COLD GOLD TM FLIP BOOK. Roofing System COLD-APPLIED ROOFING SYSTEMS. FLASHING BOARD MEMBRANE CAP BASE COVER INSUL ATION VA PO R RETARDERS

Similar documents
Mechanical Attachment of Separation Panels Hot Asphalt Attachment of Separation Panels

B u l l e t i n MODIFIED BITUMEN MEMBRANES OVER SOPRABOARD SYSTEM (AARS) ADHESIVE APPLIED ROOFING SYSTEM

1 Exam Prep NRCA Roofing Manual: NRCA Roofing Manual: Membrane Roof Systems 2011 Tabs and Highlights

B u l l e t i n SOPRA-ISO MECHANICALLY FASTENED AND SOPRABOARD ADHERED SYSTEM (PARS) PARTIALLY ATTACHED (HYBRIDE) ROOFING SYSTEM

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

B u l l e t i n MOD-BIT COLVENT SYSTEM (AARS) ADHESIVE APPLIED ROOFING SYSTEM

C. Applicable building codes should always be checked prior to proposing the application to Mule-Hide or the building owner.

SECTION ROOF AND DECK INSULATION

B u l l e t i n SOPRABOARD MECHANICALLY FASTENED OVER POLYISOCYANURATE INSULATION BOARD (PARS) PARTIALLY ATTACHED (HYBRIDE) ROOFING SYSTEM

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

MINERAL SURFACE CAP SHEET

COMMERCIAL & INDUSTRIAL

SECTION 07530CP EPDM MEMBRANE ROOFING

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Section 7 Waterproofing Roofing Standards

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

CRCA Education Series. Self-Adhering Membrane Roofing Systems for Low Slope Roofs

Henry Self-Adhering Roofing Underlayments. self-adhering. roofing underlayments DESIGNED FOR: Shingles. Tile. Metal. Slate

Polyglass SBS Roof Membranes. Performance You Can Count On

2007 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (RAS)

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

B u l l e t i n SOPRASMART ISO HD 180 MODIFIED BITUMEN SYSTEM DUOTACK ADHERED (AARS) ADHESIVE APPLIED ROOFING SYSTEM

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

WATERPROOFING TAMKOWATERPROOFING.COM

COMMERCIAL & INDUSTRIAL. Premium Products Catalogue

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 07 THERMAL AND MOISTURE PROTECTION

Pol-E-Base Modified Bitumen Roof System

B u l l e t i n SOPRABOARD MODIFIED BITUMEN SYSTEM (PARS) PARTIALLY ATTACHED (HYBRIDE) ROOFING SYSTEM

J&L Building Materials, Inc. Commercial Roofing

Coal Tar Application and Design Considerations

Liquid-Applied Roof Solutions ACRYLIC & SILICONE COATINGS PRIMERS & ACCESSORIES

RECOMMENDED DESIGN SPECIFICATION

WATERPROOFING TAMKOWATERPROOFING.COM

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PRODUCT CONTROL SECTION

PRODUCT CONTROL SECTION

COMMERCIAL ROOFING SYSTEMS

PART 3 GENERAL REQUIREMENTS

SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS MEMBRANE ROOFING

EverGuard Plaza Deck Roofing For Above-Grade Plaza Deck Applications

SECTION ELASTOMERIC MEMBRANE ROOFING

Adhesive Pull Test Standard Testing Procedures

SECTION 1 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING

SDI-1000 Steel Deck - Insulated

G October 2018

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

Thermoplastic Single Ply & Multi-Ply Roofing Systems

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

G October 2018

National Master Specification (NMS) Section SECTION INCLUDES.1 Materials and installation for modified bituminous roofing.

ROOF REPLACEMENT AND ALTERATIONS TO WOODSTOCK Barrett Architecture, PC WASTE WATER TREATMENT FACILITY - Woodstock, VT February 28, 2019 SECTION

WATERPROOFING TAMKOWATERPROOFING.COM

"Square" means a standard roofing measurement equal to 100 sq. ft. or 10 ft.-0" x 10 ft.-0".

B.U.R., Modified & Shingle. Roofing Systems. Section 3 - Low Slope Roofing Installation Instructions

Light-Metal Roof Edge, Raised

Engineering Services Program

ALSAN RS System Selection Guidelines

PRODUCT CONTROL SECTION

POLYGLASS U.S.A., INC. CORPORATE HEADQUARTERS

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

Firestone Asphalt Roofing Systems

White Reflective Membranes and Coatings

OREGON CONVENTION CENTER CHILLER PLANT RE-DESIGN CD SET

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

J41 Reinforced bitumen membrane roof coverings

SBS Hot-Mopped & Cold Adhesive Roofing (COMGN289) Updated: 1/17

SOPRA-ISO V ALU AND SOPRA-ISO V PLUS

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

UL Evaluation Report UL ER Issued: December 19, 2014 Revised: August 14, UL Category Code: ULFB. CSI MasterFormat

INSTA STIK ROOFING STD

JOB # ISSUED: 03/29/2017

Sika-Trocal C200 Adhesive. Sika-Trocal C200 is an adhesive to bond certain insulation boards on approved substrates.

