LISTING INFORMATION OF Epilay - Superior, Ultra and Platinum Roofing Underlayments SPEC ID: Epilay Inc S. Main Street, E1 unit C

Similar documents
DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

UL Evaluation Report UL ER Issued: May 31, Revised: June 6, UL Category Code: ULEZ. CSI MasterFormat

Code Compliance Research Report CCRR-0164

Code Compliance Research Report CCRR 0241

Code Compliance Research Report CCRR-0225

Code Compliance Research Report CCRR 0277

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

Code Compliance Research Report CCRR-0225

Code Compliance Research Report CCRR 0270

Code Compliance Research Report CCRR 0232

Code Compliance Research Report CCRR-0257

ATI Evaluation Service A Division of Architectural Testing Certification Services Code Compliance Research Report

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES

PRODUCT EVALUATION Effective July 1, 2014 RC-28

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

Code Compliance Research Report CCRR-0266

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR-0238

Code Compliance Research Report CCRR-0153

MILLENNIUM METALS, INC TEST REPORT

Code Compliance Research Report CCRR-0238

Intertek Research Report IRR-1011

Advantage ICF System Product Information Bulletin

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOF PANELS REPORT HOLDER: ONDULINE NORTH AMERICA, INC. EVALUATION SUBJECT:

Code Compliance Research Report CCRR-0234

Engineering Services Program

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

PRODUCT CONTROL SECTION

Code Compliance Research Report CCRR-0114

Code Compliance Research Report CCRR-0208

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

Code Compliance Research Report CCRR-0163

Code Compliance Research Report CCRR-0185

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

Code Compliance Research Report CCRR-0262

EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659

FORTIFIED Home High Wind. Bronze New Roof Requirements

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

Code Compliance Research Report CCRR-0194

Code Compliance Research Report CCRR-0228

Code Compliance Research Report CCRR-0223

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

ROOF ASSEMBLIES CHAPTER 9

ARCHITECTS & SPECIFIERS : SHINGLES, TILES, & ROOF COVERINGS

Code Compliance Research Report CCRR-0163

UNDERLAYMENT PRODUCTS

Code Compliance Research Report CCRR-0106

Code Compliance Research Report CCRR-0171

Metal Roof Certification & Listing Program

Code Compliance Research Report CCRR-0187

Code Compliance Research Report CCRR-0231

Code Compliance Research Report CCRR-0118

Code Compliance Research Report CCRR-0137

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF TILES REPORT HOLDER: GERARD ROOFING TECHNOLOGIES EVALUATION SUBJECT:

Proud of its Heritage, Preparing for its Future

ICC-ES Report OR-4, AND MOISTURE DIVISION: SECTION: SECTION: Reissued 11/2017 This. Report Holder:

UNDERLAYMENT PRODUCTS

ESR-1061 Reissued May 1, 2011 This report is subject to renewal in two years.

SRP-AirOutshield ROOF Issued:

Code Compliance Research Report CCRR-0101

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

Engineering Services Program

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

Code Compliance Research Report CCRR-0186

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

LISTING INFORMATION OF CCI Manufacturing Inc. - HiBAR SPEC ID: CCI Manufacturing Inc Ave. Edmonton, AB T5V 1K5 Canada

LISTING INFORMATION OF ClarkDietrich Steel 'H' Stud and 'U' Track Fire-resistance-rated Area Separation Wall Assemblies SPEC ID: 26662

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

ZARA & ASSOCIATES, INC. Peter L. Zara 8435 Sunrise Lake Blvd -# Sunrise, Florida Phone

Re-Roof Permit Checklist

EVALUATION REPORT Boral Roofing /MonierLifetile 7575 Irvine Center Drive Suite 100 Irvine, CA

ESR-1826 Reissued May 1, 2009 This report is subject to re-examination in one year.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

Code Compliance Research Report CCRR-1043

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

Garage/Accessory Structures

ROOF ASSEMBLIES CHAPTER 9

technical bulletin ROOFING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

LISTING INFORMATION OF Metl-Span, LLC THERMALSAFE 8" Thick 3 Hour Fire Rated Panels SPEC ID: 29868

NEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)

BUILDING PRODUCTS LISTING PROGRAM

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015.

