The skylight has a specific top and bottom and can not be rotated.

Similar documents
VELUX America Inc. SPECIFICATION FOR MODEL FS NO LEAK FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

VELUX America Inc. SPECIFICATION FOR MODEL VS and VSE NO LEAK VENTILATING SKYLIGHT SECTION UNIT SKYLIGHTS

VELUX America Inc. SPECIFICATION FOR MODEL VCE/VCM/VCS VENTING CURB MOUNT SKYLIGHT SECTION UNIT SKYLIGHTS

VELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

Operable / Fixed Skylight Milgard Aluminum Window

Product information Centre-pivot white-painted roof window GGL

Product information Vertical window element VFE

Product information Top-operated centre-pivot polyurethane roof window GGU

Product information Top-hung roof window GPL

Product information Roof balcony CABRIO GDL

Product information Top-hung white polyurethane roof window GPU

Product information Roof balcony CABRIO GDL

Product information Rescue opening window GTL

Product information Additional window element GIL

Product information VELUX INTEGRA flat roof window CVP with curved glass cover ISD

SECTION VINYL (PVC) WINDOWS

Product information Rod operated flat roof window CVP

Fixed Curb Mount (FCM) Unit Skylight - Guide Specification

Product information Additional window element GIU

Product information Roof terrace GEL + VEA/VEB/VEC

Product information Vertical window element VIU

Architectural Wall Products Guide Specifications

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Architectural Roof and Wall Products Guide Specifications

Product information Fixed flat roof window CFP

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

VELUX INTEGRA VCM/VCE VELUX INTEGRA Solar VCS

Product information VELUX INTEGRA centre-pivot roof window GGL

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS

Vinyl Window Designs Ltd. 550 Oakdale Road Toronto, ON M3N 1W6 SPECIFICATIONS

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

LOG COLLEGE MIDDLE SCHOOL

Columbia Skylights may qualify your project for LEED points in the following categories: Columbia Skylights - Potential Contribution to LEED projects

Georgian Window Series

New Construction Windows and Doors

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

L R ROOF WINDOWS AND SKYLIGHTS

SECTION ALL ULTREX DOUBLE HUNG WINDOW

Building Your Visions

Fixed Skylight / Fixed Multiple Skylight Milgard Aluminum Window

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

3. Roof Expansion Joints between New Building and Existing Building.

OSHA FALL PROTECTION TEST REPORT. Rendered to: VELUX America Inc. SERIES/MODEL: VCM/VCE B PRODUCT TYPE: Venting Curb Mounted Skylight

WATERGATE COMMUNITY ASSOCIATION 8 Captain Drive Emeryville, California Office: / Fax: WINDOW REPLACEMENT GUIDELINES

Architectural Roof and Wall Products Guide Specifications

Curtainwalls. Brussels Window. Objectives. Windows & Curtainwalls. Curtainwalls. 1 R2 R3. High tech? Low tech?

SECTION SPECIAL FUNCTION GLAZING

Commercial Dome Unit Skylight - Guide Specification

SIDE HINGED SECURITY ALUMINUM WINDOWS

Architectural Roof and Wall Products Guide Specifications

SILVER LINE BUILDING PRODUCTS. Series 1700 Heavy Commercial Aluminum Double Hung. HC65 48 x84 / HC50 60 x96 Replacement Window

m a j e s t y Wood Windows and Patio Doors

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SKYLIGHTS ROOFLIGHTS FLAT ROOF WINDOWS. let the sunlight come in

SECTION SERIES 200 DOUBLE-HUNG VINYL WINDOWS

Guide Specifications- Section

SECTION ALUMINUM WINDOWS

CHAPTER 4 INTEGRITY WOOD ULTREX GLIDER

SECTION K. Section Millwork: Wood trim other than furnished by door and frame manufacturer

CS-100 Guide Specifications

SECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes)

The S.15 ALL WOOD WITH ALUMINUM CORE LIFT & SLIDE DOOR SYSTEM. Expanding spaces to the extraordinary