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

Student Services & Classroom Addition

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

J41 Reinforced bitumen membrane roof coverings

Roofing Insulation Products The Trusted Leader in Polyiso Roofing Insulation Solutions

SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS MEMBRANE ROOFING

TGIK.R Roofing Systems, Uplift Resistance. Roofing Systems, Uplift Resistance

Firestone Polyiso Boards

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

HYDRO-TUFF HFA. Hot Fluid Applied Rubberized Asphalt Waterproofing Membrane

POLYISO Polyisocyanurate Roofing Insulation

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION SELF-ADHERING SHEET WATERPROOFING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

A. National Roofing Contractors Association (NRCA) Roofing and Waterproofing Manual

SECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.

PRODUCT CONTROL SECTION

Design and Construction Standards SECTION MODIFIED BITUMEN ROOFING SYSTEM

MEMBRANES SELF-ADHERED. For Commercial And Residential Roofing Systems

WICOMICO COUNTY BOARD OF EDUCATION

UL Evaluation Report UL ER Issued: June 29, 2015 Revised: July 29, UL Category Code: ULFB. CSI MasterFormat

SECTION ASPHALT SHINGLE ROOFING SYSTEMS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".

Transcription:

COLD GOLD TM COLD-APPLIED ROOFING SYSTEMS CAP CAP Roofing System FLIP BOOK www.iko.com

(CHOOSE ONE) MP-180-CAP MP-HD-CAP MP-250-CAP PREVENT MP-180 PREVENT MP-250 PREVENT PREMIUM MP-250 Flashings to be a maximum width of 39.5 (width of roll), installed in the machine direction and staggered a minimum of 12 from all joints. All side laps shall be 3.5. Flashings to be embedded in a full coat of IKO Cold Gold TM Flashing Adhesive. IKO s requirements are concurrent with the recommendations of the CRCA in that 2 ply polyester reinforced flashings are desirable due to their superior elongation and tear strength as opposed to fiberglass reinforced flashings. 3.30-3.31, 4.16.1, 6.16.1 3.28-3.31, 3.29, 4.14.1, 4.16.1, 6.14.1, 6.16.1 CAP CAP 1

(CHOOSE ONE) MP-180-CAP MP-HD-CAP MP-250-CAP PREVENT MP-180 PREVENT MP-250 PREVENT PREMIUM MP-250 To adhere cap sheet, a full coat of Cold Gold TM Field Adhesive must be used. All cap sheet side laps shall be 3.5. All capsheet end laps shall be 6. The side and end laps of the cap sheet shall be staggered a minimum of 12 from all joints. 3.30-3.31, 4.16.1, 6.16.1 CAP 2

Flashings are adhered with a full coat of IKO Cold Gold TM Flashing Adhesive. IKO Cold Gold TM Flashing Adhesive is designed primarily to adhere IKO Modiflex modified bitumen membranes to steep/vertical surfaces. This solvent-free and low VOC adhesive has fast set time and an extremely strong bonding strength. Flashings to be a maximum width of 39.5 (width of roll), installed in the machine direction and staggered a minimum of 12 from all joints. All side laps shall be 3.5. IKO s requirements are concurrent with the recommendations of the CRCA in that 2 ply polyester reinforced flashings are desirable due to their superior elongation and tear strength as opposed to fibreglass reinforced flashings. 3.34, 4.17.1, 6.17.1 (Part 8) 3.28-3.31, 3.29, 4.14.1, 4.16.1, 6.14.1, 6.16.1 3

(CHOOSE ONE) MF-95-SS- MF-95-SS- is an inorganic reinforcing mat of high-strength non-woven glass fibers, impregnated and coated with SBS modified bitumen to a nominal thickness of 2.2 mm (87 mils). Both the top and bottom surfaces are covered with sand to allow application via IKO Cold Gold TM Field Adhesive. MF-180-SS- MF-180-SS- is an inorganic reinforcing mat of high-strength non-woven glass fibers, impregnated and coated with Modiflex SBS modified bitumen to a thickness of approximately 2.5 mm (98 mils). Both the top and bottom surfaces are covered with sand to allow application via IKO Cold Gold TM Field Adhesive. To adhere base sheet, a full coat of Cold Gold TM must be used. All base sheet side laps shall be 3.5. All base sheet end laps shall be 6. The side and end laps of thebase sheet shall be staggered a minimum of 12 from the cap sheet side and end laps. NOTE: Vapor Retarder, Base and Cap Membranes are adhered with IKO Cold Gold TM Field Adhesive - a solvent free, single component, moisture-cured, cold-applied interply adhesive. The substantial cure time is 48 hours. 3.28-3.29, 4.14.1, 6.14.1, 9.14.1 4