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

The Perfect Block OEM ICC Equivalent Product Compliance Report

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION

Transcription:

LISTING INFORMATION OF Epilay - Superior, Ultra and Platinum Roofing Underlayments SPEC ID: 30450 Epilay Inc. 21175 S. Main Street, E1 unit C Carson, CA 90745 This report is for the exclusive use of Intertek s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Epilay Inc. 30450 Rev: Sep 30 2013 5:36PM Uncontrolled Copy Page 1 of 5

RATINGS Epilay Superior, Ultra and Platinum are four-layered roofing underlayments consisting of a non-woven polypropylene scrim bonded to a woven polypropylene scrim and coated on both sides. The nominal weights of the Epilay Superior, Ultra and Platinum underlayments are 2.25, 2.90 and 3.70 lb/100 ft 2 (110, 140 and 180 gsm) respectively. Standard size rolls are 4 feet wide (1220 mm) by 250 feet long (76 m). Other roll sizes are available upon request. Epilay Superior, Ultra and Platinum roofing underlayments received Class A ratings based on the deck configuration shown below in accordance with ASTM E108: Slope: 5:12, Combustible Deck Nominal 15/32 thick AC grade exterior plywood deck. A single layer of Epilay Superior, Ultra or Platinum roofing underlayment mechanically fastened to the plywood sheathing every 8 OC on the perimeter and 12 OC in the field with ring shank roofing nails with 1 diameter plastic cap. Three tab asphalt shingles complying with ASTM D3018, brick, masonry, slate, clay or concrete roof tiles, exposed concrete deck, ferrous or copper shingles or sheets, and metal sheets and shingles coverings per manufacturer s instructions. Attribute Value Criteria ASTM E108 (2010a) Criteria ICC-ES AC207 (2012) CSI Code 07 30 05 Roofing Felt and Underlayment Intertek Services Certification Listed or Inspected LISTED Listing Section ROOFING MATERIALS Report Number G101234419 Epilay Inc. 30450 Rev: Sep 30 2013 5:36PM Uncontrolled Copy Page 2 of 5

DRAWING INDEX Epilay, IRR-1004 Epilay Inc. 30450 Rev: Sep 30 2013 5:36PM Uncontrolled Copy Page 3 of 5