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

OSHA Title 8 General Industry Safety Orders Floor Openings, Floor Holes, Skylights and Roofs

CENTRA WINDOWS. Manufacturer for Centra Construction Group of Companies

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

SILVER LINE BUILDING PRODUCTS

08620 UNIT SKYLIGHTS Tufflite double polycarbonate glazed Frb

Series 4900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

SECTION ALUMINUM GLASS FLOOR SKYLIGHT SYSTEMS

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

Architectural Roof Products Guide Specifications

Heavy Commercial / Architectural Projected Windows Series L900T AW150

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Guide Specifications- Section

Product information Flat roof smoke ventilation window CSP

ENERLOGIC SERIES GUIDE SPECIFICATIONS

SECTION / METAL FRAMED SKYLIGHTS

Originally Issued: 10/08/2010 Revised: 11/02/2018 Valid Through: 09/30/2019

PRODUCT SPECIFICATION SERIES 5000T PUNCHED WINDOW THERMALLY BROKEN ALUMINUM CASEMENT/AWNING/ FIXED WINDOW

SECTION ** NOTE TO SPECIFIER ** Overhead Door Corp.; Residential Sectional Overhead Door products.

Series - 1

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System

Series - 1

3 Season Porch Windows

Product information Flat roof exit window CXP

STEALTH ROOFLIGHTS. Product. Scope. Appraisal No. 987 [2018] Appraisal No. 987 (2018) BRANZ Appraisals

Architectural Roof Products Guide Specifications

Guide Specification for Pre-Engineered Skylight System. A. Engineering, design and drafting of the entire skylight system.

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

Bioclimatic Pergola with ajustable blades

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

WESTECK WINDOWS and DOORS

Transcription:

Date: 03/24/2017 Created by: Sky-GPM / WQ VSS Starting Production Code: BC 01A VS / VSE / VSS Product Data Sheet VS / VSE Starting Production Code: AX 08A The VS / VSE / VSS deck mount, top hinged, venting, "No Leak" skylights: Consisting of the following integrated components: an interior condensation drainage gasket, pre-painted white wooden frame and sash, a VS manual, VSE electric, or VSS solar operator, exterior maintenance-free aluminum cladding and counter flashing, corner keys, and an insulating thermal pane glass unit with two seals, warm edge spacer system, and three coats of LowE3 silver to increase visible light transmittance while reducing solar heat gain. The skylights are mounted to the roof deck by fastening the continuous deck seal mounting system with durable foam seal directly to the roof deck. Description General NOTE: The VSE & VSS skylights are operated and controlled by a 2.4 GHz radio frequency remote control and the VS is operated with a ZCT 300 manual control rod or a ZMT 300 battery operated control rod. VSS skylight is charged (from the factory) and ready for use when the unit is removed from the carton and ready for installation. The battery should have enough power to operate the VSS unit at least a minimum 3 or more times during the installation process before recharging is required. For the battery to reach its fully charged capacity the solar panel must receive an average of 24 hours of direct sunlight. This recharging time is subject to variation due to time of year due to sun angle, shading of the PV panel. VSS units placed in shaded areas of the roof or in northern latitudes such as Canada or Seattle in the US, may only receive enough sunlight to recharge the battery enough to operate the skylights 2-3 times daily all year. As with any type rechargeable battery, the number of operations from a fully charged battery will reduce with age. The remote control will display "limited by power supply" if the battery does not have enough power to open the skylight. If skylight is open, the operator will automatically close when battery reaches low voltage and if the operator is stopped during this operation, it will resume closing after 2 minutes. After closing the operator will not open again until the battery voltage has been charged to a level to support operation Instructions Orientation Roof Pitch Instructions included in every box, and are also available at VELUX country-specific websites, or through VELUX country-specific sales companies. The skylight has a specific top and bottom and can not be rotated. 0-10 - Install with site-built curb to elevate the pitch of the glass to 14 degrees. Then install a VELUX ECB counter flashing kit to create a water tight joint between the skylight and the site-built curb. Drawings and instructions are available on the VELUX country-specific web site. 14-85 - Mount the skylight directly to the roof deck by aligning and securing the continuous deck sealing mounting system directly to the roof deck. Under 20 - Condensation drips from the interior pane can be expected.