PROTECTO Protectoboard is composed of a mineral-fortified asphaltic core between two non-woven glass fiber mats. Protectoboard may be used as a cover board over IKOTherm insulation, as a re-cover board in a re-roof installation, or any other application where it is used as a new substrate for a modified bitumen or BUR roofing membrane. To adhere Protectoboard, IKO Millennium must be used. 3.25-3.27, 4.11.1, 4.12.1, 6.11.1, 6.12.1 5

IKOTHERM IKOTherm is a rigid polyisocyanurate insulation with high thermal properties. It is constructed from a closed cell polyisocyanurate foam core bonded on each side to glass fiber reinforced facers during the manufacturing process. To adhere IKOTherm, IKO Millennium should be applied in ribbons. NOTE: IKOTherm III with acrylic-coated facers and IKOTherm 25 psi are also available. Typical detail where optional 2nd layer of IKOTherm is installed with IKO Millennium. 3.25-3.27, 4.11.1, 4.12.1, 6.11.1, 6.12.1 STEEL WOOD CONCRETE 6

(CHOOSE ONE) IKO MVP IKO MVP is a self-adhering vapor retardant membrane, composed of modified rubber asphalt with a top surface film of high density cross laminated polyethylene. This product should not be applied at temperatures below -10 C. ARMOURGARD VAPOR RETARDANT Composed of two layers of kraft paper bonded together with asphalt. Strands of fibreglass reinforcement are intertwined near each edge for added strength and tear resistance. MODIFIED ROLL e.g. MF-95-SS-, MP-180-SS- (Wood & Concrete only) NOTE: ArmourGard Vapor Retardant can be adhered with ArmourGard Vapor Retardant Adhesive. Sanded-base modified rolls are adhered with IKO Cold Gold TM Field Adhesive. 3.22, 4.081, 6.08.1, 9.08.1 7

(CHOOSE ONE) STEEL Steel decks must be a minimum of 22 gauge, manufactured from milled steel and be factory primed or galvanized to resist rusting. WOOD Plank/Heavy Timber - min 1 Plywood - min 15/32 Steel - 3.11 Concrete - 3.12-3.14, 4.06.1.3 Wood - 3.15 & 3.16 Roof Decks Re-Cover - 3.20, 4.07.1, 6.07.1, 9.07.1 STEEL WOOD CONCRETE 8

Accessories, Options & Additional Considerations Drainage - 3.09 Asphalt - 3.23, 4.09.1, 6.9.1, 9.09.1 Cant Strips - 3.33, 4.13.1, 6.13.1, 9.13.1 Wood Nailers - 3.24, 4.10.1, 6.10.1, 9.10.1 Expansion Joints - 3.21 Temporary Closures - 4.19.1, 6.19.1, 9.19.1 Sheet Metal - 3.38, 4.18.1, 6.18.1, 9.18.1 Roof Walkways - 3.35, 4.21.1, 6.21.1 Cap Sheet Repair - 4.20.1, 6.20.1 NOTE: Use of the above may or may not be applicable to your specific roof. A properly designed and constructed roof deck, as well as the proper interrelationship of all building components are the responsibility of the architect, engineer and/or building owner. The density, moisture, integrity and other inherent elements of the deck must also be suitable to receive the roof. IKO is not responsible for any of the previously mentioned and IKO shall not assume responsibility for these issues under any circumstances. Note: The physical properties of the products described in this catalogue represent average typical results obtained by testing our products according to accepted industry test methods. These values are subject to normal manufacturing variations, and are supplied as a technical guideline only; they may be subject to change without notice. Current product specifications can be confirmed by contacting your local IKO technical Representative. Also, the guide specifications contained herein are offered as general information for the design and installation of IKO roof assemblies. IKO Industries Limited is a supplier of materials, and we cannot assume liability for errors in roof design, engineering, or application. The architect, contractor, and/ or building owner s representative must verify all dimensions, details and suitability of roof design. All values shown are approximate. Product and color availability subject to shipping area. The information in this document is subject to change without notice. IKO assumes no responsibility for errors that may appear in this document. Thank you for considering IKO Premium Roofing products. For additional information on IKO s full line of superior Commercial/Industrial Roofing and Waterproofing products please call: 1-855-IKO-ROOF (1-855-456-7663), or visit our web site at: www.iko.com Copyright 02/15 - MM3L176 www.iko.com