Epilay, IRR-1004 Intertek Research Report IRR-1004 Issue Date: 10-01-2013 Renewal Date: 10-01-2014 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 30 05 Roofing Felt and Underlayment REPORT HOLDER: EPILAY INC. 21175 S. Main Street, E1 Unit C Carson, California 90745 http://www.epilay.com Report Subject: EPILAY SUPERIOR, ULTRA and PLATINUM ROOF UNDERLAYMENTS 1.0 SCOPE OF EVALUATION This research report addresses compliance with the following codes: 2012 and 2009 International Building Code (IBC) 2012 and 2009 International Residential Code (IRC) Epilay Superior, Ultra and Platinum roof underlayments have been evaluated for the following properties: Physical properties Fire Classification 2.0 USES Epilay Superior, Ultra and Platinum roof underlayments are used in the field of the roof as an alternative to the ASTM D226, Type I and Type II, roof underlayments specified in Chapter 15 of the IBC and Chapter 9 of the IRC. The underlayments may be used as components of classified assemblies when installed as described in this report. The underlayments have been evaluated for the following properties: PROPERTY IBC SECTION 1 IRC SECTION 1 Physical Properties 104.11, 1506 and 1507 R104.11, R904 and R905 Fire Classification 1505 R902.1 1 Referenced sections apply to 2012 and 2009 IBC and IRC 3.0 DESCRIPTION Epilay Superior, Ultra and Platinum are four-layered roofing underlayments consisting of a non-woven polypropylene scrim bonded to a woven polypropylene scrim and coated on both sides. The nominal weights of the Epilay Superior, Ultra and Platinum underlayments are 2.25, 2.90 and 3.70 lb/100 ft 2 (110, 140 and 180 g/m 2 ) respectively. Standard size rolls are 4 feet wide (1220 mm) by 250 feet long (76 m). The Epilay Superior, Ultra and Platinum underlayments have water vapor transmission of 0.154, 0.326 and 0.142 perms (outdoor to indoor) respectively when tested in accordance with ASTM E96 (Method B water method). 4.0 INSTALLATION 4.1 General: Installation of the underlayments must comply with the applicable code, this report, and the report holder s published installation instructions. The underlayments must be installed in accordance with the subsections of IBC Section 1507 and IRC Section R905 applicable to the roof covering being installed. The underlayments must be laid with the print side up, with laps as required by the applicable code, evaluation report, or manufacturer s instructions, whichever is more restrictive. The roof covering may be installed immediately following the underlayment application and the underlayment must be covered within the time designated in the report holder s published installation instructions. 4.2 Ice Barrier: The Epilay roof underlayments have not been evaluated for use as an ice barrier. In areas of the roof required by IBC Section 1507 or IRC Section R905 to have an ice barrier, a self-adhering polymer modified bitumen sheet complying with ASTM D1970, or two layers of code-complying underlayment solidly cemented together, must be used such that the ice barrier extends up the roof a minimum distance of 24 inches (610 mm) inside the interior wall line of the building. The Epilay Superior, Ultra and Platinum underlayments installed in the field of the roof must overlap the ice barrier. 4.3 Fire Classification: The Epilay Superior, Ultra and Platinum roof underlayments may be used as a component of a classified roof assembly when specifically recognized as such in a listing approved by the code official. The underlayments may also be used as an alternative to the underlayments specified in the code for roof coverings of brick, masonry, slate, clay or concrete roof tile, exposed concrete roof deck, ferrous or copper shingles or sheets, and metal sheets and shingles. 545 E. Algonquin Road, Suite F 1-888-347-5478 Arlington Heights, IL 60005 www.intertek.com Epilay Inc. 30450 Rev: Sep 30 2013 5:36PM Uncontrolled Copy Page 4 of 5

Epilay, IRR-1004 (page 2 of 2) Intertek Research Report-1004 Page 2 of 2 5.0 CONDITIONS OF USE The Epilay Superior, Ultra and Platinum roof underlayments described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with this report, the applicable code and the report holder s published installation instructions. The provisions of this report take precedence over the provisions in the report holder s installation instructions. 5.2 Installation is limited to use with approved mechanically attached roof covering systems. 5.3 Installation is limited to installations where the roof covering does not involve hot asphalt or coal-tar pitch. 6.2 Data in accordance with the ICC-ES Acceptance Criteria for Polypropylene Roof Underlayments (AC 207), dated February 2012. 6.3 Intertek Warnock Hersey Listing Report Epilay Superior, Ultra and Platinum Roofing Underlayments on https://whdirectory.intertek.com. 7.0 IDENTIFICATION The roof underlayments are marked at 24-inch (0.61 m) intervals with the product name (Superior, Ultra or Platinum). Each roll of the product is labeled with the report holder s name (Epilay Inc.), the product name, the manufacturing date code, and the Intertek Research Report number (IRR- 1004). 5.4 Installation is limited to roof slopes of 2:12 (17%) or greater. 5.5 Attic ventilation must be provided in accordance with the applicable code since there are no requirements to evaluate vapor permeability of the underlayment. 5.6 The Epilay Superior, Ultra and Platinum roof underlayments have not been evaluated for use as ice barriers. 5.7 Epilay Superior, Ultra and Platinum roof underlayments are manufactured under a quality control program with inspections by Intertek Testing Services NA Ltd. (AA-690). 5.8 The approval of building products is the responsibility of the Authority Having Jurisdiction. 5.9 Intertek Research Reports shall not be used in any manner that implies an endorsement of the product, material or system by Intertek. 5.10 The current status of any Intertek Research Report can be verified on the Intertek Directory of Certified Products (https://whdirectory.intertek.com). 6.0 SUPPORTING EVIDENCE 6.1 Reports of tests in accordance with ASTM E 108. This Intertek Research Report ( Report ) is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Page 2 of 2 Epilay Inc. 30450 Rev: Sep 30 2013 5:36PM Uncontrolled Copy Page 5 of 5