Flashings EDL - Single installation with thin roofing material. EDW - Single installation with high profile roofing material. NOT available with VSS EDM - Single installation with metal roofing panels. ECB - Site-built curb counter flashing for low sloped applications. EKL/EKX - Side by side and/or over and under combinations with thin roofing material. NOTE: VSS units in combi application must be placed as lower units only. VSS units can not be placed above other skylight units in combi applications. Compatibility EKW/EKX - Side by side and/or over and under combinations with high profile roofing material. NOTE: VSS units in combi application must be placed as lower units only. VSS units can not be placed above other skylight units in combi applications. Materials Interior Accessories Exterior Accessories Products Wood Cladding FSCH Solar room darkening double pleated for VS/ VSS/ VSE FSLH Solar light filtering pleated blind for VS/ VSS/ VSE PAH manually operated venetian blind for VS None available ZOZ 216 - Adhesive skylight underlayment. VSS is provided with four filler pieces, pre-cut to proper length. Ponderosa pine frame and sash, finished white in the factory; or, as a special order, natural wood with a short term colorless wood preservative (base treatment). For select markets, wood is finished with a clear coat in the factory Lacquered aluminum, neutral gray color with a Kynar 500 top finish to prevent fading. 0.65mm thick. Copper - VS / VSE available with copper - call for lead time. NOTE: VSS not available in copper.

VS/ VSE/VSS Product Data Sheet Page 2 NOTE: Verify model-specific glazing availability with local VELUX sales companies. Type 05 - LoE3 tempered over tempered - Double-pane sealed insulating glass units with warm edge stainless steel spacer, filled with 95% Argon gas and coated with three layers of spectrally selective microscopic silver particles. Overall pane thickness is 17.2mm. (NOT available with VSE or VSS) Materials, Cont'd. Glazings Type 04 - LoE3 tempered over laminated with NEAT coated exterior - All the benefits of Type 05 but with a laminated interior heat-strengthened glass lite for safety and better protection from both heat gain and fading. Overall pane thickness is 17.6mm. Type 06 - "Impact" - Laminated heat strengthened with tempered LoE3 with NEAT coated exterior. Overall pane thickness is 18.2mm. Type 08 - White laminated - Laminated heat strengthened with tempered LoE3. Same as 04 but a white inner layer. Over all pane thickness is 17.6mm. Gaskets Deck Sealing Mounting Bracket Type 10 - "Snow load" - Tempered over laminated tempered LoE3 with Neat coated exterior. Overall pane thickness is 18.2mm. Patented, engineered rubber gaskets to prevent air infiltration and water penetration. Pre-engineered Deck Seal mounting system with a corrosion-resistant coating. The Deck Seal mounting system is pre-attached all the way around the perimeter of the skylight and has a durable closed cell foam that seals the skylight to the roof deck. Deck seal size: 1 1/4" up the frame and 1 1/4" away from the skylight frame. Operator Cover White PVC VSE is pre-wired for electric sunscreen accessories and the Pick&Click sunscreen mounting brackets are preinstalled. Sash In case of power failure the VSE sash operator chain can be disconnected from the sash by removing the plug and turning the provided Allen wrench counter clockwise. VSE electrical operator is available in one variant and is used with all skylight markets. Power requirements: 100-240v, 50-60 Hz, 18w. A 2.4 GHz remote control is a standard component with each VSE and VSS. Operators VSS solar charged battery operator is available in one variant. Battery pack is a 9 cell Panasonic NiMH 10.8V, 2100 mah. Battery is charged by a 14-cell PV panel. VS manual operator by Truth is comprised of a gear driven system that is controlled by a closed loop or an in reach crank handle. Operation A robust chain with one point of contact is used to open and close the sash a full 11 inches. One chain size for all venting skylights. Rain Sensor VSE Electric VS Manual Electric operators are equipped with an integral rain sensor that automatically closes the skylight, provided the rain sensor gets wet, when there is power to the skylight. KLB 100 - Battery backup KLI 110 - Wall mounted keypad KLR 200 - Radio frequency remote KLF 100 - Home automation integration kit and signal repeater ZCT 100-3' Extension to ZCT 300 and ZMT 300 ZCT 300 - Manual telescopic rod ZZZ 201 - Manual crank handle ZZZ 202 - Replacement hook ZZZ 203 - Angle adaptor for chain operator

