details. In particular, (a) determining that the Truss Design Drawings and Truss Placement Plan(s) (if required) have been prepared in accordance with the requirements of the Construction Design Documents, (b) verifying the design criteria utilized in the Truss Design Drawings, (c) evaluating the effects of the truss designs on the floor or roof systems, and (d) determining that the truss configurations set forth in the Truss Design Drawings are consistent with the Construction Design Documents. 5.1 The Contractor or individual or organization responsible for the installation of the Trusses and Structural Elements is entitled to rely on the accuracy of the design calculations contained in the Truss Design Drawings and the Truss Placement Plan(s), if required, which set forth the Truss Manufacturer s interpretation of the requirements of the trusses as set forth in the Building Structural System Design Documents. It is recommended that the Contractor carefully review and approve the Truss Design Drawings and the Truss Placement Plan to (a) determine if they comply with the intent of the Building Structural System Design Documents, (b) check for any errors that may potentially lead to costly remedial work, and (c) plan for a systematic communication and coordination between the building trades with respect to truss placement and installation requirements, thereby greatly reducing the potential of having to cut and modify the trusses due to interference with plumbing, electrical, and/or HVAC runs and equipment. It is custom and practice in the construction industry for the prime or general Contractor to coordinate the approval and return of all Truss Submittals (i.e., Truss Design Drawings and Truss Placement Plans) and Structural Element Submittals (e.g., I-joists, glulam beams, laminated veneer lumber, etc.) for the project. 5.2 & 5.5 Once the Truss Manufacturer delivers the trusses to the job site, he/she has turned over title of the trusses to whomever has purchased them. All work undertaken thereafter is the responsibility of the owner of the trusses or the person or organization that the owner delegates this responsibility to. Trusses are planar structural components whose structural performance depends upon being installed vertically, in-plane, at specific spacing, and being properly braced. Trusses can be easily damaged by improper field storage or handling during erection. Failure to adequately install and brace the trusses can also result in damage to the trusses, but more significantly, may also cause worker injury. The majority of wood truss related accidents occur during truss installation. The principal causes of such accidents include: (a) inadequate and/or improperly located temporary bracing, (b) improperly installed and/or inadequate connection of the bracing to the truss, (c) improper and/or inadequate connection of the truss and/or bracing to the supporting structure, (d) overloading roof or floor trusses before the trusses have been permanently braced (e.g., stack of plywood), (e) overloading roof or floor trusses after installation is completed (e.g., stack of materials such as plywood, drywall, etc.), (f) improper or unauthorized field alterations, (g) installation of broken, damaged, or improperly repaired trusses, (h) improper truss alignment before bracing, (i) improperly designed or installed support structures (e.g., walls, beams, etc.), and (j) failure to provide during the installation process the required permanent compression member bracing at the locations shown on the Truss Design Drawings. Educational materials providing recommendations on the handling, installation, and temporary bracing of trusses are available from the wood truss industry in the form of several documents including: TTB Truss Checklist For Handling & Installing Trusses, WTCA-B1 (Jobsite Warning Poster), WTCA-B2 (TTB Always Diagonally Brace for Safety), a WTCA video entitled Handling, Installing and Bracing of Metal Plate Connected Wood Trusses, TTB Construction Loading, TTB Commentary For Permanent Bracing of Metal Plate Connected Wood Trusses, TTB Web Member Permanent Bracing, TTB Web Reinforcement, TPI s Recommended Design Specifications For Temporary Bracing of Metal

Plate Connected Wood Trusses (DSB-89) and Commentary and Recommendations for Handling, Installing & Bracing Metal Plate Connected Wood Trusses (HIB-91, booklet and summary sheet). WTCA also has a Temporary Bracing Model showing the stiffening effect of proper temporary bracing on a structure. These materials are available through local Truss Manufacturers or WTCA. The recommendations provided in these documents are offered as guidelines and are not to be interpreted as superior to the Building Designer s specifications or considered to be the only method for handling, installing, and bracing of trusses. 5.3 & 5.4 As trusses are engineered structural components, their structural integrity can be substantially altered by damaging, cutting, or modifying any of their members. Truss members may break if improperly handled during the unloading, storage, installation and erection phases of the project. If the trusses are cut or modified by the construction trades to avoid interference with other building components, the Contractor is responsible for securing the documentation required for repairing the Truss. The Truss Manufacturer should be informed immediately of any damaged, cut, or field modified trusses and may be able to assist in providing the required documentation. A guideline brochure, TTB Truss Repair, describes how truss damage, alterations and installation errors must be repaired according to an approved truss repair detail and the information that the field crew must provide in order to secure an accurate repair detail from the truss manufacturer. See www.woodtruss.com to review this brochure. 5.6 Properly designed permanent bracing is necessary to maintain the integrity of the structure, especially when the structure is subjected to lateral loads imposed by wind or seismic forces. The design of all permanent bracing for the structure, including the trusses, is the responsibility of the Building Designer and not the responsibility of the Truss Manufacturer and Truss Designer, as the loads resisted by permanent bracing must be transferred to, and supported by the structure. Included as part of the permanent bracing for trusses is the continuous lateral bracing required to enhance the buckling capacity of certain truss compression members. The need for permanent lateral bracing or support for certain individual truss members (chords or webs) is determined by the Truss Designer, and is specified in detail on the individual Truss Design Drawings. This bracing is intended to prevent bowing or buckling of individual truss members under design loads and enables the truss component to perform as designed. However, the Truss Designer must rely upon others to specify how the lateral bracing is to be anchored or restrained to prevent multiple identical members from buckling out of the plane of the trusses, at the same time. Permanent diagonal bracing at intervals in the plane of the braced member is one way to accomplish this restraint. The Truss Designer will set forth in the Truss Design Drawings, the maximum axial compression forces in the truss members, as well as the location(s) where this bracing is required. The Building Designer will then design the size, connection and anchorage of the permanent bracing to the truss member, as well as to the supporting structure. Additional information on the design and installation of permanent bracing, written with the Building Designer in mind, is reviewed in detail in the following WTCA publications: TTB Commentary for Permanent Bracing of Metal Plate Connected Wood Trusses and TTB Permanent Bracing. See www.woodtruss.com to review these brochures. 6.1 6.4 The Truss Manufacturer typically receives the Building Structural System Design Documents directly from the Contractor. From the information contained in the Building Structural System Design Documents, the Truss Manufacturer finds and documents the truss design criteria and, if required, creates a Truss Placement Plan. The truss design criteria as documented by the Truss Manufacturer are provided to the Truss Designer, who then uses this information to prepare the Truss Design Drawings. Some Truss Manufacturers directly employ Truss Designers; for others, the Truss Designers are retained on a contractual basis. The Building Structural System Design Documents contain appropriate information to enable the Owner, and/or Building Designer or