VS / VSE / VSS Product Data Sheet Page 3 Products Sizes Product Data Certification Warranty Changes from Earlier Versions Miscellaneous Standard Sizes Rough Opening Dimensions Ventilation Area and Daylight Area General Air, Water, Structural Thermal Frame Glass Manual, Solar and Electric Exterior Interior Operator ZOZ 216 - Adhesive skylight underlayment VSS skylight is provided with four filler pieces pre-cut to proper length, that allow the drywall groove to be filled for use in retrofit installations C01, C04, C06, C08, M02¹, M04, M06, M08, M25², S01, S06 ¹VS / VSS Only; ²Not available for US market. Size Width Size Height C01, C04, C06, C08 21" M25 21 9/16" M02, M04, M06, M08, M25 30 1/16" C01, S01 26 7/8" S01, S06 44 1/4" M02 C04, M04 30" 37 7/8" C06, M06, S06 45 3/4" C08, M08 54 7/16" Size Ventilation Area Size Daylight Area C01 2.60 sq. ft. C01 2.27 sq. ft. C04 3.56 sq. ft. C04 3.50 sq. ft. C06 4.14 sq. ft. C06 4.38 sq. ft. C08 4.71 sq. ft. C08 5.34 sq. ft. M25 2.81 sq. ft. M25 2.55 sq. ft. M02 2.80 sq. ft. M02 4.11 sq. ft. M04 4.17 sq. ft. M04 5.48 sq. ft. M06 4.75 sq. ft. M06 6.86 sq. ft. M08 5.32 sq. ft. M08 8.36 sq. ft. S01 4.31 sq. ft. S01 5.57 sq. ft. S06 5.84 sq. ft. S06 10.73 sq. ft. For U.S. market, exceeds International Building Code (IBC), International Residential Code (IRC), and International Energy Conservation Code (IECC). Certification information for specific markets is available from the market-specific sales companies. Electric is UL Listed. UL File E82681 For U.S. market, certified to WDMA/Hallmark standards. Certification information for specific markets is available from the market-specific sales companies. For U. S. market, NFRC certified and labeled to exceed Energy Star U-value and Solar Heat Gain (SHGC) requirements for all climate zones. For 10-years from the date of purchase, VELUX warrants that the skylight will be free from defects in material and workmanship. For 20-years from the date of purchase, VELUX warrants that the insulated glass pane will not develop a material obstruction of vision due to a failure of the glass seal. For 10-years from the date of installation, provided the skylight is installed with the three layers of protection, per the manufacturer's instructions. For 5-years from the date of purchase, VELUX warrants manual, solar and electric controls will be free from defects in material and workmanship. New product design to match the skylight product family. New neutral gray color, lower profile and smoother look from the exterior. Factory finished white with a 10 year maintenance free frame and sash. Smaller operator and operator cover. The PVC white plastic operator cover now snaps into without the need for screws. New and improved solid state operator with integral rain sensor. Very quiet.

VS / VSE / VSS Product Data Sheet Page 4 Changes from Earlier Versions, Cont'd. Type Sign Rain Sensor Example Location VSS - Piezo electric sensor that is sensitive to the mechanical impact (vibration) of raindrops. Sensitivity depends heavily on size and speed of the raindrops, as well as angle of impact. VSE - Rain sensor is located at corner of side frame and bottom frame, between sash and frame. VSE C04 2004 AX 08A On the top left corner of the wooden frame if viewing from the inside.