Contractor to adequately review and verify that the Truss Design Drawings conform to the requirements and intent of the Building Structural System Design Documents. Sufficient information is also provided to enable the design of the size, connections, and anchorage of the permanent continuous lateral bracing (see 5.6). The Truss Design Drawings furthermore provide all the truss related information typically required by code officials for plan review and field inspection purposes. 6.5 Chapter 3 of ANSI/TPI 1-2002 is the quality standard for the manufacturing processes of metal plate connected wood trusses. 6.6 The Truss Placement Plan prepared by the Truss Manufacturer is not an engineering document and should never be considered as a replacement for a structural framing plan prepared by the Building Designer. The preparation of the Truss Placement Plan does not require the special education, training and experience that define the practice of engineering (as found in state engineering laws). Since the Truss Placement Plan prepared by the Truss Manufacturer is not an engineering document, it should not be sealed. When a sealed structural framing plan is required, it should be prepared by the Building Designer responsible for the overall building design to ensure the adequacy and safety of the entire structure. The Truss Placement Plan prepared by the Truss Manufacturer should ordinarily be reviewed and accepted for conformance with the overall building design by the Building Designer of record. Additional information on Truss Placement Plans can be found in the TTB brochure How To Read A Truss Placement Plan. See www.woodtruss.com to review this brochure. that have adequate capacity for the design conditions shown on the Truss Design Drawings, so long as the Truss is spaced as referenced on the drawing (usually 24" on center) and the Truss is properly manufactured, installed and braced. The physical size and shapes of the trusses and the design loadings should be shown on the Building Structural System Design Documents. The Truss Design Drawings then become a reflection of the intent of the Building Structural System Design Documents, but it is essential that the individual Truss Design Drawings be reviewed and approved by the Building Designer as delegated to by the Owner or by the Owner themselves, before the trusses are manufactured. In the absence of a professional Building Designer, or an understanding by the Owner of how loads are applied or how they flow through the structure to the foundation, the Truss Designer does not assume these responsibilities. Truss Designers also have no responsibility to evaluate the effect of the trusses on the structural system of the building. The Truss Design Drawings furthermore do not constitute a temporary or permanent bracing plan for the structure. 7.4 A guideline brochure, TTB Truss Repair, describes how truss damage, alterations and installation errors must be repaired according to an approved truss repair detail. This detail shall conform to sound wood design practices and can be undertaken by any design professional familiar with wood design. See www.woodtruss.com to review this brochure. Sample Truss Specification For Architects and Engineers (SECTION 06176 METAL PLATE CONNECTED WOOD TRUSSES) can be downloaded at www.woodtruss.com. This sample will aid in defining specific project scopes of work. 7.1-7.3 Truss Designers do not review, or check for errors or omissions potentially contained within, the Building Structural System Design Documents. The Truss Designer s scope of work is to simply design trusses WTCA does not intend these recommendations to be interpreted as superior to the project Architect's or Engineer's design specification for handling, installing and bracing wood trusses for a particular roof or floor. Wood Truss Council of America One WTCA Center 6300 Enterprise Lane Madison, WI 53719 608/274-4849 608/274-3329 (fax) www.woodtruss.com wtca@woodtruss.com Truss Technology IN BUILDING An informational series designed to address the issues and questions faced by professionals in the building construction process. Reproduction of this document, in any form, is prohibited without written permission from WTCA. This document should appear in more than one color.

Disclaimer This copyrighted document is a secure PDF, and while it can be opened, saved and emailed, it cannot be printed. To order copies or receive a complimentary hard copy, contact the WTCA at 608/274-